SIMATIC PDM software. Siemens FI 01 2001 7/1



Similar documents
SIMATIC The Process Device Manager Manual Edition 12/2004 A5E

Software. Process Device Manager SIMATIC PDM 8/11. Overview

SIMATIC PDM Process Device Manager

SIMATIC Software. SIMATIC PDM The Process Device Manager. The ideal tool for engineering, parameterization, commissioning, diagnostics and service

SIMATIC PDM Process Device Manager

Parameterization, Configuration and Visualization with SIRIUS

1 Parameterizing field devices

Process automation engineering tools

Workshop PROFINET in Process Automation. Intern / Siemens AG Alle Rechte vorbehalten.

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Industrial IT Ó Melody Composer

CPUs - CPU PN/DP

Safety Integrated. SIMATIC Safety Matrix. The Management Tool for all Phases of the Safety Lifecycle. Brochure September Answers for industry.

Ponto Series. A new concept for automation

CMS Central Monitoring System

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA) MODULE M1

DUKANE Intelligent Assembly Solutions

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

How-To-Do. Hardware Configuration SLIO CPU 014

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

TMA Management Suite. For EAD and TDM products. ABOUT OneAccess. Value-Adding Software Licenses TMA

SIMATIC PCS 7 The process control system for all sectors. Brochure June 2006

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

SIMATIC PCS 7. SIMATIC Maintenance Station PDM A stand-alone Solution. Siemens AG All Rights Reserved.

New Perspectives with SIMATIC PCS 7 Process Control System SIMATIC PCS 7. Answers for industry.

Parameterizing options Parameterization options based on the communication protocols used

Device configurator DRC200

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

PROFINET IO Diagnostics 1

Siemens AG The SIMATIC PCS 7 Process Control System. Brochure February 2012 SIMATIC PCS 7. Answers for industry.

How To Use Safety System Software (S3)

Think Automation and beyond... IDEC WindSRV. KEPServerEX OPC Server

SIMATIC Sensors. The new software SIMATIC RF-MANAGER Simple management of RFID systems. Brochure April Answers for industry.

Efficient remote access to machines and plants with SIMATIC

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Permissible ambient temperature Operation Storage, transport

CP Page 1342 Mar 2008 Siemens ITS

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS

SIMATIC Expert Communication Connecting S7-400H to PC Station (WinCC)

A Real Time, Object Oriented Fieldbus Management System

FAQ Communication over IE

The CP provides access to different communication services of the PROFIBUS bus system:

applicomio Profibus-DP

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

PROFIBUS The perfect fit for the process industry

DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles

SHORT TRAINING COURSES

Automation Unit TM 1703 ACP Flexible automation and telecontrol

CGLMS. Building Control and Alarm System. Caccialanza & C., SpA Via Pacinotti 10 I Segrate / Milano (Italy)

S7 for Windows S7-300/400

SPECIAL SPECIFICATION 8498 Video Management Software

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

Module 1 Overview ControlLogix5000

Using HART with asset management systems

Software INTERACT. MachineLogic. The Shortest Distance Between Man and Machine

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

DCS110 CATVisor COMMANDER

Engineering and service software For KNX and LPB plants

s Preface SIMATIC Configuring Hardware and Communication Connections with STEP 7 Contents Basics of Configuring Hardware with STEP 7 1

T3 Mux M13 Multiplexer

ISA CERTIFIED AUTOMATION PROFESSIONAL (CAP ) CLASSIFICATION SYSTEM

PROFIBUS AND MODBUS: A COMPARISON

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Manual. VIPA WinNCS. Order no.: VIPA HB91E Rev. 04/03

General Specifications

User s Guide for version 5 Page

OfficeServ Application Suite

Software Operations Manual

ProfessionalPLUS Station Software Suite

Development of a Gateway to PROFIBUS for Remote Diagnostics

High-precision valve control using intelligent positioners. sipart

ProfessionalPLUS Station Software Suite

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Field Information Manager Product guide. Field Information Manager version 1.1

Managing Relion IEDs Protection and control IED manager PCM600

The CP FO provides access to different communication services of the PROFIBUS bus system:

Communication OPC - Server

3D MultiVision SOFTWARE OPERATING INSTRUCTIONS

Symphony Plus S+ Engineering: Composer Harmony

SIMATIC S It s the interplay that makes the difference. SIMATIC Controller. Answers for industry.

