McAfee Data Loss Prevention



Similar documents
McAfee Firewall Enterprise

McAfee Firewall Enterprise

DD670, DD860, and DD890 Hardware Overview

Five9NS R2100RS Rack Mount Server. Installation Manual

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

How to Set Up Your NSM4000 Appliance

HQP-1072 Series System User Guide

System Release Notes Express5800/320LB System Release Notes

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

HP UPS R1500 Generation 3

Infinity C Reference Guide

CM500 High Speed Cable Modem User Manual

Beckhoff onboard SATA-RAID

StorTrends 3400 Hardware Guide for Onsite Support

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Cisco NAC Appliance Hardware Platforms

ReadyNAS OS 6 Desktop Storage Systems

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

esata 6G RAID PCIe 2.0 Controller Card

Ethernet Radio Configuration Guide

Using RAID Admin and Disk Utility

Wireless Router Setup Manual

MCR1900 Media Converter 19-Slot Chassis

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

CM400 High Speed Cable Modem User Manual

Cisco Expressway CE500 Appliance

RSA Security Analytics. S4 Broker Setup Guide

Ultra Thin Client TC-401 TC-402. Users s Guide

TL-PS310U Single USB 2.0 Port MFP and Storage Server

FUSION R400 RAID USB 3.0

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

HP StoreVirtual 4630 Storage Maintenance Guide

Energy Communication Unit (ECU)

Backup & Disaster Recovery Appliance User Guide

HP R12000 and R18000 DirectFlow UPS User Guide

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

DF to-2 SATA II RAID Box

Installation Guide Revision A. McAfee Web Gateway 7.4.0

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Disclaimers. Important Notice

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

Thank for choosing the Dominion KX III, the industry's highest performance enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch.

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

System Area Manager. Remote Management

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

Intel Server System P4000RP Family Service Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products

ESATA PCI CARD. User s Manual

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

EVGA Z97 Classified Specs and Initial Installation (Part 1)

Using GIGABYTE Notebook for the First Time

Gigabyte Content Management System Console User s Guide. Version: 0.1

Cisco Physical Security Multiservices Platform Series User Guide

NETFORT LANGUARDIAN INSTALLING LANGUARDIAN ON MICROSOFT HYPER V

Energy Communication Unit (ECU)

Using GIGABYTE Notebook for the First Time

DD160 and DD620 Hardware Overview

TimeIPS Server. IPS256T Virtual Machine. Installation Guide

ICMP HDD. Installation manual

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400

Maintaining the Content Server

ReadyNAS Duo and NV+

Deploying Microsoft RemoteFX on a Single Remote Desktop Virtualization Host Server Step-by-Step Guide

Network Management Card. Installation and Quick Start Manual

Dotworkz NVR Series User Manual. Rev 1.26

LaCie 12big Rack Network

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

AlienVault. Unified Security Management (USM) x Initial Setup Guide

Welcome. Unleash Your Phone

Sample of Hardware Equipment Acceptance Form

Guardian MAXimus ASSEMBLY MANUAL & USER GUIDE

Network Management Card

System Event Log Troubleshooting Guide for Intel S5500/S3420 Series Server Boards

BroadBand PowerShield. User Manual

Cisco MCS 7845-I2 Unified Communications Manager Appliance

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

Using GIGABYTE Notebook for the First Time

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

FW-310. Appliance Installation Guide

esata External Storage

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

RocketStor SMART RAID

Hardware Guide CYBERSECURITY, EVOLVED V8.0. EdgeWave iprism Web Security. For more info, visit us at:

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

2» 10» 18» 26» PD »

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Installation Manual

NETGEAR ReadyNAS OS 6 Rack-Mount Storage Systems

1. Specifiers may alternately wish to include this specification in the following sections:

350 East Plumeria Drive San Jose, CA USA March

iosafe Quick Start Guide Powered by Synology DSM

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

System x3650 Type 7979

User Manual. EtherUSB

TD-8610/TD-8610B External ADSL2+ MODEM

QNAP RAID Expansion Enclosure Hardware User Manual QNAP Systems, Inc. All Rights Reserved.

