Technical Requirem ent



Similar documents
SCADA and Monitoring for Solar Energy Plant

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

GSM Voice Auto Dialer & SMS Sender JC-999

Quectel M72 Development Board

PCS300 Universal IP Reporting Module V1.0

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

Car Alarm Tracker Manual

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Product Specification instalert Rapid Messenger Variable Message Sign

Premium Server Client Software

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

2 Enterprise. CounThru TM. Managed Print Solution. CounThru TM 2 Enterprise Managed Print Solution WHITE PAPER. Introduction. What is CounThru TM

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

ABB PSPS Erich Steinmann; Generator control-2013

minova technology electronics

SNMP Web Management. User s Manual For SNMP Web Card/Box

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Display Message on Notice Board using GSM

, User s Manual

Gilsson AlwaysFind Web Base Fleet Management AVL & Personal GPS Trackers

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Phase Modular Finally the benefits of Modular ups are for all

savic-net for Integrated Building Management System

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

GPS Vehicle tracker (GPS+GSM+SMS/GPRS) GT06 User Manual

GPS Monitoring Device

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

L5354 ControlNet Communications Interface

CCTR-800 Portable Real Time GPS Tracker

Metis Products GPRS AutoDialer Version 2.0

Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI

Intelligent Vibration Monitoring

User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies

999GPS Tracking Platform Operation Guide

CCTR-810 Real Time Car GPS Tracker

Executive Summary. Technical Description

Temperature & Humidity SMS Alert Controller

ProCurve Networking. Troubleshooting WLAN Connectivity. Technical White paper

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Distribution Voltage Regulators

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

GSM Interfacing Board

SHORT TRAINING COURSES

The Business case for monitoring points... PCM architecture...

SuperGuard VT-05 Vehicle Tracking Device

User Guide for the Volvo On Call mobile application

Ultimate Server Client Software

Link 2 Vehicle Maintenance System

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Our Customer Relationship Agreement IINET VDSL2 SERVICE DESCRIPTION

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

FM4100 USER MANUAL V1.4

Air Conditioning System

Remote Monitoring and REC 501 Control Unit Product Guide

32VFD Variable Frequency Drives for Centrifugal Chillers

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options


Application Note: Monitoring Branch Circuit Loads in Critical Facilities

How To Use Windows Live Family Safety On Windows 7 (32 Bit) And Windows Live Safety (64 Bit) On A Pc Or Mac Or Ipad (32)

BLAST MONITORING Solutions

Hardware & Software Solutions

User manual DC Safelog. Edition

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SMS Alarm. User Manual

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Requirements 64 Kbps N x 64 Kbps Hot line E1 Type Type Type 3 ( DC version) Type 3 (AC version)

Transponder for GainMaker Amplifiers

Temperature & Humidity SMS Alert Controller

Cellular Edition TM- CELL400 User Guide. 1 TM- CELL400 Rev Temperature@lert

SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi

Domonial, le Sucre. Easy to Use Intruder Detection Systems

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

LA-9011 GSM/GPS Tracker User Manual

Product Description. HiLink E3531 HSPA+ USB Stick V100R001 HUAWEI TECHNOLOGIES CO., LTD. Issue 01. Date

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.

Dyeing Programmer DP - 01

MCOM VEHICLE TRACKING SYSTEM MANUAL

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Kurz Instruments Inc. Document AV Document Title: MFTB Event Code Definitions. MFT B-Series Event Codes

808 Vehicle Real Time GPS Tracker

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

ATS - Automatic Changeover

Machine control going www - Opportunities and risks when connecting a control system to the Internet

Question Shall the Tender include installation of the central server application on a redundant server?

Temperature & Humidity SMS Alert Controller

The Ultimate Truck Stock Motor

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

In VehIcle MonItorIng SolutIonS

Re-Tender. for. Supply and Installation of the. Student Biometric Attendance System. Indian Institute of Technology Jodhpur

Transcription:

Reasoned document for draft Functional Requirement of system of Centralized coach Monitoring system (CCMS) for air conditioned LHB EOG coaches of ndian railway. SL. No. Clause Title Clau se No Technical Requirem ent Technical Requirem ent The CCMS system shall comprise of a GSM-GPRS enabled communication "NODE" on the coach that collects information from Microprocessor controller of RMPU for LHB and Double Decker AC coaches. t shall transmit it to a centralized database server. The server system will process this data to generate value added information for analysis and corrective room. actions at control The CCMS shall works with different make of microprocessor Microcontroller based manufactured n rolling stock application there is chance communication failure for some time when the system is running under weak signaling area, in such cases there is a possibility that the information might be delayed due to network/weak signaling issues. RDSO need to specify the communication protocol in between microprocessor based Microcontroller and The revised clause shall be as under " The CCMS system shall comprise a GSM-GPRS enabled communication "NODE" in individual coaches and centralized computer in power car /pantry unit. The centralized computer in power car/pantry car shall have LCD display system which will collect information from Microprocessor controller of RMPU for LHB and Double Decker AC coaches. Centralized computer shall display the fault data and also transmit it to a centralized database server in Railway Divisiqnal control room. The centralized computer in power car as well as server system in Railway Divisional control room will process this data to generate value added information for analysis and corrective actions at control room. " ~ The revised clause 6.3 shall be as \.A. under " The CCMS shall works with different make of microprocessor based Microcontroller manufactured by ROSa

