A-E99-- () HD Color Video Camera Command List Version. BRC-H9 Sony Corporation
Table of Contents VISCA RS-C/RS- Commands... Overview of VISCA... VISCA Communication Specifications... VISCA Device Setting Command... VISCA Command/ACK Protocol... VISCA Camera-Issued Messages... 8 BRC-H9 Commands... 9 BRC-H9 Command List (/)... 9 BRC-H9 Command List (/)... BRC-H9 Command List (/)... BRC-H9 Command List (/)... BRC-H9 Command List (/)... BRC-H9 Inquiry Command List (/)... BRC-H9 Inquiry Command List (/)... BRC-H9 Inquiry Command List (/)... BRC-H9 Block Inquiry Command List... VISCA Command Setting Values... Pan/Tilt Status Code List... Memory Function (Inquiry Commands)... 8 Revision History... 9
VISCA ) RS-C/RS- Commands Use of RS-C/RS- control software based upon this command list may cause malfunction or damage to hardware and software. Sony Corporation is not liable for any such damage. Overview of VISCA In VISCA, the side outputting commands, for example, a computer, is called the controller, while the side receiving the commands, such as a BRC-H9, is called the peripheral device. The BRC-H9 serves as a peripheral device in VISCA. In VISCA, up to seven peripheral devices like the BRC-H9 can be connected to one controller using communication conforming to the RS-C/RS- standard. The parameters of RS- C/RS- are as follows. Communication speed: 9 bps/8 bps Data bits : 8 Start bit : Stop bit : Non parity Flow control using XON/XOFF and RTS/CTS, etc., is not supported. Peripheral devices are connected in a daisy chain. As shown in Fig., the actual internal connection is a onedirection ring, so that messages return to the controller via the peripheral devices. The devices on the network are assigned addresses. The address of the controller is fixed at. The addresses of peripheral devices are as follows. Note In the same network, all the camera address selectors should be set to (automatic setting) or all the selectors should be manually set to to. Do not mix the automatic and manual settings. Each VISCA equipment has VISCA IN and VISCA OUT connectors. Set the DTR input (the S output of the controller) of VISCA IN to H when controlling VISCA equipment from the controller. VISCA Controller Fig. VISCA network configuration VISCA Equipment IN OUT IN OUT IN OUT When the camera address selector is set to (automatic setting mode) The peripheral devices are assigned to the addresses,,, in the connected order, starting from the one connected nearest to the controller. These addresses are set when the controller sends address commands during initialization of the network. When the camera address selector is set to through (manual setting mode) The addresses of the peripheral devices will be set to the pre-selected numbers. Within a single system, the same number can be used only once. If an address selector number other than is used, set the camera address selectors on the connected BRC-H9 cameras to different numbers.... ) VISCA is a protocol developed by Sony for controlling a consumer s camcorder. VISCA is a trademark of Sony Corporation.
VISCA Communication Specifications VISCA packet structure The basic unit of VISCA communication is called a packet (Fig. ). The first byte of the packet is called the header and comprises the sender s and receiver s addresses. For example, the header of the packet sent to the BRC-H9 assigned address from the controller (address ) is 8H in hexadecimal. The packet sent to the BRC-H9 assigned address is 8H. In the command list, as the header is 8X, input the address of the BRC- H9 to X. The header of the reply packet from the BRC-H9 assigned address is 9H. The packet from the BRC-H9 assigned address is AH. Some of the setting commands for BRC-H9 can be sent to all devices at one time (broadcast). In the case of broadcast, the header should be 88H in hexadecimal. When the terminator is FFH, it signifies the end of the packet. Packet ( to bytes) Header Message ( to bytes) Terminator Byte Byte Byte FF Sender s address Receiver s address Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) Bit Bit Bit Bit Bit Bit Bit Bit (MSB) (LSB) Note Fig. shows the packet structure, while Fig. shows the actual waveform. Data flow will take place with the LSB first. Fig. Packet structure byte Start bit Bit Bit Bit Bit Bit Bit (LSB) Bit Bit Stop bit. (MSB) Fig. Actual waveform for byte. Timing Chart As VISCA command processing can only be carried out a maximum of one time in a Vertical (V*) cycle, it takes maximum V-cycle time for an ACK/Completion to be returned. If the Command and ACK/Completion communication time is shorter than V-cycle time, a command can be received at every V cycle. From this point, if two or more commands are to be sent successively, wait for a reply command (an ACK or error message for a general command, and an inquiry packet for an inquiry command) of the previous command to be received before sending the next command. *V=. msec (NTSC, 8/9.9i, /9.9p), msec (PAL, 8/ i, /p) General commands Command RxD TxD Within V Inquiry commands Within V Command RxD TxD ACK Completion Inquiry Packet Bytes
