Panel Meters and Controllers Modular Panel Meter Type EDM 35



Similar documents
Energy Management Energy Meter Type EM23 DIN

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Power Meter Series 700

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Digital Pressure Measuring Instrument MDR480

Quick Connect. quick - simple - efficient.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

38 Series - Relay interface modules A

38 Series - Relay interface modules A

48 SERIES Relay interface modules 10 A

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Energy Management Power Analyzer Type WM14-96 Basic Version

Flexible Counter Series in DIN size 24 x 48 mm

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Multifunction devices

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Applications. diris_826_a_1_gb_cat

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

RY2 miniature industrial relays

Three-phase monitoring relay CM-PFE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

49 Series - Relay interface modules A. Features

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Installation manual. Generator Paralleling Controller GPC multi-line C

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

DCS Series 1 kw, 1.2 kw, & 3 kw

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Maximum Demand Control

Safety technique. Emergency stop module BO 5988 safemaster

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

CARLO GAVAZZI MDM 40 TF

Electronic Control Devices The European Product Catalogue 2007

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Telephone- and leased line modem for industrial applications TD-36

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Duct Humidity Transmitter

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

E-STOP relays, safety gate monitors

Thermistor motor protection

Current and voltage measuring relays

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Relés e Contatores de Estado Sólido SIRIUS

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Power Meter Series 800

DS 600. A contact free flux gate based current measurement sensor 600A rms

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

Fluke 3000 FC Series Test Tools Technical Data

Power Supplies 3. SDN-P DIN Rail Series

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Trip circuit supervision relay. Type RXTCS

Control Devices Catalogue. Control Devices. Preferred and Standard Products

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER

80 Series - Modular timers 16 A. Features

Voltage Regulator SPAU 341 C. Product Guide

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electronic Control Devices The European Product Catalogue 2007

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Variable Preset Counter signo 723.1

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Transcription:

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming Programmable hysteresis and time delay (up to 2 setpoints) Data hold Peak/valley function Password protection of programming parameters Stock-saving - several ranges on each input module IP 65 (front) Optional hardware lock of programming Optional high-efficiency red or green display Product Description Type Selection Range DC Voltmeters: V1D: -199.9 to +199.9 mv V2D: -1.999 to +1.999 V V3D: -19.99 to +19.99 V V4D: -199.9 to +199.9 V V5D: -600 to +600 V * The EDM 35 is a 3 1/2-digit, modular digital panel meter where input and output modules can be combined to suit many applications. Scaling and setpoints are fully programmable and the programming itself is very user-friendly. Furthermore, the EDM 35 includes peak/valley function and password protection. The housing is easy to mount and ensures a protection degree of IP 65. Range AC Voltmeters: V1A: 0 to 199.9 mv V2A: 0 to 1.999 V V3A: 0 to 19.99 V V4A: 0 to 199.9 V V5A: 0 to 600 V * * Nominal voltage according to EN 60664-1. The measuring range includes 15% tolerance equal to 690 V. Ordering Key Model Range code Relay output Signal output Options Range Ohmmeters: R1D: 0 to 199.9 Ω R2D: 0 to 1.999 kω R3D: 0 to 19.99 kω R4D: 0 to 199.9 kω EDM35V1D41XXXY Range DC Ammeters: A1D: -199.9 to +199.9 µa A2D: -1.999 to +1.999 ma A3D: -19.99 to +19.99 ma A4D: -199.9 to +199.9 ma A5D: -1999 to +1999 ma A6D: -5.00 to +5.00 A A7D: -10.00 to +10.00 A Range AC Ammeters: A1A: 0 to 199.9 µa A2A: 0 to 1.999 ma A3A: 0 to 19.99 ma A4A: 0 to 199.9 ma A5A: 0 to 1999 ma A6A: 0 to 5.00 A A7A: 0 to 10.00 A Range Thermometers: Pt 100: P1C: -100.0 to 199.9 C P2C: -100 to 850 C P1F: -148.0 to 199.9 F P2F: -148 to 392 F P3F: -148 to 1562 F Thermocouple Type J: -JC: -100 to 760 C -JF: -148 to 1400 F Signal Output: X: None 1: 4 to 20 ma 2: 0 to 20 ma 4: 0 to 10 V 5: 12VDC excitation output 6: 24VDC excitation output Options: XXY: None CXY: High eff. red display DXY: Green display XPY: Program lock 01Y-99Y: Special options (assigned by factory) Thermocouple Type K: -KC: -100 to 1250 C -KF: -148 to 1999 F Relay Output: 0: None 1: 1 Relay 2: 2 Relays Power Supply: 3: 12 to 48 VDC 4: 230 VAC 5: 115 VAC 6: 48 VAC 7: 24 VAC Range Frequency Meters: F1X*: 5.0 to199.9 Hz F2X*: 10.0 to 1999 Hz * Replace X with: A for input B for NPN, PNP & Contact input C 600 VAC input Specifications are subject to change without notice 1

