FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units



Similar documents
FCD-E1E Managed E1 and Fractional E1 Access Device

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

WEB RANger-II Internet Access Router

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

DXC Family. Multiservice Access Node FEATURES

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

Optimux-134, Optimux-125

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Optimux-34, Optimux-25

Optimux-134, Optimux-125

DXC-8R/10A/30 Multiservice Access Nodes

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

IPmux-1E TDM Pseudowire Access Gateway

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

TDMoEthernet. Description

Loop-IP6700 TDMoEthernet

Loop-IP6700 TDMoEthernet

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Loop-IP6702 TDMoEthernet

LA-110. Advanced Integrated Access Device FEATURES

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node

Chapter 4 T1 Interface Card

1. Overview. 2. F-bit Utilization

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

ORION TELECOM NETWORKS INC. T1

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

IPmux-155L Hub-Site Pseudowire Access Gateway

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

IPmux-16L Hub-Site Pseudowire Access Gateway

Cisco Channelized T1/E1 and ISDN PRI Modules

FOM-5A, 6A. Asynchronous Fiber Optic Modem

24-Port Channelized E1/T1 Line Card Overview

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

DataSMART 681, 696 and 698

Egate-100 Gigabit Ethernet over TDM Aggregation Gateway

Connecting Serial Interface Cards to a Network

OPERATION MANUAL INSTALLATION AND DXC-4. E1/T1 Grooming Device. Version 1.0. Innovative Access Solutions

Loop-IP6510 Multiple WAN Router/Bridge

G.703 Fractional T1 Access Unit. User Guide

IPmux-216 TDM Pseudowire Access Gateway

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

F2400 FOM II Series Fiber Optic Modem Technical Manual

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

VALIANT COMMUNICATIONS LIMITED

Octal T1-10/100 RIOP Installation Guide

ETX-204A Carrier Ethernet Demarcation Device

T3 Mux M13 Multiplexer

Optimux-XLT1. Multiple T1 and Ethernet Multiplexer Installation and Operation Manual. Notice

Configuring E1 and T1 Interfaces

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

TrueAlarm Fire Alarm Systems

Airmux-200 Wireless Broadband Multiplexer

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet

cpci cfxo3120 FXO/FXS VoIP Gateway

Configuring E1 and T1 Interfaces

Chapter 2 - The TCP/IP and OSI Networking Models

Cable Specifications. T3 Trunk Cabling APPENDIX

BTM10 Series Transmission Analyzer

Appendix A QUICK Specifications

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Long Range Ethernet Extender

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

RADview/TDM. Element Management System for TDM Applications Optimux-T RAD Data Communications Publication 06/05

TDM-over-IP Improving Backhaul efficiency

Appendix D T1 Overview

! encor en etworks TM

CERAGON. Broadband Wireless Network Solutions GHz Mbps SONET/SDH IP ATM Fast Ethernet Built-in ADM

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

FarSync T2Ue. A 2 port PCI Express synchronous communications adapter

One Port Serial Server Users Manual Model ESP901, ESP901E

3500/22M Transient Data Interface

Cable Pinouts. SRP I/O Module

Cisco Third-Generation 1-, 2-, and 4-Port T1/E1 Multiflex Trunk Voice/WAN Interface Cards

Product Overview. Features CHAPTER

NetVanta 3000 Series (with T1/FT1 or T1/FT1 with DSX-1 Network Interface Module)

Cisco 2-Port and 4-Port Channelized T3 (DS-0) Shared Port Adapters

SHDSL LAN EXTENDER H301A. User Manual

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

SRX 210 Services Gateway T1/E1 Mini-Physical Interface Module

Adtech Data Link Simulators.

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Starlink 9003T1 T1/E1 Dig i tal Trans mis sion Sys tem

Transcription:

Where to buy > See the product page > Data Sheet FCD-E1LC, FCD-T1LC Managed TDM multiplexers for access to full or fractional E1/T1 services Managed access units for E1/T1 or fractional E1/T1 service E1/T1 main link and sublink support framed and unframed signals One or two data ports with selectable sync data rates: n 56 kbps or n 64 bps Serial data port interfaces: V.24, V.35, V.36/RS-449, RS-530, or X.21 Optional sub-e1/t1 drop-and-insert port for PBX connectivity Optional Ethernet 10/100BaseT bridge with VLAN support, or V.24 serial interface (second user port) FCD-E1LC and FCD-T1LC are managed access units that convert rates and interfaces for full or fractional E1/T1 services. These units support a single or dual serial n 56 kbps or n 64 kbps data user interface. The second serial data interface port can be replaced by an Ethernet LAN interface to allow LAN-to-LAN connectivity over TDM media. The FCD-E1LC and FCD-T1LC units interconnect with RAD modular DXC, Megaplex products and E1/T1 equipment from other vendors to support multilink star applications such as access to SDH networks. All these products DXC, FCD, and Megaplex operate together under centralized SNMP network management. The Access Company

FCD-E1LC, FCD-T1LC The E1 interface is compatible with virtually all carrier-provided E1 services and meets ITU recommendations G.703, G.704, G.706, G.732, G.823, and G.826. It supports both 2 and 16 frames per multiframe, with or without CRC-4. The E1 interface also accepts a 2048 kbps data stream and converts it to an ITU-T Rec. G.703 unframed signal for transport over the E1 main link and sublink. Line code is HDB3. The integral LTU ensures a range of up to 2 km (1.2 miles) and is software-selectable. The T1 interface is compatible with virtually all carrier-provided T1 services, including ASDS from AT&T. It complies with TR-62411 and TR-62421 and supports D4 and ESF framing formats. Zero suppression over the line is software-selectable for either transparent, B7ZS or B8ZS. The software-selectable integral CSU ensures a range of up to 2.1 km (1.3 miles). The optional sub-e1 port can be configured to work without CRC-4, while the E1 main link is working with CRC-4. This enables connection of E1 equipment not supporting CRC-4, over an E1 network that is working with CRC-4. The optional sub-t1 port can be configured with D4 or ESF framing, while the T1 main link framing is ESF. This enables connection of T1 D4 equipment over an ESF T1 network. The FCD-E1LC and FCD-T1LC units can be programmed to assign data automatically from each data port into consecutive timeslots. The user can also assign timeslots manually. Timing for the E1/T1 main link and sublink may come from the recovered receive clock, an internal oscillator, or one of the data ports. This multiple clock source selection ensures maximum flexibility for supporting different applications. Front panel LEDs indicate alarms, E1/T1 signal loss, and diagnostic loopback operation. Rear panel LEDs on the Ethernet interface modules indicate LAN status and activity. FCD-E1LC and FCD-T1LC are compact standalone units. A rack mount adapter kit enables installation of one or two (sideby-side) units in a 19-inch rack.

USER INTERFACES The FCD-E1LC and FCD-T1LC units feature the following user interfaces: Serial data interfaces: V.24, V.35, V.36/RS-449, RS-530, X.21 Ethernet 10/100BaseT LAN interface module with a built-in bridge (IR-ETH/QN). The synchronous data ports of FCD-E1LC operate in the following clock modes: DCE: The FCD units provide both transmit and receive clocks to the user equipment, with optional sampling of the incoming data with an inverted clock DTE1: The FCD units provide the transmit clock, while the transmit clock is provided by the attached user equipment DTE2: The attached user equipment provides both transmit and receive clocks. The IR-ETH/QN interface module has a 10/100BaseT interface that supports VLAN frames, autonegotiation, fault propagation, and automatic learning and aging. The module transparently connects FCD-E1LC and FCD-T1LC to remote LANs over E1/T1 links. It filters Ethernet frames and forwards only frames that are destined for the WAN. MANAGEMENT & MAINTENANCE Status and diagnostic information is defined, configured, and monitored using one of the following methods: ASCII terminal connected to the async control port SNMP management Telnet. All models support an internal SNMP agent that is managed by any generic SNMP station or by the RADview SNMP-based management application. FCD-E1LC and FCD-T1LC support both dial-in and dial-out modem connections through the serial RS-232 port, by using SLIP or PPP protocol or a command line interpreter on an ASCII terminal. These out-of-band connections can be used for remote configuration and monitoring, as well as for sending callout alarm messages. Up to 100 time-stamped alarms are available for retrieval through the supervision terminal, a Telnet host, or a RADview management station. Inband management can be performed either by dedicated timeslot using standard Frame Relay protocol (RFC 1490), or by using the spare S a bits on timeslot 0 for FCD-E1LC or FDL bits for FCD-T1LC. This allows the user to setup, monitor, and run diagnostics on the remote unit. The spare bits on TS0 or FDL that are used for inband access must be passed transparently end-to-end. Maintenance capabilities include user-activated local and remote loopbacks on the E1/T1 main link, sublink, and data ports. The user can activate a BER test on the main link. Also, the main link responds to an ANSI FT1 RDL (T1.403) inband loop code, or a user-configured pattern generated by a remote FCD-E1LC, FCD-T1LC, or DXC in a specific bundle of timeslots allocated only to that port. The user can also define BER or inband tests to run on any timeslot of the main link. E1 network statistics are stored in memory, according to RFC 1406. Statistical information can be retrieved locally through the control port. T1 network statistics are stored in memory, according to ANSI and AT&T standards. The statistical information may be retrieved by the service provider (ANSI only) or locally through the control port.

