Carlon Bore-Gard and Boreable Multi-Gard Raceway



Similar documents
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Carlon Multi-Gard Multi-Cell Raceway

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

Carlon Carflex Liquidtight Flexible Tubing

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

How To Launch A Rocket From A Formica

IMPORTANT DOCUMENTATION DO NOT DISCARD!

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

TECHNICAL SPECIFICATION

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

SECTION UNDERGROUND ELECTRIC SERVICE

pvc well casing & drop pipe

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Duct PVC Duct Steel Duct Pre-Lubricated HDPE Bend PVC Duct Plug End Cap Duct Sealing Kit Sub Duct Anchor Plug PVC Cement PVC Cleaner Duct mandrel

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

SECTION NONREINFORCED CONCRETE SEWER PIPE

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

Royal Seal Gasketed Sewer Pipe

Flowtite Jacking Pipe

Terminations Standard Terminators (Type1) allow Multi-Gard to be terminated into a standard pre-cast termination for Type C or Type 40 PVC.

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE

Building essentials for a better tomorrow

Pro-Lift Steel Pile Foundation Repair

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION

There are three primary static sealing methods in use today; the flat gasket. And the molded elastomer seal.

Flue Installation. High Efficiency Condensing Boilers

WATER SERVICE 2

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

Pipe Cutting and Beveling Clamshells

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Rigid Conduit, Fittings, and Accessories Frequently Asked Questions

Quality & Innovation, Manufactured in the U.S.A.

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Section SEWER PIPE INSTALLATION AND TESTING

Carlon Multi-Gard Multi-Cell Raceway. PVC Fiberglass Galvanized Steel Electrical Metallic Tubing

T1-K. OPEN SLOT RIGID PVC (including cover) OPEN SLOT BLACK RIGID PVC (including cover) 2 PRICE LIST WD 115 STANDARD CARTON - FT LENGTHS PER CARTON

PVC Gasketed & Solvent Weld Pipe

SECTION POLYVINYL CHLORIDE (PVC) PIPE

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

Application Data Important Safety Information

Wastewater Capital Projects Management Standard Construction Specification

SMarT_Foundation [Simple Modular Technology] Assembly and Installation Instructions (U.S. Patent Pending)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Diamond LOK-21 Assembly Information

jbs nfb INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Mechanical Steering for Inboard, Outboard, and Sterndrive Powered Vessels

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL Pre-Insulated Piping

DIVISION 4300 STORM DRAINAGE

Cable Installation Notes

4 Installation Requirements

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

EH-20 20m antenna. By VE3RGW

4-600, 1000 psi. User s Guide to: Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384.

Morgan County Quality Water District Water Main Flood Damage Repair Project

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Beacon Hill Sewer District Standard Specifications

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

SUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*

Installation of Large Diameter Buried Pipes

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

Stainless Steel Single and Dual Circulation Kits

RING JOINT SYSTEMS 207

GPD Rubber Press Seals

Installation Instructions

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

TubeTrace, ThermoTube

Installation instruction CASAFLEX - Connecting piece DN 100

Intelligent Cable Management Systems

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Mechanical Joint Restraints

ASSEMBLY DIAGRAM AND ASSEMBLY REFERENCE ULTIMA OLD SCHOOL 2 EVO & TC BELT DRIVE UNITS

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe

Installation Instructions For Slider Casement Air Conditioners

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Scepter PVC Molded Junction Boxes

Installation Instructions for Wamilton s Steering Cable Modification. Remove the cables from the white retaining clip

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

Installation Instructions

Transcription:

Carlon Bore-Gard and Boreable Multi-Gard Raceway Bore-Gard Schedule 40 Bore-Gard Schedule 80 Boreable Multi-Gard Type 40 www.carlonsales.com 231

Bore-Gard Trenchless Raceway Carlon Bore-Gard Trenchless Raceway Carlon s PVC Bore-Gard conduit eliminates the costly problems of HDPE pipe on a reel such as reel handling, fusion welding, uncoiling and wasted pipe, safety hazards and additional job site labor. Bore-Gard is designed and proven to meet the rigorous requirements of horizontal directional drilling for electrical and datacom applications and is available in Heavywall Schedule 40 or Extra Heavywall Schedule 80 conduit. The unique design incorporates a water-tight seal and locking ring that enables fast, cement-free assembly, strong enough for 1000 foot bores. Short lengths of 10 and 20 feet fit into the tightest spaces and can be easily transported to the job site. Simplify trenchless installations and lower your costs with Bore-Gard. Insertion depth indicator tells at a glance if pipe ends are inserted to the correct depth. Heavy walls and deep insertion make the joint immune to the effects of normal bending. RUS Listed Precision engineered design has matching grooves and nylon locking strap to provide a secure connection. The belled end will not snag when pulled into a bore. Positive stop automatically aligns strap grooves. Triple-lobed gasket designed to provide ease of assembly and a watertight seal. Features: Easy to handle 10 and 20 foot lengths For bores up to 1000 feet Fast easy assembly Strong water-tight joints without cement Fits standard rigid nonmetallic conduit fittings All nonmetallic construction Superior crush and stiffness over HDPE Eliminates the need for chains and backing plate installation Type: Schedule 40 - Heavywall Schedule 80 - Extra Heavywall Sizes: Schedule 40-3", 4", 5", & 6" Schedule 80-3" & 4" Locking ring enables fast, cement-free assembly. Slide locking ring into the joint. Fully assembled, the locking ring provides strong water-tight joints without cement. 232 www.carlonsales.com

