BENCHMARK WIRELINE PRODUCTS AMS Monitor



Similar documents
SCHEDULING SOFTWARE. This P.C. program must be running at all times, or PIN number verification will not be allowed.

SA-9600 Surface Area Software Manual

User Manual. Thermo Scientific Orion

Lab: Data Backup and Recovery in Windows XP

You can search the event by POS and you can also add the Time Search condition to narrow the search range. By

Guide to Installing BBL Crystal MIND on Windows 7

Lab - Data Backup and Recovery in Windows XP

Cyberex BCM-SFCM Configurator/Monitor User's Manual

UPS Monitoring and Management Software

64-Bit Compatibility with Micromeritics Applications

Rev. 06 JAN Document Control User Guide: Using Outlook within Skandocs

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

AUDITVIEW USER INSTRUCTIONS

MCAPS 3000 DISASTER RECOVERY GUIDE

BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL

USB PC Adapter V4 Configuration

User's Guide DylosLogger Software Version 1.6

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

Installing Remote Desktop Connection

Using Remote Web Workplace Version 1.01

Config software for D2 systems USER S MANUAL

MTA Course: Windows Operating System Fundamentals Topic: Understand backup and recovery methods File name: 10753_WindowsOS_SA_6.

User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

Moxa Device Manager 2.0 User s Guide

5.6.2 Optional Lab: Restore Points in Windows Vista

Model 288B Charge Plate Graphing Software Operators Guide

PrivateWire Gateway Load Balancing and High Availability using Microsoft SQL Server Replication

RACEAIR REMOTE PAGER SYSTEM

Coyote SP - Installation Notes

AUDITVIEW USER INSTRUCTIONS

Welch Allyn Vital Signs Monitor 300 Series

A. I do not have my own personal certificate I am a new client or want to download a new certificate

Important Notes for WinConnect Server VS Software Installation:

SAPIP GUI INSTALLATION. Table of Contents

Converting InfoPlus.21 Data to a Microsoft SQL Server 2000 Database

Short Manual Intellect v SP2 module Unipos Contents:

Application Note CTAN #374

Technical Data Sheet

Maintaining the Content Server

SonicWALL CDP 5.0 Microsoft Exchange InfoStore Backup and Restore

Galileo Print Manager

Nursery Inventory Software (EPLPPS) Frequently Asked Questions

High Impact & Alpha Five: A Mail Merge Guide.

hp digital home networking wireless USB network adapter hn210w quick start guide

Basic Operation and Function of the MSD Pro Data Plus. Best viewed in printed form. Click on File>Print.

Entire Connection Version 4.2.1

Using Microsoft Access Databases

Running the R4 Software on a USB Port

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

Create Signature for the Scott County Family Y

SMS Database System Quick Start. [Version 1.0.3]

ATVS. Amano Time Validation System. Installation and Operation Guide. Enterprise Edition Version 4.2

Important Notes for WinConnect Server ES Software Installation:

Connecting a Leica TPS1200 Robotic Total Station to EvidenceRecorder

Legal Notes. Regarding Trademarks KYOCERA Document Solutions Inc.

Webmail Access. Contents

How To: Upload a Custom Tune to Your Predator or Trinity PREP:

BlackBerry Enterprise Server

Using AppMetrics to Handle Hung Components and Applications

Online Backup and Recovery Manager Setup for Microsoft Windows.

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

TR-3 Channel Editor. Software Manual

Install MS SQL Server 2012 Express Edition

Tools Editor. FIG: 14.1 Select edit logging Tool Details

To successfully initialize Microsoft Outlook (Outlook) the first time, settings need to be verified.

PP8X Printer Driver Installation Instruction


Table of Contents ShareCenter Sync Overview...3

Format the USB Thumb Drive for Ghost

File Management Utility. T u t o r i a l

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

TECHNICAL SUPPORT PRODUCT WORKFLOW

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

BUSINESS SOFTWARE SOLUTIONS. Business Software Solutions Error Troubleshooting

Allen Bradley PLC connection procedure (RSLogix 500 Version 3.1.9, RSLinx Version 2.1)

Configuration Guide. Remote Backups How-To Guide. Overview

BMV-602 Data Link Manual

Elo 1725L 17 Touch Screen Monitor Installation Guide. Product Name: Elo 1725L 17- inch Monitor

How To Set Up Your

All existing accounts will be listed. 2. Click Add and select Mail to add a new account (see Figure 2). Figure 1. Figure 2

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

Copyright 1999 by EPSON America, Inc. 3/99 Torrance, California, USA

Moving the Web Security Log Database

HOSTED DESKTOP MANUAL

5.6.3 Lab: Registry Backup and Recovery in Windows XP

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

KIP Certified AutoCAD Driver KIP TRACK ACCOUNTING SYSTEM

DriveRight. Fleet Management Software. Getting Started Guide. CarChip. DriveRight. Drivers. Vehicles. Product #8186

Connecting a Metrologic MS9535 to a USB BT Adapter (Client Mode)

Departmental (Service) Account Set Up

1 of 10 1/31/2014 4:08 PM

Virtual Office Remote Installation Guide

Remote Management System

VRC 7900/8900 Avalanche Enabler User s Manual

Iridium Satellite Phonebook Tool Version H2PT0901 User Guide v3.2

Transcription:

