1 Chapter 11 SNMP and Port Data Capture This module discusses the Simple Network Management Protocol (SNMP) and the BANDIT device s Port Data Capture feature, and how they can be used to augment or enhance system management in Encore Networks BANDIT products. See the following sections: Section 11.1, Simple Network Management Protocol Section 11.2, Port Data Capture Note: For information on the BANDIT products standard system management, see Chapter 10, System Management Simple Network Management Protocol The BANDIT can use the Simple Network Management Protocol (SNMP), a standard for network management. SNMP has several advantages that

2 11-2 Chapter 11: SNMP and Port Data Capture contribute to its popularity for example, it is extensible, allowing vendors to easily add network management functions. SNMP also separates the management architecture from the architecture of the hardware devices, which broadens the base of multivendor support. SNMP contains two primary elements: a manager and agents. The manager is the software on the console through which a (human) network administrator performs network management functions. An agent is the software entity that interfaces to a device being managed. Bridges, routers, and network servers are examples of managed devices. Managed devices contain managed objects. Managed objects are items such as hardware, configuration parameters, performance statistics, and so on, that directly relate to the operation of the device. These objects are arranged in a management information base (MIB). SNMP managers and agents communicate in order to view and use these MIBs. Different types of MIBs are available, including the internet standard MIB, defined in Request for Comments (RFC) documents 1212 and 1213; the remote monitoring MIB, defined in RFC 1271; and private-enterprise MIBs that vendors define for their products. Encore Networks, Inc., supports MIB II with Encore Networks proprietary extensions. The SNMP manager reads the values of the objects within a MIB and modifies the values as appropriate in other words, it manages the objects. Because SNMP is an application-layer protocol, it must rely on protocols in the lower OSI layers for other communication functions. For example, the User Datagram Protocol (UDP) transports the SNMP message through the network. IP provides network-layer functions, such as addressing for the datagram SNMP Access to the BANDIT SNMP version 1 access is available on all BANDIT models. In conformance with RFC 1294/1490, the BANDIT can be remotely accessed via SNMP over any network infrastructure, including IP, Frame Relay, SLIP, and PPP. The BANDIT supports standard MIB II variables, in addition to proprietary extensions developed by Encore Networks, Inc. Other parameters the SNMP Network Manager uses are the Get Community string (to read SNMP variables) and the Set Community string (to write SNMP variables).

3 Simple Network Management Protocol 11-3 Note: See Appendix D, Default Passwords, for the default values of the BANDIT device s SNMP Get Community string and Set Community string. To gain SNMP access to the BANDIT, you must configure the SNMP parameters on the BANDIT and you must configure an SNMP manager on the control terminal. See the following sections: Section , The BANDIT SNMP Agent Section , The SNMP Manager The BANDIT SNMP Agent The SNMP agent is part of the BANDIT software and thus always resides in the BANDIT. You need to configure the BANDIT s SNMP settings so that the SNMP manager can manage the BANDIT. Configure the BANDIT s SNMP Get and Set communities, its SNMP Trap Table, and a default SNMP trap address. (The default SNMP trap address is the SNMP manager s IP address.) Predefined SNMP Traps The BANDIT supports several predefined SNMP traps: Port Down. This allows the unit to send a message to the SNMP manager indicating that a physical entity, such as a cable or a CSU/DSU, is not functional. Network Down. This allows the unit to send a message to the SNMP manager indicating that the switch is not responding. DLCI Down. This allows the unit to send a message to the SNMP manager indicating that a DLCI is down. Checkstatus. This is reserved for use in testing. Memorylow. This is generated when units have insufficient memory. Physicallineup. This is sent when DTR ON has been detected by any physical port. Physicallinedown. This is sent when DTR DOWN has been detected by any physical port.

4 11-4 Chapter 11: SNMP and Port Data Capture FRportmgmtup. This is sent when Frame Relay management is up. If the BANDIT plays the network role in the Frame Relay connection, this means that the port starts responding to polls. If the BANDIT plays the user role in the Frame Relay connection, this means that the port begins receiving responses to polls. (The user role is always sending polls across the Frame Relay network.) FRportmgmtdown. This is sent when Frame Relay management is down. If the BANDIT plays the network role in the Frame Relay connection, this means that the port stops responding to polls. If the BANDIT plays the user role in the Frame Relay connection, this means that the port stops receiving responses to polls. FRdlciup. This is sent when a DLCI is active, when the previous status was new or DLCIDown. FRdlcidown. This is sent when a DLCI is inactive, when the previous status was new or DLCIUp SNMP Configuration in the BANDIT Note: This procedure must be performed via the direct connection between the BANDIT device and the local management console. 1 On the BANDIT s Main Menu, select System Administration. On the System Administration menu, select SNMP Configuration. The following menu is displayed. This menu sets passwords (i.e., a Get Community string and a Set Community string) for SNMP management. This menu also configures trap addresses (in the SNMP Trap Table) and sets a default trap address. 1) SNMP Get Community String : ****** 2) SNMP Set Community String : ****** 3) SNMP Trap Default Addr : ) SNMP Trap Table Enter Choice:

5 Simple Network Management Protocol 11-5 Note: See Appendix D, Default Passwords, for the BANDIT device s SNMP Get and Set Community Strings. 2 Select Get Community String. Note: The Get string lets you view (read) the remote device s configuration. The following prompt is displayed: Define SNMP Get Community String: a Enter the Get community string. 3 Select Set Community String. Note: The Set string lets you modify (write) the remote device s configuration. The following prompt is displayed: Define SNMP Set Community String: a Enter the Set community string. 4 Select SNMP Trap Default Addr to set the default trap address. The following prompt is displayed:

6 11-6 Chapter 11: SNMP and Port Data Capture Enter SNMP Trap Default Address (N.N.N.N): a Enter the IP address of the terminal that runs the SNMP manager, and press Enter. 5 Select SNMP Trap Table to record up to five trap addresses. The following prompt is displayed: Enter Trap Address (N.N.N.N): a Enter a trap address and press Enter. A prompt for the next table entry appears. 6 You can continue entering addresses, or you can press Escape to return to the SNMP menu. 7 When you have finishing configuring the BANDIT, Write (save) the configuration and Reset the BANDIT. See the following sections: Section 3.3.7, Write Configuration Section 3.3.8, Reset Unit 8 If you have not yet done so, configure the SNMP manager on your control terminal The SNMP Manager To use an SNMP manager, you must configure the manager to use the Get and Set string that match those configured in the BANDIT. In addition, you must compile the SNMP manager s MIBs MIB Compilation Before you can use an SNMP manager to communicate with a device s SNMP agent, you must compile the manager s MIBs. MIBs must be