Type Selection (cont.) Range Tachometers: T1X*: 8.0 to 199.9 rpm @30 ppr** T2X*: 5.0 to 199.9 rpm @60 ppr** T3X*: 2.0 to 199.9 rpm @100 ppr** T4X*: 20 to 1999 rpm @30 ppr** T5X*: 10 to 1999 rpm @60 ppr** T6X*: 10 to 1999 rpm @100 ppr** * Replace X with: A for input B for NPN, PNP & Contact input ** pulses per revolution Input Specifications - General Input modules supplied by main unit EMC Electromagnetic compatibility Immunity Acc. to IEC 60801-4 Acc. to IEC 60801-5 Supply Specifications AC Overvoltage cat. III (IEC 60664) Rated operational voltage 230 VAC ± 10% 115 VAC ± 10% 48 VAC ± 10% 24 VAC ± 10% Frequency 50/60 Hz ± 5Hz Voltage interruption 20 ms Rated insulation voltage 250 VAC basic rms Rated impulse withstand voltage 6 kv (1.2/50 µs) IEC 60664-1 DC Rated operational voltage 12 to 48 VDC ±15% Voltage interruption 10 ms (voltage = 10 VDC) Rated insulation voltage 150 VDC basic Rated impulse withstand voltage 4.0 kv (1.2/50 µs) IEC 60664-1 Rated operational power < 7 VA EMC Electromagnetic compatibility Immunity Acc. to IEC 60801-4 Acc. to IEC 60801-5 Separate Ordering Numbers Main unit Ordering number (mechanical parts included) Red display (standard red) 5100711 Red display (high-bright red) 5100712 Green display 5100710 With Program Input modules Lock VDC 5100530 5100630 VAC 5100531 5100631 ADC 5100532 5100632 AAC 5100533 5100633 AAC/ADC 10 A 5100534 5100634 Ohm 5100535 5100635 Pt 100 5100536 5100636 Pt 100 850 C 5100539 5100639 Thermocouple Type J 5100537 5100637 Thermocouple Type K 5100538 5100638 Tachometer 5100540 5100640 Frequency meter 5100541 5100641 Output modules 1 Relay 5100561 2 Relays 5100562 Analog output 5100560 12/24 VDC excitation output 5100526 modules 12 to 48 VDC 5100524 24 VAC 5100523 48 VAC 5100522 115 VAC 5100521 230 VAC 5100520 General Specifications Display 7-segment LED, height 14.2 mm 2 LEDs for indication of relay ON Min./Max. indication -1999/1999 Overrange indication EE (underrange: -EE) See module specifications See module specifications Scaling Electrical input range Progr. within whole range Display range Progr. within whole range Decimal point position Programmable Module connection Screw terminals Environment Degree of protection IP 65 (front) IP 20 (behind panel) Operating temperature 0 to +50 C. R.H. < 90% non-condensing Storage temperature -10 to +60 C. R.H. < 90% non-condensing Weight Housing Dimensions Housing material Front material Colour Approvals Approx. 350 g depends on modules used 48 x 96 x 89 mm ABS/Polycarbonate blend Polycarbonate Black housing Red front with red display Grey front with green display CE, CSA, UL 2 Specifications are subject to change without notice