Command and inquiry Command Sends operational commands to the BRC-H9. Inquiry Used for inquiring about the current state of the BRC- H9. Command Packet Note Inquiry 8X QQ RR... FF QQ ) = Command/Inquiry, RR ) = category code ) QQ = (Command), 9 (Inquiry) ) RR = (Interface), (camera ), (Pan/Tilter) X = to : BRC-H9 address For actual values to be sent, see Command Lists or Inquiry Command Lists. Responses for commands and inquiries ACK message Returned by the BRC-H9 when it receives a command. No ACK message is returned for an inquiry. Completion message Returned by the BRC-H9 when execution of commands or inquiries is completed. In the case of inquiry commands, reply data for the inquiry is contained after the rd byte of the packet. If the ACK message is omitted, the socket number will contain. Reply Packet Note Ack X Y FF Y = socket number Completion (Commands) X Y FF Y = socket number Completion (Inquiries) X Y... FF Y = socket number X = 9 to F: BRC-H9 address + 8 Error message When a command or inquiry command could not be executed or failed, an error message is returned instead of a completion message. Error Packet Description X Y FF Message length error X Y FF Syntax Error X Y FF Command buffer full X Y FF Command canceled X Y FF No socket (to be canceled) X Y FF Command not executable X = 9 to F: BRC-H9 address + 8, Y = socket number Socket number When command messages are sent to the BRC-H9, it is normal to send the next command message after receiving the completion message or error message. However, to deal with advanced uses, the BRC-H9 has two buffers (memories) for commands, so that up to two commands including the commands currently being executed can be received. (There is a wait longer than a V cycle between commands.) However, depending on the command, it may be necessary to wait until the first command is completed. When the BRC-H9 receives commands, it notifies the sender which command buffer was used, using the socket number of the ACK message. As the completion message or error message also has a socket number, it indicates which command has ended. Even when two command buffers are being used, a BRC-H9 management command and some inquiry messages can be executed. The ACK message is not returned for these commands and inquiries, and only the completion message of socket number is returned. Command execution cancel To cancel a command which has already been sent, send a Cancel command as the next command. To cancel one of two commands which have been sent, use the cancel message. Cancel Packet Note Cancel 8X Y FF Y = socket number X = to : BRC-H9 address, Y = socket number Error message Command canceled will be returned for this command, but this is not a fault. It indicates that the command has been canceled. Note To cancel a command when VISCA PAN-TILT Drive (page ) is being executed, wait at least msec after executing. Then send a cancel command to ensure that PAN-TILT Drive stops effectively. To execute a PAN-TILT Drive command again, wait at least msec after the message Command canceled has appeared.
VISCA Device Setting Command Before starting control of the BRC-H9, be sure to send the Address command and the IF_Clear command using the broadcast function. For VISCA network administration Address Sets an address of a peripheral device. Use when initializing the network, and receiving the following network change message. Network Change Sent from the peripheral device to the controller when a device is removed from or added to the network. The address must be re-set when this message is received. Packet Note Address 88 FF Always broadcasted. Network Change X 8 FF X = 9 to F: BRC-H9 address + 8 VISCA interface command IF_Clear Clears the command buffers in the BRC-H9. When cleared, the operation currently being executed is not guaranteed. Command Packet Reply Packet Note IF_Clear 8X FF X FF IF_Clear (broadcast) 88 FF 88 FF X = to : BRC-H9 address (For inquiry packet) X = 9 to F: BRC-H9 address +8 (For reply packet) VISCA interface and inquiry CAM_VersionInq Returns information on the VISCA interface. Inquiry Inquiry Packet Reply Packet Description CAM_VersionInq 8X 9 FF Y GG GG HH HH JJ JJ KK FF GGGG = Vender ID (: Sony) HHHH = Model ID : BRC-H : BRU-H : BRC-Z : BRC-Z B: BRC-H9 JJJJ = ROM revision KK = Maximum socket # () X = to : BRC-H9 address (For inquiry packet) X = 9 to F: BRC-H9 address +8 (For reply packet)
VISCA Command/ACK Protocol Command Command Message Reply Message Comments General Command 8 8 FF (Example) Inquiry Command 8 8 FF (Example) 8 8 FF (Example) 8 8 FF (Example) 8 9 8 FF (Example) 8 9 8 FF (Example) 9 FF (ACK)+9 FF (Completion) 9 FF 9 FF 9 FF (Syntax Error) 9 FF (Command Buffer Full) 9 FF (Command Not Executable) 9 FF * When the camera address selector is set to an address other than, the value x in 88 x FF will be variable. Do not transmit the command (except Address Set, IF_Clear, Command Cancel, POWER (page )) when any menu is displayed on the screen. If displayed, clear the menu first using MENU Display OFF (page ) Command, and then proceed. 9 FF (Completion) Does not return ACK. 9 FF (Syntax Error) Returns ACK when a command has been accepted, or Completion when a command has been executed. Accepted a command which is not supported or a command lacking parameters. Could not accept the command as there are two commands currently being executed. Could not execute the command in the current mode. Accepted an incompatible command. Address Set 88 FF 88 FF The device address number plus is returned.* IF_Clear 88 FF 88 FF The same command is returned. (Broadcast) IF_Clear (For x) 8x FF z FF (Completion) ACK is not returned for this command. Command Cancel 8x y FF z y FF (Command Canceled) z y FF (No Socket) Returned when the command of the socket specified is canceled. Completion for the command canceled is not returned. Returned when the command of the specified socket has already been completed or when the socket number specified is wrong.
