GPS NTP TIME SERVER Rack Version V2



Similar documents
GPS NTP TIME SERVER Rack Version V2.2x

GPS NTP Time Server for Intranet Networks DIN RAIL Version

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Indoor / Outdoor Antenna

1 Serial RS232 to Ethernet Adapter Installation Guide

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

Debugging Network Communications. 1 Check the Network Cabling

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

T200, PTP/IEEE 1588 Grandmaster Clock and

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Application & Quick-Start Guide

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

II Intelligent PC/CAN Interface. Manual

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

SNMP Web Management. User s Manual For SNMP Web Card/Box

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

3.5 EXTERNAL NETWORK HDD. User s Manual

Krontek. KT2000 GPS SNTP Timeserver

T3 Mux M13 Multiplexer

LAN CONTROLLER instruction from 2.30

Expert Power Control NET 4x 8212 / 8213

Ethernet Port Quick Start Manual

HDMI over IP Broadcasting System ITEM NO.: HE05BT, HE05BER HDMI Matrix over IP Broadcasting

Link Link sys E3000 sys RE1000

User Manual. EtherUSB

Olson Electronics Remote Power Monitoring Meter

Network Management Card. User Manual

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Chapter 4 Management. Viewing the Activity Log

Chapter 3 Management. Remote Management

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Loop-IP6702 TDMoEthernet

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

WIZ-Embedded WebServer User s Manual (Ver. 1.0)

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

Energy Communication Unit (ECU)

Internet-bridge XPort

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

TDMoEthernet. Description

ethernet connection For more information about the printer's ethernet feature, click the topic below: ethernet lights network configuration page

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Network Power Manager. User Manual

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Installation and start-up guide NETA-21 remote monitoring tool

How to Log On Main Screen Control Console Menus How to Log On Summary Page Navigation Menu... 29

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Title Page Web/SNMP Management SmartSlot Card

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2


SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

Chapter 7 Troubleshooting

Using IDENT M System T with Modbus/TCP

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Getting Started Guide with WIZ550web

WLAN Outdoor CPE For 2.4G. Quick Installation Guide

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

SecureLinx Spider Duo Quick Start Guide

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

GV-Data Capture V3 Series User's Manual

Setup guide. point to point wall plate extenders

IX Support Tool Setting Manual

LBNP RS-232/485/422 serial device server. User manual

The basic mode for adjusting a time zone clock are primarily: 21, 24 and 51-1 (51-1 is for Alpha Characters) Entering Mode Programming

8/16-Port IP KVM Switch IKVM-8010 / IKVM Quick Installation Guide

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

UPS Network Interface. Quick InstallationGuide

How To Set Up A 9339 Voip Phone For The First Time

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

POWERED BY BLUE EARTH

Application software. IP/KNX Interface Electrical / Mechanical characteristics : see product information. Order number. TP device RF devices

sat-nms SMU Signal Management Unit

Troubleshooting Guide

Multi-Homing Dual WAN Firewall Router

HARTING mcon 1000 Introduction and features

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

MC1000. NTP Time Reference System. User Manual Version 2.1

User Manual. EtherUSB

Load Balance Router R258V

Broadband Router ESG-103. User s Guide

HWg-STE HWg-STE PoE MANUAL

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version Rev. B

Loop-IP6700 TDMoEthernet

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

Transcription:

GPS NTP TIME SERVER Rack Version V2 Description: Server is dedicated to synchronize network devices local time/date to Universal Time (UTC) Devices synchronizing own local time through the NTP V3 protocol. (Network Time Protocol) Time Server is joined to atomic cesium etalon nist.datum.com over the GPS satellite system. The main Time Server two processor electronics are placed in to the Rack 19" case / 1U, suitable to mount in to the server room. GPS receiver and antenna are mounted outdoor waterproof case IP-65. Connection between external GPS receiver and server is realized through the standard TP twisted pair cable up to 200m. System Topology: Time server consist as two components: Main Time Server rack case and IP65 water proof external GPS receiver with active antenna. - 1 -