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Transcription:

Hardware Guide Revision B McAfee Data Loss Prevention 1650, 3650, 4400, 5500 This guide describes the features and capabilities of McAfee Data Loss Prevention (McAfee DLP) appliances to help you to manage and maintain them. For information on running and installing McAfee DLP in a virtual environment, see the McAfee Data Loss Prevention Virtual Installation Guide. About the appliances McAfee DLP software runs on these appliance models. 1650 3650 4400 5500 Supported software versions McAfee DLP appliances support these software versions. 9.0.x 9.2.x 9.3.x 1

Models and features The table shows the McAfee DLP models and features. Table 1 Model features Model Number of hard drives Capture database capacity RAM Remote Management Module (RMM) 1650 4 500 GB 16 GB No 1U 3650 16 4 TB 16 GB No 3U 4400 12 7.2 TB 24 GB Yes 2U 5500 8 9 TB 32 GB Yes 2U Rack height Model 1650 The model 1650 appliance ships on a Supermicro X7DBU system board. Back panel hardware components The illustration identifies the hardware components on the back panel of the appliance. Figure 1 1650 back panel 1 Power supplies 5 VGA port 2 PS2 ports 6 Management port 3 USB ports 7 Capture port 0 4 Serial port 8 Capture port 1 Front control panel The control panel is on the front of the chassis. Figure 2 1650 front control panel 1 System ID button 5 Hard drive activity 2 System overheat/fan failure 6 System power 3 NIC 2 activity 7 Reset button 4 NIC 1 activity 8 Power button 2

Model 3650 The model 3650 appliance ships on a Supermicro X7DBU system board. Back panel hardware components The illustration identifies the hardware components on the back panel of the appliance. Figure 3 3650 back panel 1 Power supplies 5 VGA port 2 PS2 ports 6 Management port 3 USB ports 7 Capture port 0 4 Serial port 8 Capture port 1 Front control panel The control panel is on the front of the chassis. Figure 4 3650 front control panel 1 System power failure 5 Hard drive activity 2 System overheat/fan failure 6 System power 3 NIC 2 activity 7 Reset button 4 NIC 1 activity 8 Power button 3

Model 4400 The model 4400 appliance ships on an Intel Server System SR2612UR. For more information on the Intel Server System SR2612UR, see the Intel documentation. Intel Server System SR2612UR Technical Product Specification: http://download.intel.com/support/motherboards/server/s5520ur/sb/sr2612ur_tps_13.pdf Intel Server System SR2612UR Service Guide: http://download.intel.com/support/motherboards/server/s5520ur/sb/ r2612ur_service_guide_14.pdf Back panel hardware components The illustration identifies the hardware components on the back panel of the appliance. Figure 5 4400 back panel 1 VGA port 5 Capture port 0 2 USB ports 6 Capture port 1 3 Management port 7 Power supplies 4 Remote access port (RMM) On some 4400 models, the capture ports might be on a slotted NIC instead of on the motherboard. In this case, the capture port numbers are swapped. Front control panel The control panel is on the front of the chassis. Figure 6 4400 front control panel 1 Power supply + 12V OK 2 Enclosure services subsystem fault 3 System status 4 System identify 4

Table 2 4400 indicator light states Indicator light Power supply + 12V OK Enclosure services subsystem fault System identify Description Off Initial state Green +12V output is enabled for a power supply Off Initial state Amber Enclosure Service Processor on the midplane detects a failure condition Off Initial state Blue System identify is enabled by server system management software Table 3 4400 system status indicator light states Color State Status Green Solid System booted and ready Blink System degraded: Non-critical threshold crossed: Temperature Voltage Fan redundancy lost, sufficient system cooling maintained Power supply redundancy lost Unable to use all of the installed memory one or more DIMMS failed or disabled, but functional memory remains available Correctable errors over a threshold of 10 and migrating to a spare DIMM (memory sparing) Memory mirroring takes place and the system loses memory redundancy PCI Express link errors CPU failed or disabled Amber Solid Fatal alarm System has failed or shut down: CPU 1 missing CPU configuration error IERR signal asserted Power fault DIMM failure when only one DIMM is present Runtime memory uncorrectable error in non-redundant mode Critical temperature threshold crossed 5