VISCA Camera-Issued Messages ACK/Completion Messages Command Command Message Comments ACK z y FF Returned when the command is accepted. (y: Socket No.) Completion z y FF (y: Socket No.) Returned when the command has been executed. z = Device address + 8 Error Messages Command Command Message Comments Syntax Error z FF Returned when the command format is different or when a command with illegal command parameters is accepted. Command Buffer Full z FF Could not accept a command that is received while two commands are currently being executed (two sockets have been used). Command Canceled No Socket Command Not Executable z y FF (y: Socket No.) z y FF (y: Socket No.) z y FF (y: Socket No.) Network Change Message Returned when a command which is being executed in a socket specified by the cancel command is canceled. The completion message for the command is not returned. Returned when no command is executed in a socket specified by the cancel command, or when an invalid socket number is specified. Returned when a command cannot be executed due to current conditions. For example, when a command for controlling the manual focus is received during the auto focus mode. Command Command Message Comments Network Change z 8 FF Issued when power is supplied to the camera. 8
BRC-H9 Commands BRC-H9 Command List (/) Command Set Command Command Packet Comments EXPOSURE MODE FULL AUTO 8x 9 FF MANUAL 8x 9 FF SHUTTER Pri 8x 9 A FF IRIS Pri 8x 9 B FF BACK LIGHT 8x FF Available only when MODE is set to FULL SPOT LIGHT 8x A FF AUTO. IRIS Reset 8x B FF When EXPOSURE MODE is set to MANUAL or IRIS Pri, the setting is F.. Up (OPEN) 8x B FF Down 8x B FF (CLOSE) Direct 8x B p q FF pq: See the VISCA Command Setting Values (IRIS) section SHUTTER Reset 8x A FF When EXPOSURE MODE is set to MANUAL or SHUTTER Pri, the setting is / (for 8/ 9.9i, /9.9p). When EXPOSURE MODE is set to MANUAL or SHUTTER Pri, the setting is / (for 8/i, /p). Up (HIGH) 8x A FF Down (LOW) 8x A FF Direct 8x A p q FF pq: See the VISCA Command Setting Values (SHUTTER) section GAIN Reset 8x C FF When EXPOSURE MODE is set to MANUAL, the setting is db. Up 8x C FF Down 8x C FF Direct 8x C p q FF pq: See the VISCA Command Setting Values (GAIN) section AE SPEED Direct 8x D p FF p : LOW : MID : HIGH AE LEVEL Reset 8x E FF Up 8x E FF Down 8x E FF Direct 8x E p FF p : -. : -. : 8: +. 9: +. AGC ON/OFF 8x E p FF p : ON : OFF AGC LIMIT Direct 8x C p FF p : db : db : 9dB : db : 8dB AGC POINT Direct 8x E p FF p : F. : F : F.8 AUTO Direct 8x E p FF p : ON : OFF SHUTTER SHUTTER Direct 8x E 8 p FF p : / : / : / : / LIMIT SHUTTER POINT Direct 8x E 9 p FF p : F. : F8 : F : F 9
BRC-H9 Command List (/) Command Set Command Command Packet Comments COLOR WHITE BALANCE - 8x p FF p : AUTO : INDOOR : OUTDOOR : ONE PUSH : MANUAL One Push WB - 8x FF Trigger R.GAIN Reset 8x FF Up 8x FF Down 8x FF Direct 8x p q FF pq: (-8) - 8 () - FF (+) B.GAIN Reset 8x FF Up 8x FF Down 8x FF Direct 8x p q FF pq: (-8) - 8 () - FF (+) SPEED - 8x p FF p: (Slow),,,, (Fast) OFFSET Reset 8x E E FF Up 8x E E FF Down 8x E E FF Direct 8x E E p FF p: (-) - () - E (+) MATRIX - 8x E D p FF p: ON (STD) : OFF : ON (HIGH SAT) : ON (FL LIGHT) LEVEL Reset 8x 9 FF Up 8x 9 FF Down 8x 9 FF Direct 8x 9 p FF p: (-) - () - E (+) PHASE Reset 8x F FF Up 8x F FF Down 8x F FF Direct 8x F p q FF pq: (-99) - () - C (+99) R-G Direct 8x E A p q FF pq: (-99) - () - C (+99) R-B Direct 8x E B p q FF pq: (-99) - () - C (+99) G-R Direct 8x E C p q FF pq: (-99) - () - C (+99) G-B Direct 8x E D p q FF pq: (-99) - () - C (+99) B-R Direct 8x E E p q FF pq: (-99) - () - C (+99) B-G Direct 8x E F p q FF pq: (-99) - () - C (+99) DETAIL DETAIL ON/OFF 8x E p FF p : ON : OFF LEVEL Reset 8x FF Up 8x FF Down 8x FF Direct 8x p q FF pq: (-99) - () - C (+99) FREQUENCY Direct 8x E p q FF pq: (-99) - () - C (+99) CRISPENING Direct 8x E p q FF pq: (-99) - () - C (+99) H/V RATIO Direct 8x E p q FF pq: (-99) - () - C (+99) WHITE Direct 8x E p q FF pq: (-99) - () - C (+99) LIMITTER BLACK Direct 8x E p q FF pq: (-99) - () - C (+99) LIMITTER V DTL - 8x E p FF p: NAM : G : G+R : Y CREATION KNEE APT LEVEL Direct 8x E p q FF pq: (-99) - () - C (+99) * Number in ( ) is MENU display values.
