Appendix A QUICK Specifications



Similar documents
DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Chapter 2 - The TCP/IP and OSI Networking Models

! encor en etworks TM

WEB RANger-II Internet Access Router

DataSMART 681, 696 and 698

Cisco 1600 Series Modular Desktop Access Routers

The BANDIT Device in the Network

Loop-IP6700 TDMoEthernet

Chapter 4 T1 Interface Card

These highly flexible interface cards facilitate several important applications:

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

Overview of the Cisco 2500 Series Access Server

Notes Odom, Chapter 4 Flashcards Set:

In addition to our VoiceDirector hardware products, the following SIP broadband devices are also compatible with VoiceDirector:

Cisco 1603 R Ethernet/ISDN BRI Modular Router Cable Specifications

Product Overview. Features CHAPTER

TDMoEthernet. Description

VALIANT COMMUNICATIONS LIMITED

TECHNICAL SPECIFICATION TSPE 2084 U 0 INTERFACE FOR ISDN BASIC ACCESS

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Cable Connection Procedures for Cisco 1900 Series Routers

Loop-IP6700 TDMoEthernet

Setting Up and Testing the MAX Hardware

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Rack mounted telephone- and leased line modem for industrial applications

Network Monitoring White Paper

Multiband MAX. Multimedia Access Videoconferencing Backup/Overflow. Networking Solutions for High Bandwidth Network Requirements

Loop-IP6510 Multiple WAN Router/Bridge

Loop-IP6702 TDMoEthernet

DXC Family. Multiservice Access Node FEATURES

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

SYNC MAX PCI Adapter

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Data Link Protocols. TCP/IP Suite and OSI Reference Model

Product information begins on page 2. Lucent and Ascend have merged.

This course has been retired. View the schedule of current <a href=

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

The Product Description of SmartAX. MT882 ADSL2+ Router

ORION TELECOM NETWORKS INC. T1

Long Range Ethernet Extender

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

F2400 FOM II Series Fiber Optic Modem Technical Manual

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

Configuring E1 and T1 Interfaces

OV704WVG Product Specifications

enetworks TM BANDIT, C2C, and VSR-1200 Document Set List of Groups and Modules

Computer Networks. Definition of LAN. Connection of Network. Key Points of LAN. Lecture 06 Connecting Networks

XYPLEX Console Servers, MAXserver Console Server Console Server Management, Console Server Software

WANs connect remote sites. Connection requirements vary depending on user requirements, cost, and availability.

WAN. Introduction. Services used by WAN. Circuit Switched Services. Architecture of Switch Services

Controlware Access Backup Solutions

T1 Networking Made Easy

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Wide Area Network Solutions

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

WAN Technology. Heng Sovannarith

Cisco Channelized T1/E1 and ISDN PRI Modules

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

Cable Specifications. T3 Trunk Cabling APPENDIX

Electronic Control Devices The European Product Catalogue 2007

Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

ABB RTU560A Series CMU & Modules

DL TC72 Communication Protocols: HDLC, SDLC, X.25, Frame Relay, ATM

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Configuring E1 and T1 Interfaces

Fundamentals of Telecommunications

Upon completion of this chapter, you should be able to answer the following questions:

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Octal T1-10/100 RIOP Installation Guide

NetVanta 3000 Series (with T1/FT1 or T1/FT1 with DSX-1 Network Interface Module)

Section 11.1, Simple Network Management Protocol. Section 11.2, Port Data Capture

Acer ADSL Surf USB Modem

Wireless Router Setup Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Cisco 1700 Router Overview

IntesisBox KNX Mitsubishi Heavy Industries AC

Acterna DSL Services Tester TPI 350+ Application Highlights

24-Port Channelized E1/T1 Line Card Overview

T3 Mux M13 Multiplexer

WAN Data Link Protocols

PPP (Point-to-Point Protocol)

Remote Monitoring and REC 501 Control Unit Product Guide

Uninterruptible Power Supply

Quidway AR 18-1X Series Router Datasheet

VOICE RECORDING SYSTEM ISDN PRI / BRI

IPmux-1E TDM Pseudowire Access Gateway

This chapter discusses Synchronous Data Link Control (SDLC) protocols that you can configure on a BANDIT device s ports. See the following sections:

Optimux-134, Optimux-125

Optimux-34, Optimux-25

Transcription:

Appendix A QUICK Specifications This section provides details on the various specifications that govern the operation of the units and their CSU/DSUs. Chapter Contents A.1 9500-D -Network Port...A-2 A.2 User,Supervisor and 9500-S Network Ports...A-2 A.3 Interfaces...A-3 A.4 Operating Mode and Format...A-3 A.5 Power Requirements...A-3 A.6 Environmental...A-4 A.7 Protocols Supported...A-5 A.8 SpecificationsSupported...A-5 A.9 Standards Publications...A-6 QUICK II TM Installation Guide Appendix A-1

9500-D -Network Port APPENDIX A QUICK SPECIFICATIONS A.1 9500-D -Network Port DATA RATES 56000/64000 bps synchronous standard four-wire CSU/DSU interface OPERATING RANGE (WITH UNLOADED TWISTED-PAIR CABLES, 24 AWG): SPEED 56000/64000 DISTANCE 4.5 miles Range on heavier gauge cables exceeds the distances above. A.2 User, Supervisor and 9500-S NetworkPorts The unit s data ports can be remotely configured in the software. The data rates, in bit/s, of synchronous and asynchronous data ports are as follows: SYNCHRONOUS ASYNCHRONOUS 1024000 115200 768000 57600 512000 48000 256000 38400 192000 19200 128000 9600 96000 4800 64000 2400 56000 1200 48000 38400 19200 9600 4800 2400 Appendix A-2 Release 1.0.4H

