Dehumidification Frequently Asked Questions



Similar documents
Glossary of Heating, Ventilation and Air Conditioning Terms

air conditioners how to choose a cooling system

Whole House Dehumidification for Occupant Comfort and Energy Savings

Answers to Your Questions from the Webinar

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Energy Efficiency. Energy Efficient Home Cooling:

Residential Ventilation

Air-Conditioning Buying Guide

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Operation and Installation Manual. Max Series

Lesson 36 Selection Of Air Conditioning Systems

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only

Quest 105, Dry155, and 205 Dual

Lower Energy Costs with Rooftop Air-Conditioning Package Units

Get the FACTS about SEER and Deliver Better Customer Value

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

SECTION HEAT PUMPS

Chilled Water HVAC Systems

Bring the fresh in. Dedicated Outside Air Systems

Standard Heating and Air, Inc Committed to Excellence

READ ONLY INNOVATIVE SYSTEMS FOR PERFECTLY CONDITIONED AIR TRANE AIR HANDLERS TRANE AIR HANDLERS. Consistent comfort throughout your home

How To Buy A Lennox Power System

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Trane XB Series. A reputation for reliability and smart, sensible comfort.

SWIMMING POOL HEAT PUMP

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

Local Dealer:

Defining Quality. Building Comfort. Precision. Air Conditioning

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

DX14SA AIR CONDITIONER ENERGY-EFFICIENT UP TO 15 SEER SINGLE SPEED COMFORT FOR LIFE

Refrigeration Basics 101. By: Eric Nelson

Energy Efficiency in Industrial HVAC Systems

Why Daikin? 2015 Houston, Texas USA

Element D Services Heating, Ventilating, and Air Conditioning

Series. Air Conditioners. Two-Stage, Extra-Efficient Air Conditioners with up to 21.0 SEER. Infinity

3/29/2012 INTRODUCTION HVAC BASICS

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

Moisture Control. It s The Dew Point. Stupid! Its not the humidity.

Measuring The Right Thing For Humidity Control It s the Dew Point Stupid!

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

Trane XR Air Conditioners. Comfortable, cool and smart.

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Pool Dehumidification Basics

HSX19 Air Conditioner Up to SEER. Home Comfort Systems HSX19. The most quiet and efficient central air conditioner you can buy.

catalog Single Package Vertical Air Conditioners and Heat Pumps

Innovent LASER Packaged Fresh Air Conditioning Units

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

By Tom Brooke PE, CEM

Smaller. Quieter. Smarter.

HVAC Basic Science - System Capacity

CoastGuard Two-Stage Air Conditioner with Puron Refrigerant

How Ground/Water Source Heat Pumps Work

Allegiance Air Conditioners

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Why is my air conditioner dripping on my customers?

SMALL DUCT HIGH VELOCITY COMFORT SYSTEM

Automobile Air Conditioning Primer

Heating and Cooling Basics Thermostat Control

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.

Commercial Portable Air Conditioners

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

How To Understand Evaporator

USER S MANUAL HSC-24A

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

Air Conditioners. A cool, comfortable solution to take you to a higher standard of comfort. READ ONLY

Poor Performing AC? High Electric Bills? High Humidity?

Two-Stage Air Conditioner with Puron Refrigerant

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Characteristics of Evaporators

Two-Stage Air Conditioner with Puron Refrigerant MODEL 180B

Cooling Capacity CFM in. w.c. (125 Pa)

The Different Types of Air Conditioning Equipment for IT Environments

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

Why Do I Need Precision Air Conditioning?

Hospital Application Guide. Cost-effective climate control for hospitals

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Defining Quality. Building Comfort. Heating and Cooling Coils

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

INSTALLER S & OWNER S MANUAL

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

F9MXE. Product Specifications

Cooling Capacity CFM in. w.c. (125 Pa)

Energy Efficient Homes: Air Conditioning 1

In recent years, formicary corrosion has wreaked havoc on. Micro-channel

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT. READ ONLY

KONRAD. Hybrid Fancoil Series

Owner s Manual Phoenix Arctic Max

HVAC Checklist - Long Form

Cooling Capacity CFM in. w.c. (125 Pa)

USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps)