BRC-H9 Command List (/) Command Set Command Command Packet Comments COLOR DETAIL COLOR DETAIL - 8x E 8 p FF p : ON : OFF LEVEL Direct 8x E 9 p q FF pq: (-99) - () - C (+99) AREA INDICATION - 8x E A p FF p : ON : OFF SATURATION Direct 8x E B p q FF pq: (-99) - () - C (+99) PHASE Direct 8x E D p q r FF pqr: - (h) WIDTH Direct 8x E C p q FF pq: () - 8 () - A (9) KNEE MODE - 8x E D p FF p : ON : OFF AUTO KNEE - 8x E p FF p : Auto : Off POINT Direct 8x E E p q FF pq: () - A (9) - D (9) SLOPE Direct 8x E F p q FF pq: (-99) - () - C (+99) KNEE SAT Direct 8x E p q FF pq: () - () - (+99) LEVEL GAMMA MODE - 8x B p FF p: STD : CINEMA : STD : STD : STD : CINEMA : CINEMA : CINEMA LEVEL Direct 8x E p q FF pq: (-99) - () - C (+99) BLACK Direct 8x E p q FF pq: (-99) - () - C (+99) BLACK GAMMA Direct 8x E p q FF pq: (-99) - () - C (+99) FLICKER CANCEL MODE - 8x p FF p : ON : OFF FREQUENCY - 8x E p FF : Hz : Hz FOCUS MODE ON/OFF 8x 8 p FF p : Auto : Manual Except ON/ 8x 8 FF OFF One Push AF Trigger - 8x 8 FF FOCUS - 8x 8 FF PAN TILT PAN TILT Limit Limit Set 8x W Yp Yq Yr Ys Yt Zp Zq Zr Zs FF W: =UpRight =DownLeft Yp Yq Yr Ys Yt Zp Zq Zr Zs: See Pan/Tilt Position (for reference) in the VISCA Command Setting Values section Limit Clear 8x W F F F F F F F FF RAMP CURVE - 8x p FF p: MODE MODE SYSTEM IR RECEIVE - 8x 8 pq FF pq: ON OFF ON/OFF Toggle movement IMG FLIP - 8x p FF p: ON : OFF RAN REVERSE - 8x E p FF p: ON : OFF TILT REVERSE - 8x E 9 p FF p: ON : OFF DISPLAY INFO - 8x E 8 p FF p: ON : OFF SYNC MASTER - 8x E C p FF p: HD : SD HPHASE Up 8x E E FF Down 8x E E FF Direct 8x E B p q r FF pqr: - BF STEADY SHOT - 8x pq FF p: ON : OFF COLOR BAR - 8x D p FF p: ON : OFF TALLY MODE - 8x E A q FF q: OFF : ON (LOW) : ON (HIGH)
BRC-H9 Command List (/) Command Set Command Command Packet Comments VIDEO OUT D-SUB - 8x E p FF p: RGB : YPbPr FORMAT ADD - 8x E p FF p: RGB SYNC OFF : RGB SYNCON SYNC(RGB) SYNC TYPE - 8x E A p FF p: -state SYNC : VD IMG SIZE - 8x E C p FF p: : [SQUEEZE] : 9 [LETTER] : [CROP] SETUP - 8x E F p FF p: ON (.IRE) : OFF (IRE) POWER ON/OFF - 8x p FF p: ON : OFF PRESET Drive Speed - - 8x E B p qq FF p: Preset number of speed setting - (-F) qq: p position direction speed -8 (h) TALLY ON/OFF - 8x E A p FF PAN-TILT Drive Up - 8x VV WW FF VV: PAN speed -8 (h) Down - 8x VV WW FF WW: TILT speed -8 (h) Left - 8x VV WW FF Right - 8x VV WW FF UpLeft - 8x VV WW FF UpRight - 8x VV WW FF DownLeft - 8x VV WW FF DownRight - 8x VV WW FF Stop - 8x VV WW FF ABS (Absolute - 8x VV Yp Yq Yr VV: Speed -8 (h) Position) Ys Yt Zp Zq Zr Zs FF REL (Relative Position) - 8x VV Yp Yq Yr Ys Yt Zp Zq Zr Zs FF Yp Yq Yr Ys Yt Zp Zq Zr Zs: See Pan/Tilt Position (for reference) in the VISCA Command Setting Values section Home - 8x FF Reset - 8x FF CAMERA ID Setting - - 8x p q r s FF pqrs: - FFFF TITLE Display (Preset Position) Title Set - 8x E uu vv w! FF Title Set - 8x E! aa bb cc dd ee ff gg hh ii jj FF Title Set - 8x E! kk ll mm nn oo pp qq rr ss tt FF uu: Character start position display, H position -A vv: Character start position display, V position -D w: Blinking character display ON, OFF!: Preset number of character display - -F!: Preset number of character display - -F aa bb cc dd ee ff gg hh ii jj: First characters setting (ASCII CODE x-xe)!: Preset number of character display - -F kk ll mm nn oo pp qq rr ss tt: Last characters setting (ASCII CODE x-xe) Title Clear - 8x E! FF!: Preset number of character display - -F Title On - 8x E FF Title Off - 8x E FF
