Morgan County Quality Water District Water Main Flood Damage Repair Project
|
|
|
- Poppy Simmons
- 10 years ago
- Views:
Transcription
1 North American Society for Trenchless Technology (NASTT) NASTT s 2015 No-Dig Show TM1-T5-02 Morgan County Quality Water District Water Main Flood Damage Repair Project Nathan Ferguson, Farnsworth Group, Inc., Fort Collins, Colorado Steve Austin, Underground Solutions, Inc., Broomfield, Colorado Mark Kokes, Morgan County Quality Water District, Fort Morgan, Colorado ABSTRACT: Starting on September 9th, 2013 a slow-moving cold-front stalled over Colorado clashing with warm humid monsoonal air from the south. This resulted in heavy rain and catastrophic flooding along Colorado's Front Range from Colorado Springs to Fort Collins. The situation intensified on September 11th and 12th with 9-inches recorded on the 11th and as much as 17-inches recorded on the 12th. The flood waters spread 200 miles across a range of 17 counties. Governor John Hickenlooper declared a disaster emergency on September 12th in fourteen counties, including Morgan and Washington Counties, which is northeast of Denver. Morgan County Quality Water District (MCQWD) lost three of its four main water lines that cross the South Platte River when the flood waters passed through. When the flood waters subsided, MCQWD was able to reach and repair one of the damaged lines, but the other two that had been damaged needed to be replaced. Replacing these lines with traditional open-cut construction techniques would have required a very expensive effort to divert the river. Therefore the District turned to trenchless technology and horizontal directional drilling (HDD) to complete these challenging repairs. The HDD installations were 2,400 feet and 2,000 feet long, and included work in a difficult shale formation beneath the river. 1. INTRODUCTION Morgan County Quality Water District (MCQWD) supplies approximately 2,700 service connections to residents of Morgan County and the surrounding area. MCQWD serves the rural areas of Morgan and Washington counties, including the towns of Snyder, Hillrose, Goodrich, Weldona, Log Lane Village, Orchard, and Jackson Lake State Park. The system currently serves an area in excess of 650 square miles. MCQWD customers receive their water from the Hay Gulch, San Arroyo and Beaver Creek aquifers from eight wells which are appropriated approximately 2,800 acre feet of water per year. On average, the district supplies 60 million gallon of water per month or 2 million gallon per day (MGD). The peak summer demand can increase up to 3.8 MGD. In early September, 2013, a slow moving cold front combined with humid, monsoonal air from the south, resulting in extremely heavy rain and catastrophic flooding along Colorado s Front Range. When the flood waters reached Morgan County by way of the South Platte River, MCQWD s ability to service a large portion of its customers residing north of the South Platte River was severely hampered (see Figures 1 and 2). The raging waters damaged three of MCQWD s four main water supply lines that provide potable water to residents north of the South Platte River. After the flood waters subsided, the District was able to reach and repair one of the three damaged lines, but the other two could not be repaired and needed to be replaced. Replacing these lines with traditional open-cut construction techniques would require a very expensive effort to divert the river and would also require them to wait for the lowflow season months later after snow melt. Making this effort more complex would be the permits required to divert the river and perform the construction. These permits would be time consuming and difficult to obtain. TM1-T
2 The two remaining water lines crossing the South Platte River were incapable of meeting the demand in the service area north of the river. In order to avoid a public health hazard, at least one of the damaged lines needed to be replaced immediately. Figure 1. Flood waters overtake the established riverbanks in Morgan County, CO. 2. EMERGENCY MAIN REPLACEMENT AT THE NORTH TANK CROSSING Although MCQWD didn t have extensive experience with trenchless construction methodology, they were aware of how horizontal directional drilling (HDD) worked, some of the projects that had been completed using the method in the Front Range, and the identity of some of the local groups that were intimately involved with the method. Given the urgency of the situation, there was no time for an engineered design and subsequent bid process to secure the new pipe and drilling contractor. MCQWD worked with local sources to identify several experienced HDD contractors that had completed HDD Projects under the South Platte River, as well as experience with boring similar-sized pipe diameters more than 2,000 feet. A meeting was called with HDD Specialists and Global Underground at the proposed North Tank Crossing location to discuss the