755 SERIES SMOKE ALARMS



Similar documents
DOMESTIC SMOKE ALARMS

Practice Note

SMOKE ALARMS CLASS 1A BUILDINGS

FIRE DETECTION AND ALARM SYSTEMS

What you need to know about. Smoke alarms for residential buildings

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:

Home Owners Guide to Smoke Alarm Safety

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Smoke Alarm Legislation Frequently Asked Questions

Smoke Alarms Save Lives!

USER S MANUAL. SMDC-16 Digital Control Communicator and SMPC-32 Personal Control

Smoke Alarm Legislation

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

P/N Rev D

User s Guide. Security Systems D220

Smoke Alarms. New smoke alarm requirements for existing buildings from 1 May Introduction. Advisory note March 2006

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

Smoke Alarm User s Guide

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

Smoke alarms. for the home PROTECT YOUR HOME FROM FIRE

St. John s University

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

Wireless Security System

User Guide for the DS7060 Control/Communicator

CERTIFICATE OF COMPLIANCE

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Wireless Security System

Fire Alarm system Installation Guide

Smoke & Carbon Monoxide

SECURITY SYSTEM NOTES. Security System Configuration

SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration

TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 2

Know Your Smoke Alarm

TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 1

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Guide to Massachusetts Smoke & Carbon Monoxide Requirements

Users Guide to Keypad Functions

INSTALLER INSTRUCTIONS

Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Pub. 559

READ ALL INSTRUCTIONS

Hotel Fire Safety for staff

Your Ademco. Fir&Burglar Alarm System. LogiCenter INTRODUCTION: 1. _- ALARM DEVICE MANUFACTURING CO.

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS

720r Addendum: Siting the 720r

Ionisation Smoke Alarm

SECURITY SYSTEM NOTES AREA LISTINGS SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

Help protect your home, possessions and family.

Wireless Security System

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. Kidde Fyrnetics 2000 SAVE THIS MANUAL FOR FUTURE REFERENCE

User s Guide. Security Systems

User s Guide. Security Systems

INSTRUCTION MANUAL PC255O

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

Berkeley Castle. Occupant Fire Safety

616, 626, 636 & 646 Keypads

F I R E IS THE LEADING CAUSE OF PREVENTABLE DEATHS IN THE HOME.

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Smoke & Carbon Monoxide

Rogers Smart Home Monitoring QUICK START GUIDE ROG_6093_QST_GDE_EN.indd 1 9/22/12 8:29 AM

Fire Facts Smoke Alarms

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. Kidde Fyrnetics 2003 SAVE THIS MANUAL FOR FUTURE REFERENCE

GC2 Panel User Guide

SMOKE ALARM MAINTENANCE PROGRAM

Solution Ultima ICP-CC488 Home security you can rely on

Are photoelectric smoke alarms better than ionization smoke alarms for adjacent to kitchen installations, to minimize nuisance alarms?

Wireless Security System

READ THIS FIRST CONT.

SECURITY SYSTEM NOTES

The Alberta Fire Code requires all homes in the province to have working smoke alarms.

Fire precautions in dwellings. Private sector housing Providing homes building communities

Make your home and family fire safe

Fire Safety Report Fire Statistics

SECURITY SYSTEM NOTES

Smoke Alarm User s Manual

Basic Information about your Smoke Alarm. Locating your Smoke Alarm

Fire make your home safe

MP 5.7 RESIDENTIAL SERVICES BUILDING STANDARD

1. Basic Information about your Smoke Alarm. 2. Locating your Smoke Alarm

Do the products you use comply?

This document was prepared for the Federal Emergency Management Agency s U.S. Fire Administration under contract number HSFE20-13-P-0275.