Ethernet: 10 Base T, RJ 45 connector 10 MBit RX polarity: automatic Technical specifications ICMP: implemented Gateway: implemented, user configurable DHCP: not allowed MAC address: configurable Ethernet mask: configurale GPS External receiver with active antenna Powered from server Output protocol: ZODIAC Connexant Baudrate: 9600Bps PPS pulse: 1sec Cable: - 1 twisted pair for zodiac data - 1 twisted pair for PPS pulse - 2 wire for power Power: 9..12V DC Current consumption: 300mA max cable length: 200m NTP protocol: Time Accuracy SNMP protocol Main processor GPS processor Built in NTP/SNTP v3 unicast server/client - SNTP v4 broadcast on request only security keys: not implemented NTP Time stamp resolution: 13usec In UTC FIX state max error: 300 nsec / 1sec - due to built in NTP time stamp resolution 13 µsec device network accuracy = 13 µsec Without GPS UTC FIX state: max error: +/- 2ppm approx: 5sec/month in temperature range: 0..40 C Built in SNMP traps, server produce and send SNMP traps to dedicated Ethernet Device, - on every changes the number of satellites, - UTC fix changes - GPS receiver failures RISC UBICOM IP2022 120 MHz / for Ethernet connectivity 10BaseT Microchip RISC processor 20 Mhz for GPS messages, PPS pulses, LCD,buttons serving RTC Real Time Clock PHILIPS I2C, powered from lithium CELL CR2430, User Replaceable TCXO Thermal compensated quartz. Max Error: +/- 2ppm - 2 -

Reliability: Two processors watchdog-ing state every 1sec - BOR Brown Out Reset - POR power on reset - two internal watchdog independent watchdog timers Security User password to setup IP address, SNMP strings- community name... WEB interface Built in WEB server for dynamic CGI WEB pages - monitoring server status - setup time server - 4MBit dataflash Temperature ranges -25.. 55 'C Power: 100.. 250 V AC / 50Hz Display LCD 2x 16 chars Green BackLight Buttons 4x buttons on front panel - SET,ESC,UP,DN for setup IP addresses Server Case 19" rack / 1U Depth: 110mm - 3 -

Front Panel Buttons: On the front panel are mounted 4 buttons: SET: for enter to current menu UP,DN buttons to change menus and increment / decrement input values ESC: to cancell current input value PPS and FIX LED Green PPS LED flashing in 1sec period. LED is connected directly to signal PPS from receiver. If PPS LED not flashing GPS receiver is not connected, in this case server is malfunction, and displayed will be message <PPS ERROR> FIX LED must lighten continuously in UTC fix state, otherwise flashing. Configuration To change the current value of IP address, network mask, pressing the up/dn button choose appropriate value and by SET button it is possible to change current value. Before value changes user will be asked to password. Set the password holding UP/DN button and confirm by SET. Current password for the LCD Display is "013". Only after the correct password was entered, user can change values. Correct password is keeping in system in 5 minutes and next inputs in this time not required the password. After the entering value LCD processor write data to internal EPROM and sends to Ethernet processor with message: Send to IP2K MAC Address MAC consists of 6 bytes, but only 4 last bytes is possible to edit. Most significant 2-bytes are: 000, 003 LCD Messages <PPS Error> message reported with beep failures on PPS signal from GPS receiver. In this case check the cable to GPS receiver, check the fuse 500mA, mounted on back panel. Note: without the PPS signal server is in the malfunction state. <GPS DATA Error> message indicate the mismatch or missing the DATA from receiver. Check cable and fuse described as PPS error. <Send Setup Fail> on power on reset state, LCD processor sends the current setup to Ethernet IP2K processor. If the Ethernet processor not confirmed the values, this error message will be occurred. - 4 -

BACK PANEL FUSES: Mounted are two fuses: GPS receiver fuse: 500mA/T to make protection the GPS power sources. Time server fuse: 500 ma/t to protection all power sources APP Connector Application connector DSUB15 Female for additional purposes. PPS signal output, RS485 timecode format 0 output 9600,N,8,1 GPS connector DSUB9 Female to connect the external GPS receiver. See the below picture for wiring external receiver. Ethernet connector 10BaseT RJ45 connector for ethernet connectivity. We note that to HUB or switch are needed NOTcrossed cable. For single PC CROSSED calbe. Back panel LEDs Red indicate Ethernet link activity, must be lightening on successful connectivity. Green LED blinking in 1sec interval, it mean reception datagram from LCD processor. - 5 -

