GPS NTP TIME SERVER Rack Version V2.2x



Similar documents
GPS NTP TIME SERVER Rack Version V2

GPS NTP Time Server for Intranet Networks DIN RAIL Version

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

1 Serial RS232 to Ethernet Adapter Installation Guide

Indoor / Outdoor Antenna

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Energy Communication Unit (ECU)

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

T200, PTP/IEEE 1588 Grandmaster Clock and

3.5 EXTERNAL NETWORK HDD. User s Manual

Application & Quick-Start Guide

II Intelligent PC/CAN Interface. Manual

HDMI over IP Broadcasting System ITEM NO.: HE05BT, HE05BER HDMI Matrix over IP Broadcasting

Debugging Network Communications. 1 Check the Network Cabling

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Olson Electronics Remote Power Monitoring Meter

Link Link sys E3000 sys RE1000

Network Management Card. User Manual

SNMP Web Management. User s Manual For SNMP Web Card/Box

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

LAN CONTROLLER instruction from 2.30

vyacht Wifi Router vyacht yacht automation About this manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Energy Communication Unit (ECU)

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Temperature Alert. LAN-based Temperature and Humidity Data Logger

T3 Mux M13 Multiplexer

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

Expert Power Control NET 4x 8212 / 8213

Firewall VPN Router. Quick Installation Guide M73-APO09-380

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

IX Support Tool Setting Manual

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Chapter 7 Troubleshooting

User Manual. EtherUSB

Installation and start-up guide NETA-21 remote monitoring tool

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

LBNP RS-232/485/422 serial device server. User manual

Innovative Electronics for a Changing World INDEX

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

RS-232/422/485, Power over Ethernet

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Broadband Router ESG-103. User s Guide

Application software. IP/KNX Interface Electrical / Mechanical characteristics : see product information. Order number. TP device RF devices

8/16-Port IP KVM Switch IKVM-8010 / IKVM Quick Installation Guide

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

WIZ-Embedded WebServer User s Manual (Ver. 1.0)

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Troubleshooting Guide

User Guide Reflow Toaster Oven Controller

How to Log On Main Screen Control Console Menus How to Log On Summary Page Navigation Menu... 29

WLAN Outdoor CPE For 2.4G. Quick Installation Guide

Wireless Router Setup Manual

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

Loop-IP6702 TDMoEthernet

Mobile Mapping. VZ-400 Conversion to a Mobile Platform Guide. By: Joshua I France. Riegl USA

Ethernet Port Quick Start Manual

1ZSC ABH en. Intelligent monitoring system, type TEC Installation and commissioning guide

GTS-4E Hardware User Manual. Version: V1.1.0 Date:

Installation & Operation Manual

Krontek. KT2000 GPS SNTP Timeserver

Internet-bridge XPort

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Powerware Environmental Rack Monitor User s Guide

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Getting Started Guide with WIZ550web

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Multi-Homing Dual WAN Firewall Router

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

SecureLinx Spider Duo Quick Start Guide

Application program usage. Functional description. Note. Note. instabus EIB Application Program Description. August CO IP-Interface

1.44 kw Programmable DC Power Supplies XLN Series

GV-Data Capture V3 Series User's Manual

Setting Up the ZigBee Ethernet Gateway

sat-nms SMU Signal Management Unit

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Title Page Web/SNMP Management SmartSlot Card

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual

RCI Web Server User s Manual RCI P/N: FP-SER-ETH-SERVR2

BROADBAND INTERNET ROUTER USER S MANUAL. Version Page 1 of 13 -

Chapter 4 Management. Viewing the Activity Log

Transcription:

GPS NTP TIME SERVER Rack Version V2.2x Device Description: GPS NTP Time Server is designed to synchronize local time and date of network devices such as PCs, routers. Devices synchronize their local time over the Ethernet using the NTP V3 protocol. (Network Time Protocol) The NTP Server is linked to the atomic cesium standard, placed in NIST (National Institute of Standards and Technology) over the GPS system. The Time Server consists of: - server two processor electronics, mounted in standard 19 / 1U case. - external GPS receiver in waterproof case. Server 19 case is mounting in the server room usually. GPS receiver with antenna in outdoor waterproof case IP-65 are mounted. Connection between external GPS receiver and server is made through the standard TP twisted pair cable up to 200m. - 1 -

