N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL



Similar documents
S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Air damper actuators

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Electric Rotary Actuator - On/Off or programmable control actuator

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

T7560A,B,C Digital Wall Module

VAV compact controller KNX / PL-Link

Duct Humidity Transmitter

Telefon (+45) Telefax (+45) Installation and operating manual

VAV compact controller KNX / PL-Link

Quick running actuator

Digital input modules

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

Series 71, 72, and 76 Modutrol IV Motors

HERZ-Thermal Actuators

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Know-how makes the difference. Electrical Actuators

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Installation Instructions

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

DUCT SMOKE DETECTOR D4120

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SIMRAD SD10 Sailboat Drive

Three-phase monitoring relay CM-PFE

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

EBS852 (Contrac) Power Electronic Unit

Assisted lift operated 2/2-way solenoid valves Type EV250B

Vario-Series Accessories

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Electronic Control Devices The European Product Catalogue 2007

ACS-30-EU-EMDR-10-MOD

HCE80/HCC80/HCE80R/HCC80R

Actuator for modulating control AME 435

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

PSR The compact range Description

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

5SV Residual Current Protective Devices

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Description. Dimensions. Features. precision works better

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Quick Connect. quick - simple - efficient.

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Cross Reference Modutrol IV Motor Cross Reference For Honeywell and Competitive Motors

Richter Twin Piston Quarter-turn Actuators

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

SMOKE DAMPERS IMOS DKI-1 TECHNICAL CONDITIONS TPI (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Solid-State Timer H3G

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Tool Turrets and Tool Discs

Smile. The All-In-One Heating Controller

RY2 miniature industrial relays

Material test chamber with mechanical convection

Addendum to the Operating Instructions

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Electronic Control Devices The European Product Catalogue 2007

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

Pneumatic actuators The Original! Technics of the top class.

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

SMS 4 / SMS 5 safety mat Product information

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Absolute Rotary Encoder E6CP

38 Series - Relay interface modules A

Pluggable interface relays CR-P Pcb relays

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Series 6000 Torque measured metal bellow coupling

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Protect IT MNS Motor Management INSUM. MPU - Multi Purpose Unit. - Catalogue - ABB

Control Devices Catalogue. Control Devices. Preferred and Standard Products

E-STOP relays, safety gate monitors

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

MCR1900 Media Converter 19-Slot Chassis

Transcription:

N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%, 5/6 Hz Power consumption See Table 1 on pg. 2. Ambient limits Ambient operating limits Ambient storage limits Relative humidity -2...+6 C -4...+8 C 5...95%, non-condensing Safety Protection standard IP54 as per EN 6529 Protection class II as per EN 673-1 GENERAL These direct-coupled damper actuators provide floating and 2-position control for: air dampers VAV units air handling units ventilation flaps louvers FEATURES Self-centering shaft adapter Access cover to facilitate connectivity Service/off for safe and easy servicing Rotation direction set using function selection switch Declutch for manual adjustment Rugged mechanical end limits Mountable in any orientation (no IP54 if upside down) CE-certified Lifetime Full strokes 6, Repositions 1.5 million Mounting Round damper shaft Square damper shaft Shaft length Feedback signal Limits 1...27 mm 1...18 mm; 45 steps min. 22 mm 1 ma at...1 V + 1mA -.5mA at 2 1V Torque rating see Table 1 on pg. 2 Runtime Rotation stroke 95 sec (6 Hz) / 11 sec (5 Hz or DC supply) 95 3 Dimensions see "Dimensions" on pg. 6 Weight (without cables) 1.35 kg (3 lbs.) U.S. Registered Trademark ENB-695GE51 R1112 Copyright 212 Honeywell Inc. All rights reserved

N2xxA, N34xxA DCAs FOR FLOATING AND 2-POSITION CONTROL PRODUCT DATA MODELS Table 1. Models order number supply voltage end switches power consumption torque N224A 24 Vac -- 6 VA / 6 W 2 Nm N224A-SW2 24 Vac 2 6 VA / 6 W 2 Nm N223A 23 Vac -- 8 VA / 8 W 2 Nm N223A-SW2 23 Vac 2 8 VA / 8 W 2 Nm N3424A 24 Vac -- 9 VA / 9 W 34 Nm N3423A 23 Vac -- 13 VA / 1 W 34 Nm OPERATION / FUNCTIONS 1 2 3 5 6 Fig. 1. Setting units and control elements Legend for Fig. 1: Self-centering shaft adapter Retainer clip Rotational angle scales (...9 / 9... ) Mechanical end limits (2 Nm [177 lb-in] models, only) Declutch button Anti-rotation bracket Rotation direction switch Access cover 4 7 8 Dir (" ") is the default shipping position. When the rotation direction switch is set to this position, the actuator internally switches the rotation direction control signals as stated in section "Wiring Diagrams". "Service/Off": When the rotation direction switch is set to this position, all actuator rotary movement is cancelled and all control signals are ignored, thus enabling the actuator to be manually operated (see section "Manual Adjustment"). The user can then perform maintenance / commissioning without having to remove power from the actuator. To return to the control mode, simply move the rotation direction switch to its former setting. Rev (" "): When the rotation direction switch is set to this position, the actuator follows signals as stated in section "Wiring Diagrams". Two-Position or Floating Control The actuator is capable of being operated by either a twoposition (with continued power supply) or a floating controller. Refer to wiring diagrams for correct connection. Position Indication The edge (see arrow in Fig. 3) of the hub adapter indicates the rotation angle position with respect to the rotational angle scales (...9 / 9... ). Rotary Movement Modes The rotation direction (CW or ) is selected using the rotation direction switch, thus eliminating the need to re-wire. To ensure tight closing of the dampers, the actuator has a total rotation stroke of 95. As soon as operating power is applied, the actuator may start to run. When power is removed, the actuator remains in position. For actuator-controller wiring instructions, see section "Wiring" on page 3. 3 6 6 3 Rotation Direction Switch Dir Service/Off Fig. 3. Position indication Manual Adjustment The gear train can be disengaged using the declutch button, permitting the actuator shaft to be manually rotated to any position. ENB-695GE51 R1112 2 Rev Fig. 2. Rotation direction Switch