ALARM SYSTEM INSTALLATION GUIDE

Passive Infrared Motion Detector 5420/90. Installation Instructions

Visit Us on the Web! MODEL USI-1122L LONG LIFE* LITHIUM POWERCELL SMOKE & FIRE ALARM WITH SILENCE CONTROL

Alarm and Detection/Suppression

NetworX NX-6V2. LED Keypad User Manual

Union College Campus Safety Emergency Action Guide

BS5839 Part 1:2002 Overview

tattletale User Guide Consumer unit version P a g e

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

Solution Ultima ICP-CC488 Home security you can rely on

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

National Security Systems Inc (800) Security System User's Guide

Transcription:

755 SERIES SMOKE ALARMS

Smoke Alarms save lives Tragically, each year in Australia there are over 10,000 house fi res resulting in more than 70 deaths, 1,500 injuries and millions of dollars worth of property damage. These kinds of fi res happen all too frequently, and the fact is, they happen fast. A house can be literally razed to the ground in less than 15 minutes. That s why it s essential for every home to be fi tted with a suffi cient number of appropriate and suitably placed mains powered smoke alarms. Installing a high quality smoke alarm ensures your peace of mind by offering you 24 hour a day protection for your family and home against fi re and smoke. The early warning that a smoke alarm provides means less chance of major damage and, more importantly, less chance of lives being lost. A Clipsal Firetek 755 Series smoke alarm is a small investment yet potentially one of the most important you will ever make. The 755 Series comprises both ionisation and photoelectric models, in both surface mount and aesthetically appealing fl ush mount designs. Both models offer total protection in any residential or commercial installation. world s first unique fully recessed design... over 60% smaller More than 70 deaths each year 1,500 injuries each year Millions of dollars worth of property damage in Australia Unsurpassed style Todays modern housing demands electrical accessories that are not only of the highest quality, but look the part too. Designed to blend in with any décor, the stylish Clipsal Firetek 755 Series Flush Mount Smoke Alarm offers premium protection against fi re danger, but is an incredible 60% smaller than a regular smoke alarm. Photography by Oz Shots At last, style and safety have come together to offer you and your family unrivalled protection, with a sleek, unobtrusive smoke alarm design. The smaller diameter of the Flush Mount alarm allows it to fi t in visually with ceiling mounted downlights. Now that s innovative! 2 755 Series Smoke Alarms 755 Series Smoke Alarms 3

Flush Mount smoke alarm Who says smoke alarms can t be stylish? Clipsal Firetek s fl ush mount model offers you and your family maximum protection against smoke and fi re danger but is an amazing 60% smaller than a traditional smoke alarm. Featuring a sleek, modern design that blends into any décor, the fl ush mount smoke alarm offers you total protection without compromising on style. 40% thinner ultra reliable operation easy installation interconnectable up to 40 units super low profile, fully recessed design mains powered 220-240V a.c. 50Hz 35mA 9V d.c. battery backup (included) unit cannot be operated without 9V battery fitted 5 year limited warranty 60% smaller Approx. 140mm Test/Hush feature dust cover to prevent contamination during installation loud alarm indication: 85dB at 3 metres backup facility low battery indication (audible and visual) hush button to silence unwanted alarms complies with Australian Standard AS3786, Smoke Alarms Size of typical smoke alarm Instant alarm status 108mm A combined single Test/Hush button on the ionisation and photoelectric detectors allows the home owner or installer to test the operation of the smoke alarm by holding down the Test button and sounding the alarm. The same push-button can be used to silence the smoke alarm in the case of an unwanted or false alarm. Press and hold the Hush Button to quiet the alarm. Normal operation will automatically resume after about 10 minutes. Smoke alarms with an a.c. power source are constantly powered, but also incorporate a backup battery. This ensures that the alarm is always operational, even if the mains power is cut. Clipsal Firetek smoke alarms incorporate both audible and visual indicators to notify occupants of the alarm status. During normal operation, a green indicator signifi es power available, whilst a red indicator fl ashes about once per minute showing the battery check in progress. If smoke is detected the alarm will sound a loud 85 decibel audible siren. The red indicator fl ashes rapidly (about once per second) to indicate the alarm has been activated. If the smoke level continues to rise while the alarm is in Hush Mode the alarm will be re-activated, signifying that there may still be a fi re burning or other hazardous condition present. If the user presses the Hush Button, the audible alarm will be silenced, and the red indicator will fl ash periodically (about once every 10 seconds) to show the Hushed status. 4 755 Series Smoke Alarms 755 Series Smoke Alarms 5

