ebridge100spr - EoC Receiver ebridge4spt - 4 Port PoE/PoE+ EoC Transceiver Switch



Similar documents
ebridge1spr - EoC Receiver ebridge4spt - 4 Port PoE/PoE+ EoC Transceiver Switch

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

User Manual. EtherUSB

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Wireless Router Setup Manual

HWg-STE HWg-STE PoE MANUAL

HC Products ILF-100WD User Manual

3.5 EXTERNAL NETWORK HDD. User s Manual

IP Power Stone 4000 User Manual

GV-Data Capture V3 Series User's Manual

JKW-IP. IP Video Entry System. QuikStart Guide

VoIP Zone Controller: 4-Port Audio Out Operations Guide

Broadband Router ESG-103. User s Guide

P Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address Password Version /2007 Edition 1

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

User Manual. EtherUSB

Network Power Distribution Module. Installation and Programming Manual

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

Linksys WAP300N. User Guide

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

TENVIS Technology Co., Ltd. User Manual. For H.264 Cameras. Version 2.0.0

10/ English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point

Networking Essentials

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Hills Professional Series NVRs and Cameras

Dominion KX II-101-V2

Users manual. TCW181B-CM_R1 Page 1

Broadband Phone Gateway BPG510 Technical Users Guide

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

SNMP Web Management. User s Manual For SNMP Web Card/Box

Wifi Pan/Tilt IP Camera User Manual

Quick Installation Guide DAP Wireless N 300 Access Point & Router

Welcome. Unleash Your Phone

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Acano solution. Acano Solution Installation Guide. Acano. January B

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

GV-IP Decoder Box and GV-Pad

N300 WiFi Range Extender

BROADBAND INTERNET ROUTER USER S MANUAL. Version Page 1 of 13 -

H.264 Internet Video Server

Temperature Alert. LAN-based Temperature and Humidity Data Logger

Long Reach PoE over Coaxial Extender Kit

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Gigabit Content Security Router

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Network Video Recorder. Operation Manual

APPLICATION NOTE. CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14. App. Note Code: 3T-Z

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).

Assign a static IP address for your computer. Please refer to the T3 in Troubleshooting guide if you need assistance.

Assign a static IP address for your computer. Please refer to the T3 in Troubleshooting guide if you need assistance.

Gigabit Multi-Homing VPN Security Router

2 Setting Up the Hardware for a Wired Ethernet Network Setting Up the Software for an Ethernet Network... 21

Thank for choosing the Dominion KX III, the industry's highest performance enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch.

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

IntraVUE Plug Scanner/Recorder Installation and Start-Up

Shield Pro. Quick Start Guide

Link Link sys E3000 sys RE1000

Barracuda Link Balancer Administrator s Guide

Contents. Section A Networking Basics Learning the Basics Section B Wired Ethernet Networking... 17

Quick Start Guide. Cisco SPA100 Series Analog Telephone Adapters. SPA112 Two Port Phone Adapter SPA122 ATA with Router

Quick Start Guide NVR DS-7104NI-SL/W NVR. First Choice For Security Professionals

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

Connecting the DG-102S VoIP Gateway to your network

1 Serial RS232 to Ethernet Adapter Installation Guide

Dual-Band Wireless Network Extender. Model #: WCB3000N. User Manual. Ver 1.0

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Meraki MX50 Hardware Installation Guide

Legal Disclaimers. For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code.

Wireless LAN Access Point. IEEE g 54Mbps. User s Manual

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Chapter 2 Preparing Your Network

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Multi-Homing Dual WAN Firewall Router

19 LCD / 8 CHANNEL DVR COMBO WITH 160GB HDD & 4 CAMERAS

E13. 5MP Cube with Basic WDR, Fixed lens Hardware User s Manual. (PoE) Ver. 2012/10/22

Chapter1. Interface Introduction

emerge 50P emerge 5000P

1. Panel Descriptions Connecting the 4 Ports VoIP ADSL Router Setting up the TCP/IP in Windows... 5

Linksys Gateway SPA2100-SU Manual

IDDERO TOUCH PANELS. Video door phone configuration

A Division of Cisco Systems, Inc. GHz g. Wireless-G. User Guide. Access Point with Power Over Ethernet WIRELESS WAP54GP. Model No.

