Scully ST-47C Groundhog

Similar documents
Operating Instructions

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Advantium 2 Plus Alarm

MCR1900 Media Converter 19-Slot Chassis

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

INSTALLATION INSTRUCTIONS

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

WE-350 Series ¼ Turn Electric Actuator

2 & 5-Wire Overfill Sensors

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Floodlight Range Installation Guide

Industrial Ringdown/Autodialer Telephone SCR Series

LIEBERT VNSA Installation Sheet

Explosion proof enclosures

Operating Instructions

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Single Station Remote Alarm

INFRARED QUARTZ WALL HEATER

Model 201 Wiegand Touchpad Reader Installation Guide

Manual for Fire Suppression & Methane Detection System

ATS Overhead Table Shelf System INSTRUCTION MANUAL

PART 1 - INTRODUCTION...

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

, User s Manual

Toroidal Conductivity Sensor

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

RAY-MAX Integrated Solar Power Strip

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Installation and Operation Guide for PD4000 Series Power Control Center

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

HP UPS R1500 Generation 3

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Operating Instructions

MIC-WKT and MIC-WKT-IR

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

12 Volt 30 Amp Digital Solar Charge Controller

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Instructions for Safe Use

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

SMD Rework Station TABLE OF CONTENTS

Machine Safety Switch: SI-LM40 Series Limit Switch Style

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Combustible Gas Transmitter RK-05

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Operating Precautions: User configuration options:

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

8146/5 Series Breaker Panelboards

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

ACS-30-EU-EMDR-10-MOD

Bubble King. User Manual

SELECTION, APPLICATION & MAINTENANCE

OPL BASIC. Dosing System for Professional Laundry machines. Contents

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

LOXONE 12 Channel Amplifier

3M Wrist Strap and Footwear Tester 740. User s Guide

5800 Temperature Sensor Cable Assembly

Applied Electronics. Commercial Dimming System UPDATE NOTICE

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Installation and Operating Instructions (for chargers shown below)

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

BroadBand PowerShield. User Manual

Water Leak Detection System

15GAL STEEL OIL DRAIN WITH 110V PUMP

12-Volt Negative Ground Installation Instructions

Vehicle Power Install Kit

Model 1756 Test Lead Kit

Instructions For SF 6 Refill Kit

Universal Vehicle Power Supply 9007AX01. Installation Instructions

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

7 FUNCTION DIGITAL MULTIMETER

UniStream CPU-for-Panel

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Fire Fighter Phone System Installation Instructions

Co-location Interconnect Power Panel (CIPP) Installation Guide

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

INSTALLATION INSTRUCTIONS

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Safety instructions VEGADIS DIS81.CEIA/V****

ADM1TE 5/30A DIN rail single phase two wire energy meter

CoolWave r 2 Phase Control Board and Cable Replacement Kits

SECTION LOW VOLTAGE LIGHTING CONTROLS

Machine Safety Switches

Transcription:

Scully ST-47C Groundhog Technical Manual ST-47C Series Self-Proving Vehicle Earthing Verification System MaxSafety SYSTEMS Scully Signal Company / Tel. 67 692 8600 / Fax. 67 692 8620 / 800 2 SCULLY (272 8559) 70 Industrial Way, Wilmington, MA 0887-3479, USA / sales@scully.com / www.scully.com

ST-47C Groundhog - Technical Manual Table of Contents General 4.. Description.2 Technical Specifications.3 Accessory Equipment Installation 8. 2. Mechanical Installation 2.2 Electrical Installation 2.3 Initial System Checkout Maintenance 2. 3. Enclosure 3.2 Corrosion Protection 3.3 Control Module (Circuit Board) 3.4 Module Replacement 3.5 Indicator Lights 3.6 Control (Bypass) Switch 3.7 Junction Box and Plug & Cable Unit 3.8 Troubleshooting Diagram Appendix 4. DWG 342 Outline Drawing Control Unit Enclosure 6. 4.2 DWG 63039 Outline Drawing Sculcon Junction Box 7. 4.3 DWG 644 Wiring Diagram Typical Loading Rack Control 8. 4.4 DWG 6442 Mounting Diagram Control Unit & Junction Box 9. 4.5 DWG 6408 Internal Wiring Diagram - ST-47C-EL 20. 4.6 DWG 6407 Internal Wiring Diagram - ST-47C-ELK 2. 4.7 DWG 6404 Installation Wiring Diagram, ST-47C w/ SC-47 Plug 22. 4.8 DWG 6200 Installation Wiring Diagram, ST-47C w/ SC-47 Clamp 23. 4.9 DWG 6405 Installation Wiring Diagram, ST-5C/ST-47C 24. 4.0 DWG 6406 Installation Wiring Diagram, ST-35C/ST-47C 25. 4. DWG 6557 Replacement Parts ST-47C-20 26. 4.2 DWG 6274 Replacement Parts ST-47C-240 27.

ST-47C Groundhog - Technical Manual General The ST-47C Groundhog is an intelligent system that continuously and automatically monitors the earthing connection during loading operations at the gantry (loading terminal). The Groundhog is designed to immediately shut down the loading operation if the earth connection is broken. The Groundhog control monitor is mounted at the gantry. Indicator lights on the cover of the control monitor are visual reference that proper earthing has or has not been accomplished. The Groundhog requires that each vehicle be equipped with a specially designed Scully electronic Ground Ball or Ground Bolt. Before the loading operation can begin, the controller must see an intelligent return signal from the Ground Ball or Ground Bolt, indicating that a proper earthing connection has been made. The Groundhog frustrates typical cheating methods and malfunctioning problems that can lead to earthing vehicles improperly. The ST-47C Groundhog insures that unless the proper earthing connection has been made, the loading process will not begin. It will automatically shut down the loading operation if the ground is broken.. Description The ST-47C Groundhog can be wired into your existing Scully Overfill Prevention system for the ultimate safety system. One connection gives you overfill and earthing protection. This single connection simplifies loading and eliminates the need for additional plugs and cables at the gantry. When wired into an overfill prevention system, the ST-47C Groundhog utilizes a spare conductor in the existing Scully overfill prevention plug and cable together with a special Scully Ground Bolt mounted on each vehicle. The Scully Ground Bolt sensing lead is wired to the Scully overfill prevention socket. The ST-47C Groundhog can be used as a completely independent system. This system is ideal for top loading or applications where a Scully Overfill Prevention System is not in use. The ST-47C Groundhog control monitor connects to a heavy duty Scully Sculcon Junction Box Kit with attached cable and special quick release snap-on plug. The Scully Ground Plug connects to a specially designed electronic Scully Ground Ball mounted on each vehicle. The controller, in conjunction with the Ground Ball provides and verifies vehicle earthing before loading can begin. The controller must receive an electronic return signal from the Ground Ball throughout the loading operation. Page 4.