BENCHMARK WIRELINE PRODUCTS AMS Monitor AM3KA524 USER MANUAL Rev A JUL 2008 Page 1 of 9

Introduction. The AMS monitor program is used to acquire real time data from BenchMark Wireline Products panels. It records depth, tension and speed with actual time not elapsed logging time. This program can be used to acquire this data especially during perforating/explosive services when policy requires power to be shut down. Communicating through COM1 port to the RS232 port data cab be recorded in a text file format. After some conversion the txt file data can read in WARRIOR logging software. Software. There is no big file for installation. Only one.exe file and it will open for you KERR AMS Monitor. Connecting all correct cables you can see DTS. ( Fig 1.1) Fig. 1.1 To start recording go to file and start recording You can select sampling rate 1 sample per foot or 10 samples per foot. ( Fig1.2) Fig 1.2 You need give a direction to file save. It will be a text file you can save this file where ever you want there is no specified folder for this software. ( Fig 1.3). Fig 1.3 AM3KA524 USER MANUAL Rev A JUL 2008 Page 2 of 9

On you AMS monitor screen *Recording* will show up in red color same like when you are recording with you handy cam. (Fig 1.4) Fig 1.4 To stop recording, use same file drop down menu. ( Fig 1.5) Fig 1.5. Software will confirm from you again. ( Fig 1.6) Fig 1.6 Software Options. Full Screen : AMS Monitor window will cover your whole screen. Tension Meter Mode: It will change tension meter to Incremental or Differential. AM3KA524 USER MANUAL Rev A JUL 2008 Page 3 of 9

Can change back ground color of display digits. Can change color of display digits. This option will allow you to set increment from 50 to 2000 Lbs. AM3KA524 USER MANUAL Rev A JUL 2008 Page 4 of 9

To verify all settings in KERR panel. Data recording port or data in port. Mostly now we have only one COM1. If your computer is using more than one COM port that you can direct the out of data to other source also i.e. some external hard disk or back up disk. ( No need to Adjust this setting, do not check on Activate Data Out put.) AM3KA524 USER MANUAL Rev A JUL 2008 Page 5 of 9

When you will start software first time and you will close than will generate one.ini file. Do not try to change any thing in this file. it Reading a text file You can read file in notepad but you can not plot directly from notepad. To read a file in MS Excel. Start ( pull up menu) > Programs > Microsoft office > Microsoft Office Excell. Open menu & open file ( use only above method, do not right click and use option Open With ). Select your file ( txt ) file that you recorded. Select fix width and go for next. AM3KA524 USER MANUAL Rev A JUL 2008 Page 6 of 9

By clicking on arrow or at any pint between the data you can enter a full column. You can move your arrows but actually you are moving the break lines in excel. (excel column lines). Keep open general for all Click on finish Now you have all of your data in each different column but if you right click on txt file and you open directly it will open all txt file columns merged in one excel column. So again, this is not recommended. AM3KA524 USER MANUAL Rev A JUL 2008 Page 7 of 9

It is not easy to delete a column from txt file but when you open txt file in excel than you can delete any complete column. 28/03/2008 6:15:45 PM E U + 2847.5 23.4-24 28/03/2008 6:15:46 PM E U + 2847.1 23.6-24 28/03/2008 6:15:47 PM E U + 2846.6 23.4-24 28/03/2008 6:15:49 PM E U + 2846.3 23.4-24 28/03/2008 6:15:50 PM E U + 2845.8 23.4-24 28/03/2008 6:16:09 PM E U + 2838.1 23.4-24 28/03/2008 6:16:11 PM E U + 2837.7 23.4-24 28/03/2008 6:16:12 PM E U + 2837.3 23.4-24 28/03/2008 6:16:13 PM E U + 2836.9 23.6-24 28/03/2008 6:16:14 PM E U + 2836.4 23.4-24 28/03/2008 6:16:15 PM E U + 2836.1 23.4-24 28/03/2008 6:16:16 PM E U + 2835.6 23.4-24 28/03/2008 6:16:17 PM E U + 2835.2 23.4-24 Above is the file opened by excel from txt file at 1 sample per second. From left to right you have, Date Time PM/AM Units English / Metric Direction up or down Up+ down Depth Speed Tension Let s say to read depth tension and speed, you delete all other columns 2847.5 23.4-24 2847.1 23.6-24 2846.6 23.4-24 2846.3 23.4-24 2845.8 23.4-24 2838.1 23.4-24 2837.7 23.4-24 2837.3 23.4-24 2836.9 23.6-24 2836.4 23.4-24 When you will try to save in this format a message will pop up AM3KA524 USER MANUAL Rev A JUL 2008 Page 8 of 9

Say yes and save, Open your txt file and you have data in the following format Communication Cable: You have to connect COM serial cable with following configuration DB9 PIN OUT: 2 = TRANSMIT, 3 = RECEIVE, 5 = GROUND One side is behind the KERR panel on RS232 serial port and other end to computer. You have to connect only with COM port, you can not use any other link. Other options. When reading your data in excel you can also plot a X-Y plot. AM3KA524 USER MANUAL Rev A JUL 2008 Page 9 of 9