Data Centre alwas protected always up and running.



Similar documents
Maximum uptime and optimum fire safety for your data center

Maximum uptime and optimum fire safety for your data center

Data center solutions from Siemens. For the factories of the 21 st century. siemens.com/datacenters

Potential problems with computer hard disks when fire extinguishing systems are released

How can I protect valuable assets from fire and ensure business continuity?

INERGEN Acoustics Testing Position Paper

Fire Protection Options for Data Centres

Maximum uptime thanks to integrated data center solutions from Siemens

BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

What guarantees optimal business continuity for our clean room?

Data Center Infrastructure & Managed Services Outline

How intelligent must an extinguishing solution be to keep fire virtual?

White Paper: Server Room Environmental Monitoring

Begin using tomorrow s security features today.

Disruptions to hard disk drives caused by inert gas extinguishing systems analysis and measures for the safe operation of storage systems

12 Things Facility Managers Need to Know About Critical Power System Installation

Fire detection in kitchens

MARULENG LOCAL MUNICIPALITY

Security+ Guide to Network Security Fundamentals, Fourth Edition. Chapter 13 Business Continuity

How can we prevent security breaches?

Daycare Center Fires

(EMR) system in resource-constrained settings. The use of the EMR at point-of-care (POC)

BNA FEDERAL CREDIT UNION DISASTER RECOVERY PLAN

Advanced Fire Protection in Data Centres

DATA CENTRES UNDERSTANDING THE ISSUES TECHNICAL ARTICLE

Fire protection in archives and storage vaults

REVIEWED ICT DATA CENTRE PHYSICAL ACCESS AND ENVIROMENTAL CONTROL POLICY

EXHIBIT A SCOPE OF WORK

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

SPECIAL APPLICATIONS

The Introduction of ORICO 3549RUS3

PLAN REVIEW GUIDE FOR FIRE ALARM

Restaurant & café guide

FIRE SAFETY FOR OFFICE WORKERS

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

For Data Center and Control Room Applications

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

SMOKE TESTING FOR ASD SYSTEMS AND HARD-TO-ACCESS POINT DETECTORS IN RAIL APPLICATIONS. scorpion

Greater Manchester Fire and Rescue Service

Data Center Security 100% UPTIME PUZZLE. Page 1

Voice alarm system E100 the new standard for safe evacuation

melbourne//australia data center specifications internet + intellectual property + intelligence tel: fax:

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

What ensures optimal protection for my archive and library?

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

Using CFD for optimal thermal management and cooling design in data centers

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

Fire Alarm Control Panel. Family. Operating Manual

HEALTH AND SAFETY REDUCING ACCIDENTS IN KITCHENS

Gambling with your fire security?

singapore//singapore data center specifications tel: fax: internet + intellectual property + intelligence

Answers for infrastructure. Sinteso control panels clear concept, efficient operation

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

DATA CENTRE DATA CENTRE MAY 2015

Installation Instructions for Alarm Module Kit A043F059

Common Power Problems & Power Protection Solutions

WHEN UPTIME IS REALLY CRITICAL DISCOVER THE DIFFERENCE AT ENERGYST.COM

Server Monitoring & Management Services

North Carolina State University Emergency Facilities Closure Checklist- Part I

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

MODELING THE PERFORMANCE OF FIRE PROTECTION SYSTEMS IN MODERN DATA CENTERS

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

Data Center Presentation

Data Centre Services. JT Rue Des Pres Data Centre Facility Product Description

Regulation IO-6.0: Electrical Safety Regulations

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Firefighter Review. Instructor Guide

Maintaining Fire Protection Systems

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Ultrasonic Gas Leak Detection

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Mastering Disaster A DATA CENTER CHECKLIST

Polygon & Property Damage Restoration

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

DPS HOSTED SOLUTIONS

Options and monitoring

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak

How To Use A Sata Dsa Hard Disk Storage System

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

FIRE PROTECTION. FOR COMPUTER ROOMS By Mark L. Robin CLEAN AGENT. FS-World.com. 8 ire & Safety Magazine

Life cycle services for protection and control relays Full support from start to finish

Mineral Insulated Cable A cable for today and tomorrow!

Transcription:

Data Centre alwas protected always up and running. Stefano Valdrighi - Siemens

Business continuity is the critical asset to protect 609,500 Average cost per downtime 7,908 Average cost per minute The total cost of a downtime is not limited to revenue losses as it can ultimately include: Productivity Losses Customer disruption Reputation damage Isolation and repair costs Loss of data Lawsuits Source: Ponemon Institute 2014

Examples of application areas in data centers and fire impact Server and data rooms Control room 18% of fires Protect your data and infrastructure for smooth business operation 1% of fires Protect the «big brother» to ensure continued operation even in emergencies Electrical switching room Emergency power supply 22% of fires Protect your main power supply and keep power efficient 59% of fires Protect your backup generators in the event of an outge and prevent fire spread

Business continuity is under constant threat About 6% of infrastructure failures in data centers are related to fire but do you know why?

