R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements



Similar documents
R&S SMZ Frequency Multiplier Specifications

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

R&S ZCxxx Millimeter-Wave Converters Specifications

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications

R&S Analysis Center Automatic radio network detection and situation picture visualization

R&S ZVA Vector Network Analyzer Specifications

R&S MKS9680 Modular Encryption Device Secure voice, fax and data transmission

Coupling/Decoupling Networks (CDN)

Realtime FFT processing in Rohde & Schwarz receivers

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization

ELCRODAT 5-4 Highly secure voice and data communications in digital and analog networks

R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

Rohde & Schwarz Service that adds value

R&S SITGate Next-Generation Firewall Secure access to Internet and cloud services

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

R&S AVG050 DVB Satellite Receiver Compact DVB-S and DVB-S2 satellite demodulator

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards

R&S IP-GATE IP gateway for R&S MKS9680 encryption devices

R&S IP-GATE IP gateway for ISDN encryption devices

R&S BC NETSTATE Open network management software for broadcast applications

AM/FM/ϕM Measurement Demodulator FS-K7

R&S SMZ Frequency Multiplier Precise output levels from 50 GHz to 170 GHz

Production testing of radar sensors for automotive applications

R&S ZVL Vector Network Analyzer Specifications

R&S ESL EMI Test Receiver Compact, cost-effective measuring receiver

R&S FS-K130PC Distortion Analysis Software Specifications

R&S RTO Digital Oscilloscope Resolving Security Issues When Working in Secure Areas

R&S RCMS II Remote Control & Monitoring System For ATC and air defense applications

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

Using R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products:

R&S UMS170 Compact Radiomonitoring System High performance for outdoor deployment

Test Equipment Solutions Datasheet

R&S ZNC Vector Network Analyzer Solid performance on a future-oriented platform

Apple ipad Remote Control for Broadcasting T&M Instruments Application Note

R&S RNMS3000 Radio Network Management System Utilization planning, radio network configuration and data distribution

Cond-IS RF Conducted Immunity System

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note

R&S TS-EMF EMF Measurement System Easy, frequency- selective measurement of EMF emissions

Spectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note

R&S CMWrun Sequencer Software Tool Applications

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Data Communications Competence Center

Rack mounted telephone- and leased line modem for industrial applications

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

R&S ZVB Vector Network Analyzer High measurement speed up to 20 GHz with two or four test ports

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

R&S VSE-K10x R&S FSx-K10x R&S FS-K10xPC EUTRA/LTE Measurement Software Specifications

RX-AM4SF Receiver. Pin-out. Connections

OTA performance measurements of MIMO-enabled devices

Lip-Sync Measurement (AV Delay) for TV Displays Application Note

Telephone- and leased line modem for industrial applications TD-36

Impedance 50 (75 connectors via adapters)

spinner Measurement & Calibration equipment for network analyzers

AMP CO Plus Insert for Cat. 6 A Applications

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Broadcast Drive Test Software

R&S RA CHM System Status Monitoring For maximum system availability

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

R&S VISA Release Notes Software Version 5.5.4

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

I STAR COMPUTER CO., LTD

Remote Control of ROMES on Windows 7. Application Note

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Application Note. Products: R&S VTC R&S VTS R&S VTE

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Using the Equalizer Filter in the VSA Application Firmware for R&S Signal and Spectrum Analyzer Application Note

Pluggable interface relays CR-P Pcb relays

Operating Manual UWAPS-TINY Series

Waveguide Access Point WGA631. Product Guide

Measurement setup for differential-mode and common-mode channels

NEWS. Offprint from News 201. Europe s air traffic control on the way to voice over IP

Waveform Monitor Audio & Loudness Logging

SFP Copper Transceiver 10/100/1000Base-T

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

EMC Test for Compliance with EU EMC Directive 2004/108/EU

IFS SP-PoE Splitter User Manual

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

DRM compatible RF Tuner Unit DRT1

Crosstalk effects of shielded twisted pairs

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

VoIP Measurements for WiMAX Application Note

DeltaV SISnet Repeater

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

LynX TM Silicon Photomultiplier Module - LynX-A T1-A User Guide Understanding Silicon Photomultiplier Module for improving system performance

