3. Cooling System Closed-loop Pure Water-cooling. Rated Voltage: 6 ~ 66kV. Rated Current: 4000A (phase current).



Similar documents
14. Troubleshooting Guide

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

FACTS. Solutions to optimise network performance GRID

Element D Services Heating, Ventilating, and Air Conditioning

DYNACOMP The top-class dynamic response compensator

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Unified requirements for systems with voltages above 1 kv up to 15 kv

understanding medium frequency induction melting furnace and its components

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

ECOCIAT. Domestic hot water heat recovery unit

Product and Application Description

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Cable Solutions for Servo and Variable Frequency Drives (VFD)

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

ES250: Electrical Science. HW7: Energy Storage Elements

CoolTeg Plus Chilled Water (CW) version: AC-TCW

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Line Reactors and AC Drives

Failure code manual. content

Series IDU/IDF. Refrigerated Air Dryer

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

INSTALLATION MANUAL. Address card EKAC10B

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

The following document contains information on Cypress products.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

FASTERCNC CO,. LTD. FASTERCNC CO,. LTD.

Oil and Coolant Circulating Heating System. Model - OCSM

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

DTC B1423/23 Pressure Sensor Circuit

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

BERMAD Fire Protection

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Trip circuit supervision relay. Type RXTCS

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Diagram of components 2. Reducer..3

Power Quality for Information Technology System

Medical Air Systems: Scroll

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

HEATER, AIR CONDITIONING AND VENTILATION

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

GUIDELINES TO INSTALL, OPERATE AND MAINTAIN HT CAPACITORS & IT S ASSOCIATED EQUIPMENT

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

The Do s and Don ts of Pressure Transducers

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Ground Resistance Clamp On Tester

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Limiting Grid Disturbances of Renewable Power Sources b.m.o Modern Power Electronics Paper ID FT3-5.2; , 16h30-17h00

COMPARISON OF AIR-CORE AND IRON-CORE REACTORS FOR MEDIUM-VOLTAGE POWER-QUALITY APPLICATIONS

SWIMMING POOL HEAT PUMP

Building Services Engineering Technician

Alfa Laval Abatigo. Redefining adiabatic cooling

How To Clean Up A Reactor Water Cleanup

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Telecommunication Line Protectors

Chilled Water HVAC Systems

PRODUCT PROFILE FEATURES

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PANASONIC TROUBLE SHOOTING GUIDE

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Portable Air Conditioner

KEMPER Leak Detection System

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

ASME Packaged Indirect Fired Water Heater

Fundamentals of Mass Flow Control

EMI and t Layout Fundamentals for Switched-Mode Circuits

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

T5000 T000 LCD Digital Fan Coil Thermostat

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

User s Manual Before using the inverter, you need to read and save the safety instructions.

RC NETWORKS SALES GUIDE

Diesel Engine Driven Generators Page 1 of 6

Process Alarm Solutions

Liebert PPC Second Generation Power Distribution Cabinet

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Presentation to CIGRE Next Generation Network. Visit of Seine substation

MAC-120HE-01 Air-Cooled Chiller

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Powerformer chosen for Swedish combined heat and power plant

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

CRAC Precision climate control units for data centres

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Transcription:

2. Thyristor Valves The thyristor valve adopts the compact structure with multilayer form, and the frame adopts the special metallic material. The thyristor valve is built up of thyristors which are from the foreign semiconduct company and can withstand the system maximum overcurrent/ overvoltage and higher dv/ dt, di/ dt. Cooperated with the reactor, the thyristor valve can achieve the nice dynamic response,high potential taken from the high potential panel,triggering and BOD protection function. It adopts photoelectric triggering mode with anti-jamming ability, which can ensure the SVC safe and reliable operation, efficient and convenient maintenance Rated Voltage: 6 ~ 66kV. Rated Current: 4000A (phase current). Trigger method: photoelectric trigger. Cooling method: closed- loop pure water- cooling, or high Thyristor valves efficient air- cooling. Special ability of preventing or withstanding false firing. Normal firing system and forced- firing system. Safe overvoltage protection. Perfect dynamic voltage sharing damping circuit and static voltage sharing circuit. Technically series connection thyristor 3. Cooling System Closed-loop Pure Water-cooling Precision design of the regulation and control system, multiple early warning and protection function make sure the cooler running under safe temperature. Many parameters are displayed in real time, such as cooling water pressure,cooling water flux, cooling water temperature, cooling water resistivity, valve hall temperature, the water level in the vessel. All core components choose foreign high uality products,and among them the main cycle pump,pipe filter,ion exchanger,precision filter,buffer container adopt the stainless material to avoid water leaking. Thyristor valve pipe Having the function of water leakage detection. the water-cooling control system will send alarm signal to the SVC control system, when the leakage is higher than setting value. Having the function of controlling the occurrence of dew. When the water temperature is below the dew point temperature, the water may be heated to prevent the occurrence of dew. Having the uniue function of the anti-freeze,which can guarantee the circulating cooling water not to freeze in the cold regions. Remote communication function. Annual availability is not less than 99.5%. Closed- loop pure water- cooling system POWER ADVANCED TECH. CO., LTD. 03 2F,4Cell, Tower C, In.Do Mansion,No.48A Zhichun Road, Haidian DistrictBeijing, PR China (100098) Tel. +86 (10) 5873 1010 (reception) Tel. +86 (10) 5873 2512 (direct) Fax. +86 (10) 5873 1816 info@ponovo.com.cn www.ponovo.com.cn

High Efficient Air-cooling Having high heat transfer efficiency with heat transferred via working media phase change. Running safely and reliably, maintaining efficiently and conveniently, suitable for small and mediumsized capacity of SVC. No corrosion, no pollution, low noise. 4. Filter Banks Filter banks are made up of several filter branches. On the one hand,they provide capacitive reactive power. on the other hand, they are needed for the filtering of harmonics generated by the load and the TCR. High efficient air-cooling system 5. TCR Reactor Dry, air-core, epoxy resin curing. Each phase reactor may be divided into two reactors. Manufacturing error: ±3%(each phase) ±2%(three phases). Adopting a structure of multiple conductors wound in parallel and multiple enclosures,and adopting small round section aluminum wires as coil conductor, which can ensure low eddy current and stray current,low interturn capacitance, and eual voltage distributing along height of coils. Filter banks Adopting lots of effective precautions to avoid tree discharge. Simple convenient installation and maintenance,no tinder, and running safely and reliably. Natural cooling. 6. Other Euipments Circuit breakers, isolating switches, surge arresters, current transformers etc. are manufactured by well-known companies at home and abroad to ensure the overall performance of SVC. TCR reactor POWER ADVANCED TECH. CO., LTD. 04 2F,4Cell, Tower C, In.Do Mansion,No.48A Zhichun Road, Haidian DistrictBeijing, PR China (100098) Tel. +86 (10) 5873 1010 (reception) Tel. +86 (10) 5873 2512 (direct) Fax. +86 (10) 5873 1816 info@ponovo.com.cn www.ponovo.com.cn