Table 3 4400 system status indicator light states (continued) Color State Status Blink Non-fatal alarm System is likely to fail: Critical voltage threshold crossed VRD hot asserted Minimum number of fans to cool the system not present or failed Memory threshold of ten correctable errors crossed within the window in non-sparing and non-mirroring mode Off Off System powered off Power supply indicator lights Each installed power supply module has a single indicator light to show the power supply status. Table 4 4400 power supply indicator light states Color State Status Green Solid Output ON and OK Blink AC present / Only 5 VSB on (Power supply off) Amber Solid No AC power to this power supply unit only (for 1+1 configuration) Power supply critical event causing a shutdown: Failure OVP Fuse blown (for 1+1 configuration) Fan failed OCP Blink Power supply warning events where the power supply continues to operate: High temperature High power High current Slow fan Off Off No AC power to all power supplies Model 5500 The model 5500 appliance ships on an Intel Server System R2312GZ. For more information on the Intel Server System R2312GZ, see the Intel documentation. Intel Server System R2000GZ/GL Product Family Technical Product Specification: http://download.intel.com/support/motherboards/server/sb/r2000gzgl_tps_r2_2.pdf Intel Server System R2000GZ/GL Family Service Guide: http://download.intel.com/support/motherboards/server/sb/r2000gzgl_serviceguide.pdf Intel Server System R2000GZ/GL Product Family Quick Installation User's Guide: http://download.intel.com/support/motherboards/server/r2000gz-gl/sb/r2000gz_gl_qig.pdf 6

Back panel hardware components The illustration identifies the hardware components on the back panel of the appliance. Figure 7 5500 back panel 1 Capture port 1 5 VGA port 2 Capture port 0 6 Serial port 3 Power supplies 7 USB ports 4 Management port 8 Remote access port (RMM) Front control panel The control panel is on the front of the chassis. Figure 8 5500 front control panel 1 Power button 6 NIC 2 activity 2 System status 7 NIC 4 activity 3 Hard drive activity 8 NIC 1 activity 4 System ID button 9 NIC 3 activity 5 System cold reset button 10NMI button (recessed) NICs 1, 3, and 4 are not used by the McAfee DLP appliance. 7

Table 5 5500 system status indicator light states Color State Status Green Solid System booted and ready Blink System degraded: Non-critical threshold crossed: Temperature Voltage Power supply input or output Fan redundancy lost, sufficient system cooling maintained Power supply redundancy lost Unable to use all of the installed memory one or more DIMMS failed or disabled, but functional memory remains available Correctable errors over a threshold and migrating to a spare DIMM (memory sparing) Uncorrectable memory error in Mirroring Mode Correctable memory error threshold reached for failing DDR3 DIMM when the system operates in RAS Mirroring Mode Battery failure Power unit sensor offset error asserted HDD HSC offline or degraded BMC executing uboot BMC Watchdog has reset the BMC 8

Table 5 5500 system status indicator light states (continued) Color Amber Solid State Status Fatal alarm System has failed or shut down: CPU CATERR signal asserted CPU 1 missing CPU Thermal Trip CPU ERR2 signal asserted MSID mismatch detected DIMM failure when only one DIMM is present Runtime memory uncorrectable error in non-redundant mode DIMM Thermal Trip or equivalent SSB Thermal Trip or equivalent BMC/Video memory test failed Both uboot BMC FW images are bad 240VA fault Power fault Fatal error in processor initialization: Processor families not identical Processor models not identical Processor core/thread counts not identical Processor cache sizes not identical Unable to synchronize processor frequency Unable to synchronize QPI link frequency Blink Non-fatal alarm System is likely to fail: Critical threshold crossed: Temperature Voltage Power supply input or output VRD hot asserted Minimum number of fans to cool the system not present or failed Hard drive fault Insufficient power supplies present Correctable memory error threshold crossed for a failing DDR3 DIMM when the system operates in a non-redundant mode Off Off System powered off 9

