HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons



Similar documents
Bring the fresh in. Dedicated Outside Air Systems

DOAS UNITS. MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR. Kitchens Hotel Corridors Laboratories. Paint Booths. Capacities Tons MBH

Mechanical Rooftop Custom Capabilities

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

PMI-IF-H High Efficiency Gas Heat Units

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

HVAC Basic Science - System Capacity

RPV - RP - RA air handling units


Air Side Economizers and Energy Recovery - Improvements and New Regulations. Richard Lord

Local Dealer:

Element D Services Heating, Ventilating, and Air Conditioning

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION HEAT PUMPS

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

CE6500 Energy Recovery Ventilator

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

Innovent LASER Packaged Fresh Air Conditioning Units

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Cooling Capacity CFM in. w.c. (125 Pa)

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

How To Buy A Lennox Power System

SECTION MORTUARY REFRIGERATORS

Johnson Air-Rotation Systems

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

ENHANCED LABORATORY HVAC SYSTEM

Cooling Capacity CFM in. w.c. (125 Pa)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

HVAC Checklist - Long Form

TECHNICAL MANUAL GDS8 & GHS8

Answers to Your Questions from the Webinar

Glossary of Heating, Ventilation and Air Conditioning Terms

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

F9MXE. Product Specifications

Installation Manual CLIFC Fan & Coil Variable Speed

Cased/Uncased Coils For Gas And Oil Furnaces

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Defining Quality. Building Comfort. Precision. Air Conditioning

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

Nordic Heat Pump Product Guide

How To Improve Energy Efficiency Through Raising Inlet Temperatures

MAC-120HE-01 Air-Cooled Chiller

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

APC APPLICATION NOTE #112

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER

Defining Quality. Building Comfort. Heating and Cooling Coils

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

1.2 Refrigerant Equipment. General

HVAC Infrastructure Retrofit Solutions

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

MULTIZONE APPLICATION OF SOLUTION UNITS

Cooling Capacity CFM in. w.c. (125 Pa)

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

HVAC Systems: Overview

Commercial Portable Air Conditioners

Dehumidification Frequently Asked Questions

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Illuminating Info: UV-C For HVAC

Pool Dehumidification Basics

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

How To Design A Building In New Delhi

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

SECTION AIR CONDITIONING UNIT

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

catalog Single Package Vertical Air Conditioners and Heat Pumps

TWE+TTA TWE+TWA T.R.

Great Lakes Data Room Case Study

LG Electronics AE Company, Commercial Air Conditioning

for K-12 School Buildings

AND SIMPLE HVAC SYSTEMS

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC)

Single Package Vertical Air Conditioners. Vert-I-Pak

G9MXE. Product Specifications

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

ARMSTRONG AIR HEAT PUMPS

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

UDSA - UDSBD unit heater

ECOCIAT. Domestic hot water heat recovery unit

Energy Efficiency in Industrial HVAC Systems

Creating Efficient HVAC Systems

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

FOXAIR 60/50 ALL MODELS

Transcription:

Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM

Comfort Comfort is determined by many factors. Air flow Temperature Activity Internal load External load Desired conditions Comfort also comes at an operational cost. There is a solution...reznor HVAC equipment. Unit Selection The online performance calculator lets you tailor the unit to your needs. This moves your design away from canned equipment to custom specified for your job. The future in web enabled software used by Reznor Agents gives you these custom selections

Best in Class Platform 125 Designed for what you need. Performance Economy Reliability 90% Condensing Gas Heat High Efficiency DX System High Efficiency Supply Fan Factory Installed VFD Integrated Energy Recovery Revit Models Design teams are increasingly utilizing 3D tools to better layout building systems. Reznor brand products support this effort with REVIT drawings. The models have been specifically implemented to make the design professional work easier, faster and more accurate.

