SIM_ZONAL: SOFTWARE EVALUATING INDOOR TEMPERATURE DISTRIBUTIONS AND AIR MOVEMENTS FOR RAPID APPRAISALS - FIRST APPLICATION TO AN CELL.



Similar documents
Controller design for climate control in buildings using CLIM 2000

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

ME6130 An introduction to CFD 1-1

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

New Thermal Architecture For Future Green Data Centres

The Influence of Insulation Styles on the Air Conditioning Load of Japanese Multi- Family Residences

CFD ANALYSIS CHALLENGES IN BUILDING SIMULATION FOR SIMBUILD2004 CONFERENCE. Ferdinand Schmid and Galen Burrell Architectural Energy Corporation

Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Comparison of two calculation methods used to estimate cooling energy demand and indoor summer temperatures

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

TTLL301 - Heat transfer in a bar with imposed temperature (sinusoid)

SYMP TOWARDS EXTERNAL COUPLING OF BUILDING ENERGY AND AIR FLOW MODELING PROGRAMS

CFD Application on Food Industry; Energy Saving on the Bread Oven

Integration of a fin experiment into the undergraduate heat transfer laboratory

Coupling Forced Convection in Air Gaps with Heat and Moisture Transfer inside Constructions

Ravi Kumar Singh*, K. B. Sahu**, Thakur Debasis Mishra***

A NODAL MODEL FOR DISPLACEMENT VENTILATION AND CHILLED CEILING SYSTEMS IN OFFICE SPACES

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

Supply Air Window PAZIAUD : Comparison of Two Numerical Models for Integration in Thermal Building Simulation

MODELLING COUPLED HEAT AND AIR FLOW: PING-PONG VS ONIONS

CFD Based Air Flow and Contamination Modeling of Subway Stations

EXPERIMENTAL STUDY OF A DOMESTIC HOT WATER STORAGE TANK THERMAL BEHAVIOUR

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

Heat and cold storage with PCM

Impact of Infiltration on Heating and Cooling Loads in U.S. Office Buildings

Software Development for Cooling Load Estimation by CLTD Method

TEXTILE FABRICS AS THERMAL INSULATORS

Customer Training Material. Lecture 2. Introduction to. Methodology ANSYS FLUENT. ANSYS, Inc. Proprietary 2010 ANSYS, Inc. All rights reserved.

Effect of Aspect Ratio on Laminar Natural Convection in Partially Heated Enclosure

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

APPLICATION OF DATA MINING TECHNIQUES FOR BUILDING SIMULATION PERFORMANCE PREDICTION ANALYSIS.

Radiant Heating and Cooling Systems BY KWANG WOO KIM, ARCH.D., MEMBER ASHRAE; BJARNE W. OLESEN, PH.D., FELLOW ASHRAE

Performance Estimation of Water Thermal Energy Storage Tank by Using Simplified Simulation

EVALUATION OF PHOENICS CFD FIRE MODEL AGAINST ROOM CORNER FIRE EXPERIMENTS

Comparison between purely statistical and multi-agent based approaches for occupant behaviour modeling in buildings

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

2013 Code_Saturne User Group Meeting. EDF R&D Chatou, France. 9 th April 2013

Natural convection in a room with two opposite heated vertical walls

Trace Layer Import for Printed Circuit Boards Under Icepak

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Introduction to CFD Analysis

Essam E. Khalil

NUMERICAL INVESTIGATION OF HEAT AND MASS TRANSFER IN A REFRIGERATED TRUCK COMPARTMENT

Ampacity simulation of a high voltage cable to connecting off shore wind farms

CFD SIMULATION OF IPR-R1 TRIGA SUBCHANNELS FLUID FLOW

CFD AND MULTI-ZONE MODELLING OF FOG FORMATION RISK IN A NATURALLY VENTILATED INDUSTRIAL BUILDING

Laminar Flow and Heat Transfer of Herschel-Bulkley Fluids in a Rectangular Duct; Finite-Element Analysis

HEAT TRANSFER IM LECTURE HOURS PER WEEK THERMODYNAMICS - IM _1

How To Calculate Thermal Resistance On A Pb (Plastipo)

CFD Application on Food Industry; Energy Saving on the Bread Oven

Pragmatic multi-scale and multi-physics analysis of Charles Bridge in Prague

Piotr Tofiło a,*, Marek Konecki b, Jerzy Gałaj c, Waldemar Jaskółowski d, Norbert Tuśnio e, Marcin Cisek f

EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS

Effect of design parameters on temperature rise of windings of dry type electrical transformer

THERMAL STRATIFICATION IN A HOT WATER TANK ESTABLISHED BY HEAT LOSS FROM THE TANK

A numerical investigation on effects of ceiling and floor surface temperatures and room dimensions on the Nusselt number for a floor heating system

Olivier Gicquel, Ronan Vicquelin, Jean Taine Phd Students : Y. Zhang, J. Kim, G. Wang, R. Goncalves dos Santos

INTERACTION OF LIQUID MOTION ON MOBILE TANK STRUCTURE

Thermal environment in indoor spaces with under-floor air distribution systems: 1. Impact of design parameters (1522-RP)

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

CFD Analysis of Application of Phase Change Material in Automotive Climate Control Systems

Experimental method to determine the energy envelope performance of buildings

CFD Grows Up! Martin W. Liddament Ventilation, Energy and Environmental Technology (VEETECH Ltd) What is Computational Fluid Dynamics?

Keywords: Heat transfer enhancement; staggered arrangement; Triangular Prism, Reynolds Number. 1. Introduction

INDOOR ENVIRONMENT OF A CLASSROOM IN A PASSIVE SCHOOL BUILDING WITH DISPLACEMENT VENTILATION. Applied Energy Research, Munich, Germany

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

Rate of Heating Analysis of Data Centers during Power Shutdown

Numerical Analysis of the Resin Transfer Molding Process via PAM- RTM Software

Crawl space heat and moisture behaviour

Lecture 3 Fluid Dynamics and Balance Equa6ons for Reac6ng Flows

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

Introduction to CFD Analysis

Modeling and Simulation of Oil-Water Flows with Viscous Fingering in Heterogeneous Porous Media.

Energy and Buildings

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Passive Solar Design and Concepts

MODELLING SUPPLY-AIR WINDOW IN A BUILDING SIMULATION CODE

Adaptive strategies for office spaces in the UK climate

SBi 2013:12. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

Everline Module Application Note: Round LED Module Thermal Management

Radiant Floor Heating In Theory and Practice

Moisture Content in Insulated Basement Walls

How To Model With Cfd Using Phoenics

NUCLEAR ENERGY RESEARCH INITIATIVE

Life Cycle Assessment applied to urban settlements

Post-insulation of cellar ceiling and cellar walls

Effects of Cell Phone Radiation on the Head. BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes

The calculus and simulation of underfloor heating systems

STUDY OF DAM-RESERVOIR DYNAMIC INTERACTION USING VIBRATION TESTS ON A PHYSICAL MODEL

AN EFFECT OF GRID QUALITY ON THE RESULTS OF NUMERICAL SIMULATIONS OF THE FLUID FLOW FIELD IN AN AGITATED VESSEL

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

Battery Thermal Management System Design Modeling

Transcription:

Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001 SIM_ZONAL: SOFTWARE EVALUATING INDOOR TEMPERATURE DISTRIBUTIONS AND AIR MOVEMENTS FOR RAPID APPRAISALS - FIRST APPLICATION TO AN CELL. Francis Déqué and Françoise Evin EDF Recherches et Développements, Département ADE B Les Renardières, Route de Sens, 77818 Moret sur Loing, France. Etienne Wurtz and Laurent Mora LEPTAB, Université de la Rochelle, 17042 La Rochelle cedex 1, France. ABSTRACT This article presents the first application of the Sim_Zonal software, a tool for evaluating indoor temperature and air flow distributions for residential and office buildings. The aim of this EDF (Electricity of France) software developed with the LEPTAB (University of La Rochelle) is to evaluate comfort problems and specially risks of discomfort (risk of draught, indoor gradient temperature, etc..) for rapid technical appraisals. The tool development - under Windows 95 - is in progress. In this paper we present our first application : an evaluation of the air temperature distribution in an cell heated with a heated floor. INTRODUCTION Sim_Zonal simulates the thermal and air flow exchanges inside a room in order to determine comfort conditions. It is a 3-dimensional simulation tool designed to appraise the quality of thermal environments within the framework of short-term studies lasting less than a week. In this article, we first briefly present the models developed in Sim_Zonal. These models are based on the following choices: the zonal method [1,2,3] is used to represent the air flows in the room, the heat exchanges by radiation are modeled by the Walton's method [4] and the heat exchanges by conduction are described with a finite differences model, reduced by Moore s method [5]. The software is then presented through the modeling of a cell 15 m 2 in area provided with a heated floor. MODELING ASSUMPTIONS The detail of the models used in Sim_Zonal is described in the reference document [6]. The main modeling assumptions are presented in the following paragraph. Zonal models The principle of the zonal method is to divide the room considered into a number of cells in which are calculated the air flow characteristics which are assumed to be constant (temperature, pressure, density, etc.). Mass and energy transfers are determined between the different zones. The division s macroscopic character is compensated by an as accurate as possible description of driving airflows. With dominant airflows, specific laws are applied; outside this range the laws are simplified as far as possible to limit calculation times [7]. To analyze the various mass and energy transfers in lowspeed zones, a pressure zonal model is considered (pressure varies hydrostatically). The laws used are then derived from mass, movement quantity and energy conservation equations. The variables of the problem are the temperature, the pressure and the density at the center of each cell, as well as the density of heat flows exchanged between one cell and its neighbors. In the dominant flow zones, equations are added describing the thermal plumes and boundary layers. Conduction models The proposed model is an approximation using the finite differences method. To reduce the system, Moore s reduction method [5] is applied. The conduction phenomena in the walls are described in dynamic mode: C. T =A.T+E.U Phi_Cond=H.T+D.U A system reduced to order 2 is obtained by applying Moore s method. - 251 -

Radiation models The system of equations accurately describing the heat exchanges through radiation is non-linear. It was thus decided to simplify the radiation flow calculation expression, in order to make it linear and thus consistent with the other models used. For this purpose, the fictitious enclosure method proposed by Walton [4] is used. Its principle is to consider that this area i exchanges with a single fictitious gray area associated with it. CELL DESCRIPTION This cell with an area of 15 m 2 is representative of an office or a bedroom. Its dimensions are 2.90 m x 5.15 m x 2.50 m (in the West-East, South-North and Top- Bottom directions); the window is located on the North wall and the door on the South wall. The plane is shown in Figure 1. In our study, the cell is heated by a heated floor. The area of the South wall is 7.25 m and the area of the West wall is 12.875 m2. Outside walls The outside walls are in contact with a seal (G11 and G2) and are well insulated. Their composition from the inside of the cell to the outside is: 10 mm plasterboard 50 mm polystyrene 200 mm Siporex Ceiling The ceiling has the following composition: 13 mm plasterboard 100 mm rock wool liquid seal system Floor Floor composition: 50 mm concrete heating electric cables 50 mm floormate 200 liquid floor Door The door has a thermal resistance of 1 m 2. C/W and its dimensions are 2m x 1m (2m 2 ). Window Figure 1: Cell description Composition and characteristics of walls Inside walls These are the walls in contact with soft seals G1 and G3. They are little insulated and their composition from the inside of the cell to the outside is: 26 mm plasterboard 108 mm rock wool 26 mm plasterboard G3 The window has double-glazing, its dimensions are 1.2m x 1.25m (1.5 m2) and its statutory characteristics are AC2-TH5. CALCULATION OF BOUNDARIES CONDITIONS The cable heating power and the temperatures outside the cell are considered as boundaries conditions. They are pre-calculated using an energy code (see figure 2). In our case, we used an air node model (single-node model). This initial simulation determined, on an hourly basis, the power delivered by the heated floor in order to obtain an ambient temperature of 19 C. The exchange coefficients are taken to be equal on either side of the wall and their value is 9.1 W/m2. C - 252 -