Surface Mount smoke alarm Clipsal Firetek Surface Mount Smoke Alarms feature a stylish, state of the art design. The alarm is fully mains powered and features a 9V battery backup in case of power failure, so your family is always protected. Audible and visual indicators draw the occupant s attention to any alarm condition or to alert the home owner of a low battery status. The unit is interconnectable (up to 40 units), making it ideal for any domestic or commercial installation. When activated, the alarm sounds at a loud 85db to alert occupants. A large Test/Hush button can be used to regularly test the unit for normal function, or to silence the unit in the case of an unwanted alarm. Both photoelectric and ionisation smoke alarm models are available to ensure maximum protection from different types of fi res. For maximum protection, a combination of both types of smoke alarms should be used throughout your home or building. This ensures the earliest possible warning in the event of a fi re, increasing the chances of escape and survival. The Clipsal Firetek range offers a total trouble free system for selecting the correct smoke alarm, backed by a 5 year warranty. contemporary styling and smooth lines will blend in with any décor easy installation interconnectable up to 40 units dust cover to prevent contamination during installation hush button to silence unwanted alarms 5 year limited warranty 9V d.c. battery backup (included) unit cannot be operated without 9V battery fitted mains powered 220-240V a.c. 50Hz 35mA loud alarm indication: 85dB at 3 metres ultra reliable operation built in test facility to test unit function complies with Australian Standard AS3786, Smoke Alarms Test/Hush feature A combined single Test/Hush button on the ionisation and photoelectric detectors allows the home owner or installer to test the operation of the smoke alarm by holding down the Test button and sounding the alarm. The same push-button can be used to silence the smoke alarm in the case of an unwanted or false alarm. Press and hold the Hush Button to quiet the alarm. Normal operation will automatically resume after about 10 minutes. backup facility Smoke alarms with an a.c. power source are constantly powered, but also incorporate a backup battery. This ensures that the alarm is always operational, even if the mains power is cut. low battery indication (audible and visual) Instant visual status Clipsal Firetek Smoke Alarms incorporate both audible and visual indicators to notify occupants of the alarm status. During normal operation, a green indicator signifi es power available, whilst a red indicator fl ashes about once per minute showing the battery check in progress. If smoke is detected the alarm will sound a loud 85 decibel audible siren. The red indicator fl ashes rapidly (about once per second) to indicate the alarm has been activated. If the smoke level continues to rise while the alarm is in Hush Mode the alarm will be re-activated, signifying that there may still be a fi re burning or other hazardous condition present. If the user presses the Hush Button, the audible alarm will be silenced, and the red indicator will fl ash periodically (about once every 10 seconds) to show the Hushed status. 6 755 Series Smoke Alarms 755 Series Smoke Alarms 7

Quality by design All Clipsal FireTek Smoke Alarms are manufactured to the highest possible quality to comply with relevant Australian standards, and are SSL/ActiveFire listed to ensure full compliance with the Building Code of Australia. For added peace of mind, Clipsal FireTek also comes with a 5 year limited warranty. Clipsal Firetek smoke alarms are manufactured to exacting standards. Designed in Australia especially to suit the harsh Australian conditions, you can be sure that you will always be protected. Compliance & approvals All Clipsal FireTek smoke alarms are designed to ensure maximum protection in residential and commercial applications. Each model available carries the RCM mark, ensuring electrical safety and EMC compliance (emissions and immunity). All units comply with the latest Australian standards (AS3786 Smoke Alarms) and are ActivFire certifi ed to ensure compliance with the Building Code of Australia (BCA). Units are manufactured to the highest quality standard as endorsed by SAI Global as a Certifi ed Product. Independent auditing ensures manufacturing facilities are compliant with ISO 9001. Clipsal FireTek Smoke Alarms are fully backed by a fi ve year manufacturer s warranty as a further endorsement of product and reliability. Features & benefits Surface and fl ush mount models available. Available in photoelectric and ionisation detection technologies for optimum response times. Mains powered smoke alarm 220-240 a.c. 50Hz 35mA. 9V d.c. battery backup (included). Quick fi t-off/easy installation. Loud alarm indication: 85dB at 3 metres. Ability to interconnect up to 40 units. Low battery indication (audible and visual). False alarm control using Hush button (available on both models). Built-in test facility. Unit cannot be operated without 9V battery fi tted. Dust cover to prevent contamination during installation. Complies with Australian Standard AS3786, Smoke Alarms. SSL / ActivFire certifi ed. Quality endorsed Certifi ed Product, SAI Global. AS3786 Lic 21492 SAI Global 5 year limited warranty. 8 755 Series Smoke Alarms 755 Series Smoke Alarms 9