Self-Proving Vehicle Earthing Verification System General.. Model Designations The ST-47C Controller is available in 20VAC or 240VAC models, with or without control (Bypass) Switch. Model suffix (E) = Explosion-proof Enclosure, (L) = Indicator Lights, (K) = Key Lockable Bypass Switch. Model ST-47C-20 EL ST-47C-20 ELK ST-47C-240 EL ST-47C-240 ELK Description Controller in Explosion-proof Enclosure with Indicator Lights, 20VAC Controller in Explosion-proof Enclosure with Indicator Lights and Key-lockable Bypass Switch, 20VAC Controller in Explosion-proof Enclosure with Indicator Lights, 240VAC Controller in Explosion-proof Enclosure with Indicator Lights and Key-lockable Bypass Switch, 240VAC..2 Explosion Proof Enclosure Suffix "E" in the model number indicates controller is in an explosion-proof enclosure suitable for hazardous areas. Conduit holes are provided in the enclosure for electrical access. The installer must install Exd cable glands (or conduit and seal fittings) according to local codes...3 Indicator Lights Suffix "L" in the model number indicates red and green indicator lights on the controller enclosure. These lights indicate the following conditions: GREEN RED Condition ON OFF A good earth (ground) connection is verified Controller output is in permissive state i.e. permit to load. OFF ON A good earth (ground) connection is not verified. Controller output is in non-permissive state i.e. no permit to load. OFF OFF No power to the unit or Bypass Control Switch is in OFF or BYPASS position...4 Bypass Control Switch Adding the suffix "K" to the model number adds a lockable two-position control switch to the enclosure. In the "NORMAL" position, the unit will operate normally, with verification of proper earth (ground) connection causing the output relay to become energized (i.e. closed output contact). In the "BYPASS" position, power to the unit is switched "OFF" and the normally open relay contacts are bypassed to permit emergency operation of the equipment, without earthing verification. For normal operation, this switch should always be set in the NORMAL position. The switch is enclosed in lockable box to allow locking with a user provided padlock. CAUTION: When in "BYPASS" mode the earth ground verification is DISABLED and the system does not provide earth (ground) connection verification. Page 5.

ST-47C Groundhog - Technical Manual General.2 Technical Specifications Temperature Range Power Requirements Vehicle Interface Output Relay Response Time Indicator Lights Output Control Fuse Connections Enclosure Dimensions Weight Approvals -40 C to +60 C (-40 F to +40 F) 20VAC Models: 00-30 VAC, 50/60 Hz, 20VA Max.* 240VAC Models: 200-250 VAC, 50/60 Hz, 20VA Max. * *20VA does not include circuits controlled by the output relay contact Scully Ground Ball (via Ground Ball connector plug), Scully Ground Bolt (via plug for overfill prevention socket), Clamp connection (Resistive). One normally open volt-free contact rated 250VAC, 5A resistive max. The output contact closes when a proper earth connection has been established. 0.5 second maximum Output status indicator lights: Red: Non-permissive Green: Permissive Internal 5 Ampere Provided by internal terminal strips. Explosion-proof weatherproof IP65 See Appendix 4 for outline drawing 2 Kg (26 Lbs.) Ex d [ia] IIB T5 Gb (Tamb= -40 C to +60 C) U m = 20VAC or 240VAC U o = 5V C o = 9nF Io = 7mA L o = 40mH P o = 0,25W Lo/Ro = 00μH/wΩ The enclosure provides protection from hazardous area in accordance with standard IP65. The rating of the enclosure is negated if the holes in the enclosure are unplugged/unscrewed or any holes are drilled into the enclosure. Cover screws to be minimum grade A2-70 stainless steel. The ST-47C control unit has been designed to be impact-resistant. Do not subject to excessive mechanical or thermal stresses. Do not allow the unit to come in contact with aggressive substances. The ST-47C may only be repaired by replacing the internal control module. The internal control module is non-repairable. WARNING: Do not open when an explosive gas atmosphere is present. Page 6.

Self-Proving Vehicle Earthing Verification System General.3 Accessory Equipment In addition to the control unit, a plug and cable assembly is needed to provide the inter-connection from the ST-47C Control Unit to the vehicle. Scully highly recommends the use of our Sculcon Junction Box with Plug and Cable assembly. Use of Sculcon junction box simplifies system installation and provides for easy service of the plug and cable assembly for maintenance. Wiring the plug and cable assembly directly into the bottom of the ST-47C enclosure is not recommended and will result in greatly increased maintenance time and difficulty when the plug and cable assembly requires maintenance..3. Sculcon Junction Box with Plug and Cable Assembly One of the following junction box and cable kits is needed to make connection to a vehicle when fitted with Scully Ground Ball. Model SC-47 SC-47CC SC-47CC-CLMP Description Sculcon Junction Box Kit with 6m (20') straight cable and ground-proving plug for connection to vehicle mounted ground-proving ball (independent system). Sculcon Junction Box Kit with 0m (32') coiled cable and ground-proving plug for connection to vehicle mounted ground-proving ball (independent system). Sculcon Junction Box Kit with 0m (32') coiled cable and isolated jaw, static ground clamp for connection to vehicle chassis (independent system). This Junction Box and Clamp Kit is required for connection directly to the frame of the vehicle. * * Use of this cable requires operation of the ST47C system in its resistive verification configuration. Such use does not use a Ground Bolt or Ground Ball and, as such, does not have the anti-cheating advantages provided by the Ground Bolt or Ground Ball systems. Contact Scully Technical Services for more information. For a list of cables that integrate the ST-47C into Overfill Prevention systems, consult Scully Tech Data Sheet 6064. Page 7.