7 Simple Network Management Protocol 11-7 compiled in a specific order. Follow the instructions in the SNMP manager s user guide to organize and compile the MIBs. Note: To receive the Encore Networks proprietary MIBs, contact your Encore Networks representative. The order for compiling the Encore Networks MIBs is easy; just compile the Encore Networks MIB files in alphabetic order. (Private MIBs from other organizations do not necessarily follow alphabetic order when compiling.) Figure 11-1 through Figure 11-3 provide one example of looking at the private MIBs available on the SNMP Manager. (This example uses Castle Rock Computing s SNMPc, a Windows-based SNMP manager.) Figure Selecting SNMP MIB Browser

8 11-8 Chapter 11: SNMP and Port Data Capture Figure SNMP MIBs Directory Figure SNMP MIBs Subdirectory PRIVATE, Expanded

9 Simple Network Management Protocol Encore Networks MIB Extensions In addition to the standard MIBs in MIB II, the BANDIT uses proprietary MIB extensions from Encore Networks, Inc. The BANDIT uses the following proprietary MIB file: Fc.mib This file is divided into three subfiles: Fc_fastc.mib Fc_port.mib Fc_stats.mib The Fc_fastc.mib file is further divided into three groups: Registration Group. The Registration group contains only the Object Identifiers for all products. Temporary Group. The Temporary group contains experimental MIB variables not yet released. Product Group. The Product group comprises two subgroups: - The snmpagent subgroup contains several subgroups, described below. The snmpagent subgroup contains all SNMP-specific parameters. SNMP variables match the menu parameters and ranges used for unit configuration. The snmpagent subgroup consists of the following files: snmpmibversion snmpagentipaddr snmpagentname snmpagentsetcommunity snmpagentgetcommunity snmpagentdefaulttrapipaddr snmpagenttrapsendtable - The FrameRelay subgroup contains another subgroup called fsfrad. The fsfrad subgroup contains all SNMP-specific parameters. Table 11-1 lists the fsfrad subgroups and their component subgroups.

10 11-10 Chapter 11: SNMP and Port Data Capture Note: The fs at the beginning of these MIBs represents the BANDIT. The BANDIT parameters have up to 30 virtual logical ports, from 0 to 29. Table fsfrad subgroups (1 of 3) fsfrad Subgroup fsgeneralparms Component Subgroups fsreloadfactoryvalues, fsresetunit, fssavetononvolatile, FsFirmwareVersion, fsparammodstatus, fsclearallstats, fsclocksource, fsactivecoderegion, fssoftwareversion, fsmacaddr, fsdatabase, fsactivedatabase, fsdatabasetobeused, fscleardatabase, fssystemone, fsnetworkloader, fshostipaddr, fscodefilename, fsloadtimeout, fsregion1priority, fsregion2priority, fsactivedatabase, fseraseinactiveregion, fsinitdownload, fsnetloadersectortable, fscsudsuspeed, fsdistributedsystem, fsfradrole, fsfradboardtable, fsremotelogging, fsipfilteringremotelogstatus, fsipfilteringremotelogaddr, fsipfilteringremotelogfac, fscopyconfig, fslocaloctype, fslocaloadmethod, fslocatftpseraddr, fslocatftpfilename, fslocbloctype, fslocbloadmethod, fslocbtftpseraddr, fslocbtftpfilename, fsinitcopyatob, fsinitcopybtoa, fsinitcopyactionstatus

11 Simple Network Management Protocol Table fsfrad subgroups (2 of 3) fsfrad Subgroup fsrouting fsstats fst1dsuconfig Component Subgroups fsiprouting, fsiproutingmode, fsipstatisrouting, fsipdefaultrouter, fsiptodlcitable, fsipripipframepri, fsipripipv2passwed, fsipripipdynlinksupport, fsipripacclist1action, fsipripacclist2action, fsipripacclist3action, fsipripacclist4action, fsipripacclist5action, fsipripacclist1table, fsipripacclist2action, fsipripacclist3action, fsipripacclist4action, fsipripacclist5action, fsipripinterfacetable, fsipripstatictable, fsiprippacketpri, fsipbootpaddress, fsipnametable, fsipfiltering, fsipfilteringenable, fsipfilteringremotelog, fsipfilteringtable, fsippriority, fsipprienable, fsippridefpriority, fsippritable, fsipdhcp, fsipdhcpprimaryaddr, fsipdhcpsecondaryaddr, fsipnat, fsipnatcfg1natstatus, fsipnatcfg1ipmasmode, fsipnatcfg1natipmasaddr, fsipnatcfg1pmasaddr, fsipnatcfg1remotelog, fsipnatcfg1statictable, fsipnatcfg2natstatus, fsipnatcfg2ipmasmode, fsipnatcfg2natipmasaddr, fsipnatcfgremotelog, fsipnatcfg2statictable, fsipxrouting, fsipxroutingmethod, fsipxencapsulationmethos, fsipxpassthrugptname, fsipmframerelaypri, fsipmrippacketpri, fsipxsappacketpri, fsipxwanflag, fsipxprimarynetwork, fsipxroutername, fsipxnetworksize, fsipxroutetable, fsipxtableentry, FsIpxTableEntry, fsipxindex, fsipxnetnum, fsipxpri, fsipxgptname, fsipxsapmode, fsipxstatus, fsframerelayrouting, FsFrameRelayRoutingTable, fssna, fsx25newglob, FsX25NewGlobSwEntry FC_STATS.MIB: fsframerelaystats, fsasyncencapsulationstats, fsbitsyncencapsulationstats, fsslipstats, fsriproutingstats, fsasyncburosemulationstats, fssyncburosemulationstats, fssdlcroutingstats, fsbytesyncencapsulationstats, fstelnetterminalstats, fsipxstats, fsalcstats, fstokenstats, fsetherstats, fsipstats, fsicmpstats, fsudpstats, fstcpstats, fssnmpstats, fsnetloaderstats, fsprioritystats, fssdlc2stats, fsllcstats, fssnaswstats, fst1dsustats, fse1dsustats, fsx25newstats, fsxpadstats, fsisdnstats, fsipfilteringstats, fsnewpppstats, fsmlpstats fst1dsuframeformat, fst1dsulinecode, fst1dsubitstuffing, fst1dsulinebuildout, fst1dsuclock, fst1dsulineloopback, fst1dsutimeslotdatarate, fst1dsutimeslots, fst1dsutimeslotdatatype, fst1dsuyellowalarm, fst1dsuloopbacklocalanalog, fst1dsuloopbacklocaldigit, fst1dsuloopbackremoteanalog, fst1dsuloopbackremotedigit

12 11-12 Chapter 11: SNMP and Port Data Capture Table fsfrad subgroups (3 of 3) fsfrad Subgroup fse1dsuconfig fsgpt fsisdnconfig fsextdialupdev fsportprotocol Component Subgroups fse1dsuframeformat, fse1dsucrc, fse1dsuclock, fse1dsulineloopback, fse1dsutimeslots, fse1dsudatatype, fse1dsudisframe, fse1dsuaistrans fsgpttable, FsGPTEntry, fsgptentry, fsgptindex, fsgptpathname, fsgptpathtype, fsgptport, fsgptdlcinum, fsgptbackuppathname, fsgptcallingaddress, fsgptcalledaddress, fsgptpvcnumber, fsgptadminstatus fsisdnenable, fsisdnlocalphel, fsisdnspid1, fsisdnlocalphe2, fsisdnspid2, fsisdnswitchsel fsextdialupdevtable, FsExtDialupDevEntry, fsextdialupdeventry, fsextdevindex, fsextdevport, fsextdevmodemtype, fsextdevstatus FC-PORT-MI: fsportdefinition. fsframerelay, fsasyncencapsulation, fsbitsyncencapsulation, fsslip, fsasyncburosemulation, fssyncburosemulation, fssdlcroute, fsbytesyncencapsulation, fstelnetterminal, fsalc, fssdlc2, fsx25new, fsxpad, fspppnew, fspppmlink, fsethernet, fstokenring Preparing an SNMP Connection To configure and manage the unit, connect the terminal to the Supervisor port. Press Enter to access the system. Use the BANDIT menus to configure the system. When you have finished the session, save (write) the configuration. Then select Exit from the Main Menu to terminate the session. To set up an SNMP connection, configure the following items: IP Address. This option allows the user to configure a valid IP Local Address via an async terminal. (See Section 4.2, Identifying the BANDIT in the Network.) Config port. This option allows the user to configure a port as Frame Relay, SLIP, or PPP via an async terminal, depending on the desired access method. An IP Routing table must also be configured. Ping. This option pings the configured IP Address to test connectivity. Config agent trap. This option allows the user to configure the snmpagenttrapipaddr parameter (within the snmpagent subgroup) with the IP address of the Network Manager. The unit sends SNMP traps to that address.

13 Simple Network Management Protocol Modify Get/Modify Set. These options allow the user to modify the Get and/or Set Community names (parameters snmpagentgetcommunity and snmpagentsetcommunity within the snmpagent subgroup). Select protocol. This option allows the user to select the appropriate protocol under the fsportprotocol MIB. Set the SNMP parameters for the protocol. Save. This option allows the user to save all the parameters into the unit s non-volatile database by setting the fssavetononvolatile parameter (within fsgeneralparms) to Initiate. Reset. This option allows the user to reset the unit by setting the fsresetunit parameter (within fsgeneralparms) to Initiate Adding, Deleting, Modifying, and Viewing Table Entries You can add, delete, modify, or view any table entry in the SNMP manager. The default value for table entries is View. To add an entry, put the cursor anywhere in the table, and select the dropdown list in the Status column. Select Add. A row is added to the end of the table. To delete an entry, put the cursor in the row you want to delete, and select the dropdown list in the Status column. Select Delete. The row is removed from the table. To modify an entry, put the cursor in the row you want to modify. Select the dropdown list in the Status column and select Modify. Make the necessary changes. Note: All entries are indexed by port number, protocol name, and other variables Using SNMP to View the BANDIT Menus In addition to standard methods of using SNMP to manage the BANDIT, you can go through the SNMP Manager to view the BANDIT s menus. The following procedure describes how to view the BANDIT menus through the SNMP Manager.

14 11-14 Chapter 11: SNMP and Port Data Capture How to Use the SNMP Manager to View the BANDIT Menus Note: This example uses Castle Rock Computing s SNMPc, a Windowsbased SNMP Manager. 1 In the SNMP Manager, make sure you have configured an SNMP device for the BANDIT. (To configure the device settings, follow the instructions in the SNMP manager s instruction manual.) The BANDIT s SNMP device configuration must include the following: The BANDIT s IP address. This allows the SNMP Manager to find the BANDIT on the network. The BANDIT s Get Community string. This allows the SNMP Manager to view the BANDIT s settings. Note: The default value for the BANDIT s SNMP Get Community string is listed in Appendix D, Default Passwords. The BANDIT s Set Community string. This allows the SNMP Manager to configure and save the BANDIT s settings. Note: The default value for the BANDIT s SNMP Set Community string is listed in Appendix D, Default Passwords. 2 Select the BANDIT SNMP device. The device is highlighted (Figure 11-4).

15 Simple Network Management Protocol Figure BANDIT SNMP Device, Highlighted 3 On the top menu, or by right-clicking the SNMP device, select a Telnet connection. (On the example shown in Figure 11-5, using Castle Rock Computing s SNMPc, the menu choices are Tools, Connect Telnet.) Figure Selecting a Telnet Connection through the SNMP Manager A Telnet window opens, asking for the remote password for the BANDIT.

16 11-16 Chapter 11: SNMP and Port Data Capture 4 Type the remote password and press Enter. Note: Default passwords are listed in Appendix D. The BANDIT s main menu appears (Figure 11-6). 5 Use the BANDIT menus to configure and monitor the BANDIT. Figure BANDIT s Main Menu, Telnetted through SNMP Manager Using SNMP with Port Data Capture Port Data Capture (PDC) can be used in conjunction with SNMP to enhance troubleshooting, especially when a problem is intermittent. The Encore Networks device can be programmed to send an SNMP trap under certain conditions e.g., when an intermittent problem is actually occurring. The SNMP management station can be programmed to issue a script, based on this SNMP trap, that starts a Port Data Capture to run for a predetermined amount of time e.g., 15 minutes. The network administrator can retrieve the captured data later for analysis. For details, see Section 11.2, Port Data Capture.

17 Port Data Capture Port Data Capture Port Data Capture (PDC) is a powerful troubleshooting feature embedded in all of Encore Networks data products, including the BANDIT. The port trace functionality allows the unit to monitor data packets on any or all of a unit s data ports. This feature helps resolve network problems by displaying live data for the ports. PDC encompasses features to troubleshoot legacy traffic on serial interfaces and to troubleshoot IP traffic. No external test or monitoring hardware is required for monitoring data packets on the LAN, WAN, modem, serial, or expansion ports. Example: Suppose a product at a remote branch is having problems with data traffic. The remote site can notify the central office by sending an SNMP trap/alarm to an SNMP Manager. An operator at the central office can remotely access the product s menus, selecting Port Data Capture. Depending on the problem, the operator may select one or more ports to analyze the data traffic. Use of PDC from a remote site saves the cost of sending a service person carrying hardware and software to the site to troubleshoot the problem Features of Port Data Capture All ports on all BANDIT models support Port Data Capture: Ethernet LAN, WAN, and DMZ T1/E1 CSU 56k/64k DSU Serial Modem The Remote Data Unit, used with the BANDIT Plus and the VSR-1200, also supports PDC on its Ethernet port and on all 12 serial ports. PDC has the following features: The user can select the format ASCII, EBCDIC, or hexadecimal for the information the PDC displays.

18 11-18 Chapter 11: SNMP and Port Data Capture The captured information can be monitored live, can be captured and stored, or can be captured and sent to the central office for analysis. PDC can be set to monitor data indefinitely or for a specific time period. The default is 3 hours. The user can determine the amount of memory used to capture data. When starting a capture, the menu prompts for buffer size and capture slice. The user can accept the defaults or enter new values. The default capture slice is 64 bytes and the default buffer allocation is 75,000 bytes. The maximum allowed buffer is 3.4 Mbytes. PDC does not affect the operation of the Encore Networks product or any of its ports. PDC is passive; it requires no processing resource and runs quietly in the background. Note: The settings for Port Data Capture cannot be saved as part of the BANDIT device s configuration. How to Use the Port Data Capture Feature 1 From the Main Menu, select System Administration >> Port Data Capture. The Data Capture Port Selection and Status menu appears. Data Capture - Port selection and status M) MODEM : OFF L) LAN : OFF W) WAN : OFF S) SERIAL : OFF Enter Choice : 2 Do one of the following: a b Press the Escape key to return to the higher menu. Select the port you wish to monitor.

19 Port Data Capture The port s Capture menu, similar to the following, is displayed. The menu shown here indicates that the port s capture status is Off. Capture of : SERIAL currently OFF ) Start a capture 2) Stop a capture 3) Clear capture buffer 4) Display captured data 5) Dump captured data to the screen Enter Choice : 3 Do one of the following: a To return to the Data Capture Port Selection menu, press the Escape key. The Data Capture Port Selection menu appears. Go to Step 2. b To capture this port s data, select Start a Capture. The following prompts appear. Answer them as appropriate for your network, and press Enter. (Or just press Enter, without typing anything, to accept the defaults.) Enter max slice [64] : Enter max buffer [75000] : Enter Timeout value in hours [3] :

20 11-20 Chapter 11: SNMP and Port Data Capture After you have entered values (or accepted defaults) for the parameters, the following message appears. ** Capture started ** Then the port s Capture menu re-appears. Note that the port status indicates that capturing is in progress. Repeat Step 3. Capture of : SERIAL currently CAPTURING Total= ) Start a capture 2) Stop a capture 3) Clear capture buffer 4) Display captured data 5) Dump captured data to the screen Enter Choice : c If you want to stop a capture before it times out, select Stop a Capture. The following message appears, followed by the port s Capture menu, showing the port capture status as Stopped. Repeat Step 3. ** Capture stopped ** d To clear the capture buffers, and to turn off a capture session, select Clear Capture Buffer. The following message appears, followed by the port s Capture menu, showing capture status as Off. Repeat Step 3. ** Capture buffer cleared **

21 Port Data Capture e To see a line-by-line display of the port data, select Display Captured Data. Go to Step 4. The menu for display mode appears. 1) Normal mode 2) Summary mode Enter mode [1] : f To see a complete display of the captured port data, select Dump Captured Data to the Screen. The format selection menu appears. Go to Step 6. Enter Choice : 5 1) ASCII format 2) EBCDIC format 3) Hexadecimal format Enter format [1] : 4 For a line-by-line display of captured data, do the following: a Select the mode you wish to view: A menu to select the format appears: 1) ASCII format 2) EBCDIC format 3) Hexadecimal format Enter format [1] : b Select the format for the display. The screen displays capture data for this port. (If there are no data, the message indicates that.) After the display, a line asks for the next line of data you wish to view.

22 11-22 Chapter 11: SNMP and Port Data Capture *** Capture buffer for this port is empty *** Enter [(F)irst, (N)ext, (S)pecific or (C)hange format]: 5 Do one of the following: a To stop the data display, press the Escape key. The port s Capture menu is redisplayed. Go to Step 3. b To change the display format, select Change Format. The menu for display mode appears again. Go to Step 4a. c To view a specific line, select Specific. A prompt asks for the line number. Enter line number : Type the line number and press Enter. The display continues. Repeat Step 5. d To view the first line again, select First. The display continues. Repeat Step 5. e To view the next line, select Next. The display continues. Repeat Step 5. 6 For a complete display of captured data, do the following: a Select the format for the display.

23 Port Data Capture Start the file capture, press to display capture b To display the data, press the Enter key. The information is displayed on the screen. *** Capture buffer for this port is empty *** After the data have been displayed, the capture is automatically stopped. Stop the file capture Then the port s Capture menu is redisplayed. Go to Step 3. Capture of : SERIAL currently STOPPED Total= ) Start a capture 2) Stop a capture 3) Clear capture buffer 4) Display captured data 5) Dump captured data to the screen Enter Choice :

24 11-24 Chapter 11: SNMP and Port Data Capture

! encor en etworks TM

! encor en etworks TM ! encor en etworks TM Version A, March 2010 2013 Encore Networks, Inc. All rights reserved. Configuring the BANDIT III s T1 E1 Card for a PCM Voice Network The T1 E1 card fits into the expansion slot on

More information

This chapter discusses Synchronous Data Link Control (SDLC) protocols that you can configure on a BANDIT device s ports. See the following sections:

This chapter discusses Synchronous Data Link Control (SDLC) protocols that you can configure on a BANDIT device s ports. See the following sections: encor! enetworks TM Version A, September 2010 2010 Encore Networks, Inc. All rights reserved. SDLC Protocol Configuration This chapter discusses Synchronous Data Link Control (SDLC) protocols that you

More information

enetworks TM IP Quality of Service B.1 Overview of IP Prioritization

enetworks TM IP Quality of Service B.1 Overview of IP Prioritization encor! enetworks TM Version A, March 2008 2010 Encore Networks, Inc. All rights reserved. IP Quality of Service The IP Quality of Service (QoS) feature allows you to assign packets a level of priority

More information

! encor e networks TM

! encor e networks TM ! encor e networks TM Revision I.2, April 2009 Document Part Number 14973.1001 Copyright 2009 Encore Networks, Inc. All rights reserved. BANDIT, BANDIT IP, and BANDIT Plus Installation Guide for ELIOS

More information

52-20-15 RMON, the New SNMP Remote Monitoring Standard Nathan J. Muller

52-20-15 RMON, the New SNMP Remote Monitoring Standard Nathan J. Muller 52-20-15 RMON, the New SNMP Remote Monitoring Standard Nathan J. Muller Payoff The Remote Monitoring (RMON) Management Information Base (MIB) is a set of object definitions that extend the capabilities

More information

enetworks TM Using the Syslog Feature C.1 Configuring the Syslog Feature

enetworks TM Using the Syslog Feature C.1 Configuring the Syslog Feature encor! enetworks TM Version A, March 2010 2013 Encore Networks, Inc. All rights reserved. Using the Syslog Feature This document provides basic information for using the syslog feature in the ELIOS software.

More information

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Firewall VPN Router. Quick Installation Guide M73-APO09-380 Firewall VPN Router Quick Installation Guide M73-APO09-380 Firewall VPN Router Overview The Firewall VPN Router provides three 10/100Mbit Ethernet network interface ports which are the Internal/LAN, External/WAN,

More information

Monitoring and Analyzing Switch Operation

Monitoring and Analyzing Switch Operation B Monitoring and Analyzing Switch Operation Contents Overview..................................................... B-3....................................... B-4 Menu Access To Status and Counters.........................

More information

The BANDIT Device in the Network

The BANDIT Device in the Network encor! enetworks TM Version A.1, March 2010 2013 Encore Networks, Inc. All rights reserved. The BANDIT Device in the Network The BANDIT II and the BANDIT III, ROHS-compliant routers in the family of BANDIT

More information

Basic Network Configuration

Basic Network Configuration Basic Network Configuration 2 Table of Contents Basic Network Configuration... 25 LAN (local area network) vs WAN (wide area network)... 25 Local Area Network... 25 Wide Area Network... 26 Accessing the

More information

Network Management & Security (CS 330) RMON

Network Management & Security (CS 330) RMON Network Management & Security (CS 330) RMON Dr. Ihsan Ullah Department of Computer Science & IT University of Balochistan, Quetta Pakistan November 08, 2013 CS 330 RMON 1/13 1 / 13 Outline Remote Network

More information

Configuring a BANDIT Product for Virtual Private Networks

Configuring a BANDIT Product for Virtual Private Networks encor! enetworks TM Version A, March 2008 2013 Encore Networks, Inc. All rights reserved. Configuring a BANDIT Product for Virtual Private Networks O ne of the principal features in the BANDIT family of

More information

SNMPc Release 7.0 Disaster Recovery Support. Castle Rock Computing March, 2004

SNMPc Release 7.0 Disaster Recovery Support. Castle Rock Computing March, 2004 SNMPc Release 7.0 Disaster Recovery Support Castle Rock Computing March, 2004 Overview Communication networks have become an indispensable part of modern enterprises. Employee and customer interaction,

More information

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva) VPN WAN LAN PWR STAT TD RD TD RD TD RD VPN WAN LAN PWR STAT TD RD TD RD TD RD NetVanta 3200 NetVanta 3200 NetVanta Series (with T1/FT1 or T1/FT1 + DSX-1 Network Interface Module) Quick Configuration Guide

More information

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication

More information

Legacy vs. IP Version Software 2. Getting Familiar with thesystem

Legacy vs. IP Version Software 2. Getting Familiar with thesystem Legacy vs. IP Version Software 2 Chapter 2 Getting Familiar with thesystem This section describes the menu system, port options, and basic operational procedures used in working with the firmware. 2.1

More information

Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch

Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch University of Jordan Faculty of Engineering & Technology Computer Engineering Department Computer Networks Laboratory 907528 Lab. 2 Network Devices & Packet Tracer Objectives 1. To become familiar with

More information

SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)

SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP) 1 SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP) Mohammad S. Hasan Agenda 2 Looking at Today What is a management protocol and why is it needed Addressing a variable within SNMP Differing versions Ad-hoc Network

More information

SolarWinds Certified Professional. Exam Preparation Guide

SolarWinds Certified Professional. Exam Preparation Guide SolarWinds Certified Professional Exam Preparation Guide Introduction The SolarWinds Certified Professional (SCP) exam is designed to test your knowledge of general networking management topics and how

More information

Chapter 2 - The TCP/IP and OSI Networking Models

Chapter 2 - The TCP/IP and OSI Networking Models Chapter 2 - The TCP/IP and OSI Networking Models TCP/IP : Transmission Control Protocol/Internet Protocol OSI : Open System Interconnection RFC Request for Comments TCP/IP Architecture Layers Application

More information

Multi-Homing Dual WAN Firewall Router

Multi-Homing Dual WAN Firewall Router Multi-Homing Dual WAN Firewall Router Quick Installation Guide M73-APO09-400 Multi-Homing Dual WAN Firewall Router Overview The Multi-Homing Dual WAN Firewall Router provides three 10/100Mbit Ethernet

More information

NetVanta 3000 Series (with T1/FT1 or T1/FT1 with DSX-1 Network Interface Module)

NetVanta 3000 Series (with T1/FT1 or T1/FT1 with DSX-1 Network Interface Module) VPN WAN LAN PWR STAT TD RD TD RD TD RD VPN WAN LAN PWR STAT TD RD TD RD TD RD NetVanta 3000 Series (with T1/FT1 or T1/FT1 with DSX-1 Network Interface Module) Quick Configuration Guide 61200862L1-42A November

More information

WhatsUpGold. v3.0. WhatsConnected User Guide

WhatsUpGold. v3.0. WhatsConnected User Guide WhatsUpGold v3.0 WhatsConnected User Guide Contents CHAPTER 1 Welcome to WhatsConnected Finding more information and updates... 2 Sending feedback... 3 CHAPTER 2 Installing and Configuring WhatsConnected

More information

Network Monitoring with SNMP

Network Monitoring with SNMP Network Monitoring with SNMP This paper describes how SNMP is used in WhatsUp- Professional and provides specific examples on how to configure performance, active, and passive monitors. Introduction SNMP

More information

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004 Prestige 202H Plus ISDN Internet Access Router Quick Start Guide Version 3.40 12/2004 Table of Contents 1 Introducing the Prestige...3 2 Hardware Installation...4 2.1 Rear Panel...4 2.2 The Front Panel

More information

NMS300 Network Management System

NMS300 Network Management System NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate

More information

Internetworking Microsoft TCP/IP on Microsoft Windows NT 4.0

Internetworking Microsoft TCP/IP on Microsoft Windows NT 4.0 Internetworking Microsoft TCP/IP on Microsoft Windows NT 4.0 Course length: 5 Days Course No. 688 - Five days - Instructor-led Introduction This course provides students with the knowledge and skills required

More information

There are numerous ways to access monitors:

There are numerous ways to access monitors: Remote Monitors REMOTE MONITORS... 1 Overview... 1 Accessing Monitors... 1 Creating Monitors... 2 Monitor Wizard Options... 11 Editing the Monitor Configuration... 14 Status... 15 Location... 17 Alerting...