feasibility of an HDD installation to complete the emergency main replacement. When planning an HDD installation, identifying and clarifying unknowns is the key to risk reduction. Choosing a location for the HDD crossing was the first of several factors considered. A tie-in point to the existing distribution system north of the river and sufficient laydown room for the new pipe prior to insertion needed to be evaluated. If there is room, it is best to assemble the entire pipeline prior to beginning the pull-back operation. It is also best to align the pipeline so that it limits unnecessary bends as it enters the insertion point. Although it is possible to make intermediate fuses during pull-back, there is an increased risk of the bore-hole collapse, so it is avoided if possible. The final alignment for the North Tank Crossing was just under 2,500 linear feet, or nearly half a mile, and this is a lot of pipe length to lay out in one string prior to pull-back. MCQWD was able to find a location that allowed for a convenient tie-in location for the system, as well as layout the entire pipe alignment in one string in line with the HDD bore requirements. TM1-T
3 Figure 2. Flood waters nearly overcome a bridge crossing in Fort Morgan, CO, located in Morgan County. With a proposed alignment in place, the next unknown to characterize was the geology of the crossing at the depths required. MCQWD knew that several water wells had been drilled in the surrounding area over the years and were able to get copies of the bore logs. The logs showed mostly poorly graded sands & gravels as well as a shale formation at depth. The absence of cobles or potential coble bearing formations, and a solid shale formation under the river made the drillers optimistic that the proposed bore was feasible. Further, based upon the geotechnical information available, the drillers agreed that a target-depth that would provide at least 20 feet separation between the bore and the bottom of the river should be adequate to reduce the risk of inadvertent fluid returns during the installation. Since the new pipe being installed by HDD is literally pulled through a hole underground, the new pipe must be fully restrained to allow tensile loading of the pipe and joints. Traditional pipe materials used include steel, high density polyethylene (HDPE) and Fusible PVC pipe (FPVCP). Most new installations for the MCQWD are bell and spigot PVC pipe conforming to AWWA C900 (AWWA, 2007) or AWWA C905 (AWWA, 2010) standards, so their crews are already accustomed to working with PVC. This made the FPVCP option more attractive than the other two options in terms of future maintenance. MCQWD also ruled out steel pipe due to corrosion issues they ve seen in their system and focused on using HDPE or FPVCP. The project qualified for FEMA funding, so FEMA guidelines applied, meaning specifically that no improvements may be made by the new pipelines. This primarily meant that the new installations needed to closely match the function of the previous installations. The two water mains destroyed by the flood waters were a 12-inch ductile iron pipe and a 10-inch asbestos cement pipe with a total cross-sectional flow area of sq-in. (See Table 1). The goal in selecting the replacement pipes would be two-fold; first, they must be capable of being installed for the proposed installations and second, they must be capable of providing a similar but not improved ability to service residents north of the South Platte River. Table 1 Flow capacity of existing lines from a cross-sectional area perspective TM1-T
4 Pipe Area Inside Diameter (in.) Area Calculation (sq. in.) Area (sq. in.) N. Tank Crossing (12.45/2)^2 x π Log Lane Crossing 9.63 (9.63/2)^2 x π Total Pipe recommendations for the crossings were based upon the required pressure capacity, the hydraulic capacity in comparison to the previous installations, and the required safe allowable pull force capability. The required hydraulic capacity for a consistent/comparative replacement of the existing compromised pipe was critical. Relevant to this discussion is the required pressure classification for the replacement pipe. MCQWD indicated that working pressures including surge pressures consistently exceed 200 psi in this portion of the system and therefore would require the replacement pipe material to be rated 250 psi or greater. DR14 FPVCP has a maximum pressure capacity of 305 psi with a safety factor of 2.0 DR7.3 HDPE has a maximum pressure capacity of 250 psi with a safety factor of 2.0 The required safe allowable pull-force based on the soil conditions and distance of the HDD installation was also critical. Global Underground and HDD Specialists indicated they would be most comfortable with a safe allowable pull-force capacity of approximately 100,000 lbs for a 2,500 foot HDD installation. Therefore, considering required flow capacity, pressure capacity and the desired allowable pull-force capacity