External GPS receiver Time Server is delivered with water proof IP 65 wall mounting external receiver and built in GPS active antenna.. Mounted JUPITER TU35-D410 Operating temperatures: -45.. 85 C Receiver is powered from Time Server. 12V DC / 300 ma through the Fuse 500mA on TimeServer Back Panel and FUSE 500mA/T on receiver daughter board also. See green box on board. Connection to server with twisted pair TP cable. 1 pair for DATA 1 pair for PPS signal + 2wire DC power max cable length: 200m It is strongly recommended to use standard TP cable for ethernet networks. It is low cost and good solution. On gps receiver board are mounted low impedance RS485 line drivers In the Time server are mounted 100 Ohm resistors on both lines: DATA, PPS, to minimize glitches and noise. GPS DATA baudrate: 9600b/sec Receiver output protocol: ZODIAC Connexant - 6 -

External receiver wiring - 7 -

WEB Server Implementation In the Time Server is built in the WEB server for monitoring the status, setup network... All HTML, source files are located in 4MBit dataflash Its possible to replace source files by user by TFTP protocol. Main Page --- index.html --- to open main page of Time Server simply open your browser and into the address line write: http://110.0.0.135 Note: 110.0.0.135 is example here, because it is the default IP Address, you need the real IP Address Browser will request the time server and it respond the main page: UTC server Time: Current UTC time. To obtain new values press reload browser button. UTC FIX Status: This information is loaded from the GPS receiver. In the NOT FIX state time Server closes the NTP protocol. Visible satellites: Indicate the total number of satellites from which are measurements making. GPS Receiver Status: Describes the status of GPS receiver, available messages are: O.K. PPS Error Signal of PPS pulse missing, in this state check the cable from reciever DATA Error Serial data from receiver missing, check the cable also Fatal Error GPS receiver is not connected, or malfunction, check the FUSE on back panel - 8 -

Server Name indicate the user replaceable Time Server Name. Name is used for SNMP traps. Server Location Describes the Time Server Location also for SNMP traps implementation System Status Up Time from last boot: indicate the elapsed time in seconds from last boot. PPS Length Length of the PPS pulse from GPS receiver. Value is rated in internal counter ticks with period 13usec. PPS length must be approx 77000 counts. Value must be strongly in constant length in every second. Otherwise time server closes the NTP protocol to 100 secs. Its mean that on cable from GPS receiver was some glitches detected. - 9 -

Number of Lost UTC FIX Indicate the total number of GPS UTC time FIX lost from last boot. If the GPS receiver has no fix utc, server close the NTP protocol. Num of NTP packet Received Total number of NTP packets received from any host. Num of NTP packet Rejected Total number of NTP packet rejected. NTP request packet from any host will be rejected on occurrences: - the UTC FIX state is failure UTC NOT FIX status - server detected the glitches on PPS signal, after the glitch time server clos the NTP ramp to 100 seconds. - 10 -

Network Setup HTML Page To Network setup page user will be navigate after the enter the correct password (Default="123456"). Current time server values will be filled into the textboxes. Enter the 0.0.0.0 to Gateway textbox if the gateway is not used MAC address consists of last 4 bytes, first bytes are: 000, 003 in this example MAC = 0.3.100.45.147.212 After the <Submit> Time Server Reboot, it is needed to connect to Time Server with new values. All values will be written to the DataFlash memory and to LCD processor EEPROM also - 11 -

SNMP TRAP description Time server produce SNMP trap messages on every changes of internal status, where status byte is represented as 8-bit value: Status Byte: Bit Description 7 Not used 6 1 = PPS pulse from GPS receiver present 0 = PPS pulse missing / this is fatal error, GPS receiver is not connected 5 1 = GPS data message present 0 = GPS Data missing, Fatal error, GPS receiver is not connected or Zodiac Data Message cable error 4 1 = UTC FIX status OK 0 = UTC FIX status error, in this state is NTP ramp closed and every NTP requirement from host will be rejected 3..0 The total number of GPS satellites measurements Note: bit 7 -MSB, 0 - LSB Max period of SNMP trap is 1sec in according to every 1second GPS sends Data message about UTC FIX status and number of satellites measurements. Looking to status byte the critical value is less then decimal value 112 = ( 0x70 hex notation ) Community default name is public, and can be modified by user from time server web page. OID description; Time server sends trap type 6, and 4 OIDs binding in message. OID (object identifier) Description 1.3.6.1.4.1.1316.55.3.1 Server Location <string> User can modify Server location string from web implementation Default value: gpsloc 1.3.6.1.4.1.1316.55.3.2 Server Name <string> Default value: gps 1.3.6.1.4.1.1316.55.3.3 Visible satellites <integer> Total number of measurements satellites 1.3.6.1.4.1.1316.55.3.4 Status Byte <integer> describes above - 12 -

NOTES: - 13 -