Dolphin 3D Imaging 11.8



Similar documents
3D Viewer. user's manual _2

DENTAL Cone beam 3D X-RAY SYSTEM with

Digital Image Processing with DragonflyPACS

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

Digital Imaging & Communications in Dentistry: DICOM and Interoperability


Fast mobile reading on the go November syngo.via WebViewer. Unrestricted Siemens AG 2013 All rights reserved.

Twelve. Figure 12.1: 3D Curved MPR Viewer Window

ENGLISH. Planmeca ProMax 3D Mid

Cone Beam Imaging Why all the Fuss about the X-ray Dose? D.A. Miles BA, DDS, MS, FRCD(C) Dip. ABOM, Dip. ABOMR. Introduction

ENGLISH. Planmeca ProMax 3D concept

CS D Panoramic Cephalometric. Innovation, in reach

multimodality image processing workstation Visualizing your SPECT-CT-PET-MRI images

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

anatomage table Interactive anatomy study table

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

resource Osirix as a Introduction

Paul Guggenheim. President

DBSWIN the digital image centre for the surgery

Temporomandibular Joint Imaging Using CBCT: Technology Now Captures Reality!

5G - R EN ENGLISH. QR srl - Via Silvestrini, Verona Italy Tel info@newtom.it

Veraviewepocs 3D R100 & F40

3D Analysis Software Ez3D

Product Characteristics Page 2. Management & Administration Page 2. Real-Time Detections & Alerts Page 4. Video Search Page 6

TxSTUDIO5.4 Reference Manual

For a new dimension of a practice s success: The 3D unit family.

How To Use Nobelbiocare'S Integrated Treatment Workflow

Veraviewepocs 3D R100 & F40

The professional for your diagnostics.

CLINICAL. Intraoral scanning

European Academy of DentoMaxilloFacial Radiology

Video, film, and animation are all moving images that are recorded onto videotape,

Quick Start Tutorial Imperial version

How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On

Alphacam Art combines Vectric s Aspire artistic design software with the market leading Alphacam manufacturing software.

s y s t e m r e q u i r e m e n t s

The wait is over CS D. 3D imaging is now available for everyone

Rethinking Risk and Benefit in Dental and Maxillofacial Imaging Dose matters

ENG4BF3 Medical Image Processing. Image Visualization

Installation Guide v1.11 and Higher

8000C Digital Panoramic and Cephalometric System. User s Guide

VERSATILE AND EASY-TO-USE 3D LASER SCANNERS > >

3Shape X1 4-in-1 CBCT Scanning Solution

Voxar 3D TM. A suite of advanced visualization and analysis software tools

Cone Beam Implant Planning Manual

Adding Animation With Cinema 4D XL

Changing The World One Hospital At a Time

Anime Studio Debut 10 Create Your Own Cartoons & Animations!

SketchUp Instructions

ProOne Digital X-ray Imaging Hardware Diagrams and System Requirements

Intelligent Monitoring Software

Questions and Answers

VERSATILE AND EASY-TO-USE 3D LASER SCANNERS > >

Quick Start Tutorial Metric version

INTRODUCTION TO RENDERING TECHNIQUES

Trimble Realworks Software

What is Cone-Beam CT and How Does it Work?

Image-based simulation of the human thorax for cardio-pulmonary applications

DryView CHROMA Imaging System

MODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT

If you are working with the H4D-60 or multi-shot cameras we recommend 8GB of RAM on a 64 bit Windows and 1GB of video RAM.

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

technical notes trimble realworks software

ViewPoint 6. Clarify your View

SOFTWARE FOR 3D IMAGE VISUALISATION, ANALYSIS AND MODEL GENERATION

Perfect PDF 8 Premium

Avizo Inspect New software for industrial inspection and materials R&D

How To Use Trackeye

Table of Contents. Chapter 5 Backed-up Video Playback & Exportation Playing back Backed-up Video Exporting Backed-up Video...

VOL. XX, NO. X. Dr. Leo Malin Erases Challenges of Implant Dentistry

Creo Simulate 1.0 April 2011

Introducing your Intelligent Monitoring Software. Designed for security.

TRIOS Digital Impression Solution

3/12/2014. Disclosures. Understanding IAC CT Accreditation. Outline. Learning Objectives. Who is the IAC?