Photoelectric vs Ionisation When choosing a smoke alarm, it is important to know that different models use different methods to detect smoke. There are two main types of smoke detectors: ionisation, and photoelectric types. Each is specifi cally designed to detect different types of smoke, and give the earliest possible warning in the event of a fi re. The amount of warning given depends on the type of combustible material that is burning, and the type of alarm selected for your home. The more warning you get, the more time you have to escape the deadly toxic smoke and fl ames. Ionisation type alarms respond faster to small smoke particles, such as those given off by burning paper, straw, or wood. Photoelectric alarms respond faster to larger smoke particles, such as those produced by burning foam, rubber, plastics and other synthetic materials. Nowadays, most homes are fi lled with synthetic materials. These include nylon found in carpets and curtains, plastic consumer goods and the foam rubber found in a lounge chair or mattress of your bed. Therefore the best detector type for your home is usually a photoelectric detector type. For the ultimate protection, a combination of both ionisation and photoelectric is recommended. Typical applications MODEL TYPE TYPICAL APPLICATIONS 755PSMA Photoelectric Lounge 755PFM Living areas Bedrooms Rumpus 755SMA Ionisation Hallway 755FM Corridor Study/ Home office Photoelectric alarms are recommended in most situations why insist on mains powered? Where battery powered alarms are present, up to 40% of them are non-functional due to poor maintenance or flat batteries. Australian Bureau of Statistics vs Mains Powered Smoke alarms can either be mains powered, or battery powered. powered smoke alarms are commonly available from supermarkets and hardware stores. These types of alarms DO NOT comply with the required regulations for new buildings, as they offer an inferior level of protection. alarms have a big weakness they rely on YOU to test and change the battery on a regular basis. All too often we get lazy or forget to do this, and the results can be catastrophic. In the event the battery goes fl at, the alarm cannot detect smoke, and will not alert you to any danger. All mains powered smoke alarms have a continuous source of power and also incorporate a backup battery. That way the alarm can respond to the presence of smoke, even if the mains power is cut. Mains powered smoke alarms also offer features that are not available in battery powered models, including the ability to be interconnected. Mains powered smoke alarms can also be interconnected so that when one alarm trips, all units will sound ensuring adequate warning and the best possible reaction time. All Clipsal smoke alarms are supplied with a high quality Energizer alkaline battery to ensure long life and superior performance. 10 755 Series Smoke Alarms 755 Series Smoke Alarms 11