APPENDIX A QUICK SPECIFICATIONS Interfaces A.3 Interfaces CSU/DSU NETWORK PORT USER PORTS AND NON-CSU/ DSU NETWORK PORT (WAN) ETHERNET PORT (LAN) ISDN PORT (WAN) Bipolar Return-to-Zero using an 8-position modular RJ-48S (US) or CA 48S (Canada) jack to allow easy installation. X.21/V.11, V.35, RS-232, or RS-422 on a DB-25 with EIA-530 pinout 10Base-T (RJ-45) and AUI two 64Kbps B-channels and one 16 Kbps D-channel A.4 Operating Mode and Format MODE FORMAT RS-232 Serial V.35 Binary RS-422 X.21 following EIA 530 on DB-25 with an optional adapter cable to M-34 Synchronous Data Asynchronous Data DB-15 connector Ethernet on AUI or 10Base-T (RJ-45) TDI Async half duplex serial A.5 Power Requirements Input voltage Output voltage Input Connector Output Connector Certifications 115v A.C., 60 Hz Cypress: 115v or 230v AC or -48v DC 20-24v A.C., 20 v AC -48v DC (factory installed option) Two prong with ground Four prong molex UL, CSA QUICK II TM Installation Guide Appendix A-3

Environmental APPENDIX A QUICK SPECIFICATIONS The Power Transformers meet the following requirements: NORTH AMERICA Class 2 wall transformer 20-24VAC 20VA 60Hz EU Double insulated, power limited, Safety Extra Low Voltage (SELV) transformer 20-24 VAC 20VA 50Hz A.6 Environmental AMBIENT TEMP 0 to 50 C RELATIVE HUMIDITY 20% to 90% non condensing at 24 ALTITUDE 10,000 Feet max. (3,000 m) WEIGHT 3 lbs. Cypress (empty): 30 lbs. DIMENSIONS 3 x 7 x 9 1/2 Cypress: 10 1/2" x 19 1/4" x 14 3/4" Appendix A-4 Release 1.0.4H

APPENDIX A QUICK SPECIFICATIONS ProtocolsSupported A.7 Protocols Supported ASYNC PPP OVER MODEM FRAME RELAY IP ASYNC AND SYNC PPP SDLC SPOOFING IPX ASYNC ENCAPSULATION SDLC ROUTING X.25 BIT SYNC ENCAPSULATION SNMP/TELNET LLC ANNEX G (X.25 OVER FRAME RELAY) ASYNC AND SYNC POLL/SELECT SPOOFING BYTE SYNC ENCAPSULATION X.25 SWITCHING SLIP ISDN DIAL BACKUP RIP ROUTING SNA RFC-1490 A.8 Specifications Supported GA27-3093 (SDLC) RFC 0793 (TCP) RFC 1055 (SLIP) 1097805 (3/80) (Burroughs-TD) RFCs 0854, 0857, 0858 (Telnet) RFCs 1331, 1332, 1378 (PPP) 1086956 (1/76) (Burroughs) RFC 1294/1490 (Frame Relay) and SNA QUICK II TM Installation Guide Appendix A-5

A.9 StandardsPublications AT&T 41458 Special Access Connections to the AT&T Communications Public Switched Network for New Service Application AT&T 41021 Digital Data System - Channel Interface Specifications AT&T 62310 Digital Data System Channel Interface Specifications AT&T 54075 Subrate Data Multiplexing - A Service Function of Digital Data Service MIL-STD 188-114 Electrical Characteristics of Digital Interface Circuits AT&T 41021A Addendum to 41021 TIA/EIA 596 Net. Channel Terminating Equipment for Public Switched Digital Service - Type 1 AT&T TR62411 ACCUNET(R) T1.5 Service: Description and Interface Specifications AT&T TR54016 Requirements for Interfacing Digital Terminal Equipment to Services Employing the Extended Superframe Format ANSI T1.403-1995 Network-to-Customer Installation-DS1 Metallic Interface ANSI T1.601 ISDN Basic Access: Interface for Use on Metallic Loops: for Application on the Network Side of the NT (Layer 1 Specification) ANSI T1.605 ISDN Basic Access: Interface for S and T Reference Points (Layer 1 Specification) Bellcore Bellcore SR-NWT- 001937 SR-NWT- 002661 National ISDN-1 National ISDN Generic Guidelines for ISDN Terminal Equipment CCITT 1.430 ISDN User-Network Interfaces-Layer 1 Specification (S/T) CCITT Q.921 ISDN User-Network Interface, Data Link Layer Specification CCITT Q.931 ISDN User-Network Interface, Layer 3 Specification ITU G.703 Physical/Electrical Characteristics of Hierarchical Digital Interfaces ITU G.704 Synchronous Frame Structures Used at Primary and Secondary Hierarchical Levels ITU G.732 Characteristics of Primary PCM Multiplex Equipment Operating at 2048 kbit/s ITU G.775 Loss of Signal (LOS) and Alarm Indication Signal (AIS) Defect Detection and Clearance Criteria ITU O.162 Equipment to Perform In-Service Monitoring on 2048,8448, 34 368, and 139 264 Kbit/s Signals Appendix A-6 Release 1.0.4H

APPENDIX A QUICK SPECIFICATIONS StandardsPublications (This Page Intentionally Left Blank) QUICK II TM Installation Guide Appendix A-7

Standards Publications APPENDIX A QUICK SPECIFICATIONS Appendix A-8 Release 1.0.4H