N2xxA, N34xxA DCAs FOR FLOATING AND 2-POSITION CONTROL PRODUCT DATA Limitation of Rotation Stroke Two mechanical end limits (adjustable in 5 increments) are provided to limit the angle of rotation as desired (see Fig. 4). Fig. 4. Mechanical end limits The mechanical end limits must be securely fastened in place. It is important that they properly mesh with the rotational angle scales when the screws are tightened. Internal End Switches NOTE: Applicable to models with internal end switches, only. The internal end switches are set to change from "common" to "normally open" at angles of 5 and 85, respectively, from the totally counterclockwise position. -2.5 5 1 15 75 8 85 9 92.5 internal end switch actuator scale: clockwise end switch scale CW internal end switch 5 1 15 75 8 85 9 actuator scale: counterclockwise 92.5 9 85 8 75 15 1 5-2.5 Fig. 5. Internal end switches INSTALLATION These actuators are designed for single-point mounting. Mounting Instructions All information and steps are included in the installation instructions supplied with the actuator. Fig. 6. Mounting for IP54 Self-Centering Shaft Adapter The self-centering shaft adapter can be used for shafts having various diameters (1...27 mm) and shapes (square or round). In the case of short shafts, the shaft adapter may be reversed and mounted on the duct side. Stroke Limitation with Mechanical End Limits The mechanical end limits enable the stroke to be limited from...9 in increments of 5. Wiring Connecting to the Power Supply In order to comply with protection class II, the power source of 24 V actuators must be reliably separated from the network power supply circuits as per DIN VDE 16, part 11. Access Cover To facilitate wiring the actuator to the controller, the access cover can be detached from the actuator. IMPORTANT Remove power before detaching the access cover. Once the access cover has been removed, please take care to avoid damaging any of the parts now accessible. Mounting Position The actuators can be mounted in any desired orientation (no IP54 if mounted upside down; see Fig. 6). Choose an orientation permitting easy access to the actuator's cables and controls. Fig. 12. Access cover (models with internal end switches) Depending upon the model, the access cover may have one or two terminal blocks, including a layout with a description for each of the terminals. 3 ENB-695GE51 R1112

N2xxA, N34xxA DCAs FOR FLOATING AND 2-POSITION CONTROL PRODUCT DATA WIRING DIAGRAMS A1: Nxx24A wired for 2-POSITION CONTROL A2: Nxx24A wired for FLOATING CONTROL A3: Nxx23A wired for FLOATING CONTROL 24 V~/+ A4: Internal end switches (NxxxxxA-SW2)! CW 24 V~/+! CW N 23 V~, L CW CW S6 S5 S4 S3 S2 S1 MAX. 5 (3) A S1 / 23V 24V 23V 24V SELV S4 / CW 23V 24V 24V SELV 23V OPTIONAL ACCESSORIES Auxiliary Switch Kit Order no.: SW2 The auxiliary switches are field-installable parts providing two SPDT freely-adjustable switches. Fig. 7. Actuator with access cover removed (models with internal end switches) A B A B S3 S1 S2 9 45 S6 S4 S5 9 C D C D SPARE PARTS There are no spare parts available 4 ENB-695GE51 R1112

N2xxA, N34xxA DCAs FOR FLOATING AND 2-POSITION CONTROL PRODUCT DATA DIMENSIONS 13 mm SHAFT SHAFT ADAPTER ADAPTER (REAR) 95 48 mm 22.6 mm 223 mm 92 mm min. 6 mm 1 mm 132... 152 mm 23 mm (+/-.5 mm) 2 mm ANTI-ROTATION BRACKET 7 mm 2 mm 13 mm 5 mm (+.5, -.1 mm) Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 7111 Schönaich / Germany Phone: (49) 731 6371 Fax: (49) 731 637493 http://ecc.emea.honeywell.com Subject to change without notice. Printed in Germany ENB-695GE51 R1112