Input Specifications - Modules Voltmeters - AC/DC (5100531/5100530, 5100631/5100630) Measuring Jumper Range code Resolution Input ranges position imped. AC DC 199.9 mv 1-4 7 1 0.1 mv 100 kω 1.999 V 2-5 8 2 1 mv 100 kω 19.99 V 2-5 9 3 10 mv 1 MΩ 199.9 V 3-6 10 4 0.1 V 1 MΩ 600 V * 5-6 12 6 1 V 1 MΩ * Nominal voltage according to IEC 664-1. The measuring range includes 15% tolerance equal to 690 V. AC voltmeter DC voltmeter AC voltmeter DC voltmeter 0.3% rdg ±3 dgt 0.2% rdg ±2 dgt ±150 ppm/ C ±0.2 dgt/ C ±100 ppm/ C ±0.05 dgt/ C Ammeters - AC/DC(5100533/5100532/ 5100534, 5100633/5100632/5100634) Measuring Jumper Range Resolution AC DC 199.9 µa 1-2 7 1 0.1 µa 1.999 ma 2-3 8 2 1 µa 19.99 ma 4-5 9 3 10 µa 199.9 ma 5-6 10 4 0.1 ma 1999 ma 2-5 11 5 1 ma 5.00 A 2-5 12 6 10 ma 10 AAC 2-3 12-10 ma 10 ADC 1-2 - 6 10 ma AC ammeter 0.3% rdg ±3 dgt AC ammeter (10 A) 0.5% rdg ±5 dgt DC ammeter 0.2 % rdg ±2 dgt DC ammeter (10 A) 0.5% rdg ±5 dgt AC ammeter ±150 ppm/ C ±0.5 dgt/ C AC ammeter (2 A, 5 A) ±200 ppm/ C ±0.1 dgt/ C AC ammeter (10 A) ±200 ppm/ C ±0.5 dgt/ C DC ammeter ±100 ppm/ C ±0.05 dgt/ C DC ammeter (2 A, 5 A) ±200 ppm/ C ±0.5 dgt/ C DC ammeter (10 A) ±200 ppm/ C ±0.5 dgt/ C Voltage drop < 200 mv (all ranges) Thermometers (5100536/5100537/5100538, 5100539/5100636/5100637/5100638/5100639) Range Reso- Temperature lution drift Pt 100: -100.0 to 199.9 C 0.1 C ± 0.2% rdg ±150 ppm/ C ± 2 dgt ± 0.05 dgt/ C -148.0 to 199.9 F 0.2 F ± 0.2% rdg ±180 ppm/ F ± 4 dgt ± 0.10 dgt/ F -148 to 392 F 1 F ± 0.2% rdg ±180 ppm/ F ± 4 dgt ± 0.10 dgt/ F Pt100, 850 C: -100 to 850 C 1 C ± 0.2% rdg ±150 ppm/ C ± 3 dgt ± 0.05 dgt/ C -148 to 1562 F 2 F ± 0.4% rdg ±180 ppm/ F ± 6 dgt ± 0.1 dgt/ F Thermocouple type J: -100 to 760 C 1 C ± 0.1% rdg ±100 ppm/ C ± 4 dgt ± 0.05 dgt/ C -148 to 1400 F 1 F ± 0.1% rdg ±180 ppm/ F ± 8 dgt ± 0.1 dgt/ F Thermocouple type K: -100 to 1250 C 1 C ± 3% rdg ±100 ppm/ C ± 3 dgt ± 0.05 dgt/ C -100 to -50 C 1 C ± 1% rdg ±100 ppm/ C + 5/-1 dgt ± 0.05 dgt/ C -50 to 780 C 1 C ± 0.1% rdg ±100 ppm/ C ± 3 dgt ± 0.05 dgt/ C 780 to 1250 C 1 C ± 0.25% rdg ±100 ppm/ C + 1/-3 dgt ± 0.05 dgt/ C -148 to 1999 F 2 F ± 3% rdg ±180 ppm/ F ± 6 dgt ± 0.1 dgt/ F -148 to -58 F 2 F ± 1% rdg ±180 ppm/ F + 10/- 2 dgt ± 0.1 dgt/ F -58 to 1436 F 2 F ± 0.1% rdg ±180 ppm/ F ± 6 dgt ± 0.1 dgt/ F 1436 to 1999 F 2 F ± 0.25% rdg ±180 ppm/ F +2/-6 dgt ± 0.1 dgt/ F Ohmmeters (5100535, 5100635) Measuring Jumper Range- Resolution 199.9 Ω 1-4 7 0.1 Ω 1.999 kω 2-5 8 1 Ω 19.99 kω 3-6 9 0.01 kω 199.9 kω 1-2 10 0.1 kω 0.2% rdg ±2 dgt ±150 ppm/ C ±0.1 dgt/ C Specifications are subject to change without notice 3