More information

Lab 5.5.3 Developing ACLs to Implement Firewall Rule Sets

Lab 5.5.3 Developing ACLs to Implement Firewall Rule Sets Lab 5.5.3 Developing ACLs to Implement Firewall Rule Sets All contents are Copyright 1992 2007 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 1 of 8 Device Interface

More information

How To Understand and Configure Your Network for IntraVUE

How To Understand and Configure Your Network for IntraVUE How To Understand and Configure Your Network for IntraVUE Summary This document attempts to standardize the methods used to configure Intrauve in situations where there is little or no understanding of

More information

SNMP Monitoring: One Critical Component to Network Management

SNMP Monitoring: One Critical Component to Network Management Network Instruments White Paper SNMP Monitoring: One Critical Component to Network Management Although SNMP agents provide essential information for effective network monitoring and troubleshooting, SNMP

More information

WANPIPE TM. Multi-protocol WANPIPE Driver CONFIGURATION M A N U A L. Author: Nenad Corbic/Alex Feldman

WANPIPE TM. Multi-protocol WANPIPE Driver CONFIGURATION M A N U A L. Author: Nenad Corbic/Alex Feldman WANPIPE TM Multi-protocol WANPIPE Driver CONFIGURATION M A N U A L Author: Nenad Corbic/Alex Feldman Copyright (c) 1995-2002 Sangoma Technologies Inc. Introduction WANPIPE from Sangoma Technologies Inc.

More information

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7 Contents Introduction--1 Product definition 1 Implementing SNMP 2 Integrating SNMP into the user interface 3 Components of OPC SNMP Gateway 4 How to Obtain an OPC License--5 Creating a System Code 5 Entering

More information

Cisco Cable DVB/DAVIC Management Program

Cisco Cable DVB/DAVIC Management Program CHAPTER 3 This chapter describes the supplied by Cisco for configuring and monitoring the Cisco DVB CAR100. It includes the following sections: Introducing the Minimum PC Requirements for the Installing

More information

Network Monitoring with SNMP

Network Monitoring with SNMP Network Monitoring with SNMP This document describes how SNMP is used in WhatsUp Gold v11 and provides examples on how to configure performance, active, and passive monitors. Introduction SNMP (Simple

More information

Lab 9.1.1 Organizing CCENT Objectives by OSI Layer

Lab 9.1.1 Organizing CCENT Objectives by OSI Layer Lab 9.1.1 Organizing CCENT Objectives by OSI Layer Objectives Organize the CCENT objectives by which layer or layers they address. Background / Preparation In this lab, you associate the objectives of

More information

Technical Support Information

Technical Support Information Technical Support Information Broadband Module/Broadband Module Plus Configuration Guidance Setting up Remote Access to a Network Device (Mail/File Server/Camera Etc) connected to the LAN port of the Broadband

More information

Figure 1 - T1/E1 Internet Access

Figure 1 - T1/E1 Internet Access Page 1 of 17 TECH NOTE Configuring T1 and E1 Internet Access in AOS Overview This guide explains how to configure an Adtran Operating System (AOS) router for T1/E1 Internet access. You should use this

More information

ITEC310 Computer Networks II

ITEC310 Computer Networks II ITEC310 Computer Networks II Chapter 28 Network Management: Department of Information Technology Eastern Mediterranean University Objectives 2/60 After completing this chapter you should be able to do

More information

! encor e networks TM

! encor e networks TM ! encor e networks TM Version A.1, March 2008 Copyright 2008 Encore Networks, Inc. All rights reserved. Activating a Wireless Card in a Carrier Network Wireless connections use radiofrequencies (RF) through

More information

VOIP-211RS/210RS/220RS/440S. SIP VoIP Router. User s Guide

VOIP-211RS/210RS/220RS/440S. SIP VoIP Router. User s Guide VOIP-211RS/210RS/220RS/440S SIP VoIP Router User s Guide Trademarks Contents are subject to revise without prior notice. All trademarks belong to their respective owners. FCC Warning This equipment has

More information

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev. Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of

More information

Assignment One. ITN534 Network Management. Title: Report on an Integrated Network Management Product (Solar winds 2001 Engineer s Edition)

Assignment One. ITN534 Network Management. Title: Report on an Integrated Network Management Product (Solar winds 2001 Engineer s Edition) Assignment One ITN534 Network Management Title: Report on an Integrated Network Management Product (Solar winds 2001 Engineer s Edition) Unit Co-coordinator, Mr. Neville Richter By, Vijayakrishnan Pasupathinathan

More information

Prestige 310. Cable/xDSL Modem Sharing Router. User's Guide Supplement

Prestige 310. Cable/xDSL Modem Sharing Router. User's Guide Supplement Prestige 310 Cable/xDSL Modem Sharing Router User's Guide Supplement Domain Name Support Enhanced WAN Setup Remote Node Support PPPoE Support Enhanced Unix Syslog Setup Firmware and Configuration Files

More information

Data Link Protocols. TCP/IP Suite and OSI Reference Model

Data Link Protocols. TCP/IP Suite and OSI Reference Model Data Link Protocols Relates to Lab. This module covers data link layer issues, such as local area networks (LANs) and point-to-point links, Ethernet, and the Point-to-Point Protocol (PPP). 1 TCP/IP Suite

More information

Connecting the DG-102S VoIP Gateway to your network

Connecting the DG-102S VoIP Gateway to your network Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information

More information

Protecting the Home Network (Firewall)

Protecting the Home Network (Firewall) Protecting the Home Network (Firewall) Basic Tab Setup Tab DHCP Tab Advanced Tab Options Tab Port Forwarding Tab Port Triggers Tab DMZ Host Tab Firewall Tab Event Log Tab Status Tab Software Tab Connection

More information

Multi-Homing Security Gateway

Multi-Homing Security Gateway Multi-Homing Security Gateway MH-5000 Quick Installation Guide 1 Before You Begin It s best to use a computer with an Ethernet adapter for configuring the MH-5000. The default IP address for the MH-5000

More information

Using WhatsUp IP Address Manager 1.0

Using WhatsUp IP Address Manager 1.0 Using WhatsUp IP Address Manager 1.0 Contents Table of Contents Welcome to WhatsUp IP Address Manager Finding more information and updates... 1 Sending feedback... 2 Installing and Licensing IP Address

More information

Traffic monitoring with sflow and ProCurve Manager Plus

Traffic monitoring with sflow and ProCurve Manager Plus An HP ProCurve Networking Application Note Traffic monitoring with sflow and ProCurve Manager Plus Contents 1. Introduction... 3 2. Prerequisites... 3 3. Network diagram... 3 4. About the sflow protocol...