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

System Integration Software

1 How configure S7 PLC in the configuration tool

Access Schneider Electric PLCs through an existing Talk2M connection

Intelligent Device Management with DCS, PLC, and RTU

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED

EtherCAT Cutting Costs with High-speed Ethernet

IndustrialIT System 800xA AC 870P/Melody Engineering

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

Network and Facility Management: Needs, Challenges and Solutions

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

The software beyond the climatic. Environment simulation

Transcription:

software 7 Application...7/2 Graphical user interface...7/2 Communication...7/3 Diagnostics...7/4 Technical data...7/5 Ordering data...7/5 Siemens FI 01 2001 7/1

Application, graphical user interface Application (Process Device Manager) is a uniform, crossvendor tool for configuring, parameterizing, commissioning and diagnostics of intelligent field devices and components. allows a wide variety of process devices to be configured using one software system and one uniform graphical user interface. This results in reliability, and significantly saves costs for investment and staff training, as well as follow-up costs. can be used in two manners: 7 Independent of system suppliers on a personal computer or programming device with the Windows 98, NT or 2000 operating system 7 With an option as an integral tool in STEP 7, the SIMATIC S7 configuring and programming tool. In this manner, SIMATIC PDM is also integrated into the SIMATIC PCS 7 process control system. 7 With the routing function, permits access from a central engineering station to all field devices with communications capability in the plant. This is possible for field devices with PROFIBUS-PA or HART communication as well as for PROFIBUS-DP devices such as SIPART controllers or SIMOCODE motor protection and control devices. The display of device parameters and functions is uniform for all supported process devices and independent of their communication link, e.g. via PROFIBUS-DP, PROFIBUS-PA or the HART protocol. The main functions of are adjustment and modification of device parameters, comparison of reference and actual parameters, plausibility testing of inputs, simulation, automatic diagnostics, management, and commissioning functions such as measuring circuit tests of process devices. additionally permits process monitoring with display of selected values, alarms and status signals of the device on the screen. Software 7 Parameter view (Fig. 7/3) The parameters of a selected process device can be displayed, modified and saved here. Communication to the device is also established here. This parameter display is started by double clicking a process device in one of the other views. The design of the graphical user interface is based on DIN V19259 or IEC. The devices with different communication interfaces are displayed homogeneously and user-friendly within the graphical user interface. The main attention is paid to efficiency. Fig. 7/1 STEP 7 view using HW-Config Graphical user interface The graphical user interface is designed according to the standard guidelines of Microsoft Windows and complies with the requirements of the VDI/VDE GMA 2187 guidelines. Menu structures and toolbars are used as is an Explorer view which simplifies navigation between parameter groups (Fig. 7/3). Even complex devices with several hundred parameters can thus be processed clearly and rapidly. The user interface supports several views: 7 STEP 7 view (Fig. 7/1) Process devices are configured using HW-Config within STEP 7 and displayed graphically or as a table. 7 Process device network view (Fig. 7/2, top) The hierarchical structure of networks, communication components, down to the process devices is configured here. Configuring data can be imported from there when integrating in STEP 7; multiple inputs are thus avoided. 7 Process device plant view (Fig. 7/2, bottom) The devices configured in HW-Config or in the process device network view are automatically imported into the process device plant view. Free grouping of these devices will be available soon, and the process devices can then be arranged hierarchically in a tree structure. Dynamic diagnostics information is also displayed in this plant view. Associated icons are displayed for the device depending on the diagnostics information. A list of diagnostics messages can also be called there. Fig. 7/2 Fig. 7/3 Process device network view and plant view Parameter view 7/2 Siemens FI 01 2001

