Flexible Counter Series in DIN size 24 x 48 mm



Similar documents
Preset Counter signo 721

Variable Preset Counter signo 723.1

Industrial Counting and Control Components

Multifunction devices

Panel Meters and Controllers Modular Panel Meter Type EDM 35

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

38 Series - Relay interface modules A

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

38 Series - Relay interface modules A

CONFIGURABLE SAFETY RELAYS

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Inductive Proximity Sensors

Quick Connect. quick - simple - efficient.

Short information Parameters are programmed via front-side membrane keypad

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Maximum Demand Control

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

SSI. Modbus Analogue Output DEVICENET ETHERNETIP. Zero Slip, Zero Wear. Exact Measurement. No Moving Parts. Permanently Calibrated.

NEW. EVEN MORE data acquisition and test stand automation

CARLO GAVAZZI MDM 40 TF

Siemens AG /42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

M-Bus-Logger Data Logger

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

Current and voltage measuring relays

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

HERZ-Thermal Actuators

Electronic Control Devices The European Product Catalogue 2007

3-phase, bidirectional energy meter

CONFIGURABLE SAFETY RELAYS

V350-R34 V350J-R34. npn inputs pnp inputs

RY2 miniature industrial relays

Series 7500 Torque Sensor

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Electronic Control Devices The European Product Catalogue 2007

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

GAE953 Electrical Alarm Unit 19" with Indicator

HYDRUS ULTRASONIC METER

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

Unattended Answering Device Instruction Manual

MasterINTERFACE 39 Series - Relay interface modules

Veeder-Root TM brand Eagle Signal TM brand Dynapar TM brand

Application/Connection Examples

Multifunction Digital Timer

Operating Temperature: 0 o to 70 o C mm (0.89 inches) ... Incremental Front View

AMTRON E-30 Compact heat and cooling meter

O C M III. Open Channel Flow Monitor

Series DFMT Digital Paddlewheel Flowmeter

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

DRO Function guide: Zero setting 1/2 calculation mm/inch conversion INC/ABS conversion

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

1 All safety instructions, warnings and operating instructions must be read first.

Description. Dimensions. Features. precision works better

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Smart DeviceNet Remote I/O Terminals

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

ABB i-bus EIB / KNX Weather Station WS/S 4.1

TUBE-TECH HLT 2A Stereo High- and Low shelving, T- filter & Low- and High cut

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

COM. port RS232C RS232C RS232C RS485. Thermocouple input. Part number. Not available. Not available. Available. Not available Available RS485.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

The multi-functional integrator Supercal 531

WinProladder software package

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

Technical Description. Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No ,

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black


DS1621 Digital Thermometer and Thermostat

Optimize your simple machines... Modicon M218 Selection Guide

M91 TM. Features: M91 HMI PLC. Communication

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

W150: Miniature photoelectric switch series with completely integrated electronics


USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

PNOZsigma - Base units

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

80 Series - Modular timers 16 A. Features

FLOOR INDICATORS CATALOGUE 2007

D.C. Motors. Products and specifications subject to change without notice.

E-STOP relays, safety gate monitors

6ES BE01-0AB0 6ES BE01-0AB0

A project to optimise quality and energy efficiency must include metering

Transcription:

Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery or maintenance-free and environmentally friendly with 12-24 V DC supply also high-voltage input 12-250 V AC/V DC up to 8 different functions for each standard model: 01 pulse counter 04 time counter (hhhhhh,hh) 05 numerical display for the PLC (serial) 07 counter with differential mode 08 maintenance counter (on request) OVERVIEW Standard Models Type 2 Type 4 Type 5 Hardware 8-digit LCD 8-digit LCD 6-digit LED Supply voltage 12 24 VDC 12 24 VDC 12 24 VDC Nominal data NV-FRAM NV-FRAM NV-FRAM retention > 10 years > 10 years > 10 years Clock PNP x x negative or positive DATA NPN edge programmable < 0.7 and < 0.7 and < 0.7 and > 5 V, max. 30 V DC > 5 V, max. 30 V DC > 5 V, max. 30 V DC Transmission rate 100 Hz 1 khz 1 khz Inputs Clock + Data Clock + Data Clock + Data Mounting depth 32 mm 60 mm 60 mm Software Impulse counter x x x Tachometer 1/min x x x Time counter h : 1/100 h x x x Time counter h : min : s x x x Numerical display for PLC x x x Position indicator x x bi directional Counter with differential mode x Maintenance counter 146 Components ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS

Technical data TYPE 2 LCD display DC supply voltage 12 24 V DC RESET: reset input with contact (negative, 30 Hz) short case Mmounting Input resistance < 50 kohm (static) Min. pulse length 17 ms (30 Hz), 70 µs (7.5 khz) 8-digit LCD, 7 mm Supply voltage U b 12... 24 V DC Current consumption DC 12... 24 V DC < 5 ma Inputs: lock programmable: 7.5 khz or 30 Hz (attenuated for contacts - manual reset via keyboard (can be locked) - external reset with static behaviour, active edge negative attenuated 30 Hz max. 7.5 khz, transmission rate for numerical display: 100 Hz 0 731 2 0 1 * S * Option: with plug-in screw terminals 05 numerical display for PC 72 Components 2000 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS

Technical data TYPE 4 LCD display 12-24 V DC supply voltage INPUT 2: control input for temporary locking of count input (gate) or second count input with position indicator RESET: reset input OUT: transistor output for preset signal long case Mounting Input resistance < 50 kohm (static) Min. pulse length 17 ms (30 Hz), 70 µs (7.5 khz) 8-digit LCD, 7 mm Supply voltage U b 12 24 V DC Current consumption DC 12 24 V DC < 50 ma Count input: Input 2: lock Transistor output signal Voltage/switching current programmable: 7.5 khz or 30 Hz (attenuated for contacts) with position indicator 2 khz: active edge positive manual reset via keyboard (can be locked) external reset with static behaviour, 30 Hz attenuated same edge as with count input gate or second count channel; same edge as with count input PNP output voltage supply minus 2 V; max. 10 ma max. 7.5 khz, transmission rate for numerical display: 1 khz 12-24 VDC 0 V Count Input 2 Tr. out 0 731 4 0 1 05 numerical display for PLC 74 Components 2000 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS

Technical data TYPE 5 LED display 12-24 V DC supply voltage INPUT 2: control input for temporary locking of count input (gate) or second count input with position indicator RESET: reset input OUT: transistor output for preset signal long case Mounting Input resistance < 50 kohm (static) Min. pulse length 17 ms (30 Hz), 70 µs (7,5 khz) 6-digit LCD, 7 mm Supply voltage U b 12 24 V DC Current consumption DC 12 24 V DC < 50 ma Count input: programmable: 7.5 khz or 30 Hz (attenuated for contacts) with position indicator 2 khz manual reset via keyboard (can be locked) external reset with static behaviour, same edge as count input Input 2: gate or second count channel lock Transistor output signal PNP output Voltage/switching current supply minus 2 V; max. 10 ma max. 7.5 khz, transmission rate for numerical display: 1 khz 12-24 VDC 0 V Count Input 2 Tr. out 0 731 5 0 1 0 731 5 0 7 05 numerical display for PLC 07 counter with differential mode (1 khz) Components 2000 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS 75

Special functions SPECIAL FUNCTIONS To best match your application, you can order special functions such as prescaler value, decimal point and preset value, which are permanently set by us before delivery. With the variable prescaler value you can adapt to already existing transfer ratios of your application. Small resolutions can be shown with the decimal point, e. g. for the position indicator or the tachometer. A special feature is the possibility of displaying an information text in the display, e. g. for the surveillance of maintenance cycles. In this case the desired information is shown in the display after reaching the fixed preset value. You can display any text that can be created with the 7-segment alphabet, e. g. STOP, HELP, FILTER etc. S SPECIAL VERSIONS Special functions Impulse Tacho- Time Numerical Position Differential for counter meter counter display indicator counter Preset value x x x x 0.001 bis 99,999 Decimal point x x x x 0 to 3 positions behind the comma Preset value x x 0 to 99 999 999 Information text x x (on reaching the preset value) LCD = 8 characters LED = 6 characters S SPECIAL VERSIONS Choose version and basic function: 0 731 7 * S * Option: with plug-in screw terminals only for standard model 1, 2 Standard version: 1 Standard model 1 2 Standard model 2 3 Standard model 3 4 Standard model 4 5 Standard model 5 Function: 1 Impulse counter 2 Tachometer (1/min) 1) 3 Time counter (hhhh:mm:ss) 4 Time counter (hhhhhh.hh) 6 Position indicator (2-channel) 2) 7 Counter with differential mode 3) 1) not available for standard type 3 2) not available for standard types 1, 2, 3 3) only available for standard type 5 Please state the desired special version on your order: P: (Value); D: (Value); V: (Value); T: (Text); Prescaler value: 0.001 to 99.999 4) Decimal point: 0 to 3 positions after the dot 4) Preset value: 0 to 99 999 999 5) The information text displayed on reaching the preset value can be built up as required from the 7-segment alphabet 4) not available for time counters 5) not available for tachometers and position indicator 76 Components 2000 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS