Bureau Veritas Consumer Product Services GmbH



Similar documents
Copy of marking plate: Copia della piastra della marcatura: Display front:

Page 2 of 59. Copy of marking plate: Copia della piastra della marcatura:

Consumer Products Services Germany GmbH Türkheim Germany

analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors

Serie ET / ET Series

TEST REPORT RAPPORTO DI PROVA TEST ON TYRES ACCORDING TO CLIENT PROCEDURE

RAPPORTO DI PROVA TEST REPORT

serie FX3 e FX4 - FX3 and FX4 series

Alimentatori LED LED drivers

INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag Product selection. Caratteristiche tecniche pag Tecnical data

SERIE FX3 e FX4 - FX3 and FX4 SERIES

RAPPORTO DI PROVA / TEST REPORT

ELENCO PROVE ACCREDITATE - CATEGORIA: 0

TEST REPORT RAPPORTO DI PROVA EMC tests on

MINI CONTATTORI / MINI CONTACTORS

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

MADE IN ITALY. Sistemi di connessione per fotovoltaico Connection systems for photovoltaic. TÜV certification EN 50521:2008 SC3

Test Report No.: G59/3 TOTEM 10 / 20

PRODUCTS SERIES OL OP 50 OM 50 OL 60 PL 200 GL/TL 500 OP 100 OM 80 OL 80 PL 250 GL/TL 600 OL 150 PL 400

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

RAPPORTO DI PROVA TEST REPORT. Titolo (Title): EMC Immunity test and measure of the harmonic components and Flicker on. SP40 plus

RELAYS Solar Energy Systems

CATALOGO LED / LED CATALOGUE

E-STOP relays, safety gate monitors

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Motori elettrici corrente continua. DC motors MCC

RY2 miniature industrial relays

THERMAL ENERGY METER MC 108/ET

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

CONTATORE ENEL MONOFASE/TRIFASE CONTATORE TRIFASE DI ENERGIA ELETTRICA FIGURA 1: SCHEMA DI INSTALLAZIONE

13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Anelli Rings (1) (1) (2) (2) (3) TIPI - TYPES CARATTERISTICHE FEATURES. 1mm 3 24Vdc 10 30Vdc 10 30Vdc 10% 10% 200 ma.

Safety and function tester series 1800

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ELENCO PROVE ACCREDITATE - CATEGORIA: 0

DESCRIPTION DESCRIZIONE

C Series. 16(5)A at 250V A.C 50Hz. 3A at 30V D.C. L/R=5ms 10 milioni di operazioni a 1 Hz / million operations at 1Hz 1250Vrms at 50Hz

FX3 - FX4 SERIES. SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE FX FX series - photoelectric sensors FOR OPTICAL FIBRES FX3/0P-0A

NX 16 SR / X A N - A 0 00

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Safety Manual BT50(T) Safety relay / Expansion relay

38 Series - Relay interface modules A

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

T Substation Maintenance and Commissioning Test Equipment

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

B12 INTERRUTTORI DI PROSSIMITA INDUTTIVI PUSH-PULL STANDARD SERIE SERIES INDUCTIVE PROXIMITY SWITCHES PUSH-PULL STANDARD B12

vacon 8000 solar inverter a driving force in solar energy

Sensori induttivi conformi alle norme DIN CENELEC EN EN NAMUR (3) CARATTERISTICHE FEATURES. 2mm 3 24 Vdc 10%

Features. Symbol JEDEC TO-220AB

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

38 Series - Relay interface modules A

SUNNY TRIPOWER 5000TL 12000TL

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

PS3 CONTROL UNIT PS3 CONTROL UNIT. for 4-wire ribbon switches, edges and mats. Instruction use and maintenance READ BEFORE ANY INSTALLATION

C01 INTERRUTTORI DI PROSSIMITA INDUTTIVI AMPLIFICATI A DUE FILI IN CORRENTE ALTERNATA SERIE SERIES

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

ELENCO PROVE ACCREDITATE - CATEGORIA: 0

BB800 Off-Grid Solar System

Charge Controller CC611/CC612 Preliminary datasheet

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Current and voltage measuring relays

E E V R E - R S - O S L O A L R

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

E-STOP relays, safety gate monitors

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

GIBITRE INSTRUMENTS S.R.L. VIA MEUCCI CURNO BG ITALY INTERNAL TENSOR CHECK. GIBITRE Instruments TENSOR CHECK COMPACT-PC

3-Phase Energy meter with serial S-Bus interface

POMPE ROTOMEC. ELETTROPOMPE SOMMERGIBILI Submersible pumps. IMPIEGO - Application. DESCRIZIONE - Description. DATI ELETTRICI - Electric data

Quick Connect. quick - simple - efficient.

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Three-phase monitoring relay CM-PFE

3-phase, bidirectional energy meter

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Electrical Safety Tester

Bare copper complying with CEI EN (CEI 20-29) class 1. Foam PE with HDPE skin. Core colours: green and red

FP2 Relay. The Best Relaytion

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

4 IN 5 OUT MATRIX SWITCHER YUV & Stereo Audio

A Practical Guide to Dielectric Testing

SURGE PROTECTIVE DEVICES

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

PNOZsigma - Base units

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

LED Power. Power Supplies for constant current HI-POWER LEDs 350/700mA Alimentatori per LED in corrente costante HI-POWER 350/700mA 82206/700

Uninterruptible Power System

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DICHIARAZIONE DI PRESTAZIONE DECLARATION OF PERFORMANCE Ai sensi del REGOLAMENTO (UE) N. 305/2011

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MIT510/2, MIT520/2 and MIT1020/2

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

R.C.C.B. s two-pole LEXIC

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

AMDx4 INTERFACE CONTROL PANEL FOR AUTOMATIC SOFTENERS AM/D METER

Transcription:

Specification of the Test Object (Oggetto Del Test) CEI 11-20 (2004-08) e alla norma ENEL DK 5940 Ed. 2.2 (Aprile 2007) Automatic disconnecting facility for photovoltaic installations Rapporto prove numero...: 10TH0045-YURA-DK5940_0 Testato da (nome e firma)...: Frank Hesmer Approvato da (nome e firma)...: Bernd Kreitmeier Data d`emanazione...: 2010-05-19 Testing Laboratory Name... : Nome del laboratorio di certificazione: Bureau Veritas Consumer Product Services GmbH Indirizzo...: Businesspark A96, 86842 Türkheim, Germania Prove effetuate in...: Bureau Veritas E&E Product Services GmbH Indirizzo...: Businesspark A96, 86842 Türkheim, Germania Nome del Richiedente...: Yuraku S.r.l. Indirizzo...: Via Fratelli Rosselli 3/2, 20019 Settimo Milanese, Italia Specifica del test: Standard...: Test in accordo alla norma italiana CEI 11-20 (2004-08) e alla norma ENEL DK 5940 Ed. 2.2 (Aprile 2007) e GUIDA PER LE CONNESSIONI ALLA RETE ELETTRICA DI ENEL DISTRIBUZIONE (2008-12) Tipo di rapporto per il test...: ENEL DK 5940 Ed. 2.2 (Aprile 2007) TRF creatore...: Bureau Veritas Master TRF...: Marzo-2008 Copyright 2007 Bureau Veritas E&E Product Service GmbH, All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the INNOVA Product Service GmbH is acknowledged as copyright owner and source of the material. INNOVA Product Service GmbH takes no responsibility for and will not assume liability for damages resulting from the reader s interpretation of the reproduced material due to its placement and context. Descrizione dell`oggeto del test Marchio...: Solar Inverter Modell e/o referenza...: YUR.POWER I-6000 Numero di serie...: Prototype Versione Firmware.: J1.0 Valore nominale...: Input Voltage -Tensione d entrate: Input Current - Corrente d entrata: Output Voltage - Tensione d uscita: Output current - Corrente d uscita: Output Power - Potenza d uscita: YUR.POWER I6000 100 600V DC, MPPT: 150 600V DC 30A DC 230V AC, 50/60Hz nom./max. 26,1A AC nom./max. 6000W AC

Page 2 of 34 Copy of marking plate: Copia della piastra della marcatura:

Page 3 of 34 History Sheet Storico del foglio Frank Hesmer 2010-05-19 Initial report was written Rev. 0 Address of the manufacturer sites: Indirizzo dello stabilimento di produzione: Powercom Co., Ltd. 8F, NO. 246, Lien Chen Road, Chung Ho City Taipei Hsien, Taiwan, R.O.C.

Page 4 of 34 Particulars: test item vs. test requirements / Dettagli: oggetto del test vs requisti del test Equipment mobility... : mobilità dell'apparecchiatura... : Operating condition... : Modo d operazione... : Mains supply tolerance (%)... : Tolleranza dell alimentatore principale : Class of equipment... : Classe del dispositivo... : Mass of equipment (kg)... : For building-in Continuous Input (Solar): 100-600V DC, MPPT: 150-600V DC Output (mains): 230V AC Class I YUR.POWER I6000 Peso del dispositivo... : 27kg Protection against ingress of water... : Grado di protezione contro l acqua... : Test case verdicts / Risultati dei test Test case does not apply to the test object : Il test non si applica all oggetto del test... : Test item does meet the requirement... : Il test rispetta il requisito... : Test item does not meet the requirement.. : Il test non rispetta il requisito... : IP65 according to IEC 60529 N/A P(ass) F(ail) Test: Date of receipt of test item... : Data di Ricezione del test... : Date(s) of performance of test... : Data(e) di esecuzione del test... : 2010-02-08 2010-03-02 to 2010-03-16

Page 5 of 34 General remarks: The test result presented in this report relate only to the object(s) tested. This report shall not be reproduced, except in full, without the written approval of the applicant. (see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. This Test Report consists of the following documents: 1. Test Report 2. Annex 1 ISO certificate 3. Annex 2 EMC Test Report 4. Annex 3 Datasheet of the relays 5. Annex 4 Pictures of the units 6. Annex 5 Test equipment

Page 6 of 34 General product information: / Informazione generali sul prodotto: The Solar converter converts DC voltage into AC voltage. The input and output are protected by capacitors and varistors to earth. The unit is providing EMC filtering at the input and output towards mains. The unit does not provide galvanic separation from input to output but provides a RCMU and an insulation measurement DC PE. The output is switched off by two independent relays in series to assure, that the output circuit will also operate in case of one error. The whole control system is build up redundant.

Page 7 of 34 TEST SHEET: C4.1 CEI 11-20 V1, 5: Criteria of connection to the public network ( CEI 11-20 V1, 5: Criteri di collegamento alla rete pubblica) C4.1.1 CEI 11-20 V1, 5.1: Production installations in Cat I networks Power Factor (CEI 11-20 V1, 5.1:Funzionamento in parallelo alla rete pubblica di I categoria Fattore di Potenza) Power factor test (Fattore di potenza) Operating conditions: (Condizioni di funzionamento) Grid voltage: (V) Output Power: (%) Power factor: (Factor di potenza) Measurement: (Misurazione) [1] Measurement: (Misurazione) (kvar) Reactive Power: (Potenza reattiva) P Limiting value: (Valore limite) (Kvar) YUR.POWER I6000 230V 100% P N 0,999(c) 0,306 1,0 230V 50% P N 0,996(c) 0,276 1,0 230V 20% P N 0,976(c) 0,269 1,0 Limits of CEI 11-20 V1, Section 5.1 (c) capacitive (i) inductive

Page 8 of 34 8. Protection against DC components in the output current ( 8. Criteri generali di allacciamento) Protection against DC-Injection, I DC <0,5% of I max, within max. 0,1s (Protezione corrente continua, 0,5% della corrente massima, max. 0,1 s) P Grid voltage: (Vac) Idc polarity (Polarita c.c.) Measurement: (Misurazione) (ma) Limiting value: (Valore limite) (ma) Disconnection time (Tempo de intervento) (ms) YUR.POWER I6000 230V + 100* 130 87 230V - 100* 130 77 Limits of DK5940 Ed. 2.2, Allegato AIB 2.3.1.1 * The unit provides an auto-correction of the DC part on the output current. Beyond the capability of the autocorrection the unit detects and disconnects due to high DC current. Diagram of permanent DC-Injection 7000 0,150 6000 0,100 5000 0,050 power (W) 4000 3000 0,000 dc current (A) 2000-0,050 1000-0,100 0-0,150 1 101 201 301 401 501 601 701 801 901 1001 1101 1201 1301 1401 1501 1601 1701 1801 time (500ms cycle) power (W) dc current (A) dc current limit (A) dc current limit (A)

Page 9 of 34 9.4 Automatic protection test results (Protezioni di interfaccia risultati di prova) 9.5 Massima tensione e minima tensione P Condizioni di funzionamento: Protezioni minima tensione Frequenza: 50Hz Protezioni massima tensione Parametro Voltaggio Tempo di intervento (ms) Voltaggio Tempo di intervento (ms) Valore limite 0,8 U N 1,2 U N (184 V AC ) <= 200 (276 V AC ) <= 100 Valore misurato 189,7 Tempo di 195 -> 181V 77 73 92 267 -> 279V 74 84 84 sconnessione 230 -> 181V 87 83 69 230 -> 279V 67 67 85 Tempo di riconnessione >= 5s 34 >= 5s 34 Note: Limits of DK 5940, ED. 2.2 (Aprile 2007), Table 3

Page 10 of 34 Protezioni minima tensione: Protezioni massima tensione:

Page 11 of 34 9.5 Massima frequenza e minima frequenza P Condizioni di funzionamento: Parametro Protezioni minima frequenza Frequenza (Hz) Qualunque livello di potere di uscita Tempo di intervento (ms) Protezioni massima frequenza Frequenza (Hz) Tempo di intervento (ms) voltaggio di 80%U uscita N U N 120%U N 80%U N U N 120%U N Valore limite 49,7 senza ritardo intenzionale 50,3 senza ritardo intenzionale Valore misurato 49,80 49,80 49,80 50,21 50,21 50,21 Tempo di 50,00 50,00 senza ritardo intenzionale senza ritardo intenzionale sconnessione 49,00 51,00 Tempo di >= 5s 34 >= 5s 34 riconnessione Note: Limits of DK 5940, ED. 2.2 (Aprile 2007), Table 2

Page 12 of 34 9.5 Frequency derivative (Rate of Change of Frequency) test (Derivata di frequenza) Frequency derivative protection Frequency variation = + 0,5Hz/s (increasing) (Protezioni derivata di frequenza,, valore d'intervento 50,3Hz) N/A Operating conditions: (Condizioni di funzionamento) Grid voltage: Power: (V) (%) 230V (10% P N ) 230V (50% P N ) 230V (100% P N ) Limits of DK 5940 Ed. 2.2 (Aprile 2007), Table 2 Measurement: (Misurazione) (Hz) Disconnection time: (Tempo di intervento) Measurement: (Misurazione) (ms) Limiting value: (Valore limite) (s) senza ritardo intenzionale

Page 13 of 34 Frequency derivative protection Frequency variation = - 0,5Hz/s (decreasing) (Protezioni derivata di frequenza, valore d'intervento 49,7Hz) N/A Operating conditions: (Condizioni di funzionamento) Grid voltage: Power: (V) (%) 230V (10% P N ) 230V (50% P N ) 230V (100% P N ) Limits of DK 5940 Ed. 2.2 (Aprile 2007), Table 2 Measurement: (Misurazione) (Hz) Disconnection time: (Tempo di intervento) Measurement: (Misurazione) (ms) Limiting value: (Valore limite) (s) senza ritardo intenzionale

Page 14 of 34 2.1.3 Verifiche Auto Test Function ALLEGATO AIB: APPARECCHIATURE DI INTERFACCIA CON LA RETE BT In Working Mode press the button over 5 seconds. The LCD will show Setting. Than the PV inverter will enter Function Setting Mode. Toggle the button afterwards, you will see the setting items in the following order: Contrast Set Language Set Auto Test Set When you see the Auto Test Set, press the button over 5 seconds. The LCD will show Setting then the inverter will start the Auto Test Procedure. The Auto Test Procedure starts with the over voltage from 270V to 229V. After this step the relays are opened. It will be shown OK 229V 0,05S stating that the limit matched the measured value and showing the disconnection time. At the next step the PV inverter will start with under voltage from 190V to 230V. The Relays are opened. The result is shown on the LCD: OK 230V 0,05S. In the following step the test will start with upper and lower frequency check. After each test the relays are opened and the result is shown on the LCD OK 49,9Hz 0,05S (upper frequency) and OK 50Hz 0,05S (lower frequency). The summary result will show on LCD Test Pass. During the Auto Test Procedure the PV inverter will not supply with current into the grid. During the Auto Test Procedure, if user press button over 5 seconds. The LCD will show Escape Auto Test then PV inverter will finish Auto Test Procedure

Page 15 of 34 3.1 Protezione di interfaccia (PIB) Rigidità dielettrica P Location Tensione di prova Breakdown Yes/No AC to PE 2kVac / 2,8kVdc No DC to PE 2kVac / 2,8kVdc No Prova ad impulso P Location Tensione di prova Breakdown Yes/No 1,2/50µs surge impulse Relay RY1 (Song Chuan 512-2kV CM No 841P-1AB) Relay RY1 (Song Chuan 512-1kV DM No 841P-1AB) Misura della resistenza di isolamanti P Location Tensione di prova Limite Resistenza di isolamenti Relay RY1 (Song Chuan 512-500V c.c. 1GOhm >150MOhm 841P-1AB) between input/output contacts Prove di assestamento P Temperatura Umidita relativa Durata 55 C 50% 16h 40 C 93% 4 giorni -10 C --- 10h -10 C -> +40 C --- 3h @ -10 C, 3h @ +40 C Note: No deterioration of the unit. Prove ad apparato funzionante P Temperatura Umidita relativa Durata 55 C 50% 16h 40 C 93% 4 giorni -10 C --- 10h -7 C -> +40 C --- 3h @ -10 C, 3h @ +40 C Note: No deterioration of the unit. Prove di sovraccaricabilità dei circuti voltmetrici di misura P Tensione Durata 130%U N permanente P 200%U N 1s P

Page 16 of 34 Annex 1 ISO certificate

Page 17 of 34

Page 18 of 34

Page 19 of 34 Annex 2 EMC Report (The whole Report is stored by Bureau Veritas E&E Product Services GmbH Tuerkheim)

Page 20 of 34

Page 21 of 34 Annex 3 Datasheet of the relays

Page 22 of 34

Page 23 of 34

Page 24 of 34

Page 25 of 34

Page 26 of 34

Page 27 of 34

Page 28 of 34

Page 29 of 34 Annex 4 Pictures of the unit

Page 30 of 34 Enclosure of YUR.POWER I6000

Page 31 of 34

Page 32 of 34 Inside YUR.POWER I6000

Page 33 of 34 Annex 5 Test Equipment list

Page 34 of 34 Equipment Internal No. Transformer 92 TTH ETR 160 V Manufacturer Type Serial No. Last Calibration Current Clamp 110 Chauvin YPAC12 118609YDV Mai 2009 Arnoux AC Source 323 Chroma 6590 0225 Oscilloscope 324 Yokogawa DL1620 91EB06225 Mai 2008 Power Meter 335 ZES Zimmer LMG 500-3 00940605 Electronic Syst. Sep 2009 Variable 374 Ruhstrat 4Ω 26A Resistor 3-Phasen 446 Statron 5316.1 9507001 Trenntrafo climate chamber 657 WEISS Umwelttechnik WK11-180/40 58226037330010 Jan 2010 Digital Multimeter GmbH 663 GMC-I Gossen- Metrawatt GmbH METRAHit 29S SF4220 Aug 2009 Dielectric tester 730 SPS HA 2201G 04032304 Feb 2010 electronic DC- source 870 Regatron Model T.C.P. 0941CC133 Transducer Powersupply Currenz Transducer 906 SIGNALTEC TPS 907 Danfysik Ultrstab 867 37-010-008 10076239 Jan 2010 Jan 2010