Softstart. Changing of Printed Circuit Board PS S18-300. General...2 Please note!... 2



Similar documents
Softstart. Changing of Printed Circuit Board, Display, Keypad and upgrade to Torque control PSTB Contents. 1. ESD Warning Tools...

Softstart. Upgrade to Torque control PSTB Contents. 1. ESD Warning Tools PCB information Step by step...

BUILDING INSTRUCTIONS


73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Relay mounting systems

Installation Questions

Xenon HID Lighting System

Mobile Device Power Monitor Battery Connection Quick Start Guide

Hanson Learning Bale Tie Controller

Basic voltmeter use. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

SYSTEM 4C. C R H Electronics Design

Small form factor bay converter and hard drive installation

Model 1756 Test Lead Kit

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

Electricity and Power Supplies Chapter #4

In this section we tell you how to set the fault mode selection plug, key your I/O chassis, install your module and make your wiring connections.

AIR CONDITIONING SYSTEMS

T7560A,B,C Digital Wall Module

SYSTEM 45. C R H Electronics Design

HM-W536 Install Guide

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

VOIP-500 Series Phone Quick Installation Guide

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

ST Series POWER SUPPLIES USER INSTRUCTIONS

conventional system operation

Replacing the Gateway M675 Keyboard

HMI display Installation Guide

Pololu 5V, 600mA Step-Down Voltage Regulator D24V6F5

Teleservice via RS232 interface XC100/XC200

Packard Bell Easy Repair

Monitor Characteristics

Technical Support Information No. 113 Revision 2.0 March 2005

Power Supplies. Overview. Measuring Electricity. Understanding Electricity. Two Types of Current. Powering the PC

RS Monitor Backlight Replacement

Yoke harness color code: Horizontal: Red & Blue. Vertical: Yellow & Brown, or Yellow & Green, or Violet and Brown.

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Robot Board Sub-System Testing. Abstract. Introduction and Theory. Equipment. Procedures. EE 101 Spring 2006 Date: Lab Section # Lab #6

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Refer installation of power supplies to qualified service personnel.

Waveguide Access Point WGA631. Product Guide

Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un.

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

CutMaster Major External Replacement Parts

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

About the HotWire Slot Standalone Shelf

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

14. Troubleshooting Guide

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

EasyNote TJ Series. Disassembly Manual

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

CutMaster Major External Replacement Parts

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

Replacing the Gateway M320 Keyboard

Cable Discharge Event

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Alternator Identification

I Click on a link tab to jump to that page. Cover Page

Tyan Computer. Transport PX22. Service Engineer s Manual

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

PSR The compact range Description

LDG DTS-4/4R Desktop Coaxial Switch / Remote

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

3PH2 or 3PHE 3 Phase Control Board

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Hard Disk Drive (HDD)

WORLDWIDE. GW400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

I Click on a link tab to jump to that page. Cover Page

Kawasaki Vulcan 1500 Mean Streak Installation Instructions

DMX2PWM 9 Channel Dimmer Setup Manual

The following components are common to most cubicles; this example is an ABB HK cubicle.

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Disassembly of Waste Electrical and Electronic Equipment (WEEE) Manual

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

AC-DC Converter Application Guidelines

Manual IB-3620 Series

ELECTRONIC BOARDS - SUPRA

I Click on a link tab to jump to that page. Cover Page

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

ABB Drives. User s Manual HTL Encoder Interface FEN-31

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

OPT SERIAL TO FIBER OPTIC CONVERTER

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Installation, operation and maintenance manual TX 35A

OPLC Installation Guide

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Table Of Contents

Transcription:

Softstart Changing of Printed Circuit Board PS S18-300 5309 704-1 Rev E Juli-06 General...2 Please note!... 2 Identify the Printed Circuit Board that is going to be replaced...2 Replacing an older PCB marked Rev 10 or older (for 690V Rev H or older)...3 Step by step.... 3 Replacing a PCB marked Rev 11 up to revision H (Not valid for 690V)...4 Step by step.... 4 Replacing a PCB marked Rev I or later (also for 690V Rev I)...5 Step by step.... 5