FCD-E1LC, FCD-T1LC Figure 1. Extended Ethernet Management over E1/T1 Network

Specifications E1 MAIN LINK AND SUBLINK Framing 256N (no MF, CCS) 256N (no MF, CCS) with CRC-4 256S (TS16 MF, CAS) 256S (TS16 MF, CAS) with CRC-4 Unframed Bit Rate 2.048 Mbps Line Code AMI Zero Suppression HDB3 Line Impedance 120Ω, balanced 75Ω, unbalanced Transmit Timing Locked to the system clock Signal Level Receive: 0 to 10 db without LTU 0 to 36 db with LTU Transmit: ±3V (±10%), balanced ±2.37V (±10%), unbalanced Jitter Performance As per ITU G.823, ETSI TBR-12 and TBR-13 Connectors RJ-45, 8-pin, balanced Two BNC coaxial, unbalanced, using adapter cable Compliance ITU G.703, G.704, G.706, G.732, G.823, G.826 Performance Monitoring Local support of CRC-4 Full statistical diagnostics according to RFC-1406 T1 MAIN LINK AND SUBLINK Framing D4 ESF Unframed (main link only) Bit Rate 1.544 Mbps Line Code AMI Zero Suppression Transparent, B7ZS, B8ZS Line Impedance 100Ω, balanced Transmit Timing Locked to the system clock Signal Level Receive: 0 to 10 db without CSU 0 to 36 db with CSU Transmit: 7.5, 15, 22.5 db with CSU ±3V, ±10% soft adjustable at 0 to 655 ft without CSU T1 Jitter Performance As per AT&T TR-62411 Connector RJ-45, 8-pin, balanced Compliance AT&T TR-62411, AT&T 54016, AT&T TR-62421, ANSI T1.403 Performance Monitoring Local support of ESF diagnostics according to AT&T PUB 54016 Full statistical diagnostics according to ANSI T1.403-198 DATA PORTS Connectors D-type, 25-pin, RS-530, female (converted via adapter cables to V.35, X.21, V.36/RS-449) Additional connectors for second user port: D-type, 25-pin, female for V.24, RJ-45 for ETH Data Rate n 56/64 kbps (n=1 to 24) for T1 n 64 kbps (n=1 to 31) for E1 n 64 kbps (n=1 to 2) for V.24 port Clock Modes DCE: Rx and Tx clock to user device DTE1: Rx clock to user device; Tx clock from user device (not for X.21 and V.24) DTE2: Rx and Tx clock from user device (not for X.21 and V.24) Control Signals CTS follows RTS or constantly ON, softselectable DSR constantly ON, unless in test mode DCD constantly ON, unless in sync loss