500 400 300 200 100 0 Power delivered by the heating floor 0 100 200 300 400 500 600 700 800 Time(h) Figure 2: boundaries conditions for calculating the flux delivered by the transmitter. The spatial distribution seems correct. The distribution in Bottom/Top temperatures is consistent (see Figure 5). The temperature of the lower center cell is higher than that of the center and upper zones. The temperatures of the sub-volumes in contact with a seal at 19 C are higher than those in contact with the outside temperature (see Figure 6). The simulation time is short: less than 30 seconds for this simulation over a complete month. SIM_ZONAL USER INTERFACE In our application, the room was meshed into 18 subvolumes (see figure 3). The set of data required for the simulation, with the exception of the composition of the walls, was entered through a graphics interface. Temperature ( C) 25 20 15 10 5 0-5 -10 Temperature variation below 1 C around 19 C 0 200 400 600 800 Time (h) Outside temperature Figure 4: Temperature variations in the cell. Figure 3: Entering the mesh ANALYSIS OF THE SIMULATION The simulation was carried out in October in Trappes (near Paris). The initial results obtained are satisfactory. We regulated at 19 C tell with the single-node model (boundaries conditions). We obtained an average temperature of 19.1 C with our 18-nodes zonal model. The distribution of temperatures over the simulation period is consistent (see figure 4), i.e. less than a degree different from the maximum temperatures. This result corresponds to the temperatures obtained with an heated floor. Temperature ( C) 19.65 19.6 19.55 19.5 19.45 19.4 19.35 19.3 19.25 19.2 19.15 0 100 200 300 400 500 600 Time (h) Figure 5: Temperature variations in the three air volumes located in the center zone. The results of figure 6 shows cross-section planes obtained in the cell. They represent the spatial distribution of the temperatures and flow rates at a given time in the simulation (Mid-October at 3 pm). bottom middle top - 253 -

Plan2 Plan 1 Plan 0 Figure 7.2: Spatial distribution of the temperature fields Cross-section plan 1. Figure 6: Cross-section planes The spatial distribution of the temperatures is shown in figures 7.1, 7.2 and 7.3. The zones in contact with the outside walls (right-hand part of the crosssections) are colder than those in contact with the seals at 19 C. Plane 2, whose North wall is in contact with the outside temperature, is also colder than the other planes. Figure 7.3: Spatial distribution of the temperature fields Cross-section plan 2. Figure 7.1: Spatial distribution of the temperature fields Cross-section plan 0. CONCLUSION In this article, we present the initial results obtained using the SIM_ZONAL calculation code. This software will give an estimation of a room s thermal comfort for rapid appraisal (less than 30 seconds for a month simulation). Indeed, an estimation of the risk of non-comfort may be calculated using the different temperatures and the air flow rates. Then parameters such as the head/foot temperature gradient or the risk of draught may be determined. Forthcoming developments will concern the integration of various transmitter models (convectors, ventilo-convector, split, etc.), the addition of the post-processing module specific to comfort (PMV, PPD calculation) and a validation based on comparisons against CFD codes and experimental measurements. - 254 -

REFERENCES [1] F. ALLARD and C.INARD. Natural and mixed convection in rooms : prediction of thermal stratification and heat transfer by zonal models, 1992 Int. Symp. on Room Air Convection and Ventilation Effectiveness, ISRACVE, Tokyo (Japan), 22-24 July 1992. [2] E. WURTZ. Modélisation tridimensionnelle des transferts thermiques et aérauliques dans le bâtiment en environnement orienté objet, Thèse de Doctorat, Ecole Nationale de Ponts et Chaussées, 1995. [3] M. MUSY. Génération automatique de modèles zonaux pour la description du comportement thermoaéraulique des bâtiments, Thèse de Doctorat, Université de La Rochelle, 1999. [4] G.N. WALTON. A new algorithm for radiant exchange in room loads calculations. A.S.H.R.A.E. Transactions, vol 86, Part II p190-208, 1988 [5] F.DEQUE, S. DELILLE, S.DAUTIN, Réduction de systèmes linéaires par la méthode Moore : Application la thermique du bâtiment, Rev. Gén. de Thermique, n 36, 1997. [6] E. WURTZ, F. DEQUE, M. MUSY, L. MORA, A thermal and air flow analysis tool using simplified models based on the zonal method, Clima 2000, Napoly, Sept 2001. [7] E. WURTZ, M. MUSY, F. ALLARD. Modélisation d un panache d émetteur de chaleur pour le logiciel de simulation énergétique des bâtiments SPARK, Int. J Therm. Sci n 39(3) pp433-441, 2000. NOMENCLATURE C: the matrix of calorific, diagonal capacities defined as positive, A: the symmetrical but not positive matrix of the heat exchanges internal to the domain, E: the rectangular matrix of the thermal connections between the domain and the outside, H, D: vectors applied to the field of temperatures. T(t): field of temperatures inside the walls. Ph_Cond(t): Conduction flow (Watt) through the wall. U(t): Vector of loads. (temperatures outside and inside the walls) - 255 -

- 256 -