Static Business Class HSI Basic Installation NETGEAR 7550

1. Hardware Installation

NeoGate TA Series Quick Installation Guide

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

Transcription:

PLUS Installation Guide ebridge100spr - EoC Receiver - 4 Port PoE/PoE+ EoC Transceiver Switch I.T.E. 43KC Rev. 072313 Overview: The ebridge4sk kit consists of ebridge100spr and which are Coax to CAT-5 Ethernet adapters/media converters that deliver data and power over coax cable. ebridge4sk enables fast 10/100 Base-T Ethernet digital communication. allows you to upgrade your existing infrastructure by replacing a single analog device with up to four (4) PoE/PoE+ devices. ebridge100spr passes data and sends power over the coax to the. Data transmission and power over the Coax are possible up to 300m. Maximum range from head end to the PoE camera/device is 610m, taking into consideration that up to 100m of structured cable may be deployed at each end. Built-in IP management allows for remote camera reset, monitoring and reporting via various IP protocols. ebridge4sk enables cost-effective system upgrades and eliminates the costs and labor associated with installing new network cabling. Note: Ethernet maximum distance (see Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 3). Agency Listings: UL/CUL Listed for Information Technology Equipment (UL 60950-1). CE approved. Input: ebridge100spr - 51-56VDC/60W max. power.* - powered by ebridge100spr. Power Output: : 4 ports PoE+ (30W) per port. Total output power: 60W. Ethernet: Connectivity: RJ45, auto-crossover. Wire type: 4-pair Cat-5e or better structured cable. Distance: up to 100m. Speed: 10/100BaseT, half/full duplex, auto negotiation. Coax: Distance: up to 300m. Connectivity: BNC, RG-59/U or similar. Throughput is rated to pass 100mbps from camera to receiver. With the proper headend equipment multiple Megapixel cameras can be used. LED Indicators: Blue LED - Coax link connection. *UL Listed Class 2 or limited power source (NetWay1D). Features: LED Indicators (cont d): Green LED - Power (ebridge100spr only). Yellow and Green LED (RJ45) IP Link status, 10/100Base-T/active. Environmental: Operating Ambient Temperature : ebridge100spr: -40ºC to 60ºC (-40ºF to 140ºF). : 60W: -40ºC to 75ºC (-40ºF to 167ºF). Storage Temperature: -40ºC to 75ºC (-40ºF to 167ºF). Humidity: 20 to 85%, non-condensing. Applications: Retrofit digital IP cameras in an analog CCTV installation (up to four (4) IP cameras expansion per analog camera). Works with Megapixel, HD720, HD1080 and VGA (SD) cameras (see note, pg. 2). Extend Network link distance in an industrial environment. Upgrade deployed CCTV Coax to a digital network in Retail, Hospitality, Arenas, Casinos, Airports, Schools, Hospitals, Transportation, etc. Mechanical: Dimensions (H x W x D approx.): ebridge100spr: 4.375 x 3.5 x 1 (111.125mm x 88.89mm x 25.4mm) : 1.7 x 5.23 x 8.93 (43.18mm x 132.84mm x 226.82mm) ebridge4sk - 1 -

Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. ebridge100spr and is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. The ebridge100spr and is intended for indoor use only. 1. ebridge100spr installation: a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit s mounting hole. Unit should be mounted in proximity to Ethernet switch/network, NVR or video server. b. Connect 56VDC UL Listed Class 2 or limited power source to terminals marked [Power --- Input +] (observe proper polarity) (Fig. 1, pg. 3). Use 22AWG-16AWG wire for this connection. Caution: 56VDC will be present on coax. The other end of the coax should only be connected to the. c. Connect structured cable from Ethernet switch/nvr (network video server) to RJ45 jack marked [10/100 BaseT] (Fig. 1, pg. 3). d. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 3). 2. installation: a. Affix rubber pads to for shelf installation (Fig. 9, pg. 12). b. Connect Coax cable from ebridge100spr to BNC connector marked [Coax] located on the back of the unit (Fig. 1, pg. 3). c. Connect structured cable from PoE/PoE+ cameras/devices to RJ45 jacks marked [1-4] (Fig. 1, pg. 3). Note: The ebridge is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment. Parameter Connections Input power requirements Indicators Environmental Conditions Regulatory Compliance Weights (approx.) Technical Specifications: Description BNC for Coax link. RJ45 for Ethernet link. ebridge100spr - 51-56VDC/60W @ max. power. - powered by ebridge100spr. Blue: Coax Link. Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity. Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T. Operating Ambient Temperature (UL60950-1): ebridge100spr: -40ºC to 60ºC (-40ºF to 140ºF). : 60W: -40ºC to 75ºC (-40ºF to 167ºF). Relative humidity: 85%, +/ - 5% Storage Temperature: -40ºC to 75ºC (-40ºF to 167ºF). Operating Altitude: - 1000 to 6,561.679 ft. ( - 304.8 to 2000m). UL/CUL Listed for Information Technology Equipment (UL 60950-1). CE approved. ebridge100spr - Product: 5.1 oz. (0.144 kg.), Shipping: 7.76 oz. (0.22 kg.) - Product: 2.9 lbs. (1.32 kg), Shipping: 3.9 lbs. (1.77 kg) - 2 - ebridge4sk

Fig. 1 ebridge100spr Typical Application: (Front View) 56VDC Input Ethernet Switch Coax up to 300m PoE Output 10/100 Base-T CAT-5e up to 100m CAT-5e up to 100m CAT-5e up to 100m NVR Network Video Server (Head End Equipment) PoE/PoE+ Cameras PoE/PoE+ Cameras Maximum Length of Coax Type vs. Camera Power/PoE Class: RG59/U RG59/U RG59/U RG59/U RG6/U Camera Power/ (23AWG) (22AWG) (20AWG) (18AWG) (18AWG) PoE Class Max. Length (meters) 13W/0 or 13W/3 260.64m 335.28m 500m 500m 500m 25W 118.9m 150.6m 239.3m+ 365.8m+ 365.8m+ 60W 50.3m+ 63.4m+ 100.6m+ 160m+ 160m+ 90W 33.5m 42.1m 67.1m+ 106.4m+ 106.4m+ 120W 25m 31.7m 50.3m+ 80.2m+ 80.2m+ Factory Default settings IP Address: 192.168.168.168 User Name: admin Password: admin Internet Browser Setup 1. Set the static IP address for the laptop to be used for programming to the same network IP address as the, i.e. 192.168.168.200 (the default address of the is 192.168.168.168). 2. Connect one end of the network cable to the network jack on the ebridge100spr and the other to the network connection of the laptop. ebridge4sk - 3 -