the pipe recommendations were as follows: 12-inch DR14 FPVCP: ID = inches, allowable pull force = 101,600 lbs. 14-inch DR7.3 HDPE pipe: ID = 9.93-inches, allowable pull force = 94,600 lbs. Although only the North Tank Crossing was being treated as an emergency replacement, MCQWD wanted to consider the pipe to be used for the second damaged line at Log Lane as well in order to take advantage of the economies of scale that would be realized if they could make a single purchase for all materials needed for the two damaged crossings. Selecting the 14-inch DR7.3 HDPE for the two line replacements would only provide sq. in. of flow area compared with the sq. in. flow area that was provided by the original pipelines, a 20 percent reduction. Upsizing the HDPE pipe option to 16-inch in order to achieve the needed flow area was ruled out due to the additional drilling expense for a larger hole. MCQWD therefore selected 12-inch DR14 FPVCP for both crossings. As shown in Table 2, two 12-inch DR14 pipes as the replacement for the lost 12-inch DIP and 10-inch AC pipelines provides sq. in., an increase of approximately 1 percent, but most importantly, no decrease. Table 2 Flow Capacity of two proposed 12-inch FPVCP pipes in terms of cross-sectional area Pipe Area Diameter (in.) Area Calculation (sq. in.) Area (sq. in.) N. Tank Crossing (11.20/2)^2 x π Log Lane Crossing (11.20/2)^2 x π Total Now that the alignment and the replacement materials had been selected, the only remaining decision MCQWD needed to make was which HDD Contractor would be given a contract to complete the emergency replacement at the North Tank Crossing. HDD Specialists and Global Underground submitted their estimates and MCQWD selected HDD Specialists. 3. EMERGENCY MAIN REPLACEMENT CONSTRUCTION REVIEW Despite the speed with which MCQWD was able to move forward with the emergency main replacement project at the North Tank Crossing, the winter season was well underway by the time HDD Specialists was able to mobilize to the site and begin drilling. Early in the drilling operations, HDD Specialists encountered about 40 feet of loose sands and gravels that were dissipating the mud flow and preventing it from circulating. To solve this problem, a 24-inch steel conductor casing was inserted on the drill rig side of the alignment to allow drilling fluid returns. Later when the TM1-T
5 shale formation was reached, a ribbon of hard sandstone was encountered that greatly slowed the drilling operations and eventually overworked the mud motor being used and caused it to fail. Equipment Problems and harsh winter temperatures aside, HDD Specialists eventually completed the drilling operations with an excellent bore-hole. Initial recommendations from Underground Solutions included ballasting the pipe during pull-back in order to help the pipe sit down in the bore-hole and reduce drag on the top of the pipe through the bore-hole, but the topography of the laydown area with its rolling hills made ballasting the pipeline very difficult (see Figures 3 and 4). Even without the ability to ballast the pipe, HDD Specialists felt confident that they had a very good hole and the strength of the 12-inch DR14 FPVCP was more than sufficient for the task and continued with pullback operations. Roughly eight hours later the pipe was fully installed and pull forces never exceeded 40,000 lbs compared to the safe allowable pull force for the FPVCP pipe section of 101,600 lbs. Figure 3. Laydown area for North Tank Crossing showing the staged pipe string alignment. Figure 4. Front end of pipe string aligned with the insertion point towards the water s edge. TM1-T
6 4. LOG LANE CROSSING PIPE REPLACEMENT Following the successful 2,400 LF emergency HDD installation for the North Tank Crossing, MCQWD now had three of its four water mains serving residents north of the South Platte River. The public health risk was now addressed affording them time to procure the replacement Log Lane Village crossing with a typical design, bid, build method (see Figure 5). While additional time was available, schedule was a factor to complete the work prior to increased demands in the spring that required the Log Lane crossing to be operational. Still, MCQWD was very impressed with the success and ease of the North Tank Crossing HDD installation and chose to repeat an HDD installation for Log Lane. As MCQWD s district engineer, the Farnsworth Group, Inc. (Farnsworth) in Fort Collins, CO was authorized to proceed with design and bid documents. This process followed MCQWD s normal process for construction projects along with additional requirements to qualify for FEMA s reimbursement. Figure 5. Exposed water main at Log Lane as damaged in the flood, shown after the flood waters had subsided. The design process followed normal procedures including topographic survey of the crossing that was partially hampered by high South Platte River flows at the time of the survey. From the survey, a