Communication Fig. 7/4 Communication in an automation solution with Central device operation Fig. 7/4 shows a summary of the possible connection points of (version V5) in a plant. The icon shows wherever can be connected. With V5 you can use the so-called Routing for the first time. Routing permits uniform communication from a central engineering station up to the process devices. Reconnection of the PC s DP interface to the respective DP segment is superfluous, and thus a possible source of error is eliminated. Data collection times are eliminated, the device data are available directly online. In particular, the diagnostics data of the devices are available immediately. This decisively increases the plant safety, and the costs for data collection are significantly reduced. The PCs/programming devices on which is to be installed are connected to the plant bus. This is either an ES engineering station or an engineering console with SIMATIC PDM. Common operations on a project database using different PCs/programming devices are possible via a LAN. Devices can be connected in different manners at the field level: PROFIBUS-PA devices to DP/PA coupler and DP/PA link or HART devices to the HART analog input/output modules of the ET 200M. HART devices can also be connected to conventional analog input/output modules. A HART multiplexer is shown on the right in Fig. 7/4 via which all connected HART devices can be reached. The SIPART DR controllers and the SIMOCODE are shown as representatives for PROFIBUS-DP devices. The PROFIBUS-DP is connected here to a SIMATIC S7-400 automation system. Several DP segments can be connected to the S7-400. Further SIMATIC S7-400 systems can be connected to the plant bus. Communication supports several communication protocols and components for communication with the following devices: 7 Devices with PROFIBUS-DP interface These are connected directly to PROFIBUS-DP. An example is the SIPART DR20 compact controller. 7 Devices with PROFIBUS-PA interface, e.g. the SITRANS P transmitter 7 Remote I/O stations such as e.g. the ET 200M The PROFIBUS-PA devices supported by are connected via a DP/PA link or DP/PA coupler to the PROFIBUS-DP segment. The integrated PROFIBUS-PA devices can be parameterized, as well as almost all PROFIBUS-PA devices via the following PA profiles of versions 2.0 and 3.0: Pressure and temperature Level and flow Actuators Discrete I/Os Analyzers (only PA profile version 3.0) 7 Devices with HART interface These devices can be connected in different manners: Via the SIMATIC ET 200M distributed I/O system with the HART modules Via a HART modem with which a point-to-point connection is established between the PC or engineering station and the HART device Via multiplexers which pass on the telegrams transparent to the HART devices. Siemens FI 01 2001 7/3

Diagnostics Software In addition to the fully integrated HART-capable devices, almost all HART devices are also parameterizable. 7 Controllers with serial SIPART DR communication via RS 232 / RS 485. The SIPART DR19, DR20, DR21 and DR22 controllers can also be parameterized via the so-called SIPART DR network. A summary of the possible connection points of in a plant is shown in Fig. 7/4. Diagnostics Diagnostics rules can be stored for all configured devices: 7 Standard diagnostics: diagnostics rules predefined by for checking general diagnostics parameters. The following checks are included: Identification of device (incl. device type, tag) With PROFIBUS-PA devices (profile V2/V3), evaluation of all block objects: - Diagnostics (physical block) - Block mode - Simulation (i.e. a device running in this mode is detected and displayed accordingly) - Limits (common alarms), without automatic acknowledgment Access privileges With HART devices: - Evaluation of device status -Simulation 7 Device type diagnostics: evaluates vendor-specific diagnostics information which is not defined in profiles or in other general specifications. These are predefined diagnostics rules which the vendor can formulate as methods in the device description. The vendor can save several device-specific diagnostics rules for selection. 7 User-defined diagnostics: in this case, users create the diagnostics rules themselves using the diagnostics editor. All variables of a device can be linked in. The accessibility of all components is checked by the diagnostics agent irrespective of the type of diagnostics rule involved. Correct configuring of the network topology as well as the communication are checked. Device Description Language The Device Description Language exists for parameterization of devices. This language is standardized, multi-vendor, and very widely used. This language describes the parameters, the communication, and the representation of the devices. Using this description, automatically generates its graphical user interface. The Device Descriptions describe the dependencies between the parameters. In this manner, can recognize faulty inputs early enough and signal them to the user. The use of Device Descriptions means that all common field devices can be incorporated into independent of their communication interface. Device Descriptions for devices and components (e.g. remote stations) from many different vendors are being permanently developed for. The device vendors are responsible for the Device Descriptions. A current list of supported devices can be found on the Internet (www.fielddevices.com). differentiates between two different user groups: Specialist and Maintenance engineer. The maintenance engineer can only modify the operating data, the specialist can access all parameters and functions. A freely-selectable password can be used as the access privilege for the specialist. 7/4 Siemens FI 01 2001