3. Open a browser on the computer and enter 192.168.168.168 into the address bar. A dialog box Authentication Required will appear requesting both user name and password enter the default values here. Click on the button labeled Log In. 4. The status page of the will appear. This page displays the real time status and health of each device connected to the. Network Setup: Click on the tab labeled Network Settings. This will open the Network Setting screen. In this screen the MAC Address of the module will be found along with the programming fields for the Network Settings, Trap Receiver Settings, SNMP Port Settings and Email Settings. File Setup Help Network Settings: In the IP Address Method field select the method that the IP Address for the will be obtained Static or DHCP then follow the appropriate steps. Fig. 2 DEVICE NAVIGATION PANEL WEBVIEW INTERFACE STATIC (Fig. 2a, pg. 4): Dashboard Linq 1. IP Address: Enter the IP address assigned to the by Lab the Linq2 A network Management Interface Lab Linq2 B Netway administrator. Netway16M Status Setup Network Settings Security Settings Events Log Netway4ES 2. Subnet Mask: Enter the Subnet of the network. Netway8M Netway1DWPM 3. Gateway: Enter the TCP/IP gateway of the network access point FireSwitch (router) Site ID: RJ Sports Wear FireSwitch Network Settings: Email Settings: being used. ebridge Note: Gateway configuration is required to properly receive emails ebridge200wpm IP Address Method: STATIC a. From: ebridge16pcrx from the device. IP Address: 10.0.0.113 Subject: 4. HTTP Port: Enter the HTTP port number assigned to the Subnet Mask: 255.255.255.0 Username: event.report module by the network administrator to allow remote access and monitoring. Gateway: 10.0.0.1 Password: The default inbound port setting is 80. HTTP is not encrypted and unsecure. HTTP Port: 2713 SMTP Server: smtp.gmail.com Even though HTTP can be used for remote access it is recommended HTTPS Port: 443 SMTP Server Port: 587 primarily for use with LAN connections. MAC Address: BC:34:00:30:00:B3 Outgoing Email 1: mike@jrsport.com 5. HTTPS Port: Enter the HTTPS port number assigned to the Submit Network Settings Outgoing Email 2: steve@jrsport.com module by the network administrator to allow remote access and monitoring. Outgoing Email 3: amy@jrsport.com Trap Receiver Settings: The default inbound port setting is 443. Being encrypted and more secure, Outgoing Email 4: scott@jrsport.com Trap Receiver IP Address 1: 10.0.0.102 HTTPS is highly recommended for remote access. b. Outgoing Email 5: maria@jrsport.com Trap Receiver IP Address 2: 10.0.0.56 6. Click the button labeled Submit Network Settings. A dialog box will display New network settings will take effect after the server is rebooted. Click OK. Trap Receiver IP Address 3: 62.19.75.80 DHCP (Fig. 2a, pg. 4): 1. After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings. A dialog box will display New network settings will take effect after the server is rebooted. Click OK. Next click on the LOG button > ebridge16pcrx [50.74.149.196:2717] added. labeled Reboot Server. After rebooting the will > ebridge200wpm be set [50.74.149.196:2712] in the added. > [50.74.149.196:2713] added. > FireSwitch [ 50.74.149.196:2710 ] added. DHCP mode. The IP address will be assigned by the router > when Netway1DWPM the [ 50.74.149.196:2716 ] added. > NetWay8M [ 50.74.149.196:2715 ] added. > Netway4ES [ 50.74.149.196:2714 ] added. is connected to the network. It is recommended > Netway16M to have [ 50.74.149.196:2707 the] added. > Lab Linq2 B [ 50.74.149.196:2703 ] added. assigned IP Address reserved to ensure continued access (see Ethernet the adapter detected. network Trap receiver Port: 162 administrator). 2. Subnet Mask: When operating in DHCP the router will assign the subnet mask values. 3. Gateway: TCP/IP gateway of the network access point (router) being used will be displayed. Trap Receiver IP Address 4: 45.165.245.146 Trap Receiver IP Address 5: 50.74.175.125 SNMP Port Settings: Submit Trap Receiver IP Settings SNMP Port: 161 Trap Message Port: 162 Submit Port Settings c. event.report@linqinfo.com Restore Factory Settings Reboot Server Network Settings Test Email Restore Default Submit Email Settings v1.99.22 Site ID: RJ Sports Wear d. Site ID - 4 - ebridge4sk