new alignment was identified to be off-set from the existing line which accommodated HDD working areas, pipe fusing operations, and tie-ins to the existing waterline (see Figure 6). Farnsworth designed the bore path to be a U-shaped profile with smooth transitions and curves well above the 275 foot minimum allowable bending radius of the 12-inch FPVCP. The profile of the pipeline was designed to maintain a minimum depth below the existing river bottom of 30 feet which resulted in a proposed bore of approximately 1,900 LF. As with the emergency North Tank Crossing, overall project schedule duration was reduced by the use of historical well information for soil conditions in the area. This information revealed similar soil conditions with poorly graded sands and gravels near the surface as well as a shale formation. With an acceptable alignment selected, design calculations were completed to confirm the 12-inch FPVCP that MCQWD had purchased at the same time as the North Tank Crossing project would withstand the calculated pull force for the design alignment, depth and anticipated soil conditions. These calculations followed ASTM F (ASTM, 2011) guidance and was found to provide adequate capacity for the crossing. To complete the design, waterline filling, testing and disinfection factors were considered and incorporated into the tie-in locations. The bid documents where assembled and the project was advertised for bid. Four contractors submitted proposals for the crossing replacement and MCQWD awarded the contract to Klevin Construction of Tempe, AZ. While Kleven Construction was an experienced HDD contractor, this was their first project that included the use of FPVCP. Kleven Construction mobilized in March of 2014 to begin the Log Lane Crossing. Unlike the North Tank Crossing, gravel at the surface was not an issue and pilot hole work was completed in relatively short order. As with all HDD applications, accurate pilot hole information is critical to the process and dictates the final alignment of the bore hole and pipe. Accurate steering can be made more difficult with river crossings depending on the technology used. This was the case at Log Lane as during the month of March, river flows required that a section of the bore hole could not be recorded. While Kleven continued with back reaming operations, pilot hole asbuilt information was being analyzed for conformance with the contract documents. Review by the Farnsworth found a potential area of concern in which the as-built profile deviated from the required profile. This issue appeared to be a hump or high point in the profile creating a location of potential increased pull forces during installation and an unplanned high point in the final pipeline. Further investigation found this location to be at the area of missing TM1-T
7 information under the high flow sections of the crossing. This information was immediately communicated to the contractor and a meeting was held to review the issue. Figure 6. Log Lane Village Crossing Plan, shown schematically. While Klevin Construction understood the concern with the as-built profile, they were confident that a good bore hole existed based on the pull forces experienced during the back reaming process. To ensure an acceptable profile, it was decided that a new as-built of the bore would be performed. This as-built was completed at a time when other work along the South Platte River had diverted the flows to the south portion of the river allowing for as-built information to be recorded in the previously missed section. Immediate review of the new as-built proved that while the profile did gain elevation then flatten, no actual hump existed in the profile. Based on this analysis, the bore was approved for pipe installation. Taking place concurrently with the back reaming and profile review process was the assembly of the 1,900 LF of pipe. Due to the ease of completing the pilot hole and back reaming process, this activity became an item of concern in which the bore hole would be ready for pipe prior to completion of the joining and staging process. To accommodate the shortened schedule, an additional fusion machine was mobilized to the site to increase productivity to complete this task and ensure no delay between completion of the bore hole and pipe installation. With the cooperation and teamwork between MCQWD, Klevin Construction, Underground Solutions, Inc., who performed the pipe assembly, and Farnsworth, all pieces of the puzzle came together and pull-back operations commenced. The Log Lane crossing pull-back was completed in approximately six hours under minimal pull forces. 5. CONCLUSIONS As with several water districts in Colorado, the flooding events of September, 2013 caused significant damage to their infrastructure. MCQWD sustained heavy casualties as part of this flooding event that needed to be remediated under an emergency basis. HDD technology proved to be an effective tool to economically and efficiently restore service to customers with limited disturbance to the surrounding environment for MCQWD. Foresight of the District in procuring the materials for both crossings and teamwork between agencies, contractors, suppliers and engineers, proves that having proper communication and a common goal can result in a successful project in both negotiated and hard bid applications. TM1-T