ST-47C Groundhog - Technical Manual Installation The ST-47C control system is typically installed in areas that are classified as hazardous locations due to nature of the products being loaded. Installation of the control unit and accessories must therefore be done by qualified personnel in accordance with all national and local regulations (codes) governing the installation of electrical equipment in hazardous locations. It is essential that the ST-47C control unit and accessories be installed and used in accordance with the detailed specifications and instructions in this manual. Installations that violate national and local regulations (codes) for installation of electrical equipment in hazardous locations and/or details in this manual may lead to unsafe operation. Intrinsically safe wiring to/from TB2 at the bottom of the control module must enter/exit the bottom opening in the control unit enclosure labeled "Intrinsically Safe Entry". Intrinsically safe wiring must be kept physically separated from any other wiring. 2. Mechanical Installation When choosing a location on the loading rack for the control unit, the lights on the front of the control unit should be readily visible and within easy reach of the user. The control unit should be mounted vertically, in a location where the cover can open for servicing. (See Diagram 6442 in Appendix 4 for installation.) Refer to the Outline Drawing 342 in Appendix 4 for physical dimensions, location of the mounting bolts, electrical cable/conduit entry locations and enclosure earth bonding stud. The enclosure earth-bonding stud is provided for proper electrical bonding (earthing) of the enclosure to earth (ground). Use only the three conduit entry holes provided for wiring. The top two holes are for power and control wiring. The bottom hole is for intrinsically safe sensor wiring only. Do not drill any additional conduit holes in the enclosure; doing so violates the enclosure's hazardous location approval and voids the warranty. To avoid future maintenance issues regarding water infiltration into the enclosure via the electrical cable entries, we strongly recommend the following precautions: Minimize long vertical cable (or conduit) runs into the top of the enclosure as long vertical runs promote water channeling to the cable gland. The cable glands at the top of the enclosure should be very carefully installed, taking extra precaution to make certain that the installation is proper and sealed (as required by code). Must seal all enclosure cable gland entries to maintain IP65 rating and protect against water infiltration. Install a fiber washer between the cable gland and the enclosure. 2.2 Electrical Installation Refer to the Installation Wiring Diagrams in Appendix 4. All cable entry fittings, junction boxes, connections, wiring, etc. are to be provided by the installer. Explosion- proof cable glands should be employed for cable entry. If conduits are used for cable entry, seal fittings must be installed in each conduit. Page 8.

Self-Proving Vehicle Earthing Verification System Installation There are three holes in the enclosure for cable entry. Two holes in the top of the enclosure are for mains power and control output wiring. One hole in the bottom of the enclosure, labeled "Intrinsi cally Safe Entry" is for connection to ground verifications, via a Scully Sculcon Junction Box. WARNING The electrical cable entry in the bottom of the enclosure marked "INTRINSICALLY SAFE ENTRY" must only be used for vehicle interconnection (via plug and cable assembly). To maintain intrinsic safety, this cable entry must not be used for any other wiring. DO NOT ROUTE MAINS POWER THROUGH THIS HOLE. 2.2. Power Connections Route the mains power wires through the top left-hand entry hole in the top of the enclosure. Connect mains power wires to the appropriate terminals on the terminal block (strip) on the metal bracket in the enclosure. The Power terminals are marked E, N & L, also shown in wiring diagram. NOTE: The ST-47C Control Module is protected by a field replaceable A high interrupt capacity fuse in the enclosure. The fuse (F) is located next to the terminal strip on metal bracket. 2.2.2 Enclosure Earth (Ground) Connection Connect a wire (.5mm2 minimum) from the enclosure-bonding stud to earthed metallic structure of the gantry (rack). 2.2.3 Control Output (Controlled Circuit) Connections Route the control output wiring through the top right hand entry hole in the enclosure and connect to output contact terminals, indicated on the terminal strip on metal bracket. The output control contact is open when no connection from the controller is made to a vehicle (idle state). The output control contact closes when a proper static discharge path (earthing) between the gantry and the vehicle has been established (or when optional bypass switch is in the "Bypass" position). The contact opens if the discharge path is broken or disconnected. NOTE: An internal field replaceable 5A high interrupt capacity fuse protects the output relay contact. The fuse (F2) is located on metal bracket. The output contact is rated 250VAC, 5A resistive maximum. It is used to close a valve or pump directly or by wiring it in series with other control contacts, such as a preset meter's control contacts. (See Diagram 644, Typical Loading Rack Control in Appendix 4.) In addition it may also be connected to an input of a terminal automation system (TAS) to provide status of the controller's output to TAS. Caution: A valve or pump should be directly controlled by ST-47C's relay output contact. It should not go via the logic circuits of a TAS, as that can introduce unsafe failure modes into this emergency shutdown system. TAS may also control a valve or pump based on other conditions. Page 9.

ST-47C Groundhog - Technical Manual Installation 2.2.4 Intrinsically Safe Connections to Sculcon Plug & Cable Unit Signals from ST-47C to Sculcon Plug & Cable Unit are intrinsically safe. The intrinsically safe connections must only be made via the entry hole in the bottom of the enclosure. The connections are made to the terminal strip TB2 at the bottom end of the printed circuit board module. The wires must be.5mm2 (8AWG) minimum conductor size. Connect wires to Sculcon as shown in the Wiring Diagram in Appendix 4. Use wire colors as indicated. If other than suggested color codes are used, this information should be so noted in the back of this manual for future reference and troubleshooting. All wiring installation should be in accordance with local wiring codes. 2.3 Initial System Checkout 2.3. Test Equipment Scully suggests the use of Scully ST-2-DSWJ Universal Loading Rack Tester to perform system tests out as described below. The tester will expedite the initial system checkout of the ST-47C (when integrally wired with overfill). While not required, the tester provides all of the proper overfill prevention system connec tions to verify the new installation without the need to secure an actual vehicle for testing. ST-2-DSWJ Tester has multiple socket configurations for connection to all Scully Sculcon Plug Models. Note: If the ST-47 is not being used integrally with a Scully overfill prevention system, you must provide a vehicle or simulation equipped with the ground verification device(s) installed. 2.3.2 Operational Testing Apply power to the ST-47C control unit (and overfill control units, if present). If the ST-47 is not equipped with a Bypass Control Switch then the red lamp should be lit and the Green lamp should be off. If the unit is equipped with a Bypass Control Switch, place Bypass Control Switch in the normal position. Verify that the Red lamp is lit and Green lamp is off. Bypass Equipped Units only: Check status of lights with Bypass Control Switch in the following positions: NORMAL: Red light should be ON. Circuit is non-permissive BYPASS: Both lights should be OFF. Circuit is permissive Page 0.

Self-Proving Vehicle Earthing Verification System Installation On units equipped with Bypass Control Switch: Return the Bypass Switch to the NORMAL position. The Bypass Switch should be kept under a lock (user provided) so that its setting cannot be tampered with. Connect the Sculcon plug to the socket on the tester. Follow instructions provided with the tester. As the tester simulates a vehicle s overfill system and a Ground Bolt, the Overfill Control and ST-47C outputs will go permissive with green light ON and red light OFF. Page.