Input Specifications - Modules (cont.) Tachometers (5100540, 5100640) Measuring Jumper Range Resolution 199.9 rpm @30 ppr* J4, 1-2 7 0.1 RPM 199.9 rpm @60 ppr* J5, 1-2 8 0.1 RPM 199.9 rpm @100 ppr* J6. 1-2 9 0.1 RPM 1999 rpm @30 ppr* J4, 2-3 10 1 RPM 1999 rpm @60 ppr* J5, 2-3 11 1 RPM 1999 rpm @100 ppr* J6, 2-3 12 1 RPM * pulses per revolution Input selection NPN, PNP, Contact Input impedance NPN, PNP and Contact Time constant (tc) J1 J2 1% rdg ±5 dgt ± 200 ppm/ C 1 kω 5 kω 1 sec. Frequency Meters (5100541, 5100641) Measuring Jumper Range Resolution 199.9 Hz J7 7 0.1 Hz 1999 Hz J8 8 1 Hz Input selection J1, J4 and J6 NPN, PNP, Contact J2 and J5 600 VAC J3 1% rdg ±5 dgt ± 200 ppm/ C Input impedance 1 kω NPN, PNP and Contact 5 kω 600 VAC 600 kω Time constant (tc) 1 sec. Output Specifications Excitation output (5100526) Supplied by main unit Output voltage 12 VDC: jumper position 3-6, tolerance ±20% 24 VDC: jumper position 1-4, tolerance ±20% Output current 12 VDC 35 ma DC 24 VDC 20 ma DC EMC Electromagnetic compatibility Immunity Acc. to IEC 60801-4 Acc. to IEC 60801-5 Analogue output (5100560) Measuring ranges Load resistance Relay output 1 or 2 relays (5100561/5100562) Supplied by main unit Output 1 or 2 SPDT relays Rated insulation voltage 250 V basic rms Contact ratings (AgCdO) Resistive AC 1 5 A, 250 VAC DC 1 5 A, 24 VDC Small inductive loads AC 15 2 A, 250 VAC DC 13 3 A, 24 VDC Mechanical life 40 x 10 6 operations Electrical life 10 5 operations (at max. load) Operating frequency max. 10 Hz (50% duty cycle) Dielectric strength Dielectric voltage 2 kvac (rms) Rated impulse withstand volt. 4 kv (1.2/50 µs) 0 to 20 ma 500 Ω 4 to 20 ma 500 Ω 0 to 10 V 1,000 Ω 0 to 20 ma ±1% rdg ±0.1 ma 4 to 20 ma ±1% rdg ±0.1 ma 0 to 10 V ±1% rdg ±0.05 V ±200 ppm/ C Short-circuit protection yes 4 Specifications are subject to change without notice