8 7. REFERENCES ASTM (2011), Standard Guide for Use of Maxi-Horizontal Directional Drilling for Placement of Polyethylene Pipe or Conduit Under Obstacles, Including River Crossings, ASTM International, West Conshohocken, PA. AWWA C (2007), Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. Through 12 In. (100 mm Through 300 mm), for Water Transmission and Distribution, American Water Works Association, Denver, CO. AWWA C (2010), Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 14 In. Through 48 In. (350 mm Through 1,200 mm), American Water Works Association, Denver, CO. TM1-T
LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM
North American Society for Trenchless Technology (NASTT) No-Dig Show 2010 Chicago, Illinois May 2-7, 2010 Paper D-4-02 LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE
New advances in planning a bore Software helps take out the guesswork
New advances in planning a bore Software helps take out the guesswork Written By: Greg Ehm, Technical Writer Two Rivers Marketing, Des Moines, Iowa Provided By: Vermeer Corporation Pella, Iowa Horizontal
Can You See It Coming? Examining and Mitigating the Common Causes of HDD Failures
North American Society for Trenchless Technology (NASTT) NASTT s 2014 No-Dig Show Orlando, Florida April 13-17, 2014 TM1-T2-04 Can You See It Coming? Examining and Mitigating the Common Causes of HDD Failures
DETERMINATION OF SAFE PULLING LOADS ON FUSIBLE PVC PIPE DURING HORIZONTAL DIRECTIONAL DRILLING INSTALLATIONS
North American Society for Trenchless Technology 2008 No-Dig Conference & Exhibition Dallas, Texas April 27 May 2, 2008 DETERMINATION OF SAFE PULLING LOADS ON FUSIBLE PVC PIPE DURING HORIZONTAL DIRECTIONAL
Utilizing Trenchless Technology to Achieve Watermain Asset Management Objectives
North American Society for Trenchless Technology (NASTT) NASTT s 2015 No-Dig Show Denver, Colorado March 15-19, 2015 MM-T6-05 Utilizing Trenchless Technology to Achieve Watermain Asset Management Objectives
Carlon Bore-Gard and Boreable Multi-Gard Raceway
Carlon Bore-Gard and Boreable Multi-Gard Raceway Bore-Gard Schedule 40 Bore-Gard Schedule 80 Boreable Multi-Gard Type 40 www.carlonsales.com 231 Bore-Gard Trenchless Raceway Carlon Bore-Gard Trenchless
The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL
SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL PART 1 - GENERAL 1.1 WORK INCLUDED IN THIS SECTION A. The WORK of this Section includes the repair, demolition, and disposal of asbestos
Dewatering - Time and Cost Relief by way of Trenchless Construction
North American Society for Trenchless Technology (NASTT) NASTT s 2015 No-Dig Show Denver, Colorado March 15-19, 2015 TA-T3-04 Dewatering - Time and Cost Relief by way of Trenchless Construction Jenn Stillman,
Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam
Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam Education Master of Business Administration University of Houston, 1985 Bachelor of Science, Civil Engineering University
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
1.3.2 Method of construction and restoration of existing water service connections. This shall include:
1.0 GENERAL 1.1 DESCRIPTION: This specification shall cover the rehabilitation of existing water lines using the GRUNDOCRACK PIPE BURSTING SYSTEM. Pipe bursting is a system by which the pneumatic bursting
REHABILITATION OF THE LONG WHARF SEWER FORCE MAIN USING SLIPLINING METHODOLOGY IN NEWPORT, RHODE ISLAND
North American Society for Trenchless Technology (NASTT) No-Dig Show 2011 Washington, D.C. March 27-31, 2011 Paper A-5-04 REHABILITATION OF THE LONG WHARF SEWER FORCE MAIN USING SLIPLINING METHODOLOGY
PLANNING CAREFUL NORTH VANCOUVER PIPE BURST REQUIRES
WATER & SEWER REHAB TECHNOLOGIES NORTH VANCOUVER PIPE BURST REQUIRES CAREFUL PLANNING Close proximity to storage silos, poor ground conditions and clogged storm sewer pipe puts trenchless contractor to
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Jeff R. Hill, P.E. Hayward Baker Inc. 111 W. Port Plaza Drive Suite 600 St. Louis, MO 63146 314-542-3040 [email protected]
SANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
SECTION 02845 GUARDRAILS
SECTION 02845 GUARDRAILS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals necessary and repair, replace or install all types of guardrails as specified herein
SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
SECTION 5: SANITARY SEWER SYSTEM DESIGN
SECTION 5: SANITARY SEWER SYSTEM DESIGN 5.01 GENERAL Sanitary sewer improvements shall be designed to serve the ultimate level of City development as defined in the General Plan and the Wastewater Facilities