BRC-H9 Command List (/) Command Set Command Command Packet Comments TITLE Display (Standard) Title Set - 8x E uu vv w FF uu: Character start position display, H position -A vv: Character start position display, V position -D w: Blinking character display ON, OFF Title Set - 8x E aa bb cc dd ee ff gg hh ii jj FF aa bb cc dd ee ff gg hh ii jj: First characters setting (ASCII CODE x-xe) Title Set - 8x E kk ll mm nn oo pp qq rr ss tt FF kk ll mm nn oo pp qq rr ss tt: Last characters setting (ASCII CODE x-xe) Title Clear - 8x E FF Title On - 8x E FF Title Off - 8x E FF MENU Display - - 8x FF OFF PRESET Set - 8x F p FF Reset - 8x F p FF Recall - 8x F p FF p: Preset number - -F Zoom Stop - 8x FF Tele (Standard - 8x FF Speed) Wide (Standard - 8x FF Speed) Tele (Variable - 8x p FF p: (Slow) to (Fast) Speed) Wide (Variable - 8x p FF Speed) Direct - 8x p q r s FF pqrs: See the VISCA Command Setting Values (ZOOM) section FOCUS Stop - 8x 8 FF Far (Standard - 8x 8 FF Speed) Near (Standard - 8x 8 FF Speed) Far (Variable - 8x 8 p FF p: (Slow) to (Fast) Speed) Near (Variable - 8x 8 p FF Speed) Direct - 8x 8 p q r s FF pqrs: See the VISCA Command Setting Values (FOCUS) section BRBK-SA Command D-SUB 9Pin OUT - 8x E p q FF p: Main Unit Card Slot BRU-SF Card Slot BRU-SF Card Slot q: RGB YCbCr D-SUB 9Pin OUT - 8x E p q FF p: Main Unit Card Slot BRU-SF Card Slot BRU-SF Card Slot q: Y/C VBS RGB SYNC - 8x E p q FF p: Main Unit Card Slot BRU-SF Card Slot BRU-SF Card Slot q: SYNC OFF SYNC ON RGB IMG SIZE - 8x E p q FF p: Main Unit Card Slot BRU-SF Card Slot BRU-SF Card Slot q: : [SQUEEZE] : 9 [LETTER] : [CROP] SETUP - 8x E B p q FF p: Main Unit Card Slot BRU-SF Card Slot BRU-SF Card Slot q: ON (.IRE) OFF (IRE) BRBK-HSD Command IMG SIZE - 8x E p q FF p: Main Unit Card Slot BRU-SF Card Slot BRU-SF Card Slot q: : [SQUEEZE] : 9 [LETTER] : [CROP]
BRC-H9 Inquiry Command List (/) Inquiry Command Command Packet Inquiry Packet Comments EXPOSURE MODE FULL AUTO IRIS Pri SHUTTER Pri MANUAL Inquiry 8x 9 9 FF y p FF p: FULL AUTO MANUAL A SHUTTER Pri B IRIS Pri COLOR BACK LIGHT ON/ 8x 9 FF y p FF p: ON : OFF OFF Inquiry SPOT LIGHT ON/ 8x 9 A FF y p FF p: ON : OFF OFF Inquiry IRIS - 8x 9 B FF y p q FF pq: See the VISCA Command Setting Values (IRIS) section SHUTTER - 8x 9 A FF y p q FF pq: See the VISCA Command Setting Values (SHUTTER) section GAIN - 8x 9 C FF y p q FF pq: See the VISCA Command Setting Values (GAIN) section AE SPEED - 8x 9 D FF y p FF p : LOW : MID : HIGH AE LEVEL - 8x 9 E FF y p FF p : -. : -. : 8: +. 9: +. AGC ON/OFF Inquiry 8x 9 E FF y p FF p: ON : OFF AGC LIMIT - 8x 9 C p FF y p FF p : db : db : 9dB : db : 8dB AGC POINT - 8x 9 E FF y p FF p : F. : F : F.8 AUTO SHUTTER - 8x 9 E FF y p FF p : ON : OFF SHUTTER LIMIT SHUTTER POINT WHITE BALANCE * Number in ( ) is MENU display values. - 8x 9 E 8 FF y p FF p : / : / : / : / - 8x 9 E 9 FF y p FF p : F. : F8 : F : F MODE Inquiry 8x 9 FF y p FF R.GAIN - 8x 9 FF y p q FF B.GAIN - 8x 9 FF y p q FF SPEED - 8x 9 FF y p FF OFFSET - 8x 9 E E FF y p FF p: (-) - () - E (+) MATRIX - 8x 9 E D FF y p FF LEVEL - 8x 9 9 FF y p FF p: (-) - () - E (+) PHASE - 8x 9 F FF y p FF pq: (-99) - () - C (+99) R-G - 8x 9 E A FF y p FF pq: (-99) - () - C (+99) R-B - 8x 9 E B FF y p FF pq: (-99) - () - C (+99) G-R - 8x 9 E C FF y p FF pq: (-99) - () - C (+99) G-B - 8x 9 E D FF y p FF pq: (-99) - () - C (+99) B-R - 8x 9 E E FF y p FF pq: (-99) - () - C (+99) B-G - 8x 9 E F FF y p FF pq: (-99) - () - C (+99)
