2008 Hitachi, Ltd., Hitachi Data Systems Corporation, ALL RIGHTS RESERVED Notice: No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose, without the express written permission of Hitachi Data Systems Corporation (hereinafter referred to as Hitachi Data Systems ). Hitachi Data Systems reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. Hitachi Data Systems products and services can only be ordered under the terms and conditions of Hitachi Data Systems applicable agreements. All of the features described in this document may not be currently available. Refer to the most recent product announcement or contact your local Hitachi Data Systems sales office for information on feature and product availability. This document contains the most current information available at the time of publication. When new and/or revised information becomes available, this entire document will be updated and distributed to all registered users. Trademarks Hitachi, the Hitachi logo, and Hitachi Data Systems are registered trademarks and service marks of Hitachi, Ltd. The Hitachi Data Systems logo is a trademark of Hitachi, Ltd. USP V, USP VM, Tagmastore, USP, NSC, AMS, WMS, HiCommand, Hitachi Freedom Storage, Lightning 9900, Thunder 9200, and Thunder 9500 are trademarks of Hitachi Data Systems Corporation in the United States and other countries. Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation in the United States and other countries. Microsoft Exchange Server and Microsoft SQL Server are product names of Microsoft Corp. Windows Server is a trademark of Microsoft Corp. in the U.S. and other countries. All other brand or product names are or may be trademarks or service marks of and are used to identify products or services of their respective owners. Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide iii
Notice of Export Controls Export of technical data contained in this document may require an export license from the United States government and/or the government of Japan. Please contact the Hitachi Data Systems Legal Department for any export compliance questions. Document Revision Level Revision Date Description MK-96HC127-P February 2006 Preliminary release MK-96HC127-00 June 2006 Initial release, supersedes and replaces version P MK-96HC127-01 January 2007 Update release for V5.5, supersedes and replaces version 00 MK-96HC127-02 April 2007 Update release for V5.7, supersedes and replaces version 01 MK-96HC127-03 October 2007 Update release for V5.8, supersedes and replaces version 02 MK-96HC127-04 March 2008 Update release for V5.9, supersedes and replaces version 03 MK-96HC127-05 May 2008 Update release for V6.0, supersedes and replaces version 04 Referenced Documents Hitachi Protection Manager User s Guide (MK-94HC070) Hitachi Protection Manager Console User s Guide (MK-94HC071) Hitachi Protection Manager Command Reference (MK-94HC072) Hitachi Protection Manager Messages (MK-94HC073) Related Documents Hitachi RAID Manager Shadow Copy Provider for Microsoft Volume Shadow Copy Service (VSS) Installation Guide (MK-94RD166) Hitachi Command Control Interface (CCI) User and Reference Guide (MK-90RD011) Hitachi TagmaStore Adaptable Modular Storage Command Control Interface (CCI) User and Reference Guide (MK-95DF701) Hitachi Freedom Storage Thunder 9520 V Series Command Control Interface (CCI) User and Reference Guide (MK-94DF687) Hitachi Freedom Storage Thunder 9500 V Series Command Control Interface (CCI) User and Reference Guide (MK-92DF609) Hitachi Freedom Storage Thunder 9200 Command Control Interface (CCI) for ShadowImage User and Reference Guide (MK-91DF557) Readme and Release Notes Contents These files can be found on the installation CD. They contain requirements and notes for use of Hitachi Protection Manager that may not be fully described in the manual. Be sure to review these files before installing Hitachi Protection Manager. iv Preface
Preface The Hitachi Protection Manager Getting Started Guide for VSS Backup of Microsoft Exchange Server describes how to install and setup Hitachi Protection Manager for Microsoft Exchange, using a Volume Shadow Copy Service (VSS) integration scenario. It also contains information about the prerequisite components, which include CCI, RM Shadow Copy Provider, and PVOL/SVOL setup. This document is not intended to replace product manuals; rather, it is a concise reference for those who need to implement Protection Manager and must quickly grasp the implementation procedures. Therefore, this document should be used as a supplemental reference to the complete product manuals and release notes. Please consult those documents for detailed instructions and background information. Software Version This document revision applies to Hitachi Protection Manager version 6.0. Comments Please send us your comments on this document. Make sure to include the document title, number, and revision. Please refer to specific section(s) and paragraph(s) whenever possible. E-mail: doc.comments@hds.com Fax: 858-695-1186 Mail: Technical Writing, M/S 35-10 Hitachi Data Systems 10277 Scripps Ranch Blvd. San Diego, CA 92131 Thank you! (All comments become the property of Hitachi Data Systems Corporation.) Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide v
vi Preface
Contents Chapter 1 Overview of the VSS Backup... 1 1.1 Understanding the VSS Backup Procedure... 2 1.1.1 Reviewing the Process Flow... 3 Chapter 2 Reviewing Prerequisite Tasks for VSS Backup...5 2.1 Reviewing and Gathering Requirements... 6 2.1.1 Hardware and Server Requirements... 7 2.1.2 CCI Requirements... 8 2.1.3 VSS Hardware Provider Requirements... 9 2.1.4 Microsoft Exchange Server Requirements... 9 2.1.5 Other Requirements...10 2.2 Reviewing the Support Matrices...11 2.2.1 VSS versus Subsystem and Copy Functions...11 2.2.2 VSS versus Volume Manager and Clusters...11 2.2.3 Protection Manager Functions and Prerequisite Versions...12 Chapter 3 Configuring the Microsoft Exchange Database for VSS Backup... 15 3.1 Preparing the Microsoft Exchange Database for VSS Backup...16 3.1.1 Configuring the Storage Volume...16 3.1.2 Configuring the Server Volume...17 3.1.3 Setting up CCI (RAID Manager)...18 3.1.4 Setting up RM Shadow Copy Provider...22 Chapter 4 Installing and Setting up Protection Manager... 23 4.1 Gathering and Installing the Required Components...24 4.2 Setting up the Microsoft Exchange Server...25 4.3 Setting up the Import (Backup) Server...32 4.4 Setting up the Exchange Verify Tool...36 4.4.1 Setting up for Exchange Server 2003...36 4.4.2 Setting up for Exchange Server 2007...36 Chapter 5 Troubleshooting... 41 5.1 Troubleshooting VSS Backup Errors...42 5.2 Calling the Hitachi Data Systems Support Center...44 Acronyms and Abbreviations... 45 Index... 47 Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide vii
List of Figures Figure 1-1 VSS Backup Process... 2 Figure 2-1 Example Hardware and Server Configuration... 6 Figure 4-1 Adding a Physical Disk to Exchange Cluster Group... 27 Figure 4-2 Configuration Settings: Step 1/9... 27 Figure 4-3 Operation Setup: Step 2/9... 28 Figure 4-4 RAID Manager Linkage: Step 3/9... 28 Figure 4-5 VSS Definition: Step 6/9... 29 Figure 4-6 VSS Environment: Step 7/9... 29 Figure 4-7 Protection Manager Service: Step 8/9... 30 Figure 4-8 Update Dictionary Map: Step 9/9... 30 Figure 4-9 KAVX16308-W Warning dialog... 31 Figure 4-10 Configuration Settings: Step 1/9... 34 Figure 4-11 RAID Manager Linkage: Step3/9... 34 Figure 4-12 KAVX16308-W Warning dialog... 35 Figure 4-13 Input Servers Dialog Box... 38 Figure 4-14 Check Results Dialog Box... 38 Figure 4-15 Result Dialog Box... 39 List of Tables Table 1.1 VSS Backup Process Flow... 3 Table 2.1 List of Hardware and Server Requirements... 7 Table 2.2 List of CCI Requirements... 8 Table 2.3 List of Hardware and Server Requirements... 9 Table 2.4 Storage Subsystems and Copy Functions Matrix... 11 Table 2.5 Volume Manager and Cluster Support Matrix... 11 Table 2.6 Support Matrix for Array Microcode USP / NSC or 9970V / 9980V... 12 Table 2.7 Support Matrix for Array Microcode AMS / WMS or 9570V (9580V)... 13 Table 3.1 Sequence of Volume Configuration and Installation Steps... 16 Table 5.1 Error Causes and Troubleshooting Steps... 42 viii Contents
Chapter 1 Overview of the VSS Backup This chapter provides an overview of the VSS Backup process. Understanding the VSS Backup Procedure (section 1.1) Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 1
1.1 Understanding the VSS Backup Procedure Figure 1-1 provides a visual representation of the VSS backup process. The Protection Manager main program is designed to be installed on the production Exchange server, but it requires a separate physical server called the Import server. The Import server can work as a Backup server to backup data from SVOL to TAPE (you cannot assign a server within an Exchange cluster). The two main requirements for an Import server are that Protection Manager: Hides the INQUIRY attribute of the target SVOL from the Import server Unmounts the target SVOL from the Import server These are part of the Microsoft guidelines for VSS compliance. The processes running on both servers work together to perform VSS backup. Figure 1-1 VSS Backup Process 2 Chapter 1 Overview of VSS Backup
1.1.1 Reviewing the Process Flow Table 1.1 lists the order of the processes for the VSS Backup procedure. Please note that the Protection Manager Service on the Exchange server and Import server are started prior to running the Protection Manager backup command. Afterward, Protection Manager is ready to execute the drmexgbackup command, while the -mode vss option on the Exchange server invokes the entire backup process. Regarding the Exchange database states: Online indicates that the read and write access is available. Online (Freeze) indicates that the read access is available, but the write access is pending. Table 1.1 VSS Backup Process Flow Step Server Procedure CCI Pair Status Exchange Database 1 Exchange Protection Manager checks the cluster resources related to the target Exchange server, if cluster environment 2 Exchange Protection Manager gets the information of the Exchange information store 3 Exchange Protection Manager communicates to the Import server by using Protection Manager Service 4 Exchange Protection Manager gets the physical object mapping information (mount point, Harddisk#, CCI copy pair name, SERIAL#, LDEV# and so on) from its internal repository 5 Exchange Protection Manager selects the target SVOL for this VSS backup 6 Exchange Protection Manager starts-up the CCI instance, if not started 7 Exchange Protection Manager sets the CCI environment variables (HORCMINST, HORCC_MRCF) for the pair operations 8 Exchange Protection Manager checks the target CCI copy pair status 9 Exchange Protection Manager resyncs (pairresync) the target CCI copy pair, if not PAIR status 10 Exchange Protection Manager deletes the old backup catalog information in its internal repository 11 Import Protection Manager hides the INQUIRY attribute of the target SVOL from the Import server 12 Exchange Protection Manager checks whether the target CCI copy pair status is PAIR PSUS/SSUS or PAIR PAIR or COPY PAIR Online Online Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 3
Step Server Procedure CCI Pair Status Exchange Database 13 Exchange Protection Manager requests VSS to keep consistent image as Shadow Copy and then VSS asks the VSS writer (Exchange Server) to freeze I/O operations 14 Exchange VSS asks the VSS provider (RM Shadow Copy Provider) to split the target CCI copy pair 15 Exchange VSS asks the VSS writer (Exchange Server) to thaw I/O operations 16 Exchange Protection Manager checks whether the CCI copy pair status is PSUS/SSUS 17 Import Protection Manager requests VSS to import (mount) the target SVOL to the Import server 18 Import Protection Manager verifies the backed up Exchange data by using ESEUTIL command 19 Import Protection Manager unmounts the target SVOL from the Import server 20 Exchange Protection Manager resisters the backup catalog information to its internal repository PAIR PSUS/SSUS Online (Freeze) Online 4 Chapter 1 Overview of VSS Backup
Chapter 2 Reviewing Prerequisite Tasks for VSS Backup This chapter describes all components that are required for VSS Backup. Reviewing and Gathering Requirements (section 2.1) Reviewing the Support Matrices (section 2.2) Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 5
2.1 Reviewing and Gathering Requirements The Import server (Backup server) is required even if backed up data (SVOL) is not intended to be backed up to tape. This is because the Backup server imports VSS snapshots and verifies the Exchange database, as illustrated in the following example. Figure 2-1 Example Hardware and Server Configuration 6 Chapter 2 Reviewing Prerequisite Tasks for VSS Backup
2.1.1 Hardware and Server Requirements Table 2.1 lists the hardware and server requirements. Table 2.1 List of Hardware and Server Requirements Requirement Details Remarks Operating Systems Windows Server 2003 Enterprise Edition (no SP) Hotfix: KB833167 Protection Manager 4.1 or later Windows Server 2003 Standard Edition (SP1) Windows Server 2003 Enterprise Edition (SP1) Windows Server 2003 Datacenter Edition (SP1) Windows Server 2003 R2, Standard Edition Windows Server 2003 R2, Enterprise Edition Windows Server 2003 R2, Datacenter Edition Hotfix: KB891957 Hotfix: KB903650 (online restore MSCS extended maintenance mode) Hotfix: KB912063 Protection Manager 4.1.1 or later Windows Server 2003 Standard Edition (SP2) Windows Server 2003 Enterprise Edition (SP2) Windows Server 2003 Datacenter Edition (SP2) Windows Server 2003 R2, Standard Edition (SP2) Windows Server 2003 R2, Enterprise Edition (SP2) Windows Server 2003 R2, Datacenter Edition (SP2) Hotfix: KB903650 (online restore MSCS extended maintenance mode) Protection Manager 5.7.0 or later Windows Server 2003 Standard x64 Edition (SP1) Windows Server 2003 Enterprise x64 Edition (SP1) Windows Server 2003 Datacenter x64 Edition (SP1) Windows Server 2003 R2, Standard x64 Edition Windows Server 2003 R2, Enterprise x64 Edition Windows Server 2003 R2, Datacenter x64 Edition Hotfix: KB891957 Hotfix: KB903081 Hotfix: KB903650 (online restore MSCS extended maintenance mode) Hotfix: KB912063 Protection Manager 5.7.0 or later Windows Server 2003 Standard x64 Edition (SP2) Windows Server 2003 Enterprise x64 Edition (SP2) Windows Server 2003 Datacenter x64 Edition (SP2) Windows Server 2003 R2, Standard x64 Edition (SP2) Windows Server 2003 R2, Enterprise x64 Edition (SP2) Windows Server 2003 R2, Datacenter x64 Edition (SP2) For Exchange Server 2003 For Exchange Server 2003 For Exchange Server 2003 For Exchange Server 2007 For Exchange Server 2007 Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 7
Requirement Details Remarks Hotfix: KB903650 (online restore MSCS extended maintenance mode) Protection Manager 5.7.0 or later Use the same OS version across Exchange server and Import server (Backup server) The combination of Windows server2003(x64) on the Exchange server and Windows2003(32 bit) on the Import server is available. Please see the release note for the detail. Windows Server 2003 Enterprise Edition Installation Host Bus Adapter (HBA) Driver Command Device Access Uninstall the current version before installing the most recent version. Due to a known issue with the interference with VSS functions, never perform an upgrade installation. Use the same HBA driver for Exchange server and Backup server (StorPort is recommended). The HBA driver supports VSS functions. The Exchange server and the Import (Backup) server must have access to the command device of the target storage subsystem. 2.1.2 CCI Requirements Table 2.2 lists the CCI requirements. Table 2.2 Requirement Installation List of CCI Requirements Details CCI (RAID Manager) must be installed on both the Exchange server and the Import (Backup) server. The installation path should be the Windows system drive (otherwise, VSS does not properly function). Commands CCI copy pairs must be created before executing Protection Manager commands. Protection Manager commands operate the pair volumes for ShadowImage, Copy-On-Write (COW), and True Copy (Sync). Protection Manager commands do not support operation of True Copy (Async), Universal Replicator, Cross-system Copy or Hitachi Hi-Copy paired volumes. MU Numbers When using True Copy, do not enter an MU number in the MU# setting in the CCI definition file (horcm#.conf). If 0 is defined for the MU# setting, volume information for the True Copy pair will not be stored in the dictionary map. When using Universal Replicator, define h0 (h and a generation number) for the MU# setting in the CCI definition file (horcm#.conf). If 0 is defined for MU#, the Universal Replicator information will not be stored in the dictionary map. To backup multiple primary volumes to multiple generations, specify the same dev_group name for all pair volumes that have the same MU#. Primary and Secondary Volumes Import Server When the CCI instance for the primary volume and the secondary volume are defined on the different servers, make sure that you start the CCI instance for the secondary volume in advance. You cannot use a server within an Exchange cluster as an Import server. Instead, use a backup server that backs up Exchange data from SVOL to TAPE. 8 Chapter 2 Reviewing Prerequisite Tasks for VSS Backup
2.1.3 VSS Hardware Provider Requirements Raid Manager Shadow Copy Provider must be installed on the Exchange server and on the Import (Backup) server. Its installation path should be the Windows system drive. When using the VSS backup function, make sure that the storage subsystem model, the CCI version, and the microcode version are appropriate to that function. 2.1.4 Microsoft Exchange Server Requirements Table 2.3 lists the hardware and server requirements. Table 2.3 Requirement List of Hardware and Server Requirements Details Microsoft Exchange Microsoft Exchange Server 2003 Standard Edition (Service Pack 1) Microsoft Exchange Server 2003 Enterprise Edition (Service Pack 1) Microsoft Exchange Server 2003 Standard Edition (Service Pack 2) Microsoft Exchange Server 2003 Enterprise Edition (Service Pack 2) Microsoft Exchange Server 2007 Standard Edition Microsoft Exchange Server 2007 Enterprise Edition Note: For Exchange 2003 Service Pack 1, you need to apply Microsoft hotfix 892514. For Exchange 2007, you need to apply Microsoft hotfix 898790, 918980, and 922931. The following files under the target Exchange Storage Group are backed up by Protection Manager for Exchange Server: Data files: *.edb, *.stm (Only for Exchange 2003) Transaction log files: *.log Checkpoint files: *.chk Files The files to be backed up must all be placed on a RAID volume defined and created as a CCI copy pair. Transaction log files (*.log) and data files (*.edb and *.stm) must be located on a separate volume. When using VSS backup, data files (*.edb and *.stm) and checkpoint files (*.chk) cannot exist together in a same volume. When using Information Store (DB) restore granularity with Roll-Forward, the Information Store data files (*.edb and *.stm) must be located on the separate volumes from other data files. Backup/Restore/Repair Backup and restore operations using VSS cannot be performed for storage groups that use the circulation log. The Recovery Storage Group for Exchange Server cannot be backed up. When performing VSS backup, the Information Store according to target Storage Group must all be in mounted status. However, the Information Store can be restored even if it is in dismounted status. When repairing Information store or performing defragmentation with ESEUTIL (ESEUTIL /p or ESEUTIL /d), change the name of database and backup images made with Protection Manager. Otherwise, these operations cannot be restored or recovered. Always backup the Exchange database immediately after performing the ESEUTIL command. Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 9
2.1.5 Other Requirements When performing backup or restoration on the Microsoft Exchange server, make sure that the secondary volumes involved are not mounted to any server in advance. Protection Manager Service must be started on the Exchange server and Import server prior to running a backup or restore. Update the dictionary map file (drmexgdisplay refresh) before performing backup in any of the following situations concerning Exchange Server objects, File Systems, and/or CCI definition files (horcm#.conf): A new Exchange Storage Group or Information Store was added. A new file system to do with target Exchange Server was mounted. A file system related to the target Exchange Server was unmounted. CCI definition file (horcm#.conf) concerning backup target Exchange Server was changed, such as the adding or deleting of a CCI copy pair. If VERITAS Backup Exec Advanced Open File Option is installed on either the Exchange server or the backup server, please apply patch VSP1.04. If VSS backup is aborted by system failure etc, the Read-Only and Hidden attributes may be left in the backup target volume. If these attributes are left, the drive name is not assigned and Exchange Server will not correctly operate at the system startup. To correct the issue, clear the attributes according to Microsoft technical Article 840781. Note: Microsoft technical article 840781 is also required to apply the hotfix described in Microsoft technical article 831112. When using Windows Server 2003 with Service Pack 1 and the firewall function provided by the operating system, note the following points: You must specify firewall settings for the communication ports for CCI. To use VSS, you must execute the following command on the backup server to specify the firewall settings for the VSS import server: <Protection-Manager-installation-folder>\bin\util\drmaddfwlist.bat To execute the extended commands for FTP transmission (EX_DRM_FTP_PUT and EX_DRM_FTP_PUT), you must specify firewall settings for the FTP Publishing Service. For details, see Port requirements for Microsoft Windows server system (http://support.microsoft.com/default.aspx?scid=kb;en-us;832017). If Protection Manager takes multiple generations of backup with VSS, or configured in MSCS, these SVOLs must be hidden from the operating system. Because the SVOLs taken by arraybased replication are exact replicas of PVOLs and have the same disk signature, the operating system tends to overwrite when multiple SVOLs are presented. Restoring the SVOL results in MSCS failing to bring the PVOL back online, because MSCS perceives that it is not available. Selecting the Dynamic recognition of secondary volume option on Setup GUI prevents this from happening. For details of the procedure, see sections 4.2 and 4.3. 10 Chapter 2 Reviewing Prerequisite Tasks for VSS Backup
2.2 Reviewing the Support Matrices 2.2.1 VSS versus Subsystem and Copy Functions The following table lists the supported storage subsystems and copy functions. Table 2.4 Storage Subsystems and Copy Functions Matrix UR TC (Async)/TCE TC (Sync) SI COW USP/NSC Not Supported Not Supported Supported Supported Supported AMS Not Applicable Not Supported Supported Supported Supported WMS Not Applicable Not Applicable Supported Supported Supported 9900V Not Applicable Not Supported Supported Supported Not Applicable 9500V Not Applicable Not Applicable Supported Supported Supported 2.2.2 VSS versus Volume Manager and Clusters The following table lists the supported volume managers and clusters. Table 2.5 Volume Manager and Cluster Support Matrix Shadow Image / Quick Shadow True Copy (Sync) Notes LDM Basic Disk Dynamic Disk No Cluster Supported Supported MSCS Supported Supported VCS Requires volumes to be managed by VxVM No Cluster Protection Manager does NOT support Dynamic Disk MSCS MSCS does NOT support Dynamic Disk VCS Requires volumes to be managed by VxVM VxVM Basic Disk Dynamic Disk No Cluster MSCS VCS No Cluster MSCS VxVM (VERITAS Storage Foundation for Windows 4.3 MP1) does NOT support third party VSS hardware providers, including HDS. VCS Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 11
2.2.3 Protection Manager Functions and Prerequisite Versions The following tables list the supported Protection Manager functions, and the prerequisite versions of RM Shadow Copy Provider, CCI (RAID Manager), and Array microcode. Table 2.6 Support Matrix for Array Microcode USP / NSC or 9970V / 9980V Related Version VSS function of RM Shadow CCI Array Microcode Protection Manager Copy Provider (RAID Manager) 9970V / 9980V USP / NSC USP V / USP VM 01-02-03/01 01-15-03/03 21-10-01 50-00-26 for ICS version 01-02-03/03 01-16-03/03 Undelivered 50-03-01 for 2 s GA 01-02-03/05 01-16-03/06 21-13-04-00 Undelivered 01-02-03/05 01-16-03/06 Undelivered 50-03-89 01-02-03/06 01-18-03/06 Undelivered 50-05-06-00/00 Protection Manager 3.51 Exchange single-generation Protection Manager 4.0 Exchange Multiple-generation NTFS Multiple-generation Remote Copy (TC-sync) Protection Manager 4.3 Windows 2003 SP1 Protection Manager 4.3.1 Exchange Multiple-generation with Copy-on-write snapshot 01-02-03/07 01-19-03/04 21-14-28 50-08-05 Protection Manager 5.7 Exchange Server 2007 01-03-03/XX 01-20-03/XX 60-01-30/XX Protection Manager 5.8 01-03-03/XX 01-20-03/XX 60-01-6X/XX 12 Chapter 2 Reviewing Prerequisite Tasks for VSS Backup
Table 2.7 Support Matrix for Array Microcode AMS / WMS or 9570V (9580V) Related Version RM Shadow Copy Provider CCI (RAID Manager) Array Microcode 9570V (9580V) AMS / WMS VSS function of Protection Manager 01-02-03/01 01-15-03/03 065A(165A) None Protection Manager 3.51 Exchange single-generation 01-02-03/02 01-15-03/04 Undelivered None 01-02-03/03 01-16-03/03 Undelivered None 01-02-03/04 01-16-03/05 None None 01-02-03/05 01-16-03/06 065A/R(165A/R) None 01-02-03/05 01-16-03/06 Undelivered 0712/A Protection Manager 4.0 Exchange Multiple-generation with QuickShadow NTFS Multiple-generation with QuickShadow Remote Copy (TC-sync) Protection Manager 4.3 Windows 2003 SP1 01-02-03/07 01-19-03/04 Undelivered 0750/A Exchange Multiple-generation with ShadowImage NTFS Multiple-generation with ShadowImage Protection Manager 5.5 01-02-03/07 01-19-03/04 065E(165E) 0750A Protection Manager 5.7 Exchange Server 2007 Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 13
14 Chapter 2 Reviewing Prerequisite Tasks for VSS Backup
Chapter 3 Configuring the Microsoft Exchange Database for VSS Backup This chapter explains the procedures for configuring the Microsoft Exchange database. Preparing the Microsoft Exchange Database for VSS Backup (section 3.1) Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 15
3.1 Preparing the Microsoft Exchange Database for VSS Backup The following table outlines the sequence of volume configuration and installation steps that are required before Protection Manager can be installed and configured. Table 3.1 Sequence of Volume Configuration and Installation Steps Configuring the Storage Volume Step Procedure Server 1 Create the Logical Units and CMD 2 Assign the Logical Units and CMD Configuring the Server Volume 3 Map LUN to the each server Exchange Import 4 Format and Mount the volumes Exchange Setting up CCI (RAID Manager) 5 Install the CCI (RAID Manager) Exchange Import 6 Define the CCI copy pairs Exchange Import 7 Create the CCI copy pairs Exchange Setting up RM Shadow Copy Provider 8 Install the RM Shadow Copy Provider Exchange Import 3.1.1 Configuring the Storage Volume When configuring the storage volume, create the Logical Unit (LU) for the primary volume (PVOL), secondary volume (SVOL), and command device (CMD), then assign to the Exchange and Import (Backup) servers. For detailed instructions, please refer to the appropriate Storage Navigator Modular or Storage Navigator product manuals. 16 Chapter 3 Configuring the Microsoft Exchange Database for VSS Backup
3.1.2 Configuring the Server Volume This section describes LUN mapping on both the Exchange server and Import server, using the Emulex Configuration Tool (elxcfg) as an example of an HBA application. The following procedure must be performed on both the Exchange server (PVOL) and Import (Backup) server (SVOL). To configure the server volume: 1. Map the target LUN to each server: a) Start the Emulex Configuration Tool (elxcfg). b) Select the target World Wide Port Name, then click the Lun Map button. c) When the new dialog displays, click the Add button. d) Select the target LUN, then click the OK button. e) Click the Done button. From the File menu, select Apply, then Exit to close the application. f) Start the Disk Management tool, then select Rescan Disks to recognize the new LUN. Verify that Windows recognizes the new LUN. 2. Initialize the volumes: a) Right-click the Not Initialized disk and select Initialize Disk. b) Select one or more disks to be initialized, then click the OK button. 3. Format and mount the volumes: a) Right-click the target disk and select New Partition. b) Within the Wizard, click the Next button. c) Select the drive letter to be assigned, then click the Next button. d) Select any necessary format options, then click the Next button. e) Confirm the format options, then click the Finish button. Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 17
3.1.3 Setting up CCI (RAID Manager) To set up CCI: 1. Install CCI on both the Microsoft Exchange server and the Import (Backup) server: a) Run the installation file, Setup.exe. b) Click the Next button in the welcome dialog box. c) Click the Next button in the Attention dialog box. d) Select the installation folder, then click the Next button. e) Click the Finish button. 2. Optional: Check the version of CCI by using raidqry command. Note: If you either create the horcm#.conf file by yourself, or if you use mkconf.exe to create this file, you can skip the following procedure (steps 3 12). For information about using the mkconf.exe command, see the CCI (RAID Manager) User and Reference Guide. C:\HORCM\Tool>mkconf Usage : mkconf -g[g] <group> Specify the dev_group for a configuration file. If not specified, 'VG' will be used as default. [-m <mu#> ] Specify the mirror descriptor for BC(MRCF) volume. Specify the mirror descriptor as '-m h1' for UR volume. [-i <inst#>] CA(HORC) volume dose not specify the mirror descriptor. Specify the instance number for HORCM. No running HORCM instance must be specified. [-s <service>] Specify the service name for a configuration file. If not specified, '52323' will be used as default. [-c <drive#>] Specify the drive# in order to discover the CMDDEVs. If not specified, '$PhysicalDrive' will be used as default. If '-a' option is specified, this option is invalid. [-a] Example: type dev_file mkconf -g dev_group -i 9 [-m 0] [-a] echo hd10-20 mkconf -g dev_group -i 9 [-m 0] [-a] Specify an addition of the group for a configuration file. echo $Phys mkconf -g dev_group -i 9 [-m 0] [-a] $variable specifies as follows. $LETALL -> All of the Drive Letter $Phys -> All of the Physical Drives $Volume -> All of the LDM Volumes for Windows2000/2003 Note: The following procedure (steps 3-12) assumes creation of horcm0.conf on the Exchange server, and horcm1.conf on the backup server. If you want to create HORCM definition file, replace the number with your preferred in the following procedure. 3. Define copy pairs using CCI: On the Microsoft Exchange server, find the CMD (Command Device) for the target storage subsystem. C:\HORCM\etc>inqraid $Phys -sort CM HORCM_CMD #dev_name dev_name dev_name #UnitID 0 (Serial# 116) \\.\PhysicalDrive21 #UnitID 1 (Serial# 5368) \\.\PhysicalDrive11 18 Chapter 3 Configuring the Microsoft Exchange Database for VSS Backup
#UnitID 2 (Serial# 55014) \\.\PhysicalDrive20 C:\HORCM\etc> 4. Create the temporary HORCM definition file (in this case, horcm0.conf ). Only define the CMD and the arbitrary port number. HORCM_MON #ip_address service poll(10ms) timeout(10ms) localhost 50000 1000 3000 HORCM_CMD #dev_name dev_name dev_name \\.\PhysicalDrive11 HORCM_DEV #dev_group dev_name port# TargetID LU# MU# HORCM_INST #dev_group ip_address service 5. Start up the temporary HORCM instance: Run the horcmstart command and specify the temporary HORCM instance number. E:\HORCM\etc>horcmstart 0 starting HORCM inst 0 HORCM inst 0 starts successfully. 6. Specify the temporary HORCM instance number to HORCMINST variable, then activate the HORCC_MRCF variable. C:\HORCM\etc>set HORCMINST=0 C:\HORCM\etc>set HORCC_MRCF=1 7. Check the RAID disks connected to the Microsoft Exchange server: Run the raidscan command with the -find option. C:\HORCM\etc>raidscan pi $Phys -find -CLI DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID Harddisk20 - - CL2-A - - 5014 55 OPEN-3-CM Harddisk21 - - CL2-A - - 116 88 DF600F-CM Harddisk4 0 F CL2-C 1 4 5368 4 DF600F Harddisk5 0 F CL2-C 1 5 5368 5 DF600F Harddisk6 0 F CL2-C 1 6 5368 6 DF600F Harddisk7 0 F CL2-C 1 7 5368 7 DF600F Harddisk11 0 F CL2-C 1 20 5368 20 DF600F-CM Harddisk12 0 F CL2-C 1 21 5368 21 DF600F Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 19
8. Define the name of dev_group and dev_name and select the target disk by specifying the port#, TargetID, and LU# in the HORCM_DEV entry. HORCM_MON #ip_address service poll(10ms) timeout(10ms) localhost 50000 1000 3000 HORCM_CMD #dev_name dev_name dev_name \\.\PhysicalDrive11 HORCM_DEV #dev_group dev_name port# TargetID LU# MU# GR01 vol01 CL2-C 1 4 0 GR01 vol02 CL2-C 1 5 0 HORCM_INST #dev_group ip_address service GR01 xx.xx.xxx.xx 50000 9. Restart the HORCM instance: Run the horcmshutdown and horcmstart commands by specifying the target HORCM instance. C:\HORCM\etc>horcmshutdown 0 inst 0: HORCM Shutdown inst 0!!! C:\HORCM\etc>horcmstart 0 starting HORCM inst 0 10. On the backup server, find the CMD (Command Device), create the temporary HORCM definition file (in this case, horcm1.conf ), and check the RAID disks connected to the backup server (steps 3-7, above). C:\horcm\etc>raidscan -pi $Phys -find -CLI DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID Harddisk5 0 F CL2-C 1 11 5368 11 DF600F Harddisk6 0 F CL2-C 1 12 5368 12 DF600F Harddisk7 0 F CL2-C 1 13 5368 13 DF600F Harddisk8 0 F CL2-C 1 14 5368 14 DF600F Harddisk9 0 F CL2-C 1 15 5368 15 DF600F Harddisk10 0 F CL2-C 1 16 5368 16 DF600F Harddisk11 0 F CL2-C 1 17 5368 17 DF600F Harddisk12 0 F CL2-C 1 32 5368 32 DF600F-CM 11. Define the name of dev_group and dev_name and set the target disk by specifying the port#, TargetID, and the LU# in the HORCM_DEV entry. HORCM_MON #ip_address service poll(10ms) timeout(10ms) localhost 50000 1000 3000 HORCM_CMD #dev_name dev_name dev_name \\.\PhysicalDrive12 HORCM_DEV #dev_group dev_name port# TargetID LU# MU# GR01 vol01 CL2-C 1 11 0 GR01 vol02 CL2-C 1 12 0 HORCM_INST 20 Chapter 3 Configuring the Microsoft Exchange Database for VSS Backup
#dev_group ip_address service GR01 xx.xx.xxx.xx 50000 12. Restart the HORCM instance: Run the horcmshutdown and horcmstart commands by specifying the target HORCM instance. C:\HORCM\etc>horcmshutdown 1 inst 1: HORCM Shutdown inst 1!!! C:\HORCM\etc>horcmstart 1 starting HORCM inst 1 13. Create copy pairs by using CCI: On the Microsoft Exchange server, specify the temporary HORCM instance number to the HORCMINST variable, then activate the HORCC_MRCF variable. C:\HORCM\etc>set HORCMINST=0 C:\HORCM\etc>set HORCC_MRCF=1 14. Create the HORCM copy pair: Run the paircreate command with the -vl and -m noread options, and specify the target HORCM copy pair name. When creating the pair with TrueCopy, -m noread option is not required. C:\HORCM\etc>paircreate g GR01 vl c 15 m noread C:\HORCM\etc> Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 21
3.1.4 Setting up RM Shadow Copy Provider To set up Shadow Copy Provider: 1. Install RM Shadow Copy Provider on both Exchange and Backup server: a) Run the installation file RMVSSPRV.exe located in the folder C:\HORCM\tool. b) Click the Next button in the welcome dialog box. c) Select the installation folder and click the Next button. d) To verify the correct installation, check the existence of RM Shadow Copy Provider by using the service applet of Windows. e) Optional: Check the version of RM Shadow Copy Provider by using the vssadmin command. 22 Chapter 3 Configuring the Microsoft Exchange Database for VSS Backup
Chapter 4 Installing and Setting up Protection Manager This chapter describes how to install and set up Protection Manager. Gathering and Installing the Required Components (section 4.1) Setting up the Microsoft Exchange Server (section 4.2) Setting up the Import (Backup) Server (section 4.3) Setting up the Exchange Verify Tool (section 4.4) Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 23