There are 4 major reasons why there is a high risk of fire in a data center Heavy power load Electrical fire risk Infrastructure Ventilation Heavy power loads or a defective piece of equipment can very quickly lead to a short circuit or overheating Constant ignition source electricity and combustible materials such as plastics in printed circuit boards Extensive cabling, particularly below raised floors Comprehensive air-cooling resulting in a higher air exchange, increases risk of spreading the fire 1 2 3 4

Fire protection in data centers involves one major challenge high power consumption that requires air cooling, resulting in a higher air exchange. And smoke dilution and redirection because of high ventilation can mean that smoke cannot reach the detectors fast enough. inappropriate fire safety solutions. Many regulations only require sprinkler systems to be installed but water causes damages, and sprinklers react too late in case of a fire. Therefore, early and fast detection and extinguishing is essential in data centers. a high noise level during the extinguishing process. Data centers contain sensible and delicate technical equipment. Latest technological findings show that the high noise level of the discharge can disturb Hard Disk Drives (HDD's) in operation. how to minimize potential disruption, downtime or closure. The no. 1 cause for fire safety system failure is the interface between detection, alarming, control and extinguishing

Sometimes, complying with regulations does not mean protecting business assets NFPA 75 says that if a building has already a water sprinkler system installed, the data center shall have one too* Siemens says that a dry extinguishing system is much better suited because it protects the electronic equipment

Real example: Google, Seattle, USA Damages of fire in April 2010 Fire in Google data center affected over 42,000 servers Following the fire, Google mistakenly returned errors all over the world for one hour The bulk of the damage was not caused by the fire itself, but by the water from the sprinklers used In 2013, a 5 minute downtime costed Google approximately 0.8 mil. USD

No that loud please, we are Hard Disk Drives Sound impacts Hard Disk Drives above 100dB in conjunction with frequency range between 500Hz and 12.5kHz Hard drives sensitivity in the acoustic spectrum: [db*] 130 120 Insensitive for noise at frequencies below 500Hz 110 Certain sensitivity in the frequency range from 500Hz up to 1.6kHz 100 90 Most critical is the range from 1.6kHz up to 8kHz 80 0.200 0.250 0.315 0.400 0.500 0.630 0.800 1.000 1.250 1.600 2.000 2.500 3.150 4.000 5.000 6.300 8.000 10.0 12.5 16.0 20.0 f [khz] Certain sensitivity in the frequency range from 8kHz up to 12.5kHz Severe performance degradation and faults Performance degradation Undisturbed operation Insensitive for noise at frequencies above 12.5kHz BT CPS S&C VM Restricted Siemens AG 2014 All rights reserved.

100dB - a noise level that was proven being safe for Hard Disk Drives (HDDs) 90 100 110 120 130 140 150 [db(z)] >140dB: Damage and unpredictable things likely to happen >130dB: No more data delivered by most HDD s Some HDD s might disconnect and need reboot Permanent signs after noise exposure likely (sector re-allocations) >120dB: Significant disturbance of most HDD s likely More sensitive HDD s already stop delivering data Some HDD s with permanent signs after noise exposure (sector re-allocations) >110dB: Many HDD s show signs of temporary performance degradation Sensitive HDD s already show significant performance degradation >95dB: Sensitive HDD s are starting to show performance degradation <95dB: The vast majority of HDD s are working undisturbed at this noise level Comparative Sound Levels Siemens noise sensitivity scale. Noise sensitivity of HDD s is likely to depend on technological evolution BT CPS S&C VM Restricted Siemens AG 2014 All rights reserved.

Siemens Silent Extinguishing Technology for Hard Disk Drives (HDDs) Many tests with different configurations proved that inert gas extinguishing systems with <110 db at the location of the cabinet is safe for the HDD. Tests were performed in a reference room which shows realistic and comparable characteristics to a data center. Unregulated, Std Nozzle CDT, Std Nozzle CDT, Std Silent Nozzle

Silent nozzle Animation

There are 4 major challenges in data centers when it comes to fire protection 1. Fire detection 2. Extinguishing #1 3. Extinguishing #2 4. Communication High power load needs efficient air-cooling This makes it difficult to detect a fire Many regulations focus on building protection and recommend sprinklers Water causes damage to electronics Sprinklers react too slow HDDs are sensitive to the high noise levels during the discharge of dry extinguishing systems No. 1 cause for fire safety system failure is the interface between detection, alarming, control and extinguishing

Solutions from Siemens to meet the 4 challenges Sinorix Compact XC10 Manual call point FDM225 1. Fire detection 2. Extinguishing #1 3. Extinguishing #2 4. Communication ASD detectors from Siemens Point detectors with ASAtechnology Highest detection sensitivity Natural or chemical extinguishing agents Ideal for electronics Non-corrosive, nonconductive, leave no residues Safe for people and the environment Sinorix Silent Nozzle with unique linear design Keeps noise down during extinguishing All devices on one loop No information will get lost, even if loop is interrupted at one end

Put your data is safe hands and keep Mission-critical facilities at maximum uptime With Innovative products, application know-how and integral Fire Safety concept

Thank you for your attention! Stefano Valdrighi Global Head of Extinguishing Sales and Business Development Siemens Building Technologies, International Headquarters, Zug Gubelstrasse 22 6300 Zug Phone: +41 41 724 4157 Mobile: +41 70 930 10 69 E-mail: stefano.valdrighi@siemens.com siemens.com/buildingtechnologies