National Home Builder - Name Wednesday, August 20, 2014 Regional Customer Care Manager 1234 Main Street Houston, Texas 77067

Lighthouse Engineering, L.L.C.

Lighthouse Engineering, L.L.C.

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

HEDDERMAN ENGINEERING, INC. Office , Fax

5006 Cherry Ridge Road Richmond, Texas LIMITATIONS AND DISCLAIMERS

Inspection of the exterior found a tree in the back yard and a tree in the front yard within influential distance from the residence foundation.

Simpson Engineering A state licensed engineering firm F-1607

REPORT OF FLOOR ELEVATIONS On Property Located at: Bordeaux Village Dallas TX JOB #11766

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

Chapter 9 Remedial Measures

SAMPLE REPORT. Convention regarding directions: Front faces the street, left and right are as seen from the street facing the house.

Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Texas Building Pros Foundation Repair Services

GOOD NEWS BUT NOT ALWAYS

HEDDERMAN ENGINEERING, INC Carrie Cove Ct., Spring, TX , fax

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

Steve Brinkman Alain Pinel Realtors 167 S San Antonio Road Los Altos, CA RE: Foundation Inspection for 162 Del Monte Ave. Los Altos, CA 94022

A RESIDENTIAL PROPERTY LOCATED AT xxxxxxxxxxxxxx, PASADENA, TX 77505

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

7 Crucial Questions to Ask Before Repairing Your Home s Foundation

FORENSIC INVESTIGATION QUESTIONNAIRE

STRUCTURAL ASSESSMENT

Building Condition Assessment: North Howard Street Baltimore, Maryland

14 September Sarah Zorn Planning and Economic Development 25 West Fourth Street, Ste St. Paul, MN 55102

HOME INSPECTION CHECKLIST

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

Vision Home Inspection

ELIGIBLE REPAIR PROJECT PARAMETERS

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

How To Repair A House

Residential Foundations and Basements

Spotting Structural Problems in a Home

Estimated Cost of Repair

December 24, SEDA Construction Attn: Ted Walker 2120 Corporate Square Boulevard Jacksonville, Florida 32216

Building Condition Assessment Report

Property Inspection Report

Page & Turnbull imagining change in historic environments through design, research, and technology

Foundation. Foundation

Exterior Elevated Elements Inspection Guidelines

Basement & Foundation Damage

SAMPLE INSPECTION REPORT PREPARED FOR: John Q Public

Criteria for the Inspection of and the Assessment of Residential Slab-on-Ground Foundations

I NI NP R Inspected Items

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Designed and Engineered to Perform

Structure Survey Findings:

Rehab Inspection Report Page 1

ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE

Photos showing the change in condition from 2006 to 2012 are located in Appendix A.

Inspecting to a higher standard.

Structural Assessment Report

PROPERTY INSPECTION REPORT

VILLAS OF TRADITIONS AT GREY OAKS

Name of course: Residential Construction Site Management (RCSM) Level 1

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Self-Home Inspection Checklist

StuccoSpec Moisture Testing Inspection

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

Pre-Drywall Inspection Report

A guide to preventing structural damage

PROPERTY INSPECTION REPORT

Building Condition Assessment: West Lexington Street Baltimore, Maryland

3 Masonry and Manufactured Stone (Interior and Exterior)

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

The minimum reinforcement for the stem wall is the placement of:

Metropolitan Builders Association Masonry & Concrete Standard

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

BUYER S GUIDE TO SLAB-ON-GROUND FOUNDATIONS

What Causes Foundation Leaking?

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

GUIDELINES FOR THE EVALUATION OF FOUNDATION MOVEMENT FOR RESIDENTIAL AND OTHER LOW-RISE BUILDINGS

HomeSpec REPORT SUMMARY

Melbourne balcony Assessments

All CDBG-DR Program Subrecipients. Texas General Land Office. Date: August 20, Damage Assessment Guidelines

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

March 19, Ms. Jean McDonald CAP Management th Street, Suite 1010 Denver, Colorado 80202