Technical data, ordering data Technical data Task Parameterization, commissioning and diagnostics of process devices and components with PROFIBUS-DP, PROFIBUS-PA, HART and SIPART DR communication Required hardware Personal computer / programming device with Pentium processor and 32 Mbyte RAM (recommended: 64 Mbyte or more) Operating system Windows 98, Windows NT 4.0, Windows 2000 with integration in STEP 7: STEP 7 version 5 memory requirements Approx. 110 Mbyte, plus 70 Mbyte for without option "Integration in STEP 7" Industrial Ethernet connection or TCP/IP connection (interface card for PC) PROFIBUS-DP connection For PG 720/740/760 programming device Communications processor CP 1411 CP 1613 1) Built-in MPI interface or Ethernet interface On request 6GK1 161-3AA00 For personal computer Communications processor CP 5511 2) CP 5611 2) On request 6GK1 561-1AA00 Gateway from PROFIBUS-DP DP/PA coupler Ex version 6ES7 157-0AD81-0XA0 to PROFIBUS-PA Non-Ex version 6ES7 157-0AC80-0XA0 IM 157 (interface module for DP/PA link) 6ES7 157-0AA81-0XA0 Gateway from PROFIBUS-DP to HART IM 153-2 interface module HART analog input module HART analog output module 6ES7 153-2AA02-0XB0 6ES7 331-7TB00-0AB0 6ES7 332-5TB00-0AB0 HART point-to-point connection Via HART modem 7MF4 997-1DA 1) The required drivers are included in the delivery of the communications processor 2) The required drivers are included in the delivery of and in STEP 7 Ordering data Order No. Order No. V5.1 1) Basic software for operation and parameterization of process devices and components including communication via HART modem, with RS 232, for 16 tags 2) Option(s) for Expansion of V5.1 basic software: Integration in STEP 7 / SIMATIC PCS 7 (required if STEP 7 is installed on the programming device/pc) Routing via S7-400 3) Communication using PROFIBUS-DP and -PA Communication using standard HART multiplexer Diagnostics 6ES7 658-3AX01-0YC0 6ES7 658-3BX00-2XD0 6ES7 658-3CX00-2XD0 6ES7 658-3DX00-2XD0 6ES7 658-3EX00-2XD0 6ES7 658-3FX00-2XD0 Tag option(s) for V5.1 Up to 128 tags 2) Up to 512 tags Up to 1,024 tags Up to 2,048 tags Up to 4,096 tags Up to 8,192 tags Up to 16,384 tags maintenance contract demo version 6ES7 658-3XA00-2XD0 6ES7 658-3XB00-2XD0 6ES7 658-3XC00-2XD0 6ES7 658-3XD00-2XD0 6ES7 658-3XE00-2XD0 6ES7 658-3XF00-2XD0 6ES7 658-3XG00-2XD0 6ES7 658-3XX00-0XX0 6ES7 658-3GX01-0YC8 1) Only the basic software need be ordered when upgrading from a previous version to the current version V5.1 (with same functionality) 2) Tags are basically understood to be terminal equipment such as transmitters, e.g. SITRANS P 3) Only together with the option "With integration in STEP 7" Note: for the function "Data set routing", the automation system must be equipped with the CP 443-5 Extended communications processor and CP 443-1 7 Siemens FI 01 2001 7/5