The Reznor Model YDSA Heating When it comes to heating efficiency and reliability, Reznor leads the world. The Platform 125 products carry the fourth generation of condensing 90+% heat sections and fifth generation of standard efficiency 80+% heat sections. And don t forget, for many climates, heating (versus cooling) is where the savings potential really exists. Features: 5:1 or 10:1 gas modulation 2 or 4 stage gas & electric control 92% & 80% gas heating efficiency Constant gas heating thermal efficiency 409 stainless steel heat exchangers SCR electric heat modulation ANSI Z83.3 certified Condensate neutralizer Cooling High efficiency DX system - up to 13.3 IEER. This efficiency simply translates into lower operational costs. Features: Energy efficient compressors 10%-100% capacity control ECM condenser fans Low ambient operation Corrosion-proof, double sloped drain pan Sound blankets Coil coating - 6,048 hours salt spray effectiveness Ozone friendly R410A Froststat, high and low pressure switches Comparison of Systems 95% Reznor Deep Modulation Condensing Equipment Gas Modulation Efficiency 90% Total cost of ownership is the truest measure of value for your HVAC investment. The ability to modulate input allows greater control over constantly changing load conditions. Most heating systems lose over 6.25% of their thermal efficiency when modulating. Reznor models start with high efficiency and maintain that efficiency throughout the modulation range to maximize your HVAC investment dollars. 75% 100% 75% 50% 25% 0% Firing Rate Efficiency 85% 80% Conventional HVAC Equipment Reznor Standard Modulation Equipment

Features & Benefits Supply Fan The supply fan is the heart of the system and the one component in a package unit that impacts all other mechanical functions. Platform 125 units exhibit state of the art fan technology and system design. Features: Direct drive plenum fan Slide-out servicing & inspection ABB VFD control (standard) Duct pressure control Building pressure control Adjustable constant volume Phase loss protection Direct CFM measurement High & low filtration hoods 11 intake damper configurations MERV 8 & 13 filters Reheat Independent DX circuit 15-17 F temperature rise Modulated capacity COP> 20 Low ambient operation Construction It all has to come together. The units are designed to withstand the rigors of weather conditions around the world and operate at the highest efficiency with the least amount of cabinet thermal loss. Features Foam panel double wall construction R13 insulation value Renewable/organic insulation material Safe bottom lifting Pre-painted G90 galvanized steel to meet ASTM B-117 for 1,000 hours salt spray Hinged doors Lockable doors Easy access to components Energy Recovery Energy recovery systems recover exhaust air energy and re-introduce it into the conditioned space. Model YDSA, with the total enthalpy energy recovery module, integrates this savings allowing greater application flexibility. Features: Integrated power, controls, and mechanical ARI rated internal enthalpy wheel Minimal cross contamination (less than 5%) Slide out servicing Optional low ambient control kit for temperatures below 10 F Electric preheat Standard barometric relief exhaust damper More Capacity Combinations The YDSA allows for more combinations of heating and cooling than traditional units. This gives the building designer more application flexibility, allowing a better match of heat/cool capacities to various building loads. Gas Heat Input (MBH) DX Capacity Size (Tons) 80% 92% 10 12.5 15 17.5 100 -- 125 -- 150 -- -- 150 175 -- 200 225 300 300 -- 375 400 -- 450 500 -- 600 --

Operation Saving How does the unit provide operational savings compared to standard package units? HEATING COSTS Heating Condensing Gas Heat (92%) = 10% to 18% reduction in associated fuel costs. Cooling High Efficiency DX (13.3 IEER) = 19% reduction in associated electrical costs. COOLING COSTS Supply Fan VFD Lower than ASHRAE Standard 90.1 fan horse power usage targets = 10% to 15% reduction in associated electrical costs (at full load). Integrated Energy Recovery Extends the range of free cooling and free heating by completely eliminating the need for mechanical heating and cooling during mild days. On peak load days the energy recovery can reduce mechanical capacity usage by up to 30% ENERGY EFFICIENCY Continuous Conditioning Technology The unit shall operate to maintain space temperature control through use of thermostat. When there is a call for cooling, the unit will operate to maintain user adjustable 52 to 55 F discharge air temperature. When there is a call for space heating the unit will maintain an adjustable sliding discharge air temperature from 90 to 110 F based upon outdoor conditions. When the thermostat does not require cooling or heating the supply fan will drop to a user define low setting; otherwise the supply fan operates to maintain design CFM values. Option CL23