~ Tel: ~ Fax: SUBTERRANEAN TERMITE CONTROL SPECIFICATIONS TERMITE PROTECTION AGREEMENT

Structural Foundation System

Residential Decks. Planning and Development Services Department

New FHA Appraisal Reporting Requirements By TJ McCarthy, SRA, IFA

Soaker Hoses for Trees & Foundations. Patty Sipe Heads Up Sprinkler Company

Eco Solutions Pest Control - Sydney Tel PO Box 1289, Double Bay, Sydney NSW

FOR. by The Structural Committee of The Foundation Performance Association Houston, Texas. Document # FPA-SC-06-0

COMPREHENSIVE PROPERTY INSPECTIONS

BUILDER LIMITED WARRANTY COVERAGE

EAST LYME HIGH SCHOOL

PELHAM MEMORIAL HIGH SCHOOL STONE FAÇADE REPORT. November 2007

Home Management Checklist: Spring

Basement Moisture Problems

Inspection Item COMMENTS

State of Connecticut Department of Public Health RADON PROGRAM

Texas Premier Homes LIMITED BUILDER S WARRANTY COVERAGE

How To Prevent Water Damage To A Home

159 Morningside Avenue, Toronto

Windbrooke Townhome Association, Inc. Maintenance & Service Responsibility Chart

Transcription:

Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: Office@LighthouseEng.com Thursday, September 04, 2014 TO: Our Client RE: Engineering Evaluation Foundation Performance Anywhere in North Texas The following report constitutes the engineering opinion requested on the foundation of the subject residence. This report has been prepared in general accordance with the requirements of a Level B survey as defined by the Texas Chapter of the American Society of Civil Engineers (ASCE) and the Texas Board of Professional Engineers (http://texasce.affiniscape.com/associations/10803/files/repairguidelines.pdf). This report is provided for the exclusive use of the person or persons this report was prepared for as shown above. We have no contractual relationship with, or obligation to, any party other than the party for whom this report was prepared. The purpose of this inspection was to evaluate the foundation and determine what, if any, foundation repairs are necessary. The foundation was visually inspected and a floor elevation survey was performed. The opinions contained herein are based on the experience and judgment of the writer, as well as conditions observed without taking soil samples, performing plumbing leak tests, removing floor or wall coverings, or performing invasive tests or procedures. The opinions offered herein are based solely on the observations made at the time of the inspection, and do not take into consideration any changes in the condition of the foundation after that date. This report does not predict or warrant the future performance of the subject foundation. You are encouraged to review the Agreements and Limitations attached to the end of this report for other important limitations and standard recommendations. Observations This structure is a one - story wood framed structure with brick veneer and siding on the exterior. The home has a hip roof and composition shingles. The interior walls are drywall with various finishes over the drywall. The foundation is a pier and beam. The home was constructed in 1965 per the Dallas County Appraisal District Records. All directions in this report are annotated by left, right, front and rear as if looking at the front door. 2014 Lighthouse Engineering 214-577-1077 Page 1 of 6

Observations and Discussions: 1. Jason Conklin, Engineer (under the direct supervision of Mike Gandy, PE) physically inspected the above referenced residence to make an evaluation of the current foundation performance and to offer recommendations for repair, if needed. I performed a Level B engineering analysis as defined by the Texas Chapter of the ASCE. I made careful observations of the interior and exterior for signs of drainage and foundation distress. I performed an interior elevation survey as shown on Drawing No. 1001. 2. This engineering inspection was performed for the prospective buyer of the home. The home is listed on the real estate market. Photo 1: General view of the front of the home. 3. There were very few minor brickwork separations identified around the exterior of the home. 4. The perimeter of the home has gutters. It is recommended to routinely maintain gutters to ensure proper flow. The drainage around the home appeared to be adequate and no standing water was identified. 5. Large mature trees were identified in the front yard of the home. Photos 2 & 3: Large mature trees located in the front yard. 6. Numerous minor drywall separations were identified throughout the interior of the home. Most drywall separations appeared to be typical for a home of this age and location. 2014 Lighthouse Engineering 214-577-1077 Page 2 of 6

Photos 4 10: Minor drywall separations identified throughout the interior of the home. 7. Soils beneath the home were clean and dry and ventilation appears to be adequate to allow for proper airflow beneath the home. 2014 Lighthouse Engineering 214-577-1077 Page 3 of 6