More information

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian. Problem: Patton / 240T WAN Setup Platform: NetGuardian 240T This TKP is a guide to setting up a PPP to T1 WAN connection between a Patton Model 2603 Router and a NetGuardian 240T. The example in this guide

More information

Chapter 3 Management. Remote Management

Chapter 3 Management. Remote Management Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described

More information

AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes

AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60

More information

enetworks TM BANDIT, C2C, and VSR-1200 Document Set List of Groups and Modules

enetworks TM BANDIT, C2C, and VSR-1200 Document Set List of Groups and Modules encor! enetworks TM Version A.4, January 2013 Document Part Number 16568.0000 2013 Encore Networks, Inc. All rights reserved. BANDIT, C2C, and VSR-1200 Document Set List of Groups and Modules The BANDIT,

More information

Know the signs of potential problems. Prevent problems before they occur. This unit contains the following three lessons:

Know the signs of potential problems. Prevent problems before they occur. This unit contains the following three lessons: Unit 6 Router Management Overview Description With today s networks growing exponentially, management is a key to quality of network performance. People depend on their networks and performance issues

More information

A message from Plixer International:

A message from Plixer International: Scrutinizer Getting Started Guide A message from Plixer International: Thank you for taking the time to download and install Scrutinizer. We believe that Scrutinizer is a useful tool for any Network industry

More information

DSL-G604T Install Guides

DSL-G604T Install Guides Internet connection with NAT...2 Internet connection with No NAT, IP Un-number...6 Port Forwarding...12 Filtering & Firewall Setup...20 Access Control... 21 DMZ Setup... 26 Allow Incoming Ping... 27 How

More information

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials. Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials. CHAPTER 5 OBJECTIVES Configure a router with an initial configuration. Use the

More information

Service Managed Gateway TM. How to Configure a T1/E1 Connection

Service Managed Gateway TM. How to Configure a T1/E1 Connection Service Managed Gateway TM How to Configure a T1/E1 Connection Issue 1.2 Date 26 August 2008 1 Introduction... 3 1.1 What is T1/E1 technology?... 3 2 Point-to-Point Protocol (PPP) connections... 4 2.1

More information

Tech Note Cisco IOS SNMP Traps Supported and How to Conf

Tech Note Cisco IOS SNMP Traps Supported and How to Conf Tech Note Cisco IOS SNMP Traps Supported and How to Conf Table of Contents Cisco IOS SNMP Traps Supported and How to Configure Them...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1

More information

Cisco Change Management: Best Practices White Paper

Cisco Change Management: Best Practices White Paper Table of Contents Change Management: Best Practices White Paper...1 Introduction...1 Critical Steps for Creating a Change Management Process...1 Planning for Change...1 Managing Change...1 High Level Process

More information

Wireshark Tutorial INTRODUCTION

Wireshark Tutorial INTRODUCTION Wireshark Tutorial INTRODUCTION The purpose of this document is to introduce the packet sniffer WIRESHARK. WIRESHARK would be used for the lab experiments. This document introduces the basic operation

More information

OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R

OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R OSBRiDGE 5XLi Configuration Manual Firmware 3.10R 1. Initial setup and configuration. OSBRiDGE 5XLi devices are configurable via WWW interface. Each device uses following default settings: IP Address:

More information

Applicazioni Telematiche

Applicazioni Telematiche Angelo Coiro Laboratorio Applicazioni Telematiche L emulatore Packet Tracer Packet Tracer Cisco Packet Tracer is an academic software that allows to emulate Cisco devices Packet Tracer can be used for

More information

Copyright 2006 Comcast Communications, Inc. All Rights Reserved.

Copyright 2006 Comcast Communications, Inc. All Rights Reserved. ii Copyright 2006 Comcast Communications, Inc. All Rights Reserved. Comcast is a registered trademark of Comcast Corporation. Comcast Business IP Gateway is a trademark of Comcast Corporation. The Comcast

More information

ProCurve Switch 1700-8 ProCurve Switch 1700-24

ProCurve Switch 1700-8 ProCurve Switch 1700-24 Management and Configuration Guide ProCurve Switch 1700-8 ProCurve Switch 1700-24 www.procurve.com ProCurve Series 1700 Switch Management and Configuration Guide Copyright 2007 Hewlett-Packard Development

More information

LifeSize Passport TM User and Administrator Guide

LifeSize Passport TM User and Administrator Guide LifeSize Passport TM User and Administrator Guide February 2011 LifeSize Passport User and Administrator Guide 2 LifeSize Passport This guide explains how to use and configure LifeSize Passport. For information

More information

TSX ETY 110 Module 8

TSX ETY 110 Module 8 Module 8 Introduction Subject of this chapter What s in this Chapter? This chapter describes the implementation of a TSX ETY 110 module. This chapter contains the following sections: Section Topic Page

More information

How to deploy console cable to connect WIAS-3200N and PC, to reset setting or check status via console

How to deploy console cable to connect WIAS-3200N and PC, to reset setting or check status via console System s web management can also be accesses via WAN port as long as the administrator uses an IP address listed in Management IP Address List setting. If both WAN and LAN ports are unable to reach web

More information

Chapter 15: Advanced Networks

Chapter 15: Advanced Networks Chapter 15: Advanced Networks IT Essentials: PC Hardware and Software v4.0 1 Determine a Network Topology A site survey is a physical inspection of the building that will help determine a basic logical

More information

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide Version 5.0 rev 1 Advantech Corp., Ltd. Table of Contents BwSNMP Advantech WebAccess to SNMP Agent (Simple

More information

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications PC/POLL SYSTEMS supports native TCP/IP polling for the SPS2000 cash register. It is recommended users have the register updated

More information

Chapter 8 Router and Network Management

Chapter 8 Router and Network Management Chapter 8 Router and Network Management This chapter describes how to use the network management features of your ProSafe Dual WAN Gigabit Firewall with SSL & IPsec VPN. These features can be found by

More information

P-660R-TxC Series. ADSL2+ Access Router. Quick Start Guide

P-660R-TxC Series. ADSL2+ Access Router. Quick Start Guide P-660R-TxC Series ADSL2+ Access Router Quick Start Guide Version 3.40 Edition 1 2/2006 Overview The P-660R-TxC ADSL2+ access router is the ideal device for small networks connecting to the Internet via

More information

School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management. Lab 4: Remote Monitoring (RMON) Operations

School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management. Lab 4: Remote Monitoring (RMON) Operations School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management Lab 4: Remote Monitoring (RMON) Operations Objective To become familiar with basic RMON operations, alarms,

More information

DSL-2600U. User Manual V 1.0

DSL-2600U. User Manual V 1.0 DSL-2600U User Manual V 1.0 CONTENTS 1. OVERVIEW...3 1.1 ABOUT ADSL...3 1.2 ABOUT ADSL2/2+...3 1.3 FEATURES...3 2 SPECIFICATION...4 2.1 INDICATOR AND INTERFACE...4 2.2 HARDWARE CONNECTION...4 2.3 LED STATUS

More information

Router Lab Reference Guide

Router Lab Reference Guide Router Lab Reference Guide 1 PURPOSE AND GOALS The routing lab allows testing different IP-related protocols and solutions in a close to live environment. You can learn how to configure Cisco routers and

More information

Smart Business Architecture for Midsize Networks Network Management Deployment Guide

Smart Business Architecture for Midsize Networks Network Management Deployment Guide Smart Business Architecture for Midsize Networks Network Management Deployment Guide Introduction: Smart Business Architecture for Mid-sized Networks, Network Management Deployment Guide With the Smart