DS 600. A contact free flux gate based current measurement sensor 600A rms

R&S RA-CM Continuous Monitoring Software Status monitoring of complex COMINT systems

Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note

Transcription:

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00

R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6 coupling network is used for performing radio disturbance and immunity measurements on unshielded symmetrical telecommunications ports for cable category CAT 6. The R&S ENY81-CA6 coupling network is used for measuring asymmetrical (common-mode) disturbance voltage on unshielded, symmetrical telecommunications ports of equipment under test (EUT). The coupling network contains two RJ-45 ports for connecting the EUT and the associated equipment (AE). On the EUT side, a longitudinal conversion loss (LCL) of 75 db is implemented to simulate operation with a category CAT 6 cable. Measurements can be performed in the frequency range from 150 khz to 30 MHz and conform to the CISPR 22:2005 and EN 55022: 2006 product standards. The R&S ENY81-CA6 can also be used for immunity measurements. These measurements are performed in line with CISPR 24 and EN 55024 as well as IEC 61000 4 6 in the frequency range from 150 khz to 80 MHz. The R&S ENY81-CA6 is tested and calibrated in accordance with CISPR 16-1-2. The calibration data supplied with the unit is valid for a symmetrical impedance of 100 Ω. Key facts JJ Eight-wire network JJ Radio disturbance measurements in line with CISPR 22: 2005 and EN 55022: 2006 (150 khz to 30 MHz) JJ Immunity measurements in line with CISPR 24 and EN 55024 (150 khz to 80 MHz) JJ CISPR 16-1-2 complied with JJ 75 db longitudinal conversion loss (LCL) JJ High transmission bandwidth for wanted signal (250 MHz) Nomenclature In the CISPR 22: 2005 and EN 55022: 2006 product standards, this type of coupling network is referred to as an impedance stabilization network (ISN). In basic standards, it is called asymmetrical artificial network (AAN), Y-network (CISPR 16) or coupling/decoupling network (CDN; IEC 61000 4 6). 2

R&S ENY81-CA6 Coupling Network Benefits and key features Functional description The R&S ENY81-CA6 terminates the EUT interface with 150 Ω (asymmetrical or common-mode impedance) and couples the EUT's asymmetrical voltage to the test receiver with a voltage division factor of typ. 9.5 db. The wanted symmetrical (differential-mode) signal passes through the coupling network almost without attenuation up to a bandwidth of 250 MHz (valid for a symmetrical impedance of 100 Ω). At the same time, the coupling network decouples the test circuit from disturbance effects (disturbance voltage, impedance) at the AE port. The R&S ENY81-CA6 coupling network features bare threaded sockets for connecting it to a reference ground plane that is arranged either horizontally or vertically. Radio disturbance measurements In line with CISPR 22: 2005 and EN 55022: 2006, disturbance voltage measurements on one unshielded symmetrical wire pair require the use of a two-wire ISN (R&S ENY21). In the case of two unshielded symmetrical wire pairs, it is necessary to use a four-wire ISN (R&S ENY41), and with four unshielded symmetrical wire pairs an eight-wire ISN (R&S ENY81 or R&S ENY81-CA6) is needed. CISPR 22: 2005 and EN 55022: 2006 specify the following conformance test method: The EUT is to be measured with a suppression of the wanted symmetrical signal corresponding to the category of the connected cable ( requirements for cable categories CAT 3, CAT 5 and CAT 6 are defined in the standard). In order to implement these test methods, the R&S ENY81-CA6 consists of a high-symmetry basic network with a longitudinal conversion loss of 75 db for cable category CAT 6. The LCL is internally implemented on the EUT side. For cable categories CAT 3 and CAT 5, the R&S ENY81 eight-wire coupling network is to be used. Immunity measurements For immunity measurements, a 150 Ω to 50 Ω adapter (100 Ω series resistor in line with IEC 61000-4-6) is required in order to calibrate the test system. This series or terminating resistor as well as various adapters for connecting the ISN are included in the R&S ENY-ITS immunity test set, which is available as an option. Functional testing A functional test of the ISN can be performed by means of the R&S ENY-FTS option and a network analyzer. The functional test includes verification of the asymmetrical impedance and phase, the voltage division factor, the longitudinal conversion loss and the decoupling attenuation. Compact, cost-effective test set consisting of the R&S ESCI EMI test receiver and the R&S ENY81-CA6 coupling network for the semiautomatic measurement of the asymmetrical disturbance voltage. 3