4. HTTP Port: Enter the HTTP port number assigned to the module by the network administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access it is recommended primarily for use with LAN connections. 5. HTTPS Port: Enter the HTTPS port number assigned to the module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access. 6. Click the button labeled Submit Network Settings. A dialog box will display New network settings will take effect after the server is rebooted. Click OK. Trap Receiver Settings (Fig. 2b, pg. 4): 1. Enter up to five SNMP trap receiver IP addresses. When accessing the remotely check with the network administrator for proper configuration. 2. Click the button labeled Submit Trap Receiver IP Settings. A dialog box will display New Trap Receiver IP settings will take effect after the server is rebooted. Click OK. SNMP Port Settings (Fig. 2c, pg. 4): SNMP uses the default port 161 for general SNMP messages and port 162 for SNMP trap messages. In the event these port need to be changed enter the new port numbers assigned by the network administrator. Click the button labeled Submit Port Settings. A dialog box will display New SNMP port settings will take effect after the server is rebooted. Click OK. Email Settings (Fig. 2d, pg. 4): The can send emails via an in-house email server, email service provider (i.e. Gmail, Yahoo) or Altronix default email service. In-house email server: 1. From: Enter the email address assigned to the module by the system administrator. 2. Subject: Identify the location of the ebridge4spt (i.e. the Site ID). 3. Username: Enter the username associated with the module email address. 4. Password: Enter the username password. 5. SMTP server IP: Enter the SMPT IP address of the in-house email server. 6. SMTP server Port: Enter the SMPT port assigned to the in-house email server. 7. Outgoing Email Address 1-5: Enter up to five outgoing email addresses. 8. Click the button labeled Submit Email Settings email setting will be saved. Email service provider: 1. From: Enter the email address for the module. 2. Subject: Identify the location of the (i.e. the Site ID) 3. Username: Enter the username associated with the module email address. 4. Password: Enter the username password 5. SMTP server IP: Enter the SMPT IP address of the email service provider. 6. SMTP server Port: Enter the email SMPT port number. The default SMPT email ports are 25 or 465 unless otherwise specified. 7. Outgoing Email Address 1-5: Enter up to five outgoing email addresses. 8. Click the button labeled Submit Email Settings email setting will be saved. Altronix default email service: 1. All required sender and network fields have already been populated. 2. Outgoing Email Address 1-5: Enter up to five outgoing email addresses. 3. Click the button labeled Submit Email Settings. Email settings will be saved. To test the email setup click the button labeled Test Email. An email will be sent to all Outgoing email addresses. If the test email is not received contact the ebridge4sk - 5 -

network administrator and repeat the email setup sets. After all fields have been programed click the button labeled Reboot Server. A dialog box will display Please allow up to 30 sec. for server to reboot. Click OK. All programmed information will be saved after the server has rebooted. Setup: Click on the tab labeled Setup. The setup page will open. In this screen the Site ID, Date/Time and Port identification are setup, along with the ability to enable and disable individual ports. Site ID (Fig. 3a, pg. 6): Enter a descriptive name that will identify the location of the. The Site ID will appear in both the trap message and email notifications. Date/Time (Fig. 3b, pg. 6): Time and Date can be entered two different ways manually or by syncing the date and time with the host computer. Manual setup (Fig. 3b, pg. 6): Individually select the appropriate information for each of the required field then click Update. This will update time of the to the programmed information. The manual setup can be used when programming devices installed in one time zone and monitored in another. Sync Setup (Fig. 3b, pg. 6): Clicking the button labeled Sync Date/Time with computer will set the to the time of the host computer. Port ID (Fig. 3c, pg. 6): Enter a descriptive name and/or location of the device connected to the port. Port Status (Fig. 3d, pg. 6): Individual ports can be enabled or disabled by clicking the button labeled Enable Port/Disable Port. This feature allows unused ports to be disabled and also can be used to reboot a connected device by cycling power OFF and ON. After all fields have been programmed click on the button labeled Save Settings. Fig. 3 Management Interface Status Setup Network Settings Security Settings Events Log v1.99.22 Setup Site ID: a. RJ Sports Wear Update Site ID Trap Receiver Settings: b. Jul 15 2015 [ 9 : 32 : 53 am ] Update Sync Date/Time with computer Port Port ID c. Port Status d. 1 Main Entrance Enabled Disable Port 2 Production Enabled Disable Port 3 Receiving Enabled Disable Port 4 Shipping Enabled Disable Port Save Settings - 6 - ebridge4sk