General Please note! The life span of electronics can be affected by damage caused by electrostatic discharge. This can happen if a charged tool or person touches a component. Therefore it is very important that all tools and personnel are discharged, by touching an earthed point, before handling the printed circuit boards or any of the components. It is equally important to discharge the package with the new printed circuit board before opening it. A person walking on a carpet can be charged with up to fifteen thousand volt (15000V). Compare this with the fact that some sensitive components can be destroyed when discharged on a much lower level (about 100V). We kindly ask you to pay notice to this, as this is a vital point in order to ensure the life span of the product. Identify the Printed Circuit Board that is going to be replaced Please take a look on the backside of PCB. It can be two different type of markings. See examples, figure 1 and 2. Fig 1. Old marking including Rev 11 Fig 2. Newer revisions from Rev 12 and forward When the existing PCB (the one to be replaced) is identified, please look for where to start to read this instruction - 2 -

Start here if Replacing an older PCB marked Rev 10 or older (for 690V Rev H or older). These PCB have tabs (see Fig 3) as connectors for the gate wires and other internal connections. This chapter is valid if replacing the broken PCB it with the newest revision (rev I or later) of PCB. Then all the internal cable connectors have to be converted to fit on the new PCB. The needed connectors are enclosed in the new PCB package. Please note that the gate wires are connected differently on the new PCB.. Step by step. 1. Disconnect the voltage from terminals 1L1, 3L2 and 5L3 (main supply). 2. Disconnect all cables from the terminals 1 to.12. 3. Remove the front cover. 4. Discharge the tools and yourself by touching earth (if you are not earthed). 5. Remove the old PCB. Fig. 3. PCB with tabs. 6. Disconnect the cable on the PCB from the 7. Cut the old wires, and exchange the terminals for the gate wires, fan wires, and thermal switch to the new ones included in the package. 8. Discharge the package with the new PCB by moving it to earth. 9. Mount the cable on the PCB from the Mount also the connector for Supply Voltage. Please note that the gate wires have a new connection position - See colour marking Fig. 4. 10. Mount the new PCB. 11. Mount the front cover. 12. Connect the voltage and the other cable. Fig. 4. New PCB rev I or later. PS make sure that you are placing the jumper for supply voltage in the correct position, 110 120V or 220 240V. Make also sure that you have connect the cable from the thyristors correct DS Ready for start!! - 3 -

Start here if Replacing a PCB marked Rev 11 up to revision H (Not valid for 690V). These PCB have white colored connectors (see Fig.5) for the gate wires and other internal connections. This chapter is valid if replacing a broken PCB with a newer revision (rev I or later) of PCB. Please note that the gate cable connections are different on the new PCB, Check this following the cable colors in figure 6 below.. Step by step. 1. Disconnect the voltage from terminals 1L1, 3L2 and 5L3 (main supply). 2. Disconnect all cables from the terminals 1 to.12. 3. Remove the front cover. 4. Discharge the tools and yourself by touching earth (if you are not earthed). 5. Remove the old PCB. Fig. 5. Older PCB with connectors. 6. Disconnect the cable on the PCB from the 7. Discharge the package with the new PCB by moving it to earth. 8. Mount the cable on the PCB from the 13. Mount also the connector for Supply Voltage. Please note that the gate wires have a new connection position - See colour marking Fig. 6. 9. Mount the new PCB. 10. Mount the front cover. 11. Connect the voltage and the other cable. Fig. 6. New PCB rev I or later PS make sure that you are placing the jumper for supply voltage in the correct position, 110 120V or 220 240V. Also make sure that you have connected the cables from the thyristors in the correct position as it differ from the old PCB DS Ready for start!! - 4 -

Start here if Replacing a PCB marked Rev I or later (also for 690V Rev I) These PCB have white colored connectors (see Fig.7) for the gate wires and other internal connections. This part is valid if replacing a broken PCB with a new of PCB with the same revision or newer, Step by step. 1. Disconnect the voltage from terminals 1L1, 3L2 and 5L3 (main supply). 2. Disconnect all cables from the terminals 1 to.12. 3. Remove the front cover. 4. Discharge the tools and yourself by touching earth (if you are not earthed). 5. Remove the old PCB. 6. Disconnect the cable on the PCB from the 7. Discharge the package with the new PCB by moving it to earth. 8. Mount the cable on the PCB from the Mount also the connector for Supply Voltage. See Fig 6 9. Mount the new PCB. Fig. 7. New PCB rev I or later. 10. Mount the front cover. 11. Connect the voltage and the other cable. PS make sure that you are placing the jumper for supply voltage in the correct position, 110 120V or 220 240V. DS Ready for start!! - 5 -

ABB Automation Technologies, Cewe-Control S-721 61 Västerås, SWEDEN Telephone +46 21 32 07 00 TELEFAX +46 21 12 60 01-6 -