How many smoke alarms do I need? If you sleep with your bedroom doors closed: If you have a stairway leading to another storey: The Building Code of Australia mandates the installation of at least one smoke alarm in every new home but is one enough? Let s say the alarm is installed in the main living area of your home and a fi re breaks out. If you are asleep in another area of the home, perhaps with the bedroom door closed, you may not hear the alarm until it is too late By the time you respond, the house is engulfed in fl ames, and deadly toxic smoke may block your exit path to safety As a general rule of thumb, alarms need to be installed within 10 paces of a fi re to detect the smoke and still give you adequate time to escape. That is why it is so important to have at least two alarms installed in your home. The best protection is an alarm in every room excluding the kitchen, laundry and bathrooms. All alarms should be interconnected, so that if smoke is detected by one alarm all units will respond and warn you, no matter where you are in the house. Where should they be installed? Smoke alarm installation locations should be carefully selected in order to maximise their effectiveness and response time. It is also important to avoid certain areas so as to minimise the chance of false alarms or nuisance tripping. Follow these important guidelines. Never install a smoke alarm in the kitchen area. Never in a steamy area (eg, bathroom, laundry). Never in a garage or carport. Never in an outside location. It is recommended additional alarms be installed in the bedrooms, interconnected with those located in passageways and other parts of the dwelling, to ensure that you are alerted by the activation of any alarm. If there is no passageway: If bedrooms are accessed directly from the living area, install the alarm outside each bedroom 900mm from the doorway. For additional protection, have interconnected alarms in the bedrooms as close as practicable to the centre of each room. If there are bedrooms at both ends of the house: Install interconnected alarms in the passageway to each of these areas. In passageways, the installation point should be at the end closest to the living area and certainly before the fi rst bedroom is reached so that when the alarm sounds, there will be suffi cient time to allow evacuation by normal exit routes. Install a smoke alarm on the ceiling above the head of the stairs. If the stairway is enclosed, install the alarm on the ceiling within the enclosure near the exit to the upper storey, and interconnect it with alarms in the upstairs room or passageway. Avoid dead air space: Smoke will not fl ow into dead air spaces. Avoid the marked regions to ensure optimum response from the alarm. Dead air space Suitable smoke alarm location Ceiling line Exposed beams 300mm min. 500mm max. Did you know? When you are asleep you lose your sense of smell. In the event of a fi re, the smell of smoke will not wake you. Your life depends on your ability to be able to hear the audible alarm. That s yet another important reason why you should have more than one smoke alarm installed in your home, and why they should always be interconnected. Why is it important that my alarms be interconnected? Where multiple smoke alarms are installed, they can be linked together or interconnected as desired. This ensures that if one alarm detects smoke, then all interconnected alarms will activate to sound the warning simultaneously in all locations in the house. This is especially important in larger, or multi-storey homes, where the alarm that detects the smoke from a fi re (i.e. the alarm closest to the fi re) may simply be too far away for occupants to hear. By the time you hear the alarm the fi re may be out of control, and your route to safety may be cut off. Clipsal Firetek Smoke Alarms allow up to forty alarms to be linked, ensuring that you will have the earliest possible warning of a fi re danger no matter where you are in the house, and leaving you more time to exit safely. Always avoid dead air spaces. The correct selection and placement of your smoke alarms is a critical issue. Thankfully, most electricians have been fully trained in all aspects of fi re protection, and will be able to give you professional advice as a part of your installation. Absolute Minimum Requirement. Photoelectric recommended. BEDROOM LIVING FAMILY always install more than one smoke alarm Photoelectric Smoke Alarm, for extra protection. Ionisation Smoke Alarm, for extra protection. STUDY DINING BEDROOM BEDROOM 12 755 Series Smoke Alarms 755 Series Smoke Alarms 13

What to do if the alarm sounds If Smoke Alarm Sounds 1. Leave immediately, following your family s escape plan. YES Feel the door. Is it hot? NO Sample: 2. As you leave, don t open any inside doors without fi rst feeling the surface. If a door is hot, or you see smoke coming through the cracks, do not open the door. Use an alternative exit. 3. If the inside of the door is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in. 4. If the air is smoky, stay as close to the fl oor as possible. 5. Breathe shallowly through a cloth, which if possible, should be wet. 6. Once outside, go to your pre-selected assembly area and make sure everyone else is there. 7. Call the Fire Department from a neighbour s home never from your own. 8. Do not return to your home until fi re offi cials give you permission to do so. Go to the window. Can you open it? YES Climb out of the window. NO YES Break the window with a chair or stool, place a rug or blankets over the window sill, climb out beware of broken glass. Move around the outside of the house and knock on all the windows to wake anyone inside. Look at the bottom of the door is smoke coming from under the door? NO Open door cautiously STAY LOW! Closing all doors and, alerting other occupants as you go, leave the house. Developing an escape plan Have an escape plan. In the event a fi re does break out in your home, every member of the family should be prepared and know exactly what to do. Practise crawling low under smoke, checking doors before opening, and make sure everyone knows at least two ways out of the home. Decide on a place to meet after escaping. Consult your fully trained local electrician for professional advice about all aspects of selection, location and installation of smoke alarm products. Draw your escape plan here Go to your arranged meeting place and stay there until everyone arrives. More information about fi re safety is also available from your local metropolitan or country fi re service. Here are some suggestions for developing your escape plan: NO DO NOT RE-ENTER THE HOUSE. Go to their window and try to get the person out through the window. Is everyone out? Family? Visitors? YES One person goes to phone the Fire Service. The others MUST STAY TOGETHER. Don t Panic! Clipsal would like to acknowledge the South Australian Metropolitan Fire Service for the use of their fi re escape plan fl owchart. Photography by Oz shots. 1. Make a fl oor plan which clearly indicates all doors and windows in your home and at least two escape routes from each room. Multi-storey dwellings require special attention. For instance, upper storey windows may need a chain ladder or other fi re stairway as a means of exit. 2. Determine a place outside your home (e.g. the letter box or front fence) where all family members can assemble if a fi re occurs. 3. Discuss your escape plan with all members of your family. Show everyone, particularly young children, what to do in case of a fi re. 4. Make sure all family members are familiar with the sound of the detector. 5. Sound the alarm at least every six months and practise your family s fi re drill. 14 755 Series Smoke Alarms 755 Series Smoke Alarms 15