4.1 Gathering and Installing the Required Components Before you set up the Microsoft Exchange server, the Import (Backup) server and the cluster environment, please ensure that you have completed the following tasks: Install: Exchange server: Install Protection Manager Copy Controller, Protection Manager for Exchange Server module, and the Protection Manager Console module. For instructions, see section 4.2. Import (Backup) server: Install Protection Manager Copy Controller and the Protection Manager Console module. For instructions, see section 4.3. Setup Exchange verification tool: Exchange or Import (Backup) server: The operation required for the setup is depends on the version of Exchange Server. For instructions, see section 4.4. Exchange Server 2003: Copy ESEUTIL files to the specified folder on Import (Backup) server. These files are required to verify the backed up Exchange data. Exchange Server 2007: Install Exchange Management Console on Import (Backup) server. This component is required to verify the backed up Exchange data. Verify: Notes: Import (Backup) server: Run configuration check function to verify the system configuration Exchange server recognizes command device (CMD) and primary volumes (PVOL). The Import (Backup) server recognizes command device (CMD) and secondary volumes (SVOL). Exchange server should not recognize SVOLs and Import server should not recognize PVOLs. Before installing HPtM Console module, you need to install Java Runtime Environment (JRE) 1.4.2 or 1.5. 24 Chapter 4 Installing and Setting up Protection Manager
4.2 Setting up the Microsoft Exchange Server To set up the Exchange server: 1. Install HiCommand Protection Manager Copy Controller: a) Run the installation file Setup.exe. The welcome dialog box displays. b) Click the Next button. The install path selection dialog box displays. c) Select the folder where Setup will install the files, then click the Next button. After the file copy procedure is finished, a completion dialog displays. d) Enter Windows account and password for Protection Manager Service. 2. Install HiCommand Protection Manager for Microsoft Exchange Server: a) Run the Setup.exe file. The welcome dialog box displays. b) Click the Next button. The license registration method dialog box displays. c) Specify the registration option you want to use, then click the Next button. d) Enter the license key, then click the Next button. After the file copy procedure is finished, a completion dialog displays. 3. Install HiCommand Protection Manager Console: a) Run the Setup.exe file. The welcome dialog box displays. b) Click the Next button. The install path selection dialog box displays. c) Select the folder where Setup will install the files, then click the Next button. After the file copy procedure is finished, a completion dialog displays. 4. Setup shared volume for dictionary map files in cluster configuration: If you installed Protection Manager on cluster configuration of Exchange server, following procedure is required to setup shared volume: a) Map a LUN to the Exchange server, then initialize and format the volume. b) Add the volume to the Exchange cluster group as a physical disk cluster resource (see Figure 4-1). This disk is supposed to store the dictionary map files of HiCommand Protection Manager, which allows Protection Manager to share the object mapping information and the backup information on both of the cluster node. 5. Set up HiCommand Protection Manager: a) Start the Console: From the Start menu, select HiCommand Protection Manager Console, then choose Console. b) Open the GUI Setup window: From the Console, select Tools, then choose Setup. c) Within the Configuration Settings tab [Step 1/9], select Database/File server for the server type, and Exchange for the backup object. Depends on the Exchange server configuration, select Non Cluster Configuration or Cluster Configuration for the cluster configuration. Afterward, the total procedure that you should specify is displayed in the Setup Steps area. For an example for a cluster configuration, see Figure 4-2. Click the Next button. Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 25
d) Optional: Within the Operation Setup tab [Step 2/9], set the retry parameters, the log output level and the number of trace log files. For more detailed information, refer to Chapter 5, Setting Up an Environment for Protection Manager Using Setup GUI in the HiCommand Protection Manager User s Guide. Click the Next button. If the Exchange servers are cluster configuration, enter the virtual server name in the Dictionary map file path, then click the Browse... button. Select the location on the shared disk in which the dictionary map files are stored, then click the Add button. Select the new entry, then click the Create button to create the dictionary map files. (see Figure 4-3) e) Within the RAID Manager Linkage tab [Step 3/9], check and set the CCI instance number and its install path for HORCMINST, HORCMINST_AUX, and INSTALLPATH entries (see Figure 4-4). Afterward, click the Next button. Field definitions: HORCMINST Specify the CCI instance number managing the PVOLs. (in this case, 0 ) HORCMINST_AUX Specify the CCI instance number managing the SVOLs. (in this case, - ) Selecting Pair split on the Pair Status when Backup Fail is recommended so that Protection Manager split the pair even if the backup has failed. If you configured multiple generations of SVOL in clustered Exchange server, select the Dynamic recognition of secondary volume to make HPtM hide the SVOL from the operating system. f) If needed, set the retry parameters for turning the performance within the RAID Manager Operation tab [Step 4/9]. For details, refer to Chapter 5, Setting Up an Environment for Protection Manager Using Setup GUI in the HiCommand Protection Manager User s Guide. Click the Next button. g) Within the Cluster Configuration tab [Step 5/9], select the cluster product name (Microsoft Cluster Service (MSCS) or VERITAS Cluster Server (VCS)). For details, refer to Chapter 5, Setting Up an Environment for Protection Manager Using Setup GUI in the HiCommand Protection Manager User s Guide. Click the Next button. h) Within the VSS Definition tab [Step 6/9], set the name of the backup (import) server that verifies the backed up Exchange data after creating a VSS snapshot, then click the Next button. i) Within the VSS Environment tab [Step 7/9], select the generation type of the backup environment (Multiple generation or Single generation. See Figure 4-6). If you select Single generation, specify appropriate number on the RAID Manager instance number for primary volume. (in this case, 0 ), and on the Copy group mirror unit number (in this case, 0 ). Then click the Next button. j) Within the Protection Manager Service tab [Step 8/9], specify the TCP port number for Protection Manager Service. This number has to be consistent between Exchange server and backup (import) server (see Figure 4-7). k) Within the Update Dictionary Map tab [Step 9/9], check the Exchange box on backup object, then click the Save button (see Figure 4-8). If you configure cluster of Exchange server, also select the virtual server name specified on Operation Setup tab [Step 2/9]. Protection Manager starts to collect the object mapping (including Exchange objects, File System and horcm replication information) by using the drmexgdisplay.exe refresh command. 26 Chapter 4 Installing and Setting up Protection Manager
l) Click the Cancel button to exit the Setup GUI. If the interface asks you to restart the operating system with the dialog shown on Figure 4-9, do so. Figure 4-1 Adding a Physical Disk to Exchange Cluster Group Figure 4-2 Configuration Settings: Step 1/9 Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 27