Greensboro s Pilot Program for Water Pipe Bursting Leads to Expanded City Wide Program
North American Society for Trenchless Technology (NASTT) NASTT s 2013 No-Dig Show Sacramento, California March 3-7, 2013 TA-T3-05 Greensboro s Pilot Program for Water Pipe Bursting Leads to Expanded City
Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe
Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe 1. GENERAL The following supplemental sewer main specifications are intended to address the installation of high-density polyethylene
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
SECTION 603 SANITARY SEWER FORCE MAINS
SECTION 603 SANITARY SEWER FORCE MAINS 1. GENERAL Pipelines for sanitary sewer force main systems shall conform to the following specifications and shall be installed at the locations indicated on the
WEFTEC.06. Kent Von Aspern,* Collins Orton** *Carollo Engineers 2700 Ygnacio Valley Rd Suite 300 Walnut Creek, CA 94598
Lessons Learned from Large Diameter Sanitary Sewer Pipe Bursting Project: Conversion of Abandoned Gravity Sewer Main Into Upsized Sanitary Force Main South San Francisco, CA Kent Von Aspern,* Collins Orton**
SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
Emerging Technologies in Wastewater Collection Systems
Keville Enterprises Emerging Technologies in Wastewater Collection Systems Douglas McCutchen, CCM Brian Karmasin, P.E., BCEE CMAA Annual Conference Oct 2008 San Francisco, California Today s s Presentation
Section 02415. Installation of pipe and casing for sanitary sewer by methods of augering.
ITY OF PRLN UGRING PIP OR SING FOR SWRS Section 02415 UGRING PIP OR SING FOR SWRS 1.0 G N R L 1.01 STION INLUS Installation of pipe and casing for sanitary sewer by methods of augering. References to Technical
TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe
TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe TN 5.18 October 2015 In sanitary sewer, it is often necessary to use trenchless technology methods to install a casing pipe under high volume roads,
High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines
High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines Jeff Schell General Manager United Pipeline Middle East, Inc. Introduction HDPE Liners A cost effective and environmentally beneficial
SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.
SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION
DIRECTIONAL DRILLING
DIRECTIONAL DRILLING 1. General. Installation of pipelines through the levee embankment using directional drilling technology is prohibited. Installation of pipelines through a flood control project foundation
Water Main Lining A Sustainable Alternative to Open Cut Replacement
Water Main Lining A Sustainable Alternative to Open Cut Replacement Sean O Dell, PE Baxter & Woodman, Inc. B&W Client Seminar, Crystal Lake May 1, 2014 Agenda Why, What, When, Where, Who, How Reduction
Installation of Large Diameter Buried Pipes
Installation of Large Diameter Buried Pipes Sullivan (Sully) Curran P. E., Executive Director I. Introduction and Scope There is an ongoing need to provide designers, specifiers, engineers, consultants
DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES 33 00 00 SITE UTILITIES
SECTION INCLUDES Domestic Water Fire Water Service Water Well Sanitary Sewer Storm Drains Foundation Drainage RELATED SECTIONS 03 30 00 Concrete 21 00 00 Fire Suppression - Sprinklers 22 00 00 Plumbing
Sewer Rehabilitation Design Requirements
Sanitary Sewer Overflow (SSO) Control and Wastewater Facilities Program Sewer Rehabilitation Design Requirements City of Baton Rouge/Parish of East Baton Rouge Department of Public Works Submitted by Prepared
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe
Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe As the Environmental Protection Agency tightens groundwater quality regulations, old leaking sewers lines made of pipe clay,
AXIS system used to install gravity flow sewer Laser-guided boring technology capable of pinpoint, on-grade accuracy
AXIS system used to install gravity flow sewer Laser-guided boring technology capable of pinpoint, on-grade accuracy The City of Kitchener, Ontario, Canada, was in a dilemma. After repeated breakdowns
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
32-02.05 Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.
SECTION 32: SANITARY SEWER INSTALLATION 32-01 SCOPE. The Work shall consist of furnishing and installing sewer mains, manholes, laterals, cleanout fittings and appurtenances; and testing, flushing and
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
Frequently Asked Transmission Pipeline Questions
Frequently Asked Transmission Pipeline Questions Who is PennEast, LLC? PennEast was formed by the partnership of AGL Resources, NJR Pipeline Company, South Jersey Industries and UGI Energy Services (UGIES).