Quick tips IS IT TIME FOR A NEW BATTERY? Good quality smoke alarms typically operate from the mains voltage supply, but they also contain a backup battery which allows the alarm to remain operational even when the power is cut during a blackout. SICK OF UNWANTED FALSE ALARMS? To ensure the best protection for you and your family, follow these simple handy hints: Choose high quality alarms from a reputable supplier (Clipsal FireTek recommended). Install multiple alarms, which are interconnected for the best protection. Have your alarms installed by a professional installer. Choose the correct alarm type for the location. Test the smoke alarm operation regularly (minimum once per month). TEST BATTERY Clean the unit regularly (minimum maintenance once per month). Check battery condition regularly (minimum once per month). ACTION HOW OFTEN? COMMENTS Test Once per month Like all battery operated appliances, your smoke alarm battery must be checked regularly to make sure that it will still function if there is a fi re. Replace Replace Smoke Alarm Unit Once per year After 10 years of normal service To test the battery, press and hold the Test Button. This should be done with the mains power switched off (turn off the lighting circuit at the switchboard). The alarm should sound indicating the battery condition is acceptable. If the unit fails to respond, the battery should be replaced without delay. From time to time the smoke alarm battery must be replaced with a new one. Clipsal recommend choosing a common date that occurs every year and is easy to remember (such as your birthday, or at the end of daylight saving time). The battery should also be replaced if the alarm fails to sound when you press and hold the Test button. All smoke alarms (regardless of manufacturer) have a limited service life, normally ten years. After that period, correct operation of the alarm cannot be guaranteed. The entire smoke alarm unit should be replaced with a new one. Clipsal Lifesaver Another Lifesaver initiative from Clipsal Australia Patent Pending Australian Electrical Authority Certifi cate of Suitability for the surface mount smoke alarm CS/1245/S Australian Electrical Authority Certifi cate of Suitability for the fl ush mount smoke alarm CS/1253/S AS3786 Lic 21492 SAI Global Thanks to the South Australian Metropolitan Fire Service and Oz Shots for fi re photography. Clipsal Australia Pty Ltd A member of Schneider Electric Head Office 33-37 Port Wakefi eld Road, Gepps Cross, South Australia 5094 Website clipsal.com Contact us clipsal.com/feedback National Customer Care Enquiries: 1300 2025 25 National Customer Care Facsimile: 1300 2025 56 printed on recycled paper International Enquiries International Sales and Marketing Email export@clipsal.com.au Schneider Electric (NZ) Ltd 38 Business Parade South, Highbrook, East Tamaki, Manukau 2013, NEW ZEALAND Telephone + 64 9 829 0490 Facsimile + 64 9 829 0491 Website www.schneider-electric.co.nz Clipsal Customer Care Freephone 0800 652 999 Freefax 0800 101 152 Email sales@nz.schneider-electric.com Website www.clipsal.co.nz You can fi nd this brochure and many others online in PDF format at: clipsal.com Follow the links off the home page or access the following page directly: clipsal.com/brochures Clipsal Australia Pty Ltd reserves the right to change specifi cations, modify designs and dis con tin ue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifi cations and other in for ma tion in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. Clipsal Australia Pty Ltd C3-011 CLIPCOM 19771 November 2009 The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. O/N 19771 November 09