System Topology: Time server consist as two components: Main Time Server rack case and IP65 water proof external GPS receiver with active antenna. 19" RACK Server External GPS receiver Twisted Pair cable max 200m Ethernet: 10 Base T, RJ 45 connector 10 MBit RX polarity: automatic Technical specifications ICMP: implemented Gateway: implemented, user configurable DHCP: not allowed MAC address: configurable Ethernet mask: configurale GPS External receiver with active antenna Powered from server Output protocol: NMEA Baudrate: 9600Bps PPS pulse: 1sec Cable: - 1 twisted pair for NMEA data - 1 twisted pair for PPS pulse - 2 wire for power Power: 9..12V DC Current consumption: 300mA max cable length: 200m NTP protocol: Time Accuracy Built in NTP v3 security keys: not implemented NTP Time stamp resolution: 13usec In UTC FIX state max error: 300 nsec / 1sec - due to built in NTP time stamp resolution 13 µsec device network accuracy = 13 µsec Without GPS UTC FIX state: max error: +/- 2ppm approx: 5sec/month in temperature range: 0..40 C - 2 -

SNMP protocol Main processor GPS processor Built in SNMP traps, server produce and send SNMP traps to dedicated Ethernet Device, - on every changes the number of satellites, - UTC fix changes - GPS receiver failures RISC UBICOM IP2022 120 MHz / for Ethernet connectivity 10BaseT Microchip RISC processor 20 Mhz for GPS messages, PPS pulses, LCD,buttons serving RTC Real Time Clock PHILIPS I2C, powered from lithium CELL CR2430, User Replaceable TCXO Thermal compensated quartz. Max Error: +/- 2ppm Reliability: Two processors watchdog-ing state every 1sec - BOR Brown Out Reset - POR power on reset - two internal watchdog independent watchdog timers Security User password to setup IP address, SNMP strings- community name... WEB interface Built in WEB server for dynamic CGI WEB pages - monitoring server status - setup time server - 4MBit dataflash Temperature ranges -25.. 55 'C Power: 100.. 250 V AC / 50Hz Display LCD 2x 16 chars Green BackLight Buttons JOG + ESC button for setup IP addresses and other values Server Case 19" rack / 1U Depth: 110mm - 3 -

Front Panel Buttons: On the front panel are mounted buttons: Rotary JOG: to change menus and increment / decrement input values SET: in the middle button of jog for enter to current menu or confirmation value ESC: to cancel current input value PPS and FIX LED Green PPS LED flashing in 1sec period. LED is connected directly to signal PPS from receiver. If PPS LED not flashing GPS receiver is not connected, in this case server is malfunction, and displayed will be message <PPS ERROR> After the power ON state, PPS Led will be not flashing approx 30..60 seconds. FIX LED must lighten continuously in UTC fix state, otherwise flashing. Configuration To change the current value of IP address, network mask, rotate JOG to choose appropriate value and by SET button it is possible to change current value. Before value changes user will be asked to password. Set the password holding UP/DN button and confirm by SET. Current password is delivered in documentation. Only after the correct password was entered, user can change values. Correct password is keeping in system in 5 minutes and next inputs in this time not required the password. After the entering value LCD processor write data to internal EPROM and sends to Ethernet processor with message: Send to IP2K MAC Address MAC consists of 6 bytes, but only 4 last bytes is possible to edit. Most significant 2-bytes are: 000, 003 LCD Messages <PPS Error> message reported with beep failures on PPS signal from GPS receiver. In this case check the cable to GPS receiver, check the fuse 500mA, mounted on back panel. Warning: immediately after the power ON state, this error message will be displayed approx 30 60seconds. <GPS DATA Error> message indicate the mismatch or missing the DATA from receiver. Check cable and fuse described as PPS error. <Send Setup Fail> on power on reset state, LCD processor sends the current setup to Ethernet IP2K processor. If the Ethernet processor not confirmed the values, this error message will be occurred. Note: without the PPS signal server is in the malfunction state. - 4 -

BACK PANEL FUSES: On the server back panel two fuses are mounted: Fuse for GPS external receiver: 500mA / T Type is recommended, fuse making protection the GPS power sources. Time server fuse: 500 ma/t to protection all power sources APP Connector Application connector DSUB15 Female for additional purposes. PPS signal output, RS485 timecode format 0 output 9600,N,8,1 GPS connector DSUB9 Female to connect the external GPS receiver. See the below picture for wiring external receiver. Ethernet connector 10BaseT RJ45 connector for ethernet connectivity. We note that to HUB or switch are needed NOTcrossed cable. For single PC CROSSED calbe. Back panel LEDs Red indicate Ethernet link activity, must be lightening on successful connectivity. Green LED blinking in 1sec interval, it mean reception datagram from LCD processor. - 5 -

External GPS receiver Time Server is delivered with waterproof IP-65 wall mounting external receiver and built in GPS active antenna also.. Mounted is GPS Receiver ANTARIS CHIPSET Operating temperatures: -45.. 85 C Receiver is powered from Time Server with voltage 12V DC / 300 ma through the Fuse 500mA on TimeServer Back Panel and FUSE 500mA/T on receiver daughter board also. See green box on board. Connection to server with twisted pair TP cable. 1 pair for DATA 1 pair for PPS signal + 2wire DC power max cable length: 200m It is strongly recommended to use standard TP cable for ethernet networks. It is low cost and good solution. On gps receiver board are mounted low impedance RS485 line drivers In the Time server are mounted 100 Ohm resistors on both lines: DATA, PPS, to minimize glitches and noise. GPS DATA baudrate: 9600b/sec Receiver output protocol: NMEA Connexant - 6 -