Photos 11-13: Views beneath the home. 8. Minor signs of termite activity were identified in numerous locations beneath the home. No signs of active termite activity were identified at this time. Photo 14: Signs of previous termite activity. Interior Elevation Survey Interior floor elevations were taken with a Technidea Pro-2000 Ziplevel. Elevations were recorded to the nearest 0.1-inch throughout the home. A benchmark of was established near the main entry area and is shown on Drawing No. 1001 with a star. An adjustment was made for floor coverings if they were a different elevation than the floor covering at the benchmark location. Elevation differentials varied by a maximum of 1.6 vertical inches in thirty-two (32) horizontal feet. It should be noted that the elevation measurements include effects of elevation variation in the original construction which normally are 2014 Lighthouse Engineering 214-577-1077 Page 4 of 6

inches to 1.0 inches. A sketch of the house with the elevations is attached as Drawing No. 1001. Conclusions An elevation survey was performed on the home and the cosmetic damage was reviewed to evaluate the performance of the foundation. The soil where the home is located has high shrink swell capacity. This soil can heave or settle depending on the moisture content in the soil. Some minor movement of the exterior driveways and sidewalks should be expected. Recommendations 1. Maintain a watering program in the dry months of the year to prevent the soil around the home from drying and cracking. If soaker hoses are used, place the soaker hoses 1 2 away from the foundation and run for 30 60 minutes every other day as needed. Do not over water the foundation; this can be as detrimental as under watering. 2014 Lighthouse Engineering 214-577-1077 Page 5 of 6

Agreements and Limitations Use of this report for any reason implies consent to all agreements and limitations of this report. This report is the professional opinion of Lighthouse Engineering, LLC and is based upon a limited evaluation of the property. This report is provided for the exclusive use of the addressee. We have no contractual relationship with, or obligation to, any party other than the addressee of this report. This report does not constitute a structural warranty or performance contract with the purchaser of this report to or with any other party. It only states conditions observed at the time of the inspection. The evaluation of the property included a visual examination of the exposed interior and exterior finishes of the structure and the ground surfaces adjacent to the structure and to the taking of relative floor elevations. The taking and testing of soil samples was not included. Unless written in the report, the original design drawings and any design conditions were not known. Determination of construction to Building Code is best done during the original construction and is not a part of this evaluation. Testing for plumbing leaks was not performed but is recommended after foundation work is performed. It is possible that future repairs could be required for the subject foundation. This evaluation only addresses the current condition of the foundation. Lighthouse Engineering, LLC does not offer or imply any warranty for the repairs or for the repair company s acts or omissions or for any other person conducting the repairs. The fee collected is for this inspection only. Additional engineering services are available at an additional cost. Requests for these services must be made in a timely manner before commencement of work. Please contact this office for additional inspection scheduling and fee arrangements. Sincerely, Michael Gandy, P.E. 9/4/2014 Registered Engineering Firm F-9334 2014 Lighthouse Engineering 214-577-1077 Page 6 of 6

THIS REPORT DOES NOT PREDICT OR WARRANT THE FUTURE PERFORMANCE OF THE FOUNDATION WOOD DECK WOOD DECK GAR F/P - 0.8 0.8 0.8 - - - - - - - -0.1 1.2 0.8 0.1 0.5 DATE 1.0 0.8 0.8 Lighthouse Engineering BENCHMARK ELEVATION 0 INCHES ELEVATIONS ARE SHOWN IN TENTHS OF AN INCH Michael Gandy, P.E. Phone: 214-577-1077 E-Mail: MikeGandy@LighthouseEng.com Registered Engineering Firm F-9334

THIS REPORT DOES NOT PREDICT OR WARRANT THE FUTURE PERFORMANCE OF THE FOUNDATION WOOD DECK WOOD DECK GAR F/P DATE Lighthouse Engineering BENCHMARK ELEVATION 0 INCHES ELEVATIONS ARE SHOWN IN TENTHS OF AN INCH Michael Gandy, P.E. Phone: 214-577-1077 E-Mail: MikeGandy@LighthouseEng.com Registered Engineering Firm F-9334