SECTION 02763 POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.
SECTION 02763 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Repairs to existing sewer lines by replacing short lengths of failed pipe. 1.02 UNIT PRICES A. Measurement for point repairs is on a unit price
EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS
SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS PART 1: GENERAL 1.01 SECTION INCLUDES Furnishing and installing up to 16-inch high density polyethylene (HDPE) pipe and fittings for
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
OAR52 A-1 (September, 1981)
APPENDIX A SEWER PIPELINES (1) MINIMUM REQUIREMENTS FOR SEWER - PIPELINES (a) Capacity: Sewers shall be of such diameter as to pass without overflow, bypass, or back flow onto damageable property of a
APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE
APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE JURISDICTION OF ALBERTA TRANSPORTATION 1.0 Application Procedures 2.0
725-R-599 PIPE LINING. (Revised 05-01-12) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE
PIPE LINING (Revised 05-01-12) The Standard Specifications are revised as follows: SECTION 725, DELETE LINES 1 THRU 317. SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING
SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes)
SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes) Maintenance Office Administrative Office Billing Office 530-426-7802 530-426-7800 916-332-4872
12/8/2014. Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA.
Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA. 1 Pipe Bursting A Mature and Diverse Trenchless Technology December 10, 2014 1:00 3:00 pm Eastern How to Participate Today
Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL
155 E. Front Street (rear) Lititz, PA 17543 Phone (717) 625-1930 Fax (717) 625-1931 Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL CONSTRUCTION SPECIFICATIONS AND DETAILS
Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS
Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS TABLE OF CONTENTS I. RULES AND REGULATIONS A. TABLE OF CONTENTS... 2 B. TERMS AND DEFINITIONS... 3 C. DEVELOPER S/CONTRACTOR S RESPONSIBILITIES...
2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS
2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS Water system improvements proposed for inclusion into Western s service area shall be designed in accordance with all appropriate AWWA standards, include
High Strain Dynamic Load Testing of Drilled Shafts
Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain
SECTION 33 31 00.11 GRAVITY SANITARY SEWERS
SECTION 33 31 00.11 GRAVITY SANITARY SEWERS PART 1: GENERAL 1.01 SCOPE A. Gravity sanitary sewers and appurtenances. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 Submittals. B. Submit
Specifications for Residential Property Owners Connection to New Public Sewer
Specifications for Residential Property Owners Connection to New Public Sewer Spalding Tract property owners are required to connect to the community sewer system when construction is complete and the
SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily
LARGE DIAMETER PIPELINE INNOVATIVE FAST TRACKED REPAIR
LARGE DIAMETER PIPELINE INNOVATIVE FAST TRACKED REPAIR ABSTRACT Phil Hubbard, P.E., HRSD Paul Wilson, P.E., Brown and Caldwell* Mark Harber, P.E., Brown and Caldwell *301 Bendix Road, Suite 400 Virginia
Section 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8 with PCS unit segmental retaining wall
SECTION 31 20 00 EARTH MOVING
SECTION 31 20 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for excavating, filling, and grading for earthwork at Parking Structure, new exit stair and as required to
53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:
Division 53: Slip-Lining of Existing Sewer Line 53.01 GENERAL: This section includes all labor, materials, transportation, equipment necessary to rehabilitate by means of Instituform deteriorated sections
San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS
San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS 854.1 DESCRIPTION: This item shall govern sanitary sewer laterals installed in accordance with these
Section 402. STORM SEWERS
402.02 Section 402. STORM SEWERS 402.01. Description. This work consists of constructing storm sewers of the size and class required, including excavation, bedding, and backfill. 402.02. Materials. Provide
Sewer Line Rehabilitation
1.0 GENERAL 1.1 DESCRIPTION: This specification shall cover the rehabilitation of existing sanitary sewers using the GRUNDOCRACK PIPE BURSTING SYSTEM. Pipe bursting is a system by which the pneumatic bursting
The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:
Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section
PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY
PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY Cured-In-Place Pipe Pressure & Gravity Lines Pipe Splitting Trenchless Pipe Replacement EcoCast Advanced
Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014
Relining of Water Mains with Flexible High Pressure Pipelines Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014 Aging water main infrastructure The American Society of Civil Engineers
(1) Discuss the determination of the need for public visitation. Visitor center density within 100 miles.