Wiring Diagrams Power supply 5100520-23 5100524 5100526 5100560 5100561 5100562 5100530 5100531 5100532 5100533 5100534 5100535 5100536 5100537 5100538 5100540 5100541 Modules with type nos. xxxx63x are equipped with Program Lock function. Module position (slot) in the base unit is indicated by a drawing on the plastic cover. Caution! Since the input circuitry is not galvanically isolated, the potential of the measured variable will be present on all connections to the unit (i.e. "Hold" input). This is of special importance when measuring line voltage and current. Note. By short-circuiting terminals marked "HOLD" (supply module), it is possible to hold the displayed value indefinitely (hold function). The comparison of the input variable with the alarm setpoint remains active. To reactivate the display, remove the short-circuit. Specifications are subject to change without notice 5

Front Panel Description 2 2. Display 3 1/2-digit (maximum read-out 1999). 3 Alphanumeric indication by means of 7-segment display for: - Displaying of the measured value. - Indication of programming parameters. 3. LED - 1 and 2 LED indicators for alarm conditions. 1. Keyboard «S» Set/enter Up Down 1 Set-up and programming procedures are easily controlled by the three pushbuttons. Set/Enter key: - Entry of variables. - Selecting programming functions. 4 4. Engineering unit Screen for interchangeable unit label.the symbols in the greyish areas are those available on the set of engineering unit labels supplied with the EDM. (Engineering unit label to be inserted by customer.) W = 08 MΩ = 16 % = 24 mm HG = 32 cm = 40 mv = 01 kw = 09 Hz = 17 mbar = 25 l/min = 33 m = 41 V = 02 MW = 10 khz = 18 bar = 26 l/h = 34 kg = 42 kv = 03 var = 11 RPM = 19 psi = 27 kg/min = 35 ppm = 43 µa = 04 kvar = 12 m/s = 20 ata = 28 ton/h = 36 ka = 44 ma = 05 Mvar = 13 m/min = 21 ate = 29 m 2 /min = 37 cos φ = 45 A = 06 Ω = 14 C = 22 kg/cm 2 = 30 m 2 /h = 38 m 3 = 46 mw = 07 kω = 15 F = 23 mm H 2 O = 31 mm = 39 µs = 47 Up and Down key for: - Display control. - Increasing or decreasing programming value. - Selecting programming functions and instrument configuration together with the «S» key. Operation Diagrams Setpoint Operation Scaling Operation 6 Specifications are subject to change without notice

Mode of Operation Modules and Slot Position Depending upon the input modules used, it is possible to measure AC/DC (current or voltage), resistance (the range is selected with a jumper on the input module) or temperature (Pt 100 or Thermocouple J/K). Without an output module, the EDM is an indicator - by inserting an output module the EDM is a controller. Settings Programmable setting: Jumper setting: The input range and the display range are fully programmable, and so are the setpoint(s) if a relay output module is inserted. A hold function is available for freezing a measured value. Passwords 0 to 99 are for overall programming while passwords 100 to 199 allow direct set-point programming outside the password protection. See user manual for further details. See user manual. See user manual. Rear view of main unit Slot Slot Slot Slot Slot #1 #2 #3 #4 #5 Input Module: VAC VDC AAC ADC 10A AC/DC Ω Pt 100 Thermo couple Tachometer Frequency Output Module: Excitation output Analogue output Power Supply module: 24 VAC 48 VAC 115 VAC 230 VAC 12-48 VDC Output Module: 1 Relay output 2 Relay outputs Overall Dimensions and Panel Cutout (mm) Front view Side view Top view Panel cutout Panel All dimensions in mm. Specifications are subject to change without notice 7