ST-47C Groundhog - Technical Manual Maintenance CAUTION: BEFORE PERFORMING ANY MAINTENANCE ON THE CONTROL UNIT, DISCONNECT POWER TO THE ST-47C AND WAIT FIVE MINUTES BEFORE OPENING THE ENCLOSURE. DO NOT OPEN WHEN AN EXPLOSIVE GAS IS PRESENT. 3. Enclosure Inspect the enclosure routinely for deterioration due to environmental corrosion. The control unit should be opened once per year for internal inspection and replacement of the corrosion inhibitor capsule. Repair or replace as necessary only hardware that appears cracked, broken, corroded or otherwise deteriorated. Cover screws must be minimum grade A2 70 stainless steel. 3.2 Corrosion Protection The control unit is shipped from the factory with a corrosion inhibitor capsule adhered to the inside of the cover. The corrosion capsule is designed to condition the atmosphere within the enclosure to resist corrosion. It is intended to last approximately year in normal use. As previously mentioned, the control unit should be opened once per year for internal inspection. At this time the corrosion capsule should be replaced (see Replacement Parts Sheet in Appendix Section 4). It is also recommended to replace the cover O-ring at the same time. 3.3 Control Module (Circuit Board) The ST-47C control unit's internal circuitry does not require any routine periodic maintenance, but should be inspected during routine maintenance for corrosion or other signs of damage. The control circuitry may be repaired only by replacing the internal control module with an equivalent module. The internal module is non-repairable. DO NOT ATTEMPT TO SERVICE OR REPLACE COMPONENTS ON THE ST-47C MODULE. DOING SO WILL NEGATE WARRANTIES, CERTIFICATIONS AND JEOPARDIZE INTRINSIC SAFETY ASPECTS OF THE DEVICE. If it is determined (after troubleshooting, see Section 3.8) that control module needs to be replaced, remove the faulty control module and install the replacement control module per the following steps: (See Figure ST-47C Control Module Illustration on following page). Non-operational control modules may be returned to Scully for repair. Contact Scully Technical Services for assistance in obtaining a Return Material Authorization (RMA) before returning any material to the factory. 3.4 Module Replacement REMOVING THE MODULE. Remove (disconnect) power from the ST-47C Control Unit. Make sure the work area is gas vapour free. 2. To open the ST-47C Control Unit cover, remove the (6) hex socket head bolts by using a 6mm hex wrench. 3. Mark/label wires connected to TB on printed circuit board (to be able to reconnect to the same terminal numbers on the replacement module). 4. Disconnect all wires connected to TB. 5. Mark/label wires connected to TB2. 6. Disconnect all wires connected to TB2. 7. Remove the Control Module assembly by loosening the four-(4) mounting screws located in the four corners of the Control Module assembly. Page 2.

Self-Proving Vehicle Earthing Verification System Maintenance INSTALLING REPLACEMENT MODULE. Place the new Control Module onto the mounting plate and attach the (4) mounting screws. 2. Reconnect the wires to TB2. 3. Reconnect the wires to TB. 4. Close the cover and attach the (6) cover bolts. Ensure the bolts are evenly tightened. 5. Apply power to the Control Unit and test for proper operation. (08 mm) (4.25 ) (95.25 mm) (3.75 ) (54. mm) (2.3 ) (2.7 mm) (.50 ) 2 3 4 5 6 7 8 9 TB (58.8 mm) (6.25 ) (7.5 mm) (6.75 ) 2 3 TB2 FOR #6 (3.5 mm) SCREW 4 PLACES Figure : ST-47C Control Module Illustration Note: The ST-47C Replacement Control Module cannot be repaired in the field. A damaged or faulty module must be replaced with an equivalent Scully ST-47C Control Module. The ST-47C Replacement Control Module must only be installed in Scully's explosion-proof enclosure. The enclosures' explosion-proof and weatherproof integrity must be maintained. Caution: Do not expose the Control Module to aggressive substances that may attack the exposed material. Page 3.

ST-47C Groundhog - Technical Manual Maintenance When used properly, contact with the control module will not cause physical injury or harm and does not pose non-electrical dangers. The unit does not produce excessive surface temperatures, or emit infrared electromagnetic or ionizing radiation. 3.5 Indicator Lights The control unit employs explosion-proof LED style lights. These do not require any maintenance or changing of bulbs. In the event a light is faulty, it must only be replaced with parts numbers shown in Replacement Parts Sheet in Appendix 4. Follow instructions provided with the replacement indicator lights (pilot lights). Note: Older ST-47C Controllers employed incandescent style lights. These require replacement of bulb if it blows. Refer to Replacement Parts Sheet in Appendix 4. Switch off AC power supply to the controller before replacing a bulb. 3.6 Control (Bypass) Switch On those models having a lockable control (Bypass) switch the switch box may be replaced, by removing two screws inside the switch box. The switch box is replaced as a unit. A faulty switch may also be replaced if necessary, see Replacement Parts Sheet in Appendix 4 for replacement part numbers. 3.7 Junction Box and Plug & Cable Unit The Sculcon Junction Box and Cable unit requires simple routine maintenance. More attention is needed in highly corrosive environments. Although it is not required, we recommend that the exposed electrical contact of the plug be coated with a corrosion inhibiting film routinely (once per month is suggested). Corrosion inhibiting spray, ACF-50 Corrosion Block (manufactured by Lear Chemical Research Corporation, Mississauga ON Canada www.learchem.com). Other external metal parts of these accessories may also be treated as necessary to prevent atmospheric corrosion problems. The exterior surface of the plug should be kept clean using a mild detergent based cleaning solution and water. The cabling should be routinely wiped of foreign material and cleaned to preserve the outer jacket. To protect it from loading arm damage etc., it is important to store the plug and cable out of harms way when it is not in use. A hook is provided on Sculcon Junction Box or, if an overfill prevention plug is used, a Scully Storage Socket may be used. 3.8 Troubleshooting The following troubleshooting guide should aid in an initial diagnosis of most problems encountered with installation and operation of ST-47C. Page 4.

Self-Proving Vehicle Earthing Verification System Maintenance Condition Possible Cause No lights ON, on front cover No power to control unit Control (Bypass) Switch in OFF position Bulb blown (on older units with incandescent lamps) Input power fuse (F) is blown Control Module is defective Bad wiring to lamps Green (Permissive) light ON, Control Output fuse (F2) is blown but control contact outut Wiring defect (control output contact wiring) does not activate Control Module is defective valve/pump Red (Non-permissive) Fault in wiring to junction box and/or plug light stays ON when Ground Ball (or Ground Bolt) not installed connected to vehicle properly on vehicle. equipped with Ground Ball Bad plug to Ground Ball or Ground Bolt socket (or Ground Bolt) connection Control Module is defective Incorrect wiring to ST-47C TB2 Page 5.