BRC-H9 Inquiry Command List (/) Inquiry Command Command Packet Inquiry Packet Comments DETAIL DETAIL - 8x 9 E FF y p FF LEVEL - 8x 9 FF y p q FF pq: (-99) - () - C (+99) FREQUENCY - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) CRISPENING - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) H/V RATIO - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) WHITE - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) LIMITTER BLACK - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) LIMITTER V DTL - 8x 9 E FF y p FF p: NAM : G : G+R : Y CREATION KNEE APT LEVEL - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) COLOR DETAIL COLOR - 8x 9 E 8 FF y p FF p : ON : OFF DETAIL LEVEL - 8x 9 E 9 FF y p q FF pq: (-99) - () - C (+99) AREA INDICATION - 8x 9 E A FF y p FF p : ON : OFF SATURATION - 8x 9 E B FF y p q FF pq: (-99) - () - C (+99) PHASE - 8x 9 E D FF y p q FF pqr: - WIDTH - 8x 9 E C FF y p q FF pq: () - 8 () - A (9) KNEE MODE - 8x 9 E D FF y p FF p : ON : OFF AUTO KNEE - 8x 9 E FF y p FF p : Auto : Off POINT - 8x 9 E E FF y p q FF pq: () SLOPE - 8x 9 E F FF y p q FF pq: (-99) - () - C (+99) KNEE SAT - 8x 9 E FF y p q FF pq: () - () - (+99) LEVEL GAMMA MODE - 8x 9 B FF y p FF p: STD : CINEMA : STD : STD : STD : CINEMA : CINEMA : CINEMA LEVEL - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) BLACK - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) BLACK GAMMA - 8x 9 E FF y p q FF pq: (-99) - () - C (+99) FLICKER CANCEL MODE - 8x 9 FF y p FF p : ON : OFF FREQUENCY - 8x 9 E FF y p FF p : Hz : Hz FOCUS MODE - 8x 9 8 FF y p FF p : Auto : Manual PAN TILT RAMP - 8x 9 FF y p FF p: MODE MODE CURVE SYSTEM IR RECEIVE - 8x 9 8 FF y p FF p: ON : OFF IMG FLIP - 8x 9 FF y p FF p: ON : OFF RAN - 8x 9 E FF y p FF p: ON : OFF REVERSE TILT - 8x 9 E 9 FF y p FF p: ON : OFF REVERSE DISPLAY - 8x 9 E 8 FF y p FF p: ON : OFF INFO SYNC - 8x 9 E C FF y p FF p: HD : SD MASTER HPHASE - 8x 9 E E FF y p q r FF pqr: - BF STEADY - 8x 9 FF y p FF p: ON : OFF SHOT COLOR BAR - 8x 9 D FF y p FF p: ON : OFF
BRC-H9 Inquiry Command List (/) VIDEO OUT BRBK- SA BRBK- HSD POWER Status CAMERA Software Version PRESET Drive Speed Inquiry Command Command Packet Inquiry Packet Comments D-SUB - 8x 9 E FF y p FF p: RGB : YPbPr FORMAT ADD - 8x 9 E FF y p FF p: RGB SYNC OFF : RGB SYNC(RGB) SYNCON SYNC TYPE - 8x 9 E A FF y p FF p: -state SYNC : VD IMG SIZE - 8x 9 E C FF y p FF p: : [SQUEEZE] : 9 [LETTER] : [CROP] SETUP - 8x 9 E F FF y p FF p: ON (.IRE) : OFF (IRE) D-SUB 9Pin - 8x 9 E p FF y q FF p: Main Unit Card Slot BRU- OUT SF Card Slot BRU-SF Card Slot q: RGB YCbCr D-SUB 9Pin OUT - 8x 9 E p FF y q FF p: Main Unit Card Slot BRU- SF Card Slot BRU-SF Card Slot q: Y/C VBS RGB SYNC - 8x 9 E p FF y q FF p: Main Unit Card Slot BRU- SF Card Slot BRU-SF Card Slot q: SYNC OFF SYNC ON RGB IMG SIZE - 8x 9 E p FF y q FF p: Main Unit Card Slot BRU- SF Card Slot BRU-SF Card Slot q: : [SQUEEZE] : 9 [LETTER] : [CROP] SETUP - 8x 9 E B p FF y q FF p: Main Unit Card Slot BRU- SF Card Slot BRU-SF Card Slot q: ON (.IRE) OFF (IRE) IMG SIZE - 8x 9 E p FF y q FF p: Main Unit Card Slot BRU- SF Card Slot BRU-SF Card Slot q: : [SQUEEZE] : 9 [LETTER] : [CROP] ON/OFF - 8x 9 E FF y p FF p: ON : OFF Inquiry - - 8x 9 FF y mn pq rs tu vw FF mnpq: Model Code (xx) rstu: ROM version vw: Socket Number () - - 8x 9 E B p FF y qq FF p: Preset number of speed retrieving - (-F) qq: p position direction speed response -8 (h) TALLY - - 8x 9 E A FF y p FF p: ON : OFF PAN-TILT Position - - 8x 9 FF y Yp Yq Yr Ys Yt Zp Zq Zr Zs FF Yp Yq Yr Ys Yt Zp Zq Zr Zs: See Pan/Tilt Position (for reference) in the VISCA Command Setting Values section CAMERA - - 8x 9 FF y p q r s FF pqrs: ID ID TITLE ON/OFF - 8x 9 E FF y p FF p: ON : OFF (Preset Postion) Inquiry TITLE ON/OFF - 8x 9 E FF y p FF p: ON : OFF Display (Standard) Inquiry MENU ON/OFF - 8x 9 FF y p FF p: ON : OFF Display Status Inquiry PRESET - - 8x 9 F FF y p FF Return the last preset number which has been operated (VISCA parameters [-F]) Zoom - - 8x 9 FF y p q r s FF pqrs: See the VISCA Command Setting Values (ZOOM) section FOCUS - - 8x 9 8 FF y p q r s FF pqrs: See the VISCA Command Setting Values (FOCUS) section
BRC-H9 Block Inquiry Command List Lens control system inquiry commands..command Packet 8x 9 E E FF Destination Address Source Address Zoom Position (HH) Zoom Position (HL) Zoom Position (LH) Zoom Position (LL) 8 Focus Position (HH) 9 Focus Position (HL) Focus Position (LH) Focus Position (LL) Focus Mode (: Auto : Manual) Camera Memory Recall (: Executing : Stopped) Focus Command (: Executing : Stopped) Zoom Command (: Executing : Stopped)
Camera control system inquiry commands (/)..Command Packet 8x 9 E E FF Destination Address Source Address WB R Gain(H) WB R-Gain (L) WB B-Gain (H) WB B-Gain (L) COLOR SPEED ( - ) WHITE BALANCE MODE (: Auto : Indoor : Outdoor : Onepush : Manual) DETAIL SETTING (: Off : On) 8 9 EXPOSURE MODE (: Auto : Manual A: Shutter Pri B: Iris Pri) SPOT LIGHT MODE (: On : Off) BACK LIGHT MODE (: On : Off) EXPOSURE MODE Manual Shutter Position EXPOSURE MODE Manual Iris Position EXPOSURE MODE Manual Gain Position IMG FLIP MODE (: On : Off) AE LEVEL (:. :-. : 8: +. 9: +.) 8
Camera control system inquiry commands (/)..Command Packet 8x 9 E E FF Destination Address Source Address 8/ mode (: 8 : ) 9.9/ mode (: 9.9 : ) Camera status (: Power On : Sleep) COLOR OFFSET (-) - () - E (+) MATRIX (: On (STD) : OFF : ON (HIGH SAT) : ON (FL LIGHT) MATRIX COLOR LEVEL (-) - () - E (+) 8 9 STEADY SHOT (: On : Off) FLICKER CANCEL (: On : Off) FRECKER CANCEL FREQUENCY (: Hz : Hz) GAMMA MODE ( - ) COLOR PHASE (H) COLOR PHASE (L) AE SPEED (: Low : Mid : High) AGC MODE (: ON : OFF) AGC LIMIT (: db : db : 9dB : db : 8dB) Shutter Point (: F. : F8 : F : F) Shutter Limit (: / : / : / : /) Auto Shutter (: ON : OFF) AGC Point (: F. : F : F.8) R-G (H) R-G (L) 9
Other enlargement inquiry commands (/)... Command Packet 8x 9 E E FF Destination Address Source Address R-B (H) R-B (L) G-R (H) G-R (L) 8 9 G-B (H) G-B (L) B-R (H) B-R (L) Camera block FAN rotating status (: Rotating : Stop) COLOR DETAIL (: On : Off) Shutter Pri Position Iris Pri Position B-G (H) B-G (L)