More information

Module 1: Reviewing the Suite of TCP/IP Protocols

Module 1: Reviewing the Suite of TCP/IP Protocols Module 1: Reviewing the Suite of TCP/IP Protocols Contents Overview 1 Lesson: Overview of the OSI Model 2 Lesson: Overview of the TCP/IP Protocol Suite 7 Lesson: Viewing Frames Using Network Monitor 14

More information

Remote Access Server - Dial-Out User s Guide

Remote Access Server - Dial-Out User s Guide Remote Access Server - Dial-Out User s Guide 95-2345-05 Copyrights IBM is the registered trademark of International Business Machines Corporation. Microsoft, MS-DOS and Windows are registered trademarks

More information

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

CPEi 800/825 Series. User Manual. * Please see the Introduction Section CPEi 800/825 Series User Manual * Please see the Introduction Section Contents Introduction...iii Chapter 1: CPEi 800/825 User Guide Overview... 1-1 Powerful Features in a Single Unit... 1-2 Front of the

More information

Broadband Router ESG-103. User s Guide

Broadband Router ESG-103. User s Guide Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits

More information

ERserver. iseries. Remote Access Services: PPP connections

ERserver. iseries. Remote Access Services: PPP connections ERserver iseries Remote Access Services: PPP connections ERserver iseries Remote Access Services: PPP connections Copyright International Business Machines Corporation 1998, 2002. All rights reserved.

More information

WAN Failover Scenarios Using Digi Wireless WAN Routers

WAN Failover Scenarios Using Digi Wireless WAN Routers WAN Failover Scenarios Using Digi Wireless WAN Routers This document discusses several methods for using a Digi wireless WAN gateway to provide WAN failover for IP connections in conjunction with another

More information

Exploring the Remote Access Configuration Utility

Exploring the Remote Access Configuration Utility Exploring the Remote Access Configuration Utility in Ninth-Generation Dell PowerEdge Servers The Remote Access Configuration Utility supports local and remote server management in ninth-generation Dell

More information

Cisco NetFlow TM Briefing Paper. Release 2.2 Monday, 02 August 2004

Cisco NetFlow TM Briefing Paper. Release 2.2 Monday, 02 August 2004 Cisco NetFlow TM Briefing Paper Release 2.2 Monday, 02 August 2004 Contents EXECUTIVE SUMMARY...3 THE PROBLEM...3 THE TRADITIONAL SOLUTIONS...4 COMPARISON WITH OTHER TECHNIQUES...6 CISCO NETFLOW OVERVIEW...7

More information

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly

More information

Focal Point 2.1 Management Software & CPSMM100 Firmware Manual

Focal Point 2.1 Management Software & CPSMM100 Firmware Manual Focal Point 2.1 Management Software & CPSMM100 Firmware Manual Manual 33293 Rev B Focal Point Management Software Transition Networks Table of Contents Section I:...1 Introduction...1 About this manual...2

More information

Simple Network Management Protocol

Simple Network Management Protocol CHAPTER 4 This chapter gives an overview of (SNMP). It contains the following sections: Overview, page 4-1 SNMP Versioning, page 4-2 SNMP and Cisco Unified CM Basics, page 4-3 SNMP Basic Commands, page

More information

An Overview of SNMP on the IMG

An Overview of SNMP on the IMG An Overview of SNMP on the IMG Description SNMP The SNMP provides a way to control and monitor a variety of equipment using one network management protocol. To do this, SNMP uses a number of common Management

More information

*613-000734 Rev A* PN 613-000734 Rev A 1

*613-000734 Rev A* PN 613-000734 Rev A 1 AT-S70 Version 1.6.0 Management Software for the Converteon Media Converter Products Software Release Notes Please read this document before you begin to use the management software. Supported Platforms

More information

Basic Networking Concepts. 1. Introduction 2. Protocols 3. Protocol Layers 4. Network Interconnection/Internet

Basic Networking Concepts. 1. Introduction 2. Protocols 3. Protocol Layers 4. Network Interconnection/Internet Basic Networking Concepts 1. Introduction 2. Protocols 3. Protocol Layers 4. Network Interconnection/Internet 1 1. Introduction -A network can be defined as a group of computers and other devices connected

More information

Teldat Router. RADIUS Protocol

Teldat Router. RADIUS Protocol Teldat Router RADIUS Protocol Doc. DM733-I Rev. 10.70 June, 2007 INDEX Chapter 1 Introduction...1 1. Introduction to Radius Protocol... 2 1.1. Authentication and configuration for PPP connections... 2

More information

SSVP SIP School VoIP Professional Certification

SSVP SIP School VoIP Professional Certification SSVP SIP School VoIP Professional Certification Exam Objectives The SSVP exam is designed to test your skills and knowledge on the basics of Networking and Voice over IP. Everything that you need to cover

More information

Lecture (02) Networking Model (TCP/IP) Networking Standard (OSI) (I)

Lecture (02) Networking Model (TCP/IP) Networking Standard (OSI) (I) Lecture (02) Networking Model (TCP/IP) Networking Standard (OSI) (I) By: Dr. Ahmed ElShafee ١ Dr. Ahmed ElShafee, ACU : Fall 2015, Networks II Agenda Introduction to networking architecture Historical

More information

Chapter 4 Management. Viewing the Activity Log

Chapter 4 Management. Viewing the Activity Log Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in

More information

SNMP and Network Management

SNMP and Network Management SNMP and Network Management Nixu Oy Nixu Ltd PL 21 (Mäkelänkatu 91) 00601 Helsinki, Finland tel. +358 9 478 1011 fax. +358 9 478 1030 info@nixu.fi http://www.nixu.fi Contents Network Management MIB naming

More information

Fonality. Optimum Business Trunking and the Fonality Trixbox Pro IP PBX Standard Edition V4.1.2- p13 Configuration Guide

Fonality. Optimum Business Trunking and the Fonality Trixbox Pro IP PBX Standard Edition V4.1.2- p13 Configuration Guide Fonality Optimum Business Trunking and the Fonality Trixbox Pro IP PBX Standard Edition V4.1.2- p13 Configuration Guide Fonality Table of Contents 1. Overview 2. SIP Trunk Adaptor Set-up Instructions 3.

More information

CCT vs. CCENT Skill Set Comparison

CCT vs. CCENT Skill Set Comparison Operation of IP Data Networks Recognize the purpose and functions of various network devices such as Routers, Switches, Bridges and Hubs Select the components required to meet a given network specification

More information

Connect the Host to attach to Fast Ethernet switch port Fa0/2. Configure the host as shown in the topology diagram above.

Connect the Host to attach to Fast Ethernet switch port Fa0/2. Configure the host as shown in the topology diagram above. Lab 1.2.2 Capturing and Analyzing Network Traffic Host Name IP Address Fa0/0 Subnet Mask IP Address S0/0/0 Subnet Mask Default Gateway RouterA 172.17.0.1 255.255.0.0 192.168.1.1 (DCE) 255.255.255.0 N/A

More information