Technical What s New. Autodesk Alias Product Line

IDIS Solution Suite. Backup Service. Software Manual. Powered by

IDIS Solution Suite. Backup Service. Software Manual. Powered by

Visualization Plugin for ParaView

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Kankakee Community College

Creating Your Own 3D Models

Oftentimes, as implant surgeons, we are

Ortelia Space Builder User Manual

Volume visualization I Elvins

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

Advanced visualization with VisNow platform Case study #2 3D scalar data visualization

TruVision Navigator v6

of MME Consulting, Inc.

Construction of human knee bone joint model using FDM based 3D Printer from CT scan images.

Observer RPM. Remote Program Monitor. Post STB-Monitoring, Logging and Troubleshooting

An introduction to 3D draughting & solid modelling using AutoCAD

Overview of the Adobe Flash Professional CS6 workspace

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

Digital panoramic X-ray for practical diagnostics

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.

AHUDesigner. The Air Handling Units selection software. Product description

Web site:

Transcription:

Dolphin 3D Imaging 11.8 The Dolphin 3D software module is a powerful tool that makes processing 3D data extremely simple, enabling dental specialists from a wide variety of disciplines to diagnose, plan treatment, document and present cases. Dolphin 3D allows visualization and analysis of craniofacial anatomy from data produced by cone beam computed tomography (CBCT), MRI, medical CT and 3D facial camera systems. Dolphin Imaging software is an FDA-cleared Class II medical device. 2015 Patterson Dental Supply, Inc. All rights reserved.

Dolphin Imaging 11.8 product features olphin 3D software is already widely used by research/teaching institutes and private practices worldwide. It features tools for onscreen manipulation and analysis of volumetric datasets: Images are easily oriented and rotated, and tissue density thresholds can be adjusted for detailed views of craniofacial anatomy. Measurements and digitization can be performed in both 3D and traditional 2D. Features Import from a variety of 3D dataset formats High-quality, fast 3D rendering Three-dimensional airway analysis Cross sections in Multiple Planar View (MPV) Precise volume orientation Volume stitching: combine two separate volumes into one 2D facial photo wrap onto volume Volume-to-volume superimposition 3D nerve marking TMJ analysis Generate cephalometric and panoramic radiographs 3D-2D measurements: distance, angle and area Create animated movies with automated scripts Design image layouts and reports Images export to other applications Images easily saved into Dolphin patient database Fully embedded in Dolphin Imaging s SQL database 3D implant treatment planning and simulation Distinguish biological structures via their radiolucency with a Hounsfield Unit measuring tool Render any desired combination of CBCT volume, 2D-wrapped or 3D photo, airway and other surfaces, and digital teeth Digital Study Model software supports all.stl and.obj file formats plus seamless integration with CEREC Ortho Software Simple Graphical User Interface (GUI) Dolphin 3D includes powerful yet intuitive tools for you to process multidimensional datasets. There are no complicated commands or scripting languages to learn. Processing and analyzing three-dimensional data has never been easier. Digial Study Model 3D Digital Study Model software works with all intraoral and study model scanners that export to.stl and.obj file format, and also seamlessly integrates with CEREC Omnicam and CEREC Ortho Software from Sirona. Once your study model data is imported, you can: Set occlusion and orientation Display the models in various surface and volume views Take various 3D measurements Run traditional 2D arch-length-discrepancy analyses Available as a standalone module Whether you scan your models or take digital impressions, you can use the new 3D Study Models software module to store these records within the patient s chart. A patient CBCT is not required to store 3D model data.

Merge CBCT volume with surface data from 3D facial camera Translucent soft- and hard-tissue images of pre- and post-surgery case Translucent soft tissue view Translucent hard tissue view View impacted teeth from any angle Easy Data Segmentation and Visualization You prepare the 3D object by grouping intensity levels in pre-set ranges for soft tissue and hard tissue. After this simple procedure, you can easily review the object s solid or translucent skeletal surface; solid, translucent, or photo of soft tissue surface; or both simultaneously. Views can be combined, such as translucent skeletal structures with translucent soft tissue 3D photo facial texture map. Dolphin gives you the power to freely visualize the volume in 3D. In addition to switching from hard tissue and soft tissue views, you can also adjust the factor of translucency and intensity to reveal the structure you desire. Color tools help to further clarify anatomy and their spacial relationships. Clipping tools allow you to quickly visualize hidden structures, or simply eliminate portions of the contents that are not relevant. Isolate desired region of interest Enhanced Object Orientation Establishing a default orientation is crucial to maximize the consistency of analysis of a 3D volume. Dolphin 3D provides tools for defining the midsagittal, axial and coronal planes. You can orient the volume based on an angle, such as the Frankfort plane. You can also adjust the object s default yaw, pitch and roll. These operations can be performed on the CT soft tissue surface, CT hard tissue surface or 3D photo surface. After a scan has been oriented, take advantage of the pre-set views: front, back, right, left, top, bottom, oblique and isometric views. Orientation setup screen Multiple Planar Views and Layouts Choose a layout that is best suited to your task: 3D volume (just the 3D volume view) Volume+3 planes (3D volume and 3 cross section planes on the side) 4-views (3D volume and the cross section planes in equal sized windows) Individual orthogonal projected slices: sagittal, coronal and axial planes 4-volume layout (displays four views of the same volume) You can also adjust Window Level (traverse through 12-bit, 14-bit or 16-bit levels of intensity), zoom, pan, rotate, etc. 4-views (3D volume and the cross section planes in equal sized windows)

Frontal x-ray generated by Dolphin 3D Collimate to the exact areas you require SMV x-ray generated by Dolphin 3D Generated ceph brought into Dolphin s 2D Ceph Tracing module Lateral x-ray generated by Dolphin 3D Panoramic x-ray image created by Dolphin 3D from CBCT image Instant Ceph/Pan Create two-dimensional radiographic images from 3D volume dataset in the lateral, panoramic (OPG), frontal and SMV views. Reconstruct radiographs in: 1:1 projection (no distortion, no magnification) Simple orthogonal/magnification projection (input % of magnification desired) Complex traditional x-ray perspective projection (input detailed x-ray machine geometry; most accurately simulates traditional x-ray) 3D Implant Planning Easily add implants to a patient s 3D image for more precise treatment planning and presentation. Place, move, and rotate implants on the volume, slice or panoramic views. Select implant types from a generic implant template library and specify the size. Zoom in and out on an implant; define a safety zone around each; segment and sculpt the volume to clip around the implant; measure distances and angles; locate nerve canals; export the final simulation as an iso-surface. Comprehensive library of implants from the industry manufacturers. Prosthetic teeth Image filters help emphasize different structures of interest; including: MIP (maximum intensity projection), Ray-sum (academic standard) and a collection of Dolphin proprietary filters. Radiographic images can be saved in the Dolphin Imaging database for report generation and two-dimensional cephalometric tracing (Dolphin Ceph Tracing software required for 2D tracing). Digitizing/Measuring Dolphin 3D makes harvesting data from 3D volume simple, and is an excellent tool for research and data collection. You can measure distances and angles in 3D; design your own analysis in 3D or in 2D (Dolphin Ceph Tracing software required for 2D analysis). Analyze the airway by drawing a border around your selected portion of the volumetric scan; the program will automatically fill in and display all the airway space within that border, then report back telling you the volume of airway space in cubic millimeters. It will also locate, display and measure, in square millimeters, the most constricted spot of that airway. Landmarks can be used in a 3D analysis or translated into identified 2D lateral or frontal cephalometric analyses, such as Roth-Jarabak, McNamara, etc. Further, the 2D points can include x-ray magnification to be compatible with existing norm values. Digitized landmarks can be saved in Dolphin Imaging and exported to a Microsoft Excel spreadsheet or other numerical analysis programs. Pre surgery Post surgery Slice display of airway volume and most constricted area Points can be digitized on the volume or on any of the slice views

Easily locate and mark nerve 3D Nerve Marking Patent-pending interactive tool to locate and isolate the nerve canal on a panoramic projection Clearly draw the visible nerve canals with your choice of width and color View/edit corresponding nerve positions on cross sections View the marked nerve canal within 3D rendering of the skull volume View marked nerve under 3D Select TMJ slicing position and parameters Isolate desired TMJ area TMJ View Choose an area of interest; set center point and axis direction, designed specifically for analyzing the temporomandibular joint Choose desired slice thickness, width, number and direction (coronal, sagittal, or patent-pending circular) View key cross sections of the chosen axes Overview resulting TMJ View group of TMJ slices Hounsfield Unit Color Mapping New in Dolphin 3D is the Hounsfield Unit Color Mapping tool, which helps you distinguish between different biological structures according to their radiolucency measurements. A graph displays the colors as they fall on the Hounsfield Scale as a reference, while the image on the screen is colored in accordingly. Hounsfield Unit colorization Cross Section View Choose a path Choose desired slice thickness, width, number, and direction (linear or patent-pending circular) View key cross sections along the chosen path Examine groups of slices Isolate desired cross section area Select cross section position and parameters View groups of cross section slices Frontal cross section view Overview of resulting cross section