Figure 4-3 Operation Setup: Step 2/9 Figure 4-4 RAID Manager Linkage: Step 3/9 28 Chapter 4 Installing and Setting up Protection Manager
Figure 4-5 VSS Definition: Step 6/9 Figure 4-6 VSS Environment: Step 7/9 Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 29
Figure 4-7 Protection Manager Service: Step 8/9 Figure 4-8 Update Dictionary Map: Step 9/9 30 Chapter 4 Installing and Setting up Protection Manager
Figure 4-9 KAVX16308-W Warning dialog Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 31
4.3 Setting up the Import (Backup) Server To set up the Import (Backup) server: 1. Install HiCommand Protection Manager Copy Controller: a) Run the installation file Setup.exe. The welcome dialog box displays. b) Click the Next button. The install path selection dialog box displays. c) Select the folder where Setup will install files, then click the Next button. The setup type selection dialog displays. d) Click the Next button. After the file copy procedure is finished, a completion dialog displays. e) Enter Windows account and password for Protection Manager Service. 2. Install HiCommand Protection Manager Console: a) Run the installation file Setup.exe. The welcome dialog box displays. b) Click the Next button. The install path selection dialog box displays. c) Select the folder where Setup will install files, then click the Next button. The setup type selection dialog displays. d) Click the Next button. After the file copy procedure is finished, a completion dialog displays. 3. Set up HiCommand Protection Manager: a) Start the Console: From the Start menu, select HiCommand Protection Manager Console, then choose Console. b) Open the GUI Setup window: From the Console, select Tools, then choose Setup. c) Within the Configuration Settings tab [Step 1/9], select Backup server for the server type, and Non Cluster Configuration for the cluster configuration. Selecting the backup object is not required on the Import (Backup) server. Afterward, the total procedure that you should specify is displayed in the Setup Steps area. For an example for a cluster configuration, see Figure 4-10. Click the Next button. d) Optional: Within the Operation Setup tab [Step 2/9], set the retry parameters, the log output level and the number of trace log files. For more detailed information, refer to Chapter 5, Setting Up an Environment for Protection Manager Using Setup GUI in the HiCommand Protection Manager User s Guide. Click the Next button. e) Within the RAID Manager Linkage tab [Step 3/9], check and set the CCI instance number and its install path for HORCMINST, HORCMINST_AUX, and INSTALLPATH entries (see Figure 4-11). Afterward, click the Next button. Field definitions: HORCMINST Specify the CCI instance number managing the SVOLs. (in this case, 1 ) HORCMINST_AUX Specify the CCI instance number managing the PVOLs. (in this case, - ) 32 Chapter 4 Installing and Setting up Protection Manager
Selecting Pair split on the Pair Status when Backup Fail is recommended so that Protection Manager splits the pair even if the backup has failed. If you configured multiple generations of SVOL in clustered Exchange server, select the Dynamic recognition of secondary volume to make HPtM hide the SVOL from the operating system. f) If needed, set the retry parameters for turning the performance within the RAID Manager Operation tab [Step 4/9]. For details, refer to Chapter 5, Setting Up an Environment for Protection Manager Using Setup GUI in the HiCommand Protection Manager User s Guide. Click the Next button. g) Within the VSS Environment tab [Step 5/9], select the generation type of the backup environment (Multiple generation or Single generation). Additionally, specify the CCI instance number for secondary volume. (in this case, 1 ) Click the Next button. h) Within the Protection Manager Service tab [Step 6/9], you can change the TCP port of the communication between the Microsoft Exchange server and the backup (import) server by setting the specified port number in the TCP port number for Protection Manager Service area. Click the Next button. i) If you do not back up Exchange data from SVOL to TAPE by VERITAS Net Backup or VERITAS Backup Exec, the steps within the Backup Linkage tab [Step 7/9] and the Tape Backup tab [Step 8/9] are unnecessary. For details, refer to Chapter 5, Setting Up an Environment for Protection Manager Using Setup GUI in the HiCommand Protection Manager User s Guide. Click the Next button. j) Skip Update Dictionary Map File [Step/9/9]. Protection Manager doesn t have object mapping on the backup server, so this step is unnecessary. k) Click the Cancel button to exit the Setup GUI. If the interface asks you to restart the operating system with the dialog shown on Figure 4-9, do so. l) If you configured multiple generations of SVOL in clustered Exchange server, launch a Command Prompt, then execute the drmdevctl command with -detach option to conceal the SVOLs on the Backup Server. The command allows Protection Manager to execute the raidvchkset command with the -vg idb option, then rescan the disk and volume with diskpart command. C:\HORCM\etc>drmdevctl -detach KAVX0001-I The drmdevctl command will now start. KAVX0232-I Hid sqlsia,sqldataa. KAVX0232-I Hid sqlsia,sqltloga. KAVX0232-I Hid sqlsib,sqldatab. KAVX0232-I Hid sqlsib,sqltlogb. KAVX0232-I Hid sqlsi2,sqlsystem. KAVX0232-I Hid sqlsi2,sqluser. KAVX0234-I Rerecognizes the physical volume. KAVX0235-I Rerecognized the physical volume. KAVX0002-I The drmdevctl command will now end. Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 33
Figure 4-10 Configuration Settings: Step 1/9 Figure 4-11 RAID Manager Linkage: Step3/9 34 Chapter 4 Installing and Setting up Protection Manager
Figure 4-12 KAVX16308-W Warning dialog Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 35
4.4 Setting up the Exchange Verify Tool The operation required for the setup is depends on the version of Exchange Server. 4.4.1 Setting up for Exchange Server 2003 Copy following files located in the Exchange-Server-install-path\bin folder on the Microsoft Exchange server, then paste all four files into the Protection-Manager-install-path\bin\util folder on the Import (Backup) server: ESEUTIL.exe ESE.dll EXCHMEM.dll EXOSAL.dll 4.4.2 Setting up for Exchange Server 2007 Run the installation file of Exchange Server 2007 on the Import (Backup) server, and select Exchange Management Console for the installation. Once the component is installed on the Import server, Protection Manager utilizes the API on the component to verify the Exchange data. 36 Chapter 4 Installing and Setting up Protection Manager