ST-47C Groundhog - Technical Manual Diagram Appendix 4. DWG 342 Outline Drawing Control Unit Enclosure 5.87 (49.0) 2.47 (62.7) ENCLOSURE EARTH BONDING STUD 2.00 (50.8) 342 RevC SEE NOTE 2 6.62 (68.) TOP VIEW R G 0, 4 PL 3.69 (347.7) 5.75 (46.0) (MOUNTING LUG CENTERS) scully.50 (2.7) 8.44 (24.3) FRONT VIEW 6.75 (7.5) (MOUNTING LUG CENTERS) REAR VIEW 8.38 (22.9) INTRINSIC SAFE ENTRY 2.25 (57.) NOTES:. DIMENSIONS ARE IN INCHES WITH MILLIMETERS IN PARENTHIESS. 2. ENTRY HOLES: FMC APPROVED MODELS: 3/4" NPT ATEX APPROVED MODELS: M20 X.5 5.87 (49.0) SEE NOTE 2 BOTTOM VIEW Page 6.

Self-Proving Vehicle Earthing Verification System Diagram Appendix 4.2 DWG 63039 Outline Drawing Sculcon Junction Box 7.87 (200.0) 7.33 (86.2) 63039 RevF 2 3 4 5 6 Ø.06 (27) HOLE FOR CONDUIT HUB (CABLE GLAND).44 (36.6) 3.94 (00.0) Ø.06 (27) KNOCKOUT FOR CONDUIT HUB (CABLE GLAND) 3.94 (00.0) 3.20 (8.3) 2.58 (65.5) MOUNTING CENTERS FOR #8 (4) HEX SOCKET HEAD SCREWS (4 PLACES) NOTES:. DIMENSIONS ARE IN INCHES WITH MILLIMETERS IN PARENTHIESS. Page 7.

ST-47C Groundhog - Technical Manual Diagram Appendix 4.3 DWG 644 Wiring Diagram Typical Loading Rack Control MAINS POWER HOT NEUT TO OTHER LOADING RACK TO OTHER SET-STOP METERS ON SAME RACK HI FLOW 4 5 5A LO FLOW TERMINALS EMERGENCY SHUTDOWN SWITCH OR RELAY SCULLY CONTROL UNIT'S OUTPUT CONTACT CARD READER PERMISSIVE CONTACTS SET-STOP METER VALVE CONTROL CONTACTS TYPICAL LOADING RACK CONTROL SHOWING PERMISSIVE CONTACTS IN CIRCUIT TO LOADING VALVES. NOTE: WIRING SHOWN IS TYPICAL AND WILL VARY AS MORE OR LESS EQUIPMENT IS EMPLOYED. PUMP CONTROL CIRCUITS NOT SHOWN. THIS DIAGRAM IS INTENDED TO BE USED ONLY TO CLARIFY USE OF CONTROL CONTACTS. ALL CONTACTS SHOWN IN NON-PERMISSIVE STATES. SV HI FLOW LO FLOW SV LOADING VALVE PILOT CONTROL SOLENOIDS 644 RevC Page 8.

Self-Proving Vehicle Earthing Verification System Diagram Appendix 4.4 DWG 6442 Mounting Diagram Control Unit & Junction Box MAINS POWER AND OUTPUT CONTROL WIRING INTRINSICALLY SAFE WIRING USING SEPARATE CABLE 3 4 3 2 ALTERNATIVE ENTRY FOR OUTPUT CONTROL WIRING (PLUG HOLE IF NOT USED) PLUG ASSEMBLY TO CONNECT TO OVERFILL PREVENTION SYSTEM ON VEHICLE. EQUIPMENT SCHEDULE (TYPICAL). CONTROL UNIT 2. SCULCON JUNCTION BOX WITH PLUG AND CABLE. 3. FLAMEPROOF Exd CABLE GLAND FITTING. IF CONDUITS ARE USED FOR CABLE ENTRY, SEAL FITTINGS MUST BE INSTALLED WITHIN 8 INCHES OF AN EXPLOSION-PROOF ENCLOSURE IN A HAZARDOUS LOCATION, IN EACH CONDUIT (NOT SHOWN). IMPORTANT: INTRINSICALLY SAFE AND NON-INTRINSICALLY SAFE WIRING MUST ALWAYS BE SEPARATED AND RUN IN SEPARATE CONDUITS/CABLES. 4. INDUSTRIAL CABLE GLAND FITTING. INSTALLATION NOTES. INSTALLATION MUST COMPLY WITH NATIONAL AND LOCAL REGULATIONS FOR INSTALLATIONS IN HAZARDOUS LOCATIONS DETAILS SHOWN ARE FOR REFERENCE ONLY AND ARE NOT INTENDED TO REPRESENT CODE COMPLIANCE. 2. THE INTRINSICALLY SAFE WIRING BETWEEN THE BOTTOM PORT OF THE CONTROL UNIT ENCLOSURE AND THE SCULCON JUNCTION BOX MUST BE RUN USING DEDICATED CABLE OR IN A CONDUIT. NO OTHER SIGNALS ARE TO BE RUN IN THIS CABLE OR CONDUIT. 3. MINIMIZE LONG VERTICAL RUNS OF CABLE INTO THE TOP PORTS OF THE CONTROL UNIT ENCLOSURE TO AVOID CONDENSATION CHANNELING. AND THE CONTROL UNIT ENCLOSURE AT ALL CABLE PORT ENTRIES. 4. USE FIBER SEALING WASHERS BETWEEN THE CABLE GLAND FITTINGS 5. ANY UNUSED HOLES IN THE FLAMEPROOF ENCLOSURE MUST BE PLUGGED USING A CERTIFIED FLAMEPROOF STOPPER PLUG. 6442 RevC Page 9.

ST-47C Groundhog - Technical Manual Diagram Appendix 4.5 DWG 6408 Internal Wiring Diagram - ST-47C-EL AC LINE VOLTAGE INPUT EARTH 2 NEUT 3 LIVE 4 SPST VOLT FREE PERMISSIVE CONTACT 5 C NO TB (END USER WIRING TERMINAL) F A FAST BLOW SEE NOTE 3 F2 5A FAST BLOW SEE NOTE 3 GRN WHT WHT BLK RED BLK YEL BRN ORN GRN WHT BLK ORN BRN NOTES: UNLESS OTHERWISE SPECIFIED-. ``DRY'' CONTACTS CLOSE WHEN ST-47C IS IN PERMISSIVE MODE. 2. PERMISSIVE CONTACT RATED 250 VAC 5 AMP RESISTIVE. 3. USER REPLACEABLE FUSE. CHASSIS EARTH WHT G R BLK BLK FRONT COVER COMPONENTS GRN TB 2 3 4 5 6 7 8 9 AC LINE INPUT WET DRY DRY WET ST-47C-20/240 H CIRCUIT MODULE TB2 2 3 CONNECTION TO GROUND BOLT OR GROUND BALL 6408 RevA Page 20.