by ROSO approve sources as CCMS unit. approve sources as per ROSO per spec no. ROSOl specification no. PE/SPEC/AC/0139-2009(Rev- ROSO/PE/SPEC/AC/0139-2009(Rev-1 ) 1) for AC LHB EOG coaches for AC LHB EOG coaches. This Microprocessor controller will have a standardized communication protocol for sending the data to centralized computer in standard format and it will be issued by ROSa. " 3 Technical 6.6 System shall monitor the At present monitoring of OL The revised clause shall be as under Requirem following;- Temperature pressure is not in the scope ent Low pressure, High Pressure of RMPU control unit. " 6.9 CCMS shall monitor the following: and Oil pressure in AC system a) Auto mode working of Air Conditioning unit b) Temperature (return air, supply air temperature and ambient temperature) c) Pressure (Low pressure and High Pressure in AC system) d) LP & HP tripping e) Compressor tripping f) AC motors tripping J g) Other inputs and output mentioned in Annexure A of this document.

Construct; on and fundamen tal requireme nts 7. 2 'u sing the above hardware ports, the system shall be capable of being configured for data retrieval up to 24 coach systems in a time multiplexed manner. Data retrieval shall be deterministic in nature. Specific time to service shall be maintained for various units connected to the Master. Please clarify the mode of communication in between RMPU and CCMS Module, Same time the communication protocol in between RMPU and CCMS Module. " Using the above hardware ports, the system shall be capable of being configured for data retrieval up to 24/26 coach systems in a time multiplexed manner. Data retrieval shall be deterministic in nature. Specific time to service shall be maintained units connected to the Master. for various There will be a standardized communication protocol between Microprocessor controller and CCMS for sending' the data to centralized computer in standard format and it will be issued by ROSa Software for Server System installed at divisional and Zonal Headquar, ter 8.1 A simple window based! application software shall be built on a server system using standard database for receiving the data at the server end. The data so received shall be accessible remotely using web technologies. The data so accessed should be capable of being imported into a standard analysis package like MS- Main server will also interfaced with 3/4 G modem to receive the data from CCMS Module A simple window based/open application software shall be built on a server system using standard database for receiving the data at the server end. The data so received from CCMS module shall be accessible remotely using web technologies. The data so accessed should be.~

EXCEL for value added analysis. capable of being imported into a standard analysis package like MS-EXCEL for value added analysis. Sr. Clause Clau No. Title se No Comments of Mis. A. Paul nstruments & Co. 6 Technical 6.7 Requirem ent The nominated subscribers shall get "SMS Alert' coach no. wise whenever following " The nominated subscribers shall get 'SMS Alert' coach no. wise whenever following e) AC unit not working due to any other fault f) Any other alert which are monitored online as per a) LP & HP tripping b) Compressor tripping c) Blower motor tripping d) Condenser motor tripping e) AC unit not working due to any other fault f) Any other alerts which are monitored online as per requirement of the subscriber.

6.4. Regular reports of functioning of Air-conditioned system of coaches shall be transmitted for real time monitoring with 'SMS' in case of any fault to the 10 Our Suggestion: SMS, should be generated from the server end. Kindly suggest who will pay the SMS service pack. t costs Rs.O.09 per SMS. The application software shall allow configuration Number of SMS. of SMS generated shall be proportional to number of faults over which the system provider has no control. SMS packs should be to railway account. As such SMS service nuisance, is a and only highly exceptional alerts like motor blocked or emergency operation be sent through mode of plant should SMS. " Regular reports of functioning of Airconditioned system of coaches shall be transmitted for real time monitoring with 'SMS' in case of any fault to the 10 nominated subscribers. Nomination of subscribers shall be possible by user at any point of time from the centralized control. Additionally, there are 2 more clauses in FRS "3.2 Firm shall provide window based/open application software for user terminal along with operation & maintenance cum trouble shooting manual with each supply lot. The facility of providing SMS pack and nternet services shall be in the scope of supplier/railways, which will be as per the terms and conditions of tender. 3.3 SMS. Number of SMS generated shall be restricted to emergency faults and alerts of air-

CCMS shall monitor the following: a) Auto/bypassed mode working of Air Conditioning b) Temperature (return air, supply air temperature ambient temperature) and unit c) Pressure (Low pressure, High Pressure and Oil pressure in AC system) g) Other inputs and output mentioned document. in Annexure A of this These data shall be transmitted to the control room though GPRS/GSM in every 5 The given interlock Auto/bypassed mode is not provided. Bypass mode can be detected only if the system is interfaced with a load monitoring meter (current meter) or assignment of an interlock on the MPC for bypass sensing (less useful). Fault reporting to report should be instantaneous. Even logs should be once in every 5 minutes. Firm has to modify the wirings and circuits accordingly to detect bypass mode through interlock on the microprocessor for bypass sensing. a) Auto mode/bypass working of Air Conditioning unit b) Temperature (return air, supply air temperature and ambient temperature) c) Pressure (Low pressure and High Pressure in AC system) d) LP & HP tripping e) Compressor tripping f) AC motors tripping g) Other inputs and output mentioned in Annexure A of this document. These data shall be transmitted to the centralized computer in power car / pantry car and Railway Divisional control room though GPRS/GSM in every 5 Minutes. Fault reporting shall be instantaneous and event logs shall be