Transcription:

Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful household particles. In addition, the Journal of Allergy and Clinical Immunology recommends keeping indoor relative humidity below 51% in order to deter dust mites and boost overall comfort of the home. What areas of the country need whole-house dehumidification? Clearly, the weather and climate varies in different regions throughout the country. But regardless of locale, customers need a system designed to control humidity separate from cooling. Any region with a summer dew point average above 55 F needs dehumidification separate from cooling. This would include cities such as Chicago St. Louis Baltimore Atlanta Orlando all have dehumidification needs. How do you determine if a city has a need for dehumidification? We start by identifying parts of the country with the average summer dew point is above 55 F because it represent areas where the humidity has the opportunity to rise above ideal levels ( a 55 F dew point represents 50% Rh at 75 F). Then we analyze the amount of time the outdoor temperature is between 55 F and 75 F. This calculated time value shows how often there would be a need for dehumidification in a home but there would be no Air Conditioning load. Without air conditioning run time, there is no moisture removal from the home. What is the Sensible Heat Ratio (SHR) of Air Conditioning and how does it affect dehumidification in homes? The Sensible Heat Ratio (SHR) is the percentage of cooling in an Air Conditioning evaporator coil that is devoted to sensible vs. latent energy removal. Manufacturers control the SHR of their equipment by the way they design the coils. The trend is to increase equipment SHR in order to increase the SEER rating of the A/C What is the Sensible Heat Ratio (SHR) of the dehumidifier coil? The evaporator and condenser coils each have two rows. This design is intended to remove maximum moisture, with a special fin design and fin configuration yielding a SHR of.50 vs. a typical air conditioner SHR of.75 or higher. What is the difference between latent and sensible energy? The Sensible energy is the energy that can be measured from a thermostat. Latent energy is the amount of moisture that is in the air. What is the Design Condition in Air Conditioning? What is a part-load condition and why does it affect dehumidification in homes? Air conditioning sizing is based on peak load conditions, a condition that is reached only 2-3% of the year. The other 97% of the year the air conditioner operates at part-load conditions (or is off), limiting the moisture removal in a home. Any time a home has a reduced Sensible Heat Load (evenings, cloudy days, etc) the air conditioner doesn t operate and indoor Rh can rise to uncomfortable levels. Page 1 of 6

What is causing the decrease in building Sensible Heat Load? Better building practices (for both existing and retro fit homes) are reducing the Sensible Heat Load of a building. The drive to improve energy efficiency (from better windows and insulation) has driven down the need for buildings to have large amounts of their cooling capacity dedicated to sensible cooling Why does an Air Conditioner use time delays in their fans? In an effort in increase the SEER rating in Air Conditioning, manufacturers recommend the use of a time delay fan. This allows the A/C compressor to shut off while continuing to run the HVAC blower. This feature can improve the SEER rating by.5 points. But that increased sensible efficiency comes at a cost to the moisture removal. A/C coils can hold a large amount of moisture ¼ to ½ gallon at the end of their cycles. By leaving the fan on, the moisture from the coil becomes re-evaporated back into the living space and can increase indoor Rh by over 10% How long does it take a new high efficiency A/C to get full moisture removal? New high efficiency Air Conditioner coils now require longer time to remove moisture in the home. According to recent research from ASHRAE, a new high efficiency evaporator coil can take 8-10 minutes to achieve full moisture removal rate. Older, less efficient A/C coils start removing the maximum moisture within 6 minutes of start-up. This change resulted from equipment manufacturers trying to get a higher SEER rating for their product. What happens to a home when its Air Conditioner is over sized? Oversized Air Conditioners tend to run very short cycles because they are able to quickly satisfy the temperature needs of the home. This means that they rarely reach the point at which they can remove any significant moisture in the home. What happens to a home when the outside conditions are below design conditions (cloudy days, evenings, and spring/fall)? The result is similar to when an Air Conditioner is over-sized; in a part load condition the air conditioner tends to run very short cycles. They rarely are able to remove significant moisture from the home. Model 1700 Operation What is a TXV valve and why do we need one? A Thermostatic Expansion Valve has the capability to adjust the volume of refrigerant flow based on the energy in the air, independent of the condensing pressure. This allows optimal performance of the unit throughout a broad operational range of 40 105 F. Manufacturers of residential portable dehumidifiers generally produce equipment with a fixed restriction device, like a capillary tube. This fixed device defines the limited temperature range in which the unit can operate. Typical residential dehumidifiers will have issues with ice forming on the evaporator coils starting at 65 F or lower due to this fixed performance window. Page 2 of 6