Carlon Boreable Multi-Gard Boreable Multi-Gard Carlon s PVC Boreable Multi-Gard conduit combines a strong boreable outerduct with the convenience of a Multi-Cell conduit. Boreable Multi-Gard utilizes leading technology from Carlon s PVC Bore-Gard Trenchless Raceway, offering a field-proven design. Bores up to 500 feet can be achieved without labor-intensive operations. Lengths of 20 feet fit into tight spaces often encountered on underground boring job sites. Experience the strength and convenience of Carlon Boreable Multi-Gard. Features: Withstands pulling and bending forces of directional drilling Fast assembly Eliminates labor related to gluing and screwing joints together Factory installed innerducts eliminate post bore installations. Heavy walls and deep insertion make the joint immune to the effects of normal bending. For bores up to 500 feet Innerducts: 3-way or 4-way Easy to handle 20 foot lengths Type: Type 40 PVC outerduct Size: 4" Prelubricated innerducts Precision engineered design has matching grooves and nylon locking strap to provide a secure connection. The belled end will not snag when pulled into a bore. Positive stop automatically aligns strap grooves. Triple-lobed gasket designed to provide ease of assembly and a watertight seal. Strong water-tight joints without cement Fits standard Schedule 40 fittings Compatible with Multi- Gard Type 40 PVC products Factory installed innerducts provide immediate post bore cable installation Designed to meet all your cable needs. www.carlonsales.com 233

Bore-Gard Statue of Liberty Carlon Bore-Gard was the product of choice when additional conduit was considered necessary for future utilities and cables on Liberty Island. Horizontal Directional Drilling was the preferred method of installation because it minimized any disruption to the island s pristine environment. Bore-Gard is a PVC trenchless raceway specifically designed for Horizontal Directional Drilling. Bore-Gard is seal rated for 75psi, keeping drilling fluid and underground water out. It has a strong, cement-free joint, making installations fast and easy. It comes in convenient 10 ft. and 20 ft. lengths and is strong enough for 1000 ft. bores. 234 www.carlonsales.com

Bore-Gard Assembly Bore-Gard /Boreable Multi-Gard Assembly Trim spigot end before attaching pulling eye. 1. Position Bore-Gard with the print line facing up. 2. Remove plastic locking strap and set it aside. 3. Remove end caps. On first stick only, trim spigot end of Bore-Gard at the groove before attaching the pulling eye/gripping attachment. 4. Insert pulling eye into spigot end of Bore-Gard. Tighten pulling eye so that it expands against interior of the conduit. 5. Tighten pulling eye so that it expands against the interior of the conduit. Use of sleeve over O.D. of conduit is recommended. 6. The installer should use appropriate instrumentation to insure that maximum pull rating is not exceeded. 7. Take next piece of Bore-Gard (10' or 20') and insert spigot end into belled end of the first piece until the insertion line is no longer visible. Attach the next piece of Bore-Gard. 8. Slide the plastic locking strap into slot on the side of the bell. Push the strap in completely. It is not necessary to remove or cover the handle on the strap. 9. Repeat with remaining sections as space allows. 10. Bore-Gard is now ready for installation. For additional information on the Bore-Gard line of products, request Frequently Asked Questions about Bore-Gard, BGFAQ; Bore-Gard Technical Reference Guide, BGTRG; Ten Reasons to Buy Bore-Gard, BG10REA and the Bore-Gard six minute Video, BGVID. All of these materials are available direct from Carlon or from your local Carlon representative. Boreable Multi-Gard Assembly 1. Position Boreable Multi-Gard with the print line facing up. 2. Remove plastic locking strap and set it aside. 3. Seal off lead end to keep out drilling fluid. 4. Attach 4" Kellems Grip over lead end. Note: Internal pulling eye cannot be used due to innerduct interference. 5. The installer should use appropriate instrumentation to insure that the maximum pull rating is not exceeded. 6. Take next piece of Boreable Multi-Gard and insert spigot end into belled end of the first piece until the insertion line is no longer visible. NOTE: Innerducts need to be aligned before insertion For more information on Carlon s Multi-Gard System, request catalog number 2B21. 7. Slide the plastic locking strap into slot on the side of the bell. Push strap in completely. It is not necessary to remove or cover the handle on the strap. 8. Repeat with remaining sections as space allows. 9. Pull into bored hole. Terminate into man holes. 10. Boreable Multi-Gard is now ready for duct proofing and cable installation. Bend Radius for Bore-Gard & Boreable Multi-Gard Minimum Bend Radius: Turns in a bore path should be made gradually. Bore-Gard and Boreable Multi-Gard have a minimum bend radius of 65'. Bending more than this recommended limit will stress the joint. The drawing below illustrates the 65' bend radius. To obtain a 90 turn you will require 65' of forward distance in any directional plane. Note: Successful directional drilling, reaming and pipe installation are influenced by numerous factors including the reamed diameter, pull rate, fluid chemistry, fluid flow rate, drill rod diameter, soil conditions, equipment performance and condition, and operator experience. All manufacturers equipment recommendations and training should be followed for successful drilling results. Bore-Gard is flexible enough to be pulled around a building. www.carlonsales.com 235