GPS External receiver wiring. POWER LED FUSE 500mA/T DATA PPS DC Power 9..35V - + PPS LED Twisted Pair Brown White-Brown Green White-Green Blue+WhiteBlue Red+WhiteRed CANON DSUB9 Male on the cable Blue+WhiteBlue 5 Red+WhiteRed 1 View from soldering side 9 6 Green White-Green White-Brown Brown Notes: PPS LED flashing in 1 second period approx 1 minute after the power ON. Connection is made by standard twisted pair cable TP, as used in Ethernet devices. Blue and WhiteBlue pair wires are shorted to make a lower resistance wire for DC power, also Red + WhiteRed. - 7 -

WEB Server Implementation In the Time Server is built in the WEB server for monitoring the status, setup network... All HTML, source files are located in 4MBit dataflash Its possible to replace source files by user by TFTP protocol. Main Page --- index.html --- to open main page of Time Server simply open your browser and into the address line write: http://192.168.0.25 Note: 192.168.0.25 is example, of course its needed the correct IP address of time server Browser will request the time server and it respond the main page: UTC server Time: Current UTC time. To obtain new values press reload browser button. UTC FIX Status: This information is loaded from the GPS receiver. In the NOT FIX state time Server closes the NTP protocol. Visible satellites: Indicate the total number of satellites from which are measurements making. GPS Receiver Status: Describes the status of GPS receiver, available messages are: - 8 -

O.K. PPS Error DATA Error Fatal Error Signal of PPS pulse missing, in this state check the cable from reciever Serial data from receiver missing, check the cable also GPS receiver is not connected, or malfunction, check the FUSE on back panel Server Name indicate the user replaceable Time Server Name. Name is used for SNMP traps. Server Location Describes the Time Server Location also for SNMP traps implementation System Status Up Time from last boot: indicate the elapsed time in seconds from last boot. PPS Length Length of the PPS pulse from GPS receiver. Value is rated in internal counter ticks with period 13usec. PPS length must be approx 77000 counts. Value must be strongly in constant length in every second. Otherwise time server closes the NTP protocol to 100 secs. Its mean that on cable from GPS receiver was some glitches detected. - 9 -

Number of Lost UTC FIX Indicate the total number of GPS UTC time FIX lost from last boot. If the GPS receiver has no fix utc, server close the NTP protocol. Num of NTP packet Received Total number of NTP packets received from any host. Num of NTP packet Rejected Total number of NTP packet rejected. NTP request packet from any host will be rejected on occurrences: - the UTC FIX state is failure UTC NOT FIX status - server detected the glitches on PPS signal, after the glitch time server clos the NTP ramp to 100 seconds. - 10 -

Network Setup HTML Page To Network setup page user will be navigate after the enter the correct password. Current time server values will be filled into the textboxes. Enter the 0.0.0.0 to Gateway textbox if the gateway is not used MAC address consists of last 4 bytes, first bytes are: 000, 003 in this example MAC = 0.3.100.45.147.212 After the <Submit> Time Server Reboot, it is needed to connect to Time Server with new values. All values will be written to the DataFlash memory and to LCD processor EEPROM also - 11 -

SNMP TRAP description Time server produce SNMP trap messages on every changes of internal status, where status byte is represented as 8-bit value: Status Byte: Bit Description 7 Not used 6 1 = PPS pulse from GPS receiver present 0 = PPS pulse missing / this is fatal error, GPS receiver is not connected 5 1 = GPS data message present 0 = GPS Data missing, Fatal error, GPS receiver is not connected or NMEA Data Message cable error 4 1 = UTC FIX status OK 0 = UTC FIX status error, in this state is NTP ramp closed and every NTP requirement from host will be rejected 3..0 The total number of GPS satellites measurements Note: bit 7 -MSB, 0 - LSB Max period of SNMP trap is 1sec in according to every 1second GPS sends Data message about UTC FIX status and number of satellites measurements. Looking to status byte the critical value is less then decimal value 112 = ( 0x70 hex notation ) Community default name is public, and can be modified by user from time server web page. OID description; Time server sends trap type 6, and 4 OIDs binding in message. OID (object identifier) Description 1.3.6.1.4.1.1316.55.3.1 Server Location <string> User can modify Server location string from web implementation Default value: gpsloc 1.3.6.1.4.1.1316.55.3.2 Server Name <string> Default value: gps 1.3.6.1.4.1.1316.55.3.3 Visible satellites <integer> Total number of measurements satellites 1.3.6.1.4.1.1316.55.3.4 Status Byte <integer> describes above - 12 -