How many gallons of moisture does the unit remove per day? 1 pint of water is equal to 16 oz. Therefore, the unit removes 90 pints or 11.25 gallons per day. What is the unit s performance at different Rh and temperatures? The Aprilaire model 1700 whole home dehumidifier has been tested and certified to remove at least 90 pints per day at AHAM conditions (80º F 60% RH). High-capacity performance is maintained across a wide range of conditions, from hot indoor conditions to cool basements. Here are some examples: Inlet air temperature Inlet air Rh Pints per day 60º F 60% Rh 98 pints/day 70º F 60% Rh 100 pints/day 80º F 60% Rh 97 pints/day 70º F 40% Rh 70 pints/day 80º F 40% Rh 75 pints/day How big is the compressor? The compressor is a ~1 HP, 10300 BTU/hr Tecumseh Rotary. It uses R22 refrigerant. This is a field proven compressor used frequently in demanding mini-splits and PTACs. What is the cabinet made out of? The cabinet is made from Galvannealed Cold Rolled Steel, and is fully painted with powder coat. This is a proven, durable finish used on Aprilaire products for many years. What is the insulation made out of? The insulation is 1 EPS (Expanded Polystyrene) with an adhesive backing and aluminum foil face on the side exposed to air flow. This helps keep condensation from forming on the cabinet and also reduces the sound level of the unit. What is the evaporator coil temperature? The coil temperature will vary based on inlet air conditions, but it typically cools the incoming air about 20 F across the evaporator coil before reheating it in the condenser coil. What is the filter made of? The filter is MERV 8 at 275 cfm and should be cleaned or replaced annually. It is constructed from 45 ppi (pores per inch) flame retardant polyester foam with a polybonded, slit and expanded aluminum face and aluminum frame. What is the leaving air temperature? The leaving air temperature will depend on the inlet air conditions and the airflow (CFM). It typically will be about 95 F 100 F and 25% Rh. What price is the consumer willing to spend? Aprilaire consumer research showed price points in the range of $1500 - $2500 were acceptable for the comfort and wellbeing benefits delivered by the dehumidifier. This will vary by the degree of need, region, and complexity of the installation. Page 3 of 6

What refrigerant does the system use? R-22 was chosen for broad availability and acceptance. What is the warranty on the compressor? The compressor warranty is the same as the unit, two years. Typically, smaller compressors carry shorter warranties in order to keep costs down. This does not indicate a shorter life. Typicaly if a compressor is going to fail, it will do so in the first months after installation, which falls in the warranty period. Although it is common to have a 10 year warranty in larger HVAC equipment, the length of warranty does not indicate a shorter life for the Aprilaire unit. What is the temperature drop across the evaporator coil? Typically, the temperature will drop by 20 F, allowing the relative humidity to increase to the dew point and start condensing moisture from the air. What is the energy usage of the dehumidifier? Using the following assumptions at NORMAL indoor (Model 1700) inlet air conditions: Indoor Temperature: 75 F Indoor RH: 55% Model 1700 Air Flow: 275 CFM Typical Model 1700 power consumption at above conditions: 825W Electricity Rate: $0.09/kWh Cost of Operation per Hour: $0.075 Example: If the unit runs 24 hours per day at these conditions, it will cost approximately $1.80 per day. We have found that, once the humidifier brings the conditioned space to a steady state, the run time drops significantly. How does the unit know there is a need for dehumidification? The unit automatically turns on the dehumidifier blower for two minutes in a preset timeframe to sample temperature and dewpoint. You can customize the interval to 30 min, 1, 2 or 3 hours. If the house Rh is above set-point, the dehumidifier will then energize its compressor. This automatic control is built into the dehumidifier and requires no wires to the living space Why put a filter drier in the refrigerant line? This protects the TXV valve and compressor from potential contaminants and moisture, ensuring consistent, efficient and long-term operation of the dehumidifier. What are the benefits of fan cycling? Built-in Fan Cycling is a great intelligent feature for both dealers and consumers. Fan cycling mixes and evenly distributes air throughout the whole home, helps eliminate hot/cold spots in the home, and improves the performance of the air cleaner, dehumidifier, and humidifier. Model 1700 Installation and Service What is the drain pan made out of? The stainless steel drain pan is designed to resist corrosion and stands up to the extreme conditions from both the evaporator and condenser coil. Page 4 of 6