Man Security Settings: Status Setup Network Settings Security Settings Click on the tab labeled Security Settings. The security setting page will open. In this screen the SSL certificate and Key will be entered, the SSL can be enabled or disabled and new username and password can be set. Using an SSL certificate will ensure that when remotely accessing the all data has been encrypted and there for secure through the assigned HTPPS Port. Site ID: RJ Sports Wear Fig. 4a SSL Certificate Setting (Fig. 4a, pg. 7): Generating a self-signed SSL Certificate and Key. SSL Certificate Settings: 1. State: Two letter code representing the state where the organization is located. 2. Location: The city where the organization is located. 3. Organization: The legal name of the organization. This should not be abbreviated, and should include suffixes such as Inc., Corp, or LLC. 4. Unit Name: Name of the device. 5. Common Name: Domain name or IP address of the server. This is typically assigned by the network administrator. 6. Email Address: An email address used to contact the organization. After all field have been completed click on the button labeled Submit SSL Settings. A dialog box State: Locality: Organization: Unit Name: Common Name: NY Brooklyn RJ Sports Wear Inc. 192.168.168.168 will appear Please allow up to 30 secs. for server to reboot. Click OK. A self-signed SSL certificate Email Address: mike@rjsports.com will be generated with the information provided in the SSL certificate settings fields. The certificate will be valid for 500 days, and time stamped with the time settings present on themanagement Interface Submit SSL Settings module. The date and time must be synced with the host computer before generating an SSL certificate. Status Setup Using a private SSL certificate and Key (Fig. 4b, pg. 7): Private SSL Certificates and Site Keys ID: RJ must Sports be Wear uploaded using the Altronix Dashboard. For additional information refer to the Altronix Dashboard setup/user manual section Updating firmware / SSL certificate and Key. SSL Certificate Settings: Network Settings SSL Status: State: Certificate Status: Certificate OK = Valid SSL Certificate NY Bad Certificate = Invalid SSL Certificate Locality: Brooklyn No Certificate = a Valid SSL Certificate has not been loaded. Key Status: Key OK = Valid SSL Key Organization: Bad Key = Invalid SSL Key RJ Sports Wear Inc. No Key = a Valid SSL Key has Unit not Name: been loaded. SSL State: The SSL of the can be turned on and off by click the Common Name: 192.168.168.168 button labeled Turn SSL On/Turn SSL Off. Email Address: mike@rjsports.com Security Settings Submit SSL Settings Events Log SSL Status: Change Username and Password: Username: RJsports Password: Confirm Password: SSL State: Off Turn SSL On Security Settings day, Jul 31 2015 [9:10 am] Certificate Status: Certificate Ok ebridge4sk - 7 - Fig. 4b ****** ****** Key Status: Key Ok Save Username and Password v1.99.22 Events L

Locality: Organization: Brooklyn RJ Sports Wear Inc. Change Username and Password (Fig. 4c, pg. 8): Unit Name: 1. Username: Enter the new Username (up to 32 characters) required to access the. 2. Password: Enter the new Password (up to 32 alpha Common numeric Name: characters) 192.168.168.168 required to access the. 3. Confirm Password: Reenter the new Password. Email Address: mike@rjsports.com Click the button labeled Save Username and Password. A dialog box with appear, New settings have been applied. Click OK. Submit SSL Settings After saving, the new username and password will be active. Fig. 4c SSL State: Off Turn SSL On Change Username and Password: Username: RJsports Password: ****** Confirm Password: ****** Management Interface Save Username and Password Event Log and Heartbeat Timer: Click on the tab labeled Event Log. The event log will open. This screen will display the event log along with the heartbeat timer setup. Event Log: The event log will display the 50 most recent events. To update the Event Log click the button labeled Display/Refresh Log. Fig. 5 Status Setup Network Settings Security Settings Events Log v1.99.22 Events Log Site ID: RJ Sports Wear day, Jul. 31 2015 [9:01 am] Display/Refresh Log Heartbeat Timer Settings Last update: Jul 31 2015 09:01:37 GMT-0400 (Eastern Daylight Time) Jul 31 2015 08:05:03 GMT-0400 (Eastern Daylight Time) : @@Port3 Disabled Jul 31 2015 08:10:12 GMT-0400 (Eastern Daylight Time) : @@Port1 Disabled Jul 31 2015 08:15:24 GMT-0400 (Eastern Daylight Time) : @@Port2 Disabled Jul 31 2015 08:20:36 GMT-0400 (Eastern Daylight Time) : @@Port4 Disabled Jul 31 2015 08:35:17 GMT-0400 (Eastern Daylight Time) : @@Port3 Enabled Jul 31 2015 08:40:28 GMT-0400 (Eastern Daylight Time) : @@Port1 Enabled Jul 31 2015 08:45:43 GMT-0400 (Eastern Daylight Time) : @@Port2 Enabled Jul 31 2015 08:50:00 GMT-0400 (Eastern Daylight Time) : @@Port4 Enabled - 8 - ebridge4sk