Running HPtM Configuration Checker on the Import (Backup) Server Protection Manager provides a configuration check function for verifying the system configuration and ensuring that it is appropriate for proper functioning of Protection Manager. Whenever a new system using Protection Manager is built or an existing system configuration is modified, the configuration check function should be used to verify the system configuration. 1. Executing the Configuration Check Function To execute the configuration check function: a) Launch Protection Manager Console on the Import (Backup) server. b) Select Tools, and then Check Configuration to launch the Input Servers dialog box (see Figure 4-13). c) In the DB Servers list box, register either the host name or IP address for the Exchange server to be verified. If the Exchange servers are in cluster configuration, register all the nodes of Exchange servers. The host name or IP address for virtual server can not be registered. To add a server, perform one of the following operations: Right-click the position in the list box where a line is to be added, and choose Insert Row from the pop-up menu. Select a position in the list box where a line is to be added, and press the Insert key. Select the last line in the list box, and press the Tab key. To delete a server, perform one of the following operations: In the list box, right-click the line to be deleted, and select Delete Row(s) from the pop-up menu. In the list box, select the line to be deleted, and press the Delete key. d) In the BK Servers list box, register the host name or IP address for the backup server to be verified. See Step 3 for the registration method. e) In Backup Object, select the Exchange server and Using VSS check box. f) Click the Check button to start verification. The check results are displayed in the Check Results dialog box. 2. Reviewing the Check Results To review the check results of the configuration check function: a) Review the contents output in the Check Results dialog box (see Figure 4-14). b) Identify items with error or warning result, and check the messages. c) Double click the item and review the information with the Result dialog box (see Figure 4-15), then fix the problem according to the information displayed on Action field. d) Click the Close button to closes the Result dialog box. e) Repeat Steps from b) to d) for all the items with error or warning. f) Click the Close button to close the Check Results dialog box. Then execute the configuration check function again to ensure the error has fixed. Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 37
Figure 4-13 Input Servers Dialog Box Figure 4-14 Check Results Dialog Box 38 Chapter 4 Installing and Setting up Protection Manager
Figure 4-15 Result Dialog Box Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 39
40 Chapter 4 Installing and Setting up Protection Manager
Chapter 5 Troubleshooting This chapter explains how to handle any problems that may occur while you are working with VSS Backup. Troubleshooting VSS Backup Errors (section 5.1) Calling the Hitachi Data Systems Support Center (section 5.2) Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 41
5.1 Troubleshooting VSS Backup Errors The following table lists the common errors you may encounter during VSS backup, and describes the steps to troubleshoot those issues. For any troubleshooting case that is not listed in this table, please refer to the actual product manuals. For errors that cannot be resolved, please see section 5.2 for information about contacting the Hitachi Data Systems Support Center. Table 5.1 Error Causes and Troubleshooting Steps Issue Cause Verify Troubleshooting Steps drmexgbackup command failed with KAVX5003-E The system environment variables related to RM shadow copy provider or HORCM definition file on the Microsoft Exchange server may be invalid, The Application Event Log of Windows on the Microsoft Exchange server output Warning or Error logs for RMVSSPRV source. Refer to the content of Application Event Log. If this Windows 2003 server was upgraded from Windows 2000 server, VSS function may be unable to work correctly. The Application Event Log of Windows on the Microsoft Exchange server output Error logs for COM+ source. Install Windows 2003 Enterprise Edition (do not perform an upgrade installation). The DLL registration information of VSS may be corrupt. The Application Event Log of Windows on the Microsoft Exchange server output Error logs for VSS source. Execute the following command line to re-register information, C:\> regsvr32 VSS_PS.DLL and then re-install RM shadow copy provider. drmexgbackup command failed with KAVX5033-E The system environment variables related to RM shadow copy provider or HORCM definition file on the Backup server may be invalid, The Application Event Log of Windows on the Backup server output Warning or Error logs for RMVSSPRV source. Refer to the content of Application Event Log. If this Windows 2003 server was upgraded from Windows 2000 server, VSS function may be unable to work correctly. The Application Event Log of Windows on the Backup server output Error logs for COM+ source. Install Windows 2003 Enterprise Edition newly. The DLL registration information of VSS may be corrupt. The Application Event Log of Windows on the Backup server output Error logs for VSS source. Execute the following command line to re-register information, C:\> regsvr32 VSS_PS.DLL, and then re-install RM shadow copy provider. The CCI instance number isn t described in HORCMINST of DEFAULT.dat file on the Backup server as same as the system environment variable VSHTCHORCMINST_REMO TE. Other than those above Set the CCI instance number that manages SVOLs (as same as VSHTCHORCM_REMOTE) to HORCMINST of DEFAULT.dat file. 42 Chapter 5 Troubleshooting
Issue Cause Verify Troubleshooting Steps The following system environment variables may be set on the Backup server: HORCMINST HORCC_MRCF HORCMPERM Unset these system environment variables on the Backup server, and then restart OS. drmexgbackup command failed with KAVX5023-E and DRM-10434 The HBA driver may not support VSS function. The Application Event Log of Windows output the following error log. Source: VSS Event ID: 12289 Update the HBA driver that supports VSS function. Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 43
5.2 Calling the Hitachi Data Systems Support Center If you need to call the Hitachi Data Systems Support Center, make sure to provide as much information about the problem as possible, as outlined in this chapter. The Hitachi Data Systems customer support staff is available 24 hours a day, seven days a week. If you need technical support, please call: United States: (800) 446-0744 Outside the United States: (858) 547-4526 44 Chapter 5 Troubleshooting
Acronyms and Abbreviations API BMP CCI CMD DAMP DLL DNS FQDN GUI HBA I/O JRE LAN LDEV LDM LU LUN MB MU OS PVOL RAID SAN SVOL TC UDP VSS application programming interface bitmap command control interface command device disk array management program dynamic linking library domain name system fully qualified domain name graphical user interface Host bus adapter input/output Java Runtime Environment local area network logical device logical disk manager logical unit logical unit number megabytes mirror unit operating system primary volume redundant array of independent disks storage area network secondary volume TrueCopy user datagram protocol volume shadow copy service Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 45
46 Acronyms and Abbreviations
Index CCI (RAID Manager) setup, 18 configuring server volume, 17 storage volume, 16 Exchange Verify tool setup, 36 Import (Backup) server setup, 32 Microsoft Exchange database preparing for VSS backup, 16 Microsoft Exchange Server setup, 25 Protection Manager prerequisites for install, 24 requirements Microsoft Exchange Server, 9 miscellaneous, 10 VSS hardware provider, 9 requirements, CCI, 8 requirements, hardware and software, 7 RM Shadow Copy Provider setup, 22 storage subsystems, supported, 11 troubleshooting, 42 volume managers and clusters, supported, 11 VSS backup overview, 2 process flow, 3 role of import server, 6 Hitachi Protection Manager VSS Backup of Microsoft Exchange Server Getting Started Guide 47