Does it need a trap? What kind of trap? The unit needs a trap due to the negative pressure inside the cabinet. This prevents the unit from sucking water or gasses back into the unit. The trap can be constructed of readily available copper tubing or common PVC fittings. The drain elbow extends out the bottom of the unit and turns 90 towards the side of the unit, which makes it easy to install a hose and trap. What is the drain fitting size coming out? Can flex tube be used? The elbow/fitting is ½ O.D. copper with no barb. Standard condensate hose will work fine in this application. Can you use extension cords? Extension cords can be used, but must be 12 or 14 gauge to handle the rated current and should be limited to 25 in length. How long can the duct work runs be? The length of duct runs is dependent on the particular HVAC system s operating pressures. Below are some examples:.4 wc = 240 of total equivalent flex duct.5 wc = 150 of total equivalent flex duct A complete table is listed in the Safety and Installation Instructions Manual with guidelines and limitations on duct lengths, elbows, etc. Do you need to increase the tonnage of the cooling system because of the heat produced by the dehumidifier? No, this should not be necessary. The air returning to the ducts is only 275 CFM of 95 F 100 F dry air. The air coming from the dehumidifier is blended with air in the duct work, before being delivered to the living space. The other important point to remember is that the indoor environment will feel more comfortable at warmer temperatures, due to the lower humidity. Can you reduce the AC tonnage because you will have reduced latent load? No, we do not recommend this. The air conditioner and dehumidifier will often work at different times, depending on the temperature and humidity control the home needs. Can we bring 100% outside air into the dehumidifier? We recommend against having outside air be the sole supply air to the Model 1700. Although the Model 1700 will work with many outside air conditions, it does not have enough capacity to bring outside air to a reasonable dewpoint in all cases. The Model 1700 is more effective and efficient when treating outside air that has been brought in using the Model 8126 Outside Air Ventilation Damper and then mixed with inside air in the return duct. When installed this way, there are other benefits as well. First, the ventilation control function in the 1700 can be used to control the damper and furnace blower to ensure the proper amount of fresh air. Second, the 1700 can act directly on the inside air of the home, conditioning it to the correct humidity level. Page 5 of 6

Does it have to be an Aprilaire filter? The filter is a special design for the model 1700 and should be purchased from Research Products. This will ensure proper pressure drops, even air distribution across the evaporator coil, and overall safe operation. Can you attach it to an existing humidistat? No, the Model 1700 needs to be controlled using either the automatic control in the unit, or the optional Living Space Control, Model 70. Each control has special built-in features that help the Model 1700 deliver exceptional performance. Is there a service port on the unit? The unit has two (2) Schrader Valves, to allow for field charging and evacuation. What is the minimum distance to the first supply outlet? The first supply outlet into a living space must be at least 6 downstream from where the dehumidifier deposits its air within the supply duct. If you don t meet this minimum, the recommendation is to have the HVAC fan turned on with the dehumidifier to ensure adequate mixing of the supply air to the living space. Other than dehumidification, what is the benefit of running the dehumidifier in a basement? Because the air coming from the dehumidifier is slightly warmer than the room temperature, there can be a slight warming effect in the basement. This will further assist in lowering the Rh of the basement, as the same air at higher temperatures has a lower Rh. What are the Electrical needs of the unit? It is 110-120 VAC, with a current draw of 9 AMPS. The total power is 825 Watts What does the unit weigh? 100 pounds Does the unit require any maintenance? Yes, the filter should be cleaned or replaced annually and the coil checked for contaminants to ensure pressure drops and even air distribution across the coils. Page 6 of 6