Software for Server System installed at divisional and Zonal Headquarter: Use of web technologies allows usage of cloud hosting services. Software should be installed on a cloud based server. nstalling of software at zonal HQ will require Static P, T infrastructure, Users will access the cloud based server etc. through a web browser URL link. "8.1 A simple window based/open application software shall be built on a server system using standard database for receiving the data at the server end. The data so received from CCMS module shall be accessible remotely using web technologies. The data so accessed should be capable of being imported into a standard analysis package like MS-EXCEL for value added analysis. Northern Railway The scope of the work to include setting up of a control room with complete set up like LED monitors, servers etc. revised clause 3.1.5 is as under" User terminal at Railway Divisional Control room.= 1 set"

3.0 n Para 3.0 window based application is not agreed, instead it should be open system based. Revised clause 3.2 is as under "Firm shall provide window based/open application software for user terminal along with Operation & maintenance cum trouble shooting manual with each supply lot. The facility of providing SMS pack and nternet services shall be in the scope of supplier/railways, which will be as per the terms and conditions of tender. ", it is not clarified who will provided the protocol. Protocols shall be given by the Railways and Railways shall be provided protocols of microprocessors by the respective OEMs at no cost. This will make development possible by any software vendor, otherwise it will become a PAC case. "The CCMS shall works with different make of microprocessor based Microcontroller manufactured by ROSO approve sources as per ROSO specification no. ROSO/PE/SPEC/AC/0139-2009(Rev-1 ) for AC LHB EOG coaches. This Microprocessor controller will have a standardized communication protocol for sending the data to the centralized computer in a standard format and which will be issued by ROSO.

"A simple window based/open application software shall be built on a server system using standard database for receiving the data at the server end. The data so received from CCMS module shall be accessible remotely using web technologies. The data so accessed should be capable of being imported into a standard analysis package like MS-EXCEL for value added analysis" Warr Warranty clause Warranty clause shall be! 2 clauses have been added in the final anty suitably defined with minimum 5 year warranty. draft of FRS Warranty Guarantee of complete equipment shall be as per RS conditions. 12.1 The complete CCMS unit shall be put on rigorous field trial for 30 days in nominated rake of Rajdhani/Shatabdi train. After successful field trial, the feedback of user Railway will be sent to ROSa for further course of action. "

Clause for GPRS charges to be paid by contractor shall be included for 5 years. Revised clause 3.2 " Firm shall provide window based/open application software for user terminal along with Operation & maintenance cum trouble shooting manual with each supply lot. The facility of providing SMS pack and nternet services shall be in the scope of supplier/railways, which will be as per the terms and conditions of tender. Para 6.4 shall be further clarified input power to the CCMS unit shall be 11OV DC/AC±30%. that the nomination of subscribers shall be possible by user at any point of time from centralized the administrator control by The revised clause 6.1 shall be as under " The input power to the CCMS unit is 110 Volts DC/AC +1-30% for End On Generating coaches." (EOG) LHB type AC The revised clause 6.4 shall be as under "Centralized computer to be mounted in power carl pantry car for collecting, processing, storing and downloading the data of air conditioning of connected AC coaches and shall be capable of transmission and reception of air conditioning data to centralized data server of control room as well as 10 nominated subscribers through SMS using GSM/GPRS or latest technology. The nomination of subscribers shall be possible by user at any point of

Para 24 coaches shall be modified for at least The revised clause 7.2 shall be as under 7.2 28/30 coaches as the rake " Using the above hardware ports, the composition is increasing day by day. system shall be capable of being configured for data retrieval up to 24/26 coach systems in a time multiplexed manner. Data retrieval shall be deterministic in nature. Specific time to service shall be maintained for various units connected to the Master. The system shall preferably be non polar type. Clause 11.9 is in FRS " Reverse polarity test: Para 12.1 shall be modified by Screen printing is not deleting either screen printed advisable. as the unit shall have name/rating information only by etching process or by engraving. The unit shall remain functional after applying 200Volts DC at 110V volts DC input terminal for one minute in correct polarity. as well as in reverse polarity. Revised clause 13.1 shall be as under "The CCMS Unit shall be provided with a name/rating plate on the enclosure. The following information shall be available by either etching or engraving process on the name plate of aluminum with white background and black letters.

Rosa to examine & include suitable clause how to monitor 1000 or more coaches with this CCMS. t should be on the lines of existing SCAOA system operating successfully in TRO, i.e. it should be possible to monitor & control in real time, the desired parameters in an AC coach/rake & in a suitable control room by a team of experts. These people can also advice in case of difficulty to the escorting staff if required. The system should be accordingly renamed as a complete control & monitoring system of AC coacheslrakes.