Power supply indicator lights Each installed power supply module has a single indicator light to show the power supply status. Table 6 5500 power supply indicator light states Color State Status Green Solid Output ON and OK 1 Hz Blink AC present / Only 12VSB on (power supply off) or power supply in cold redundant state 2 Hz Blink Power supply FW updating Amber Solid AC cord unplugged or AC power lost when a second parallel power supply still has AC input power Power supply critical event causing a shutdown: Failure OCP OVP Fan failed Blink Power supply warning events where the power supply continues to operate: High temperature High power High current Slow fan Off Off No AC power to all power supplies Replacing hardware components McAfee DLP appliances ship with replaceable hard drives and power supplies. Replace the hard drive Each McAfee DLP appliance uses hot-swappable hard drives connected to a RAID controller. The RAID controller allows the system to continue operating if a single disk drive fails. A single failed hard drive can be replaced while the system is still operational. Before you begin The replacement hard drive must be the same capacity as the failed hard drive. Task 1 Identify the failed hard drive. A failed hard drive typically has an amber indicator light. 2 Remove the failed hard drive from the appliance. a b Press the latch on the failed hard drive to release the spring-loaded handle. Pull on the handle to remove the failed hard drive from the appliance. 10

3 On the replacement hard drive, press the latch to release the spring-loaded handle. 4 Insert the replacement hard drive into the appliance. a Slide the drive into the empty hard drive bay until it is fully seated. b c Press the handle until it latches. If the appliance is turned off, turn it on. After the drive is inserted, the RAID controller begins the rebuild operation. Do not turn off the appliance until the rebuild operation is complete. Performance is reduced while the rebuild operation takes place. Replace the power supply Each model has dual power supplies that allow the appliance to continue operating if one power supply fails. The power supplies are hot-swappable, so a single power supply can be replaced while the system is still operating. Before you begin Verify that the replacement power supply is compatible with your appliance model. A power supply can be replaced while the appliance is turned on and running or when the appliance is turned off. Use both power supplies in normal operation so that two power supplies share the load. Task 1 Disconnect the power cord from the failed power supply. 2 Unlatch the handle and remove the failed power supply. 3 Slide the replacement power supply into the appliance until it is fully seated and the latch has engaged. 4 Connect the power cord to the replacement power supply. Diagnosing hardware problems McAfee DLP appliance shipments include the Intel Diagnostic Tool (IDT). For information on performing hardware diagnostics using the supplied IDT, see KnowledgeBase article PD24396. 11

Re-imaging an appliance Re-imaging an appliance restores the drives to their pre-installed state. Re-imaging a model 1650 or 3650 Contact technical support for assistance on re-imaging a model 1650 or 3650. Re-image a model 4400 or 5500 using the RMM Use the RMM to re-image the appliance. Before you begin Using an Ethernet cable, connect the RMM port to your network. Decide the IP address, subnet mask, and gateway IP address to use when configuring the RMM port. Make sure Java is installed on the computer that connects to the RMM. Task 1 Download the McAfee DLP Manager.iso image file to the computer that connects to the RMM. a Locate the grant number you received after purchasing the product. b c d In a web browser, go to www.mcafee.com/us/downloads. Enter your grant number, then select the appropriate product and version. In the Software Downloads tab, select and save the appropriate *.iso file. 2 Restart the appliance. 3 Press F2 before the operating system boots to enter the BIOS. 4 Select Server Management BMC LAN Configuration. 5 Configure these items: Intel(R) RMM4 IPv4 LAN Configuration IP Source Enter the IP address, subnet mask, and gateway IP address for the RMM port. User ID Select root. User Status Select Enabled. User name Enter root. User password Enter mcafee. You must enter this password twice. 6 Confirm the network and user information, and press F10 to save and exit the BIOS. The appliance boots with the new settings. 7 On the computer that connects to the RMM, open a web browser and enter: http://x.x.x.x x.x.x.x is the IP address of the RMM port. The credentials are root/mcafee. 12