Perform progress superimpositions in 3D Dual Volume Superimposition Superimpose volume scans from different time points to visually track and accurately measure treatment changes in bones and in airways. 2D Facial Photo Wrap Easily create a texture map on the facial surface of any CBCT, CT or MRI scan. Simply import the 2D frontal photo, and Dolphin 3D guides you through a quick and simple stepby-step process to add the photo to the 3D volume. No additional devices or add-ons are needed to create this wonderful visual identity for any patient s 3D volume. 2D Facial Photo Wrap Movie Scripts Automatically create animated movies by collecting key frames from your 3D volume or slice views. By altering the volume s position, zoom factor, translucency, segmentation, clipping and timing attributes, create a movie script which may be reused for volumes of other patients. Dolphin 3D then creates a smooth animated movie from your script. Spin, fly-by and seethrough your volumetric object. Distribute movie files, add them to your Microsoft PowerPoint presentation, or play them on your ipod or other portable media player. You control the movie s speed, resolution, quality and file size with selectable video settings. You can also export the script s key frames as individual images. Create a composite set of image layouts of your 3D volume for later viewing or for transfer to referring clinicians. Cross Sections Map Cross Sections Projection Guide Generate movies Reports Create diagnostic reports from your volumetric dataset. You build a workup report specific to a patient s indication and the specialty of the referral. Build your own library of templates for implant sites, TMJ, impaction studies, tissue pathology, sinus and airway evaluation, and more; a library of existing templates is provided. The template is easily populated on the fly with desired images and cross sections from the volume. Reports can be exported to a document file or hardcopy printout. System requirements: Windows Vista, 7, 8, 8.1, 2003 Server, 2008 Server, or 2012 Server. Standalone or server installs require Windows 7 SP1, Server 2008 R2 or above. For all operating systems, Dolphin supports both 32- and 64-bit versions, and supports Business, Pro, Enterprise, and Ultimate editions. Dolphin recommends Windows 7, 8, or 8.1. The Dolphin 3D system requires 4GB of RAM, and works best with 8GB. The fastest and highest quality rendering modes of Dolphin 3D require a 512 MB or more video card, based on one of these DirectX graphics engines or better: NVIDIA 87400 GS, ATI HD 5450 or Intel HD4600. See www.dolphinimaging.com for additional requirements. NOTE: Dolphin 3D is not supported under terminal services. Verified compatibility list (as of June 2015): CT (DICOM 3 multi-file or single file) Alphabetically listed Acteon Group - WhiteFox scanner Asahi/Belmont Alphard series Carestream Health Kodak 9000 GE 3D medical devices Gendex Dental GX CB-500 Hitachi MercuRay Imaging Sciences International (ISI) i-cat Instrumentarium/PaloDEx Group/ SOREDEX dental imaging lines IMTEC Imaging ILUMA J. Morita 3D Accuitomo 80 and Veraviewepocs 3D MyRay SkyView NewTom 3G, VG and 9000 Planmeca ProMax 3D, ProMax 3D Max PreXion 3D Sirona GALILEOS Comfort, GALILEOS Comfort Plus Vatech Technology Picasso Trio series Any other system that is capable of generating a DICOM compliant data set. 3D Facial Camera (Wavefront.OBJ format) 3d-Shape 3dMD Canfield Scientific Vectra 3D Di3D All trademarks are the property of their respective owners. Cross Sections Slice Dolphin Imaging software is designed for use by specialized dental practices for capturing, storing and presenting patient images and assisting in treatment planning and case diagnosis. Results produced by the software s diagnostic and treatment planning tools are dependent on the interpretation of trained and licensed practitioners. 2015 Patterson Dental Supply, Inc. All rights reserved. 800.548.7241 +1.818.435.1368 info@dolphinimaging.com www.dolphinimaging.com (06/15)