Self-Proving Vehicle Earthing Verification System Diagram Appendix 4.6 DWG 6407 Internal Wiring Diagram - ST-47C-ELK AC LINE VOLTAGE INPUT EARTH 2 NEUT 3 LIVE 4 C SPST VOLT FREE PERMISSIVE CONTACT 5 NO TB (END USER WIRING TERMINAL) F2 5A FAST BLOW SEE NOTE 4 S OPERATION CHART POS. NORMAL BYPASS SA SB CLOSED OPEN OPEN CLOSED BLK ORN BRN F A FAST BLOW SEE NOTE 4 GRN WHT WHT BLK YEL BRN ORN RED NOTES: UNLESS OTHERWISE SPECIFIED-. ``DRY'' CONTACTS CLOSE WHEN ST-47C IS IN PERMISSIVE MODE. 2. PERMISSIVE CONTACT RATED 250 VAC 5 AMP RESISTIVE. 3. SWITCH S SHOWN IN AUTO POSITION. 4. USER REPLACEABLE FUSE. EARTH SA SB G WHT FRONT COVER COMPONENTS GRN R BLK BLK BLK TB 2 3 4 5 6 7 8 9 AC LINE INPUT WET DRY DRY WET ST-47C-20/240 H CIRCUIT MODULE TB2 2 3 CONNECTION TO GROUND BOLT OR GROUND BALL 6407 RevA Page 2.

ST-47C Groundhog - Technical Manual Diagram Appendix 4.7 DWG 6404 Installation Wiring Diagram, ST-47C w/ SC-47 Plug EARTH NEUT } GROUNDHOG PLUG (USED WITH SCULLY GROUND BALL) NON-INTRINSICALLY SAFE WIRING (SEE NOTE ) BLK WHT TB TB SCULCON BOX MODEL SC-47CC (SEE NOTE 3) 20/240 VAC INPUT LIVE CONTACTS THAT CLOSE ON PERMIT 250 VAC, 5A RESISTIVE F F2 EARTH NEUT LIVE CONTROL MAINS POWER CONTACTS RATED 5 AMPS 250 VOLTS MAX FUSES F = A F2 = 5A SCULLY ST-47C MOUNTED IN A SAFE LOCATION OR SCULLY ST-47CE MOUNTED IN A ZONE, GROUP IIB HAZARDOUS LOCATION. VIEW A ST-47C-20/240 E(LK) GROUNDHOG 2 3 TB2 INTRINSICALLY SAFE WIRING (SEE NOTES & 2) 2 3 NOTES:. IMPORTANT: INTRINSICALLY SAFE AND NON-INTRINSICALLY SAFE WIRING MUST ALWAYS BE SEPARATED AND RUN IN SEPARATE CONDUITS. 2. WIRE TO BE 8 AWG MINIMUM, STRANDED AND TINNED. COLOR OF WIRES SHOULD MATCH CONTROLLER TERMINAL COLORS- IF POSSIBLE. IN ALL CASES WIRING MUST MEET APPLICABLE NATIONAL, STATE AND LOCAL CODES. 9 0 2 SEE VIEW A 560 OHM, /4W RESISTOR FOR AUX. STATIC BLEED-OFF 3. OTHER SCULCON MODELS CAN BE USED. CONSULT FACTORY FOR DETAILS. 4. INTERCONNECTION WIRING MUST NOT BE ALLOWED TO PASS THROUGH THE ST-47C HOUSING. UNDER NO CIRCUMSTANCES IS THE HOUSING TO BE USED AS A JUNCTION BOX. CONTROL (NON I.S.) WIRING MUST PASS IN AND OUT OF THE TOP CONDUIT ENTRY PORTS AND INTRINSIC SAFE (I.S.) WIRING MUST EXIT ONLY FROM THE BOTTOM CONDUIT ENTRY. 6404 RevB Page 22.

Self-Proving Vehicle Earthing Verification System Diagram Appendix 4.8 DWG 6200 Installation Wiring Diagram, ST-47C w/ SC-47 Clamp NOTES:. IMPORTANT: INTRINSICALLY SAFE AND NON-INTRINSICALLY SAFE WIRING MUST ALWAYS BE SEPARATED AND RUN IN SEPARATE CONDUITS. 2. WIRE TO BE 8 AWG (.5 ) MINIMUM, STRANDED AND TINNED. IN ALL CASES WIRING MUST MEET APPLICABLE NATIONAL, STATE AND LOCAL CODES. 3. OTHER INTERCONNECTION WIRING AT A LOADING BAY MUST NOT BE ALLOWED TO PASS THROUGH THE ST-47/ST-47C GROUNDHOG ENCLOSURE. UNDER NO CIRCUMSTANCES IS THE GROUNDHOG ENCLOSURE TO BE USED AS A JUNCTION BOX. CONDUIT ENTRY PORTS ON THE TOP OF GROUNDHOG ENCLOSURE MUST BE USED ONLY FOR NON I.S. WIRING (I.E. AC POWER AND CONTROL OUTPUT.) THE CONDUIT/CABLE ENTRY PORT AT THE BOTTOM OF THE ENCLOSURE IS FOR INTRINSICALLY SAFE WIRING AND MUST NOT BE USED FOR WIRING TO SC-47 JUNCTION BOX/GROUND VERIFICATION CLAMP. 4. CAUTION: INTRINSICALLY SAFE AND NON-INTRINSICALLY SAFE WIRING MUST ALWAYS BE KEPT SEPARATE AND RUN IN SEPARATE CONDUITS. NO WIRING SHOULD PASS THROUGH THE EXPLOSION-PROOF HOUSING. INPUT POWER 20 OR 240 VAC (SEE MODULE LABEL) LIVE NEUTRAL EARTH TB 5. TERMINAL 2 ON TB2 IS GROUND. TERMINAL ON TB2 IS THE GROUND MONITORING CIRCUIT. OTHER SCULCON JUNCTION BOX MODELS MAY BE USED. CONSULT FACTORY FOR DETAILS. SCULLY ST-47 IN EXPLOSION PROOF ENCLOSURE SUITABLE FOR CLASS I, DIVISION, GROUP C & D HAZARDOUS LOCATION. OR SCULLY ST-47C IN EXPLOSION PROOF ENCLOSURE SUITABLE FOR ZONE, GROUP IIB HAZARDOUS LOCATION. 2 3 BLK ISOLATED GROUNDING CLAMP WHT 9 0 2 SC-47CC/CLMP SCULCON JUNCTION BOX WITH CLAMP CONTACTS THAT CLOSE ON PERMIT 250 VAC, 5A RESISTIVE (PROTECTED BY 5 AMP INTERNAL FUSE) F F2 NON-INTRINSICALLY SAFE WIRING (SEE NOTE ) EARTH NEUT LIVE MAINS POWER CONTROL CONTACTS RATED 5 AMPS 250 VOLTS MAX ST-47/ST-47C GROUNDHOG 2 3 TM TB2 INTRINSICALLY SAFE WIRING (SEE NOTES, 2, 3, 4 AND 5) BLK WHT 560 OHM, /4W RESISTOR FOR AUX. STATIC BLEED-OFF 6200 RevE 2 Page 23.