8 Select the.iso file and re-image. a On the Remote Control tab, click Launch Console. b c d e On the Device tab, select Redirect ISO and browse to the.iso file. On the Remote Control tab, select Server Power Control Power Cycle Server. The appliance re-images using the.iso file. Click Launch Console. On the Device tab, disable Redirect ISO. If you do not disable the Redirect ISO setting, the appliance will re-image after the next reboot, removing your current installation and returning the appliance to factory default. Re-image a model 4400 using the DVD Use the DVD that shipped with the appliance to re-image a model 4400. Task 1 Insert the DVD into the appliance. 2 Using a command line session, log on to the appliance as root. 3 Restart the system. # reboot The system restarts and re-images the drives. 4 After the restore completes, remove the DVD. If you do not remove the DVD, the appliance will re-image from the DVD after the next reboot, removing your current installation and returning the appliance to factory default. Re-image a model 5500 using the USB drive Use the USB drive included in the appliance shipment to re-image the appliance. Task 1 Connect the USB drive to one of the USB ports on the appliance. 2 Restart the appliance. 3 Press F2 before the operating system boots to enter the BIOS. 4 Select Boot from USB device. 5 Press F10 to save and exit. 6 Follow the on-screen instructions to re-image from the USB drive. 7 After the re-image finishes, remove the USB drive. If you do not remove the USB drive, the appliance will re-image from the USB drive after the next reboot, removing your current installation and returning the appliance to factory default. 13

Technical specifications McAfee DLP appliances meet all safety and operational standards and are in compliance with FCC standards. McAfee DLP rack mounting requirements McAfee DLP hardware must be rack mounted properly to ensure safe configuration. This checklist provides requirements for installing McAfee DLP hardware in a rack. Elevated operating ambient temperature If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment might be greater than room ambient. Consider installing the equipment in an environment compatible with the maximum ambient temperature (MAT) specified by the manufacturer. Reduced air flow When installing the equipment in a rack, do not compromise the amount of air flow required for safe operation. Mechanical loading When mounting the equipment, make sure no hazardous conditions are created due to uneven mechanical loading. Circuit overloading When connecting the equipment to the supply circuit, consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Use appropriate consideration of equipment nameplate ratings when addressing this concern. Reliable earthing Maintain reliable earthing of rack-mounted equipment. Give particular attention to supply connections that are not directly connected to the branch circuit, such as power strips. McAfee DLP power redundancy McAfee DLP appliances with more than one power supply must be configured to provide redundancy by sharing the load while operating at nominal power. Additional protection is provided if two electrical outlets that are on different circuit breakers are used. If one power supply fails, a backup fan automatically turns on, an alarm sounds, and a warning LED illuminates. If a power supply fails, contact McAfee for a replacement unit. If a McAfee DLP appliance loses power for any reason, the appliance will not come back up unless you change the BIOS setting in advance. The motherboard is set to off by default. McAfee DLP FCC compliance McAfee DLP hardware has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 16 of the Federal Communications Commission rules. Any modifications to McAfee DLP equipment, unless expressly approved by the party responsible for compliance, could void authority to operate the equipment. Operation of the McAfee DLP appliances is subject to the following conditions: The device might cause harmful interference, and The device must accept any interference received, including interference that might cause unwanted operation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. 14

McAfee DLP equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, it might cause harmful interference to radio communications. If operation of this equipment in a residential area causes harmful interference, it must be corrected at owner expense. McAfee DLP safety compliance guidelines McAfee DLP appliances must be operated in compliance within strict safety guidelines. McAfee DLP hardware must be installed only in Restricted Access locations, such as dedicated equipment rooms or electrical closets. Disconnect all power supply cords before servicing. There is a RISK OF EXPLOSION if a battery is replaced by an incorrect type. Dispose of used batteries according to industry standards. Copyright 2015 McAfee, Inc. www.intelsecurity.com Intel and the Intel logo are trademarks/registered trademarks of Intel Corporation. McAfee and the McAfee logo are trademarks/ registered trademarks of McAfee, Inc. Other names and brands may be claimed as the property of others. B00 15