Ordering information Designation Type Order No. Base unit Eight-Wire ISN in line with CISPR 22: 2005 for CAT 6 R&S ENY81-CA6 1309.8526.03 Options Functional Test Set, including adapters for the R&S ENY81-CA6 R&S ENY-FTS 1309.8703.13 Immunity Test Set, including adapters for the R&S ENY81-CA6 R&S ENY-ITS 1309.8955.13 Accessories supplied Plastic carrying case lined with foam material; calibration data 1) 1) The calibration data includes asymmetrical impedance and phase, voltage division factor, decoupling attenuation, longitudinal conversion loss (LCL), transmission bandwidth and crosstalk. R&S ENY81-CA6 base unit in carrying case. Rohde & Schwarz R&S ENY81-CA6 Coupling Network 4

Specifications Specifications Frequency range Radio disturbance measurements 150 khz to 30 MHz Immunity measurements 150 khz to 80 MHz Asymmetrical impedance Impedance 0.15 MHz to 30 MHz 150 Ω ± 20 Ω >30 MHz to 80 MHz 150 Ω ± 40 Ω Phase angle 0.15 MHz to 30 MHz 0 ± 20 Voltage division factor in asymmetrical circuit 150 khz to 30 MHz calibration data supplied 1) typ. 9.5 db ± 1 db >30 MHz to 80 MHz typ. 9.5 db ± 2 db Transmission bandwidth (3 db) typ. for 100 Ω source and load impedance >250 MHz Longitudinal conversion loss (LCL) LCL (db) 75 10 log (1+(f/5) 2 ) db Tolerance for f < 2 MHz ±3 db for 2 MHz f 30 MHz 3 db/+6 db Decoupling attenuation 150 khz to 1.5 MHz linear increase with logarithmic frequency >35 db to 55 db 1.5 MHz to 30 MHz >55 db Crosstalk (PSELFEXT, EUT/AE) 1 MHz to 250 MHz linear decrease with logarithmic frequency 61 db to 15 db Power-handling capacity Max. permissible RF input voltage 15 V Max. permissible DC voltage between line and 100 V ground Max. permissible AC voltage between line and 63 V ground Max. permissible DC current forward and reverse current on one wire pair or 400 ma multiple wire pairs Connectors Output to test receiver/input from signal generator BNC female Connectors for EUT and AE RJ-45 female General data Operating temperature range +5 C to +40 C Storage temperature range 20 C to +70 C Dimensions, base unit W H D 105 mm 65 mm 110 mm (4.13 in 2.26 in 4.33 in) Weight Base unit 500 g (1.1 lb) Carrying case with base unit 1900 g (4.2 lb) 1) The calibration data includes asymmetrical impedance and phase, voltage division factor, decoupling attenuation, longitudinal conversion loss (LCL), transmission bandwidth and crosstalk. Pin assignment for the R&S ENY81-CA6 eight-wire ISN Type Application Pin assignment in line with EIA/TIA T568B Connector Pair 1/pins 4, 5 Pair 2/pins 1, 2 Pair 3/pins 3, 6 Pair 4/pins 7, 8 R&S ENY81-CA6 base unit Gigabit Ethernet (1000BaseT) RJ-45 Rohde & Schwarz R&S ENY81-CA6 Coupling Network 5

Service you can rely on J Worldwide J Local and personalized J Customized and flexible J Uncompromising quality J Long-term dependability About Rohde & Schwarz Rohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquarters are in Munich, Germany. Regional contact Europe, Africa, Middle East +49 1805 12 42 42* or +49 89 4129 137 74 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia/Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com Certified Quality System ISO 9001 DQS REG. NO 1954 QM Certified Environmental System ISO 14001 DQS REG. NO 1954 UM Rohde & Schwarz GmbH & Co. KG Mühldorfstraße 15 81671 München Phone +49 89 41 290 Fax +49 89 41 29 121 64 www.rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners Printed in Germany (ch) PD 5214.1772.32 Version 01.00 March 2009 R&S ENY81-CA6 Data without tolerance limits is not binding Subject to change *0.14 /min within German wireline network; rates may vary in other networks (wireline and mobile) and countries.