ST-47C Groundhog - Technical Manual Diagram Appendix 4.9 DWG 6405 Installation Wiring Diagram, ST-5C/ST-47C 20/240 VAC INPUT NEUT EARTH LIVE CONTACTS THAT CLOSE ON PERMIT 250 VAC, 5A RESISTIVE } NON-INTRINSICALLY SAFE WIRING (SEE NOTE ) NON-INTRINSICALLY SAFE WIRING (SEE NOTE ) TB F F2 TB F F2 EARTH NEUT LIVE MAINS POWER CONTROL CONTACTS RATED 5 AMPS 250 VOLTS MAX FUSES F = A EARTH NEUT LIVE MAINS POWER CONTROL CONTACTS RATED 5 AMPS FUSES F = A F2 = 5A F2 = 5A 250 VOLTS MAX VIEW A ST-5C-20/240 E(LK) TB2 TB2 ST-47C-20/240 E(LK) GROUNDHOG 2 3 SCULLY ST-47C MOUNTED IN A SAFE LOCATION OR ST-47CE MOUNTED IN A ZONE, GROUP IIB HAZARDOUS LOCATION. GRN WHT BLK SCULLY ST-5C MOUNTED IN A SAFE LOCATION OR ST-5CE MOUNTED IN A ZONE, GROUP IIB HAZARDOUS LOCATION. SEE NOTE 5 NOTES:. IMPORTANT: INTRINSICALLY SAFE AND NON-INTRINSICALLY SAFE WIRING MUST ALWAYS BE SEPARATED AND RUN IN SEPARATE CONDUITS. TANKER CONNECTOR PLUG PLUG PIN 3 (WHT/BLK) PLUG PIN 4 (GRN) PLUG PIN 5 (RED) PLUG PIN 6 (ORN) PLUG PIN 7 (BLK) PLUG PIN 8 (BLU) PLUG PIN 9 (ORN/BLK) PLUG PIN 0 (WHT) 0 2 2 3 4 5 6 7 8 9 INTRINSICALLY SAFE WIRING (SEE NOTES & 2) ORN/BLK WHT 2. WIRE TO BE 8 AWG MINIMUM, STRANDED AND TINNED. COLOR OF WIRES SHOULD MATCH CONTROLLER TERMINAL COLORS- IF POSSIBLE. IN ALL CASES WIRING MUST MEET APPLICABLE NATIONAL, STATE AND LOCAL CODES. 3. OTHER SCULCON MODELS CAN BE USED. CONSULT FACTORY FOR DETAILS. 4. INTERCONNECTION WIRING MUST NOT BE ALLOWED TO PASS THROUGH THE ST-5C OR ST-47C HOUSINGS. UNDER NO CIRCUMSTANCES, ARE THE HOUSINGS TO BE USED AS JUNCTION BOXES. CONTROL (NON I.S.) WIRING MUST PASS IN AND OUT OF THE TOP CONDUIT ENTRY PORTS AND INTRINSIC SAFE (I.S.) WIRING MUST EXIT ONLY FROM THE BOTTOM CONDUIT ENTRY. 5. FACTORY INSTALLED JUMPER. DO NOT REMOVE UNLESS ST-5C IS TO BE CONNECTED TO MODEL SP-BLHK SENSORS. TB SCULCON BOX MODEL SC-6A(B) (SEE NOTE 3) SEE VIEW A 560 OHM, /4W RESISTOR FOR AUX. STATIC BLEED-OFF 6405 RevB Page 24.

Self-Proving Vehicle Earthing Verification System Diagram Appendix 4.0 DWG 6406 Installation Wiring Diagram, ST-35C/ST-47C 20/240 VAC NEUT INPUT EARTH LIVE CONTACTS THAT CLOSE ON PERMIT 250 VAC, 5A RESISTIVE NON-INTRINSICALLY SAFE WIRING (SEE NOTE ) TB F F2 TB F F2 EARTH NEUT MAINS POWER LIVE EARTH NEUT LIVE MAINS POWER CONTROL CONTACTS RATED 5 AMPS 250 VOLTS MAX VIEW A ST-47C-20/240 E(LK) GROUNDHOG 2 3 SCULLY ST-47C MOUNTED IN A SAFE LOCATION OR SCULLY ST-47CE MOUNTED IN A ZONE, GROUP IIB HAZARDOUS LOCATION. RED BLK ORN YEL } NON-INTRINSICALLY SAFE WIRING (SEE NOTE ) CONTROL CONTACTS RATED 5 AMPS 250 VOLTS MAX FUSES F = A F2 = 5A FUSES F = A F2 = 5A ST-35C-20/240 E(LK) TB2 TB2 SCULLY ST-35C MOUNTED IN A SAFE LOCATION OR SCULLY ST-35CE MOUNTED IN A ZONE, GROUP IIB HAZARDOUS LOCATION. NOTES:. IMPORTANT: INTRINSICALLY SAFE AND NON-INTRINSICALLY SAFE WIRING MUST ALWAYS BE SEPARATED AND RUN IN SEPARATE CONDUITS. TANKER CONNECTOR PLUG PLUG PIN 4 (GRN) PLUG PIN 5 (RED) PLUG PIN 6 (ORN) PLUG PIN 8 (BLU) PLUG PIN 9 (ORN/BLK) PLUG PIN 0 (WHT) 2 3 4 5 6 7 8 9 0 2 INTRINSICALLY SAFE WIRING (SEE NOTES & 2) ORN/BLK WHT 2. WIRE TO BE 8 AWG MINIMUM, STRANDED AND TINNED. COLOR OF WIRES SHOULD MATCH CONTROLLER TERMINAL COLORS- IF POSSIBLE. IN ALL CASES WIRING MUST MEET APPLICABLE NATIONAL, STATE AND LOCAL CODES. 3. OTHER SCULCON MODELS CAN BE USED. CONSULT FACTORY FOR DETAILS. 4. INTERCONNECTION WIRING MUST NOT BE ALLOWED TO PASS THROUGH THE ST-35C OR ST-47C HOUSINGS. UNDER NO CIRCUMSTANCES, ARE THE HOUSINGS TO BE USED AS JUNCTION BOXES. CONTROL (NON I.S.) WIRING MUST PASS IN AND OUT OF THE TOP CONDUIT ENTRY PORTS AND INTRINSIC SAFE (I.S.) WIRING MUST EXIT ONLY FROM THE BOTTOM CONDUIT ENTRY. TB SCULCON BOX MODEL SC-6AO OR 6W (SEE NOTE 3) SEE VIEW A 560 OHM, /4W RESISTOR FOR AUX. STATIC BLEED-OFF 6406 RevB Page 25.