Other enlargement inquiry commands (/)... Command Packet 8x 9 E E FF Destination Address Source Address Current R GAIN (H) Current R GAIN (L) Current B GAIN (H) Current B GAIN (L) 8 9 DETAIL LEVEL (H) DETAIL LEVEL (L) COLOR DETAIL AREA INDICATION (: ON : OFF) COLOR DETAIL LEVEL (H) COLOR DETAIL LEVEL (L) COLOR DETAIL (: On : Off) Shutter Current Position Iris Current Position Gain Current Position DETAIL FREQUENCY (H) DETAIL FREQUENCY (L)
Other enlargement inquiry commands (/)... Command Packet 8x 9 E E FF Destination Address Source Address V DETAIL CREATION - DETAIL CRISPENING (H) DETAIL CRISPENING (L) DETAIL H/V RATIO (H) DETAIL H/V RATIO (L) 8 9 DETAIL WHITE LIMITTER (H) DETAIL WHITE LIMITTER (L) DETAIL BLACK LIMITTER (H) DETAIL BLACK LIMITTER (L) KNEE APT LEVEL (H) KNEE APT LEVEL (L) COLOR DETAIL SATURATION (H) COLOR DETAIL SATURATION (L)
Other enlargement inquiry commands (/)... Command Packet 8x 9 E E FF Destination Address Source Address COLOR DETAIL PHASE (H) COLOR DETAIL PHASE (L) COLOR DETAIL WIDTH (H) COLOR DETAIL WIDTH (L) 8 9 AUTO KNEE (: ON : OFF) KNEE MODE (: ON : OFF) KNEE POINT (H) KNEE POINT (L) KNEE SLOPE (H) KNEE SLOPE (L) KNEE SATLEVEL (H) KNEE SATLEVEL (L) GAMMA LEVEL (H) GAMMA LEVEL (L)
Other enlargement inquiry commands (/)... Command Packet 8x 9 E E FF Destination Address Source Address BLACK LEVEL (H) BLACK LEVEL (L) BLACK GAMM LEVEL (H) BLACK GAMM LEVEL (L) 8 9
VISCA Command Setting Values IRIS Parameter p q F No. 9 F.9 (OPEN) 8 F. F. F. F.8 F. F. F. F F. F F.8 E F. D F. C F. B F.8 A F. 9 F8 8 F8. F9. F F F F F F CLOSE GAIN Parameter p q Gain (db) 9 8 9 8 F E D C B A 9 9 8 8 - SHUTTER Parameter p q Shutter Speed (sec) F /8 E / D / C / B / A / 9 / 8 / / / * * The setting is / when the video format is set to 8/9.9i or / 9.9p. The setting is / when the video format is set to 8/i or /p.
Pan/Tilt Position (for reference) Pan Angle (degrees) Left Right Yp Yq Yr Ys Yt Yp Yq Yr Ys Yt 98 FFC8 FED9 BA8 FE8 E FDB E8 FDE8 FC8B 88 FBF8 8 9C FB 9 F8 FAD8 C FAD 8 F9A98 EA F9 D8 F888 8 FEF 8A8 FB8 98 FC8 9 9BDE F Tilt Angle (degrees) Up Down Zp Zq Zr Zs Zp Zq Zr Zs 98 FC8 ED9 BA8 E8 E - E8 - - 88-8 9C - 9 F8 - Focus Ratio and Focus Distance (for reference) Focus Ratio Focus Distance.m.m.9m.8m.m.m 8.m 9.m A.m B.9m C.8m Zoom Position and Zoom Ratio (for reference) Zoom Position Zoom Ratio A8 8 BC F A 8 A 9 8 AA CC EC
Pan/Tilt Status Code List P Q R S Panning reaches the end of the left. Panning reaches the end of the right. Tilting reaches the upper limit. Tilting reaches the lower limit. Pan/tilt position cannot be detected. Pan functions normally. Pan mechanism is defective. Tilt functions normally. Tilt mechanism is defective. Pan/Tilt operating Pan/Tilt operations complete. Not initialized Initializing Initialization completes. Initialization failed. ( : optional)
Memory Function (Inquiry Commands) Preset No. last operated pp: Memory number last operated Comments While no Recall commands are used after the power has been tuned on F (or = for Reset, Set and Recall commands) 8 9 8 9 A B C D E F 8
Revision History Version Item Description. New edition 9