Chapter 4 Specifications Designs 3. Visitors Centers 3. Visitors Centers. The Introduction (Chapter 1) for these design data collection guidelines contains additional information concerning: preparing
TENNESSEE GAS PIPELINE COMPANY, L.L.C.
TENNESSEE GAS PIPELINE COMPANY, L.L.C. HYDROLOGIC & HYDRAULIC CALCULATIONS FOR WATERBODIES CROSSED BY CONNECTICUT PIPELINE EXPANSION PROJECT CONNECTICUT LOOP Submitted by: Tennessee Gas Pipeline Company,
Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority
Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority Abstract The United States Virgin Islands Waste Management Authority
Prattsville Berm Removal Project. 1.0 Project Location
Prattsville Berm Removal Project 1.0 Project Location The project site is located between the New York State Route 23 Bridge over the Schoharie Creek and the Schoharie Reservoir. The restoration plan encompassed
Drilling Problems. pull
Drilling Problems Pipe Sticking Lost Circulation Hole Deviation Pipe Failures Borehole Instability Mud Contamination Formation Damage Hole Cleaning H S General Equipment & Personnel Pipe Sticking Can not
SECTION 3 SANITARY SEWER DESIGN
SECTION 3 SANITARY SEWER DESIGN 3.1 GENERAL DESIGN CRITERIA 3.1.1 Requirement for Sanitary Sewer 3.1.2 Design Approval 3.1.3 IEPA Permit Required 3.1.4 Differentiation Between Public and Private Sanitary
TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe
TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe TN 5.14 February 2010 Introduction It may be at times necessary, in an aging infrastructure, to rehabilitate drainage and sanitary lines
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Vintage TM unit segmental retaining wall (SRW)
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains
Beacon Hill Sewer District Standard Specifications
Beacon Hill Sewer District Standard Specifications Residential Gravity Side Sewer Including Design Criteria and Standard Construction Drawings Residential Gravity Side Sewer Design Criteria 1. Provisions
Selim BORA President www.summa.com.tr
ENERGY INVESTMENTS Summa was founded in 1989, in Ankara, Turkey by its honorary President Mr. Mete Bora in order to work as an international construction company. Summa, which is working in international
SECTION 10 WATER WELL SUPPLY 10.01 SCOPE OF WORK
10.01 SCOPE OF WORK The work covered by this section of the specifications consists in furnishing all labor, equipment and material necessary to perform the installation of a Type I water supply well per
MEMORANDUM: RECOMMENDATIONS FOR PIPE MATERIAL SELECTION
MEMORANDUM: RECOMMENDATIONS FOR PIPE MATERIAL SELECTION Moser and Associates Engineering for CDOT Region 6 Date: 9/30/10 Memorandum to File: Recommendations for Pipe Material Selection for Construction
Jackson Gulch Outlet Canal Rehabilitation Project
Jackson Gulch Outlet Canal Rehabilitation Project Preliminary Budgetary Estimate for Rehabilitation February 2004 Prepared for the Mancos Water Conservancy District Jackson Gulch Reservoir 42888 County
San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System
Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System An application for the construction or alteration of an individual subsurface sewage disposal system shall
SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER
Village of Shorewood, Wisconsin SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER Prepared By: Thomas A. Zoulek, P.E., LEED A.P. Vice President Mid City Plumbing & Heating
CONSTRUCTION OF NON-CIRCULAR SEWER REHABILITATION PROJECTS IN LOS ANGELES
North American Society for Trenchless Technology (NASTT) No-Dig Show 2010 Chicago, Illinois May 2-7, 2010 Paper C-4-04 CONSTRUCTION OF NON-CIRCULAR SEWER REHABILITATION PROJECTS IN LOS ANGELES Brad Jenson
Storm Sewer Trenchless Upgrade Alternatives and Recommendations
Storm Sewer Trenchless Upgrade Alternatives and Recommendations Background Approximately 1,930 feet of the 40-inch and 42-inch CMP storm sewer pipe from manhole M22 to manhole M12 will be evaluated for
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD 21.01 SCOPE: It is the intent of the Specification to define the approved methods and materials