ST-47C Groundhog - Technical Manual Diagram Appendix 4. DWG 6557 Replacement Parts ST-47C-20 REPLACEMENT PARTS for ST-47C 20VAC ST-47C 20VAC Groundhog Vehicle Earthing Controller ATEX Models Part No. Model 08844 ST-47C-20 EL 08845 ST-47C-20 ELK Note: Controller Models Suffix:: Explosion-proof housing (E), Indicator Lights (L), Key (K) Lockable Bypass Switch. 2 Replacement Parts Item Part No. Description Qty. 26343 Main Fuse, Ampere 3 9 2 26350 Control Fuse, 5 Ampere 3 095 ST-47C-20 Replacement Module 4 08350 Bypass Switch Lockbox (includes 2 mounting screws) 5 6 7 5 09220 Replacement Light Explosion Proof Lamp Assembly, Green, LED Style 6 0922 Replacement Light Explosion Proof Lamp Assembly, Red LED Style 4 7 50005 Socket Head Cap Screw, Stainles 6 8 2733 Corrosion Capsule 9 3340 O-ring cover seal 0 26022 Bypass Switch Contact Block 26093 Bypass Switch Operator 2 Position * 27085 Bulb, 20V, 6W* Notes: Item 7: New socket head screw used on models built after 0/92. Item 9: O-ring used on models built after 0/92. Item 5, 6: LED style lamps used on models built after 0/04/0. * Replacement bulb for incandescent style explosion-proof lights only. Use on models built prior to 0/04/0. 8 0 6557, Rev B 203 MaxSafety SYSTEMS Dynamic Self-Testing Overfill Prevention Systems Scully Signal Company 70 Industrial Way, Wilmington, MA 0887-3479, USA Tel: 800 272 8559 / 67 692 8600 email: sales@scully.com Scully Systems Europe NV Eksterveldlaan 3a 2820 Bonheiden / Belgium Tel: +32 (0) 5 56 00 70 email: info@scully.be Scully UK Ltd Meridian House, Unit 33, 37 Road One Winsford Industrial Estate, Winsford Cheshire CW7 3QG / UK Tel.: +44 (0) 606 553805 email: sales@scullyuk.com Page 26.

Self-Proving Vehicle Earthing Verification System Diagram Appendix 4.2 DWG 6274 Replacement Parts ST-47C-240 REPLACEMENT PARTS for ST-47C 240VAC ST-47C 240VAC Groundhog Vehicle Earthing Controller ATEX Models Part No. Model 0870 ST-47C-240 EL 087 ST-47C-240 ELK Note: Controller Models Suffix: Explosion-proof housing (E), Indicator Lights (L), Key (K) Lockable Bypass Switch. 2 Replacement Parts Item Part No. Description Qty. 26343 Main Fuse, Ampere 3 9 2 26350 Control Fuse, 5 Ampere 3 0952 ST-47C-240 Replacement Module 5 6 7 4 08350 Bypass Switch Lockbox (includes 2 mounting screws) 5 09420 Replacement Light Explosion Proof Lamp Assembly, Green, LED Style 6 0942 Replacement Light Explosion Proof Lamp Assembly, Red LED Style 4 7 50005 Socket Head Cap Screw, Stainles 6 8 2733 Corrosion Capsule 9 3340 O-ring cover seal 0 26022 Bypass Switch Contact Block 26093 Bypass Switch Operator, 2 Position * 27065 Bulb, 240V, 6W* Notes: Item 7: New socket head screw used on models built after 0/92. Item 9: O-ring used on models built after 0/92. Item 5, 6: LED style lights used on models built after 8/0 * Replacement bulb for incandescent style explosion-proof lights only. Use on models built prior to 8/0. 8 0 6274, Rev D 203 MaxSafety SYSTEMS Dynamic Self-Testing Overfill Prevention Systems Scully Signal Company 70 Industrial Way, Wilmington, MA 0887-3479, USA Tel: 800 272 8559 / 67 692 8600 email: sales@scully.com Scully Systems Europe NV Eksterveldlaan 3a 2820 Bonheiden / Belgium Tel: +32 (0) 5 56 00 70 email: info@scully.be Scully UK Ltd Meridian House, Unit 33, 37 Road One Winsford Industrial Estate, Winsford Cheshire CW7 3QG / UK Tel.: +44 (0) 606 553805 email: sales@scullyuk.com Page 27.

Notes: Page 28.

Notes: Page 29.

Notes: Page 30.

Scully - Setting Standards in Safety and Dependability since 936. For over seventy-five years Scully has been engineering and building products to the highest safety and reliability standards. We design and manufacture all of our systems under one roof to ensure complete quality control over our manufacturing and testing operations. Scully is ISO certified and all of our products are 00% made in the U.S.A. In addition, we back up our products with the best service in the industry. We have direct sales and service personnel in the U.S.A., The United Kingdom, and Europe and are represented in over 50 countries. For more information and 24 hour technical assistance, call Scully Signal Company at -800-SCULLY (-800-272-8559). Scully Headquarters in Wilmington, MA U.S.A. Copyright 203 Scully Signal Company. MaxSafety, Sculcon and Scully are registered trademarks of Scully Signal Company. The names and logos of other companies mentioned herein may be trademarkes of their respective owners. This document is for informational purposes only. Scully makes no warranties, expressed or implied, in this document. All Rights Reserved. Specifications are subject to change without notice. 635 Rev D January 203 MaxSafety SYSTEMS Dynamic Self-Testing Overfill Prevention Systems Scully Signal Company 70 Industrial Way, Wilmington, MA 0887-3479, USA Tel: 800 272 8559 / 67 692 8600 email: sales@scully.com Scully Systems Europe NV Eksterveldlaan 3a 2820 Bonheiden / Belgium Tel: +32 (0) 5 56 00 70 email: info@scully.be Scully UK Ltd Meridian House, Unit 33, 37 Road One Winsford Industrial Estate, Winsford Cheshire CW7 3QG / UK Tel.: +44 (0) 606 553805 email: sales@scullyuk.com