Why High Efficiency Heating? There are typically more heating hours than cooling hours. High efficiency heating will provide the greatest energy saving potential - much more than cooling. The Reznor Platform125 series provides bestin-class high efficiency heating AND high efficiency cooling for commercial buildings IEER - 13.3 92% Gas Heating Efficiency Regional Percentage Heating vs. Cooling Energy Usage U.S. and Canada Space Heating Space Cooling New England Middle Atlantic Midwest (E) Midwest (W) South Atlantic So. Central (E) So. Central (W) Mountain Pacific Canada 50% Average of all building types. Sources: U.S. Dept. of Energy CBECS Studies & NRCAN Energy Data Handbook 2010 Real Savings Building Owners and Managers Association (BOMA) reports the typical office building has utilities costs of $2.32 per square foot (ft 2 ) for a typical 14,000 ft 2 property. For new LEED construction, the utility target is set for $1.80 ft 2. This is an operational saving of $7,280 annually. To reach this target, the building must reduce 22% of its power usage. The YDSA reduces heating energy usage up to 18%, and 19% for cooling with Fan & ERV providing an additional economizer (free cooling and heating) range for the building. Standard equipment can t do this. The YDSA is the ideal choice for LEED & Retrofit applications!

Model YDSA -120-150 -180 A -210 A BTU 120,000 150,000 180,000 210,000 Nominal Cooling Capacity Tons 10 12.5 15 17.5 kw 35.2 44.0 52.8 61.5 Nominal Airflow scfm 3500-5000 4375-5500 5250-7500 6125-8750 M 3 /hr 5946-8495 7433-9344 8919-12742 10406-14866 IEER @ AHRI 340/350 13.3 12.4 > 12.5 > 12.5 Compressor Quantity 2 2 2 2 Gas Heat Size B High Efficiency H100-H400 Very High Efficiency G150-G372 Electric Heat Size (kw) 30, 60, 90 30, 60, 90, 120 Power C 208/3, 230/3, 460/3, & 575/3 60Hz 380/3 50Hz Natural Gas or Propane Heating High Efficiency (80%) Very High Efficiency (92%) Option MBH kw Code Input Output Input Output H100 100 80 29 23 H102 D 100 80 29 23 H125 A 125 100 37 29 H150 D 150 120 44 35 H175 175 140 51 41 H200 200 160 59 47 H202 D 200 160 59 47 H300 300 240 88 70 H400 400 320 117 94 H402 D 400 320 117 94 H502 D 500 400 147 117 H602 D 600 480 176 141 G150 150 138 44 40 G225 225 207 66 61 G300 300 276 88 81 G302 D 300 276 88 81 G372 D 370 340 108 99 G452 D 450 414 132 121 A These sizes available in the fourth quarter of 2013. B See gas heating table for sizes, heating input and output values. High efficiency gas heating section is 80%ncv/88%gcv. Very high efficiency heating systems are 92%ncv/105%gcv. (Efficiency in North America are measured in ncv. Efficiency in Europe is measured in gcv.) C Size -060 also available in 230/1/60 power voltage. D Dual heat sections for better modulation control. The complete line of Reznor rooftop units can provide comfort for a wide variety of conditions. Select the one right for your specific application. YDSA - Space Conditioning YDHA - High Outside Air Volume YDMA - Dedicated Outdoor Air For complete catalog information including submittals, energy calculations, dimension drawings, and more go to or call 800-695-1901. Note: In keeping with our policy of continuous product improvement, we reserve the right to alter, at any time, the design, construction, dimensions, weights, etc., of equipment information shown here. 2014 Reznor, LLC. All rights reserved. Printed in U.S.A. Reznor is registered in at least the United States. All other marks are the property of their respective organizations. 0614 OG 2.5K Form MC-YDSA (Version A.2)