Heartbeat Timer: The heartbeat timer will send a trap message indicating that the is still connected and communicating. Setting the Heart Beat Timer: 1. Click the button labeled Heartbeat Timer Setting. 2. Select the desired time between heartbeat messaging in the Days, Hours, Minutes and Seconds in corresponding fields. 3. Click the button labeled Submit to save settings. Fig. 6 Management Interface Status Setup Network Settings Security Settings Events Log v1.99.22 Events Log Site ID: RJ Sports Wear Display/Refresh Log Heartbeat Timer Settings day, Jul. 31 2015 [9:01 am] Last update: Jul 31 2015 09:01:37 GMT-0400 (Eastern Daylight Time) Heartbeat Timer Settings: 1 Days 0 Hours 0 Minutes 0 Seconds Submit Updating Firmware: Firmware updates must be done using the Altronix Dashboard. For additional information refer to the Altronix Dashboard setup/user manual s section Updating firmware / SSL certificate and Key. ebridge4sk - 9 -

Status Screen: a. Class Power (Fig. 7a, pg. 10): Wattage required by the PoE class of the device. b. Actual Power Draw (Fig. 7b, pg. 10): Amount of watts being drawn by the connected device. c. Device Status (Fig. 7c, pg. 10): Active or Inactive. d. Port Status (Fig. 7d, pg. 10): Indicates whether port is Enabled or Disabled. Fig. 7 WEBVIEW INTERFACE Management Interface Site ID Status Setup Network Settings Security Settings Events Log v1.99.22 Site ID: RJ Sports Wear Status Wednesday, Jul. 15 2015 [9:35 am] Port 1 : Main Entrance Port 2 : Production Class Power Actual Power Draw Device Status Port Status Class Power Actual Power Draw Device Status Port Status a. b. c. d. 6.49 3.85 Active Enabled 6.49 3.90 Active Enabled Port 3 : Receiving Port 4 : Shipping Class Power Actual Power Draw Device Status Port Status Class Power Actual Power Draw Device Status Port Status 6.49 3.25 Active Enabled 6.49 3.25 Active Enabled Connection Status: OK... t: 162-10 - ebridge4sk

Notes: ebridge4sk - 11 -

Fig. 8 1.7 (43.18mm) Chassis Mechanical Drawing & Dimensions (H x W x D approx.): 1.7 x 5.23 x 8.93 (43.18mm x 132.84mm x 226.82mm) 8.93 (226.82mm) PoE Output 10/100 Base-T 8.42 (213.87mm) 5.23 (132.84mm) Coax SLOC link LED Shelf Installation A 1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 9). 2- Place unit in desired location. B Fig. 9 Mounting Hardware (Included): Four C (4) rubber pads Left side C Rubber Feet Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com. Lifetime Warranty, Made in U.S.A. IIeBridge4SK I25O MEMBER - 12 - ebridge4sk