Data Sheet ETHERNET BRIDGE PORT Interface and Connector 10/100BaseT (UTP) with shielded RJ-45 Maximum Frame Length 1536 bytes LAN Table 2048 MAC addresses Throughput 4,000 pps Latency 300 μsec (64-byte frame size, 2M LAN rate) Buffer 120 frames Line Code 10BaseT: Manchester 100BaseT: MLT3 WAN Protocol HDLC DIAGNOSTICS Main E1/T1 link Local loopback Remote loopback BER test Code-activated inband loopback per data port Code-activated T1 network loopback (FCD-T1LC only) Sublink Local loopback Remote loopback Code-activated T1 network loopback (FCD-T1LC only) Data Port Local loopback Remote loopback GENERAL System Clock Internal clock: ±50 ppm Loopback timing: ±130 ppm External timing from data port: ±130 ppm Management Port Interface: RS-232, 9-pin D-type, female Format: asynchronous Baud rate: 1.2 115.2 kbps, autobaud Character: 8-bit no parity, 7-bit odd or even parity Timeslot Allocation Consecutive (bundled) User-defined Indicators General: PWR (green), TST (yellow), ALM (red) Main/sub-E1: LOC SYNC LOSS (red), REM SYNC LOSS (red) Main/sub-T1: RED ALARM (red), YEL ALARM (yellow) Physical Height: 4.4 cm (1.7 in) Width: 21.7 cm (8.5 in) Depth: 17.0 cm (6.7 in) Weight: 0.8 kg (1.8 lb) Power AC/DC: 100 to 240 VAC, -48 to -60 VDC, nominal Power consumption: 5W max. Environment Temperature: 0 C to 50 C (32 F to 122 F) Humidity: Up to 90%, non condensing

FCD-E1LC, FCD-T1LC Table 1. FCD Comparison Table Features FCD-E1 FCD-E1L FCD-E1LC/T1LC FCD-E1E FCD-E1A Total user ports 3 2 3 2 3 Interface types RS-530, V.35, RS-530, V.35, V.36, RS-530, V.24, V.35, RS-530, V.35, RS-530, V.35, V.36, X.21, Sub-E1 X.21, Ethernet bridge V.36, X.21, Ethernet Bridge (10/100BaseT V.36/RS-449, X.21, V.24/RS-232, Ethernet V.36/RS-449, X.21, Sub-E1 (10/100BaseT with VLAN support) with VLAN support), Sub-E1/T1 Bridge (10/100BaseT with VLAN support), Sub-E1 E1/T1 line type Copper Copper Copper Copper Copper LCD panel Auto-configuration SNMP management Interoperability Megaplex, DXC Megaplex, DXC Megaplex, DXC Megaplex, DXC Megaplex, DXC ETH out-of-band for management E1 bypass ETH performance VLAN transparent VLAN transparent VLAN priority tagging (802.1p/Q) VLAN transparent

FCD-E1LC, FCD-T1LC Data Sheet Ordering STANDARD CONFIGURATIONS FCD-E1LC/X21/ETQN FCD-E1LC/X21/S/ETQN FCD-E1LC/V35/S/ETQN FCD-E1LC/X21 FCD-E1LC/V35 FCD-T1LC/X21/S FCD-T1LC/530/530 FCD-T1LC/V35/ETQN FCD-T1LC/530 FCD-T1LC/V35 SPECIAL CONFIGURATIONS FCD-E1LC/&/*/% E1 or fractional E1 access unit FCD-T1LC/&/*/% T1 or fractional T1 access unit Legend & Data port interface: 530 RS-530 V35 V.35 X21 X.21 V36 V.36/RS-449 * S Optional drop-and-insert E1/T1 sublink % Optional second data port interface: 530 RS-530 V35 V.35 X21 X.21 V36 V.36/RS-449 V24 for V.24 ETQN 10/100BaseT Ethernet bridge with VLAN support SUPPLIED ACCESSORIES Power cord and AC/DC adaptor plug The following cables are supplied for each data port interface specified for operating in DCE clock mode: CBL-HS2/V/1 for 34-pin V.35 CBL-HS2/R/1 for 37-pin V.36/RS-449 CBL-HS2/X/1 for 15-pin X.21 OPTIONAL ACCESSORIES RM-33-2 Hardware for mounting one or two units in a 19-inch rack CBL-DB9F-DB9M-STR Control port cable CBL-RJ45/2BNC/E1/X RJ-45 to BNC adaptor cable (for unbalanced main link interface) CBL-RJ45/2BNC/E1 RJ-45 to BNC adaptor cable (for unbalanced sublink interface) CBL-HS2/*/# Adaptor cables for DB-25 channel connectors, for operation in the DTE1 and DTE2 clock modes Legend * Interface, clock mode: V/2 34-pin V.35, DTE1 V/3 34-pin V.35, DTE2 R/2 37-pin V.36/RS-449, DTE1 R/3 37-pin V.36/RS-449, DTE2 # Cable connector type F female M male 389-100-06/11 (1.0) Specifications are subject to change without prior notice. 1991 2011 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders. International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@radusa.com www.rad.com Order this publication by Catalog No. 803532 The Access Company