Bore-Gard /Boreable Multi-Gard Specifications Bore-Gard Specifications *U.S. Patent 6,789,629 Schedule 40 RUS Listed Overall Length (ft.) Lay Length O.D. (in.) Except where noted by I.D. (in.) Pkg. Qty. (ft./bundle) Bundles per Feet per Wt. per 100 ft. (lbs.) Except where noted by Min. Bend Radius (ft.) Insertion Force (lbs.) Seal Pressure Rating (P.S.I.) Joint Pull Rating (lbs.) Typical Crush lbs. (@ 30% deflection) UL Std. 651 & NEMA TC2 Min. Crush (lbs.) BG340SP-010 3" Sch. 40 Bore-Gard 10 9'6" 3.50 3.0 350 56 19,600 164 65 20 75 7,000 1,225 1,000 BG340SP-020 3" Sch. 40 Bore-Gard 20 19'6" 3.50 3.0 700 28 19,600 164 65 20 75 7,000 1,225 1,000 BG440SP-010 4" Sch. 40 Bore-Gard 10 9'6" 4.50 4.0 260 56 14,560 234 65 40 75 8,700 1,075 900 BG440SP-020 4" Sch. 40 Bore-Gard 20 19'6" 4.50 4.0 520 28 14,560 234 65 40 75 8,700 1,075 900 BG540SP-010 5" Sch. 40 Bore-Gard 10 9'6" 5.56 5.0 230 40 9,200 317 65 60 75 11,300 950 850 BG540SP-020 5" Sch. 40 Bore-Gard 20 19'6" 5.56 5.0 460 20 9,200 317 65 60 75 11,300 950 850 BG640SP-010 6" Sch. 40 Bore-Gard 10 9'6" 6.625 6.0 200 40 8,000 418 65 80 75 14,000 950 850 BG640SP-020 6" Sch. 40 Bore-Gard 20 19'6" 6.625 6.0 400 20 8,000 418 65 80 75 14,000 950 850 Schedule 80 RUS Listed Accessories Pulling Eyes These high-quality pulling eyes have a permanent outer sleeve and a seal on pipe O.D. Overall Length (ft.) Lay Length Package (in.) O.D. (in.) BG480SP-010 4" Sch. 80 Bore-Gard 10 9'6" 4.50 3.8 260 56 14,560 308 65 40 75 12,000 2,000 2,000 BG480SP-020 4" Sch. 80 Bore-Gard 20 19'6" 4.50 3.8 520 28 14,560 308 65 40 75 12,000 2,000 2,000 BG380SP-010 3" Sch. 80 Bore-Gard 10 9'6" 3.50 2.8 350 56 19,600 210 65 20 75 10,000 2,000 2,000 BG380SP-020 3" Sch. 80 Bore-Gard 20 19'6" 3.50 2.8 700 28 19,600 210 65 20 75 10,000 2,000 2,000 Package Weight (lbs.) Package Type BG3PE 3" Pulling Eye 10"x 4"x 4" 8 Carton BG4PE 4" Pulling Eye 17"x 6"x 6" 26 Carton BG5PE 5" Pulling Eye 16"x 7 3 /4"x 7 3 /4" 37 Crate BG6PE 6" Pulling Eye 19 1 /2"x 8 1 /4"x 8 1 /4" 63 Crate Length (ft.) O.D. (in.) Innerduct I.D. (in.) Pkg. Qty. (ft./bundle) Bundles per Feet per I.D. (in.) Pkg. Qty. (ft./bundle) Bundles per Wt. per 100 ft. (lbs.) Feet per Min. Bend Radius (ft.) Wt. per 100 ft. (lbs.) Seal Pressure Rating (P.S.I.) Maximum Pull Rating (lbs.) Min. Bend Radius (ft.) Insertion Force (lbs.) Locking Straps Size Seal Pressure Rating (P.S.I.) Std. Ctn. Qty. Joint Pull Rating (lbs.) Typical Crush lbs. (@ 30% deflection) UL Std. 651 & NEMA TC2 Min. Crush (lbs.) Gaskets Std. Ctn. Qty. 3" GSUP3 1 HBOR3 1 4" GSUP 1 HBOR 1 5" GSUP5 1 HBOR5 1 6" GSUP6 1 HBOR6 1 Boreable Multi-Gard Specifications MFSS3B-020 3-way Boreable Multi-Gard 20 4.50 1.50 520 28 14,560 561 65 75 5000 MFSS4B-020 4-way Boreable Multi-Gard 20 4.50 1.19 520 28 14,560 565 65 75 5000 Steel Mesh Grip part no. MAG4 is recommended to be used as pulling attachment for Boreable Multi-Gard. 236 www.carlonsales.com