MicroLab The world s most versatile portable Spirometer
MicroLab A new generation Spirometer designed for Child incentive animatio the professional Developed for the professional, the new generation MicroLab employs Micro Medical s acclaimed precision Gold Standard Digital Volume Transducer which is especially suited to measuring very low flow rates in patients with COPD. The MicroLab has a class-leading, very high resolution screen and can display both Volume/Time and complete Flow/Volume Loops (using either the open or closed loop test techniques).the instrument can measure up to 36 parameters and has a database storage capacity for over 1000 patients. A built-in high resolution printer delivers hard copy results. A4 sized printouts can be obtained directly via Hewlet Packard or Canon printers. (compatible models specified by Micro Medical). A new child incentive graphical display is featured and an optional Airway Resistance measurement module is offered. MicroLab Cat. No. ML3500 Features High resolution printer Text entry, enabling comment writing Internationally recognised on-screen test quality assurance prompts for poor test attempts (e.g. slow start, abrupt end etc.) Bronchodilator and/or steroid assessment Predicted value and language selection Body mass index and dyspnoea score calculation Lung age assessment and textual result interpretation by ATS 10, BTS-NICE 11 or Enright 12 Fully customisable printout format Complete with all accessories in a sturdy carry case Optional Spida 5 spirometry PC software SpidaXpert interpretation and diagnostic upgrade available for Spida 5 In-built high resolution printer Offered as an option for MicroLab is Spida 5, a powerful Spirometry PC software package. Available as an upgrade for Spida 5 is SpidaXpert, an advanced interpretation and diagnostic program for spirometry. Text and number entry keys A new child incentive graphical display is featured and an optional Airway Resistance measurement module is offered. A comprehensive range of advanced features normally only seen on more expensive laboratory based equipment are included in MicroLab (of which there are more than 40,000 units in use around the world). The new generation of portable precision Setting new standards in spirometry The new Gold Standard transducer from Micro Medical gives the most pr measurements for your Asthma and COPD patients. Especially effective at low flows, it complies with all current ATS and othe for accuracy. This means that Micro Medical s world beating spirometers accurate respiratory measurement - bar none. Digital Volume Transducer Spirometers are NOT ALL THE SAME Spirometers are here NOW!
mation Built-in internationally recognised test quality prompts Audio alarm High Visibility Screen 1. Open loop spirometry 6. Comprehensive results screen 2. Closed loop spirometry 7. Patient data entry screen Screen function keys Screen navigation keys Rechargeable battery Indicator light 3. Relaxed inspiratory/expiratory vital capacity 8. Airway resistance results screen (with optional MicroRint module) 4. Simple parameter selection 9. Airway Resistance waveform (with optional MicroRint module) ost precise volume and flow other recognised international standards eters are the definitive benchmark for AME. 5. Easy system customisation
Spida 5 - SpidaXpert Very user-friendly, advanced features Spida 5 is the highest quality advanced Spirometry software you can buy.the 32-bit package is simple to use and employs a state of the art multi-window, screen interface. Fully searchable Patient Database Animated child incentive window Previous tests Best volume time curve Up to 41 Spirometry indices can be measured, previous test curves overlaid for comparison and both open and closed Flow/Volume Loop test techniques used. Three types of animated child incentive devices and the long term trending of patient results also feature Spida 5 can be easily linked to other patient journal or GP administration systems, occupational health systems or other medical databases. Spida 5 is compatible with Microsoft Windows 95, 98, 2000, Me, XP and NT and will link to all Micro Medical Spirometers* Offered as an optional upgrade for Spida 5 is SpidaXpert a comprehensive, quality assurance, interpretation and diagnostic software program for spirometry. Developed in partnership with a prestigious group of Dutch Respiratory Physicians 13, SpidaXpert automatically assesses the quality and reproducibility of the spirometry tests according to international standards. Concise analysis and diagnosis is achieved using clear coloured graphical indicators and comprehensive textual interpretation. SpidaXpert which includes all the features of Spida5, is a powerful support tool, a true physicians friend. System Requirements Processor: Pentium 133 MHz Ram: 32 MB CD-ROM: 4x or faster Free Disk Space: 50MB Video: SVGA 800x600, 256 colours One free serial port for standard Spirometers One free USB port and USB Supported Operating System, for USB enabled Spirometers. * Spida 5 and SpidaXpert are compatible with all Micro Medical spirometers except the Micro and Micro DiaryCard. Results analysis Spida 5 Cat. No. SD5000 Features Amendable notes Multi-window layout is extremely easy and fast to use Animated child incentive display Real-time Flow/Volume and Volume/Time traces Open and closed Flow/Volume loop test technique is possible Overlaying of previous test curves for comparison Long term trending facility Lung age calculation and textual interpretation Powerful search capability Up to 41 spirometry parameters can be measured Can be easily linked to other patient journal or GP administration systems, occupational health systems or other medical databases Configurable printout format Predicted area SpidaXpert interpretation and diagnostic upgrade available for Spida 5 (Cat. No. SD5000XP) or as a complete product including Spida 5 features All flow volume loops Best flow volume loop
MicroRint A simple test to measure airway resistance Available for MicroLab is the optional MicroRint module for the easy measurement of airway resistance. Micro Medical s unique design has taken a hitherto specialised measurement out of the pulmonary function laboratory and into the clinic or home. MicroRint enables airway resistance to be measured with the same ease as peak flow but without effort or technique from the patient.the subject simply breathes passively through a MicroRint Module Cat. No. MRT6000 Features Rechargeable battery or mains usage Bacteriological viral filters to eliminate cross infection fears Predicted values with pre-and post- bronchodilator analysis Configurable measurement methodology 1000+ test memory with results printout direct to Canon or Hewlett Packard printers compatible models specifiied by Micro Medical Optional Rida, database and analysis software mouthpiece or facemask.the result is automatically computed and displayed against predicted normal values.the procedure, that can be performed on neonates to adults, takes only a few minutes. Available as an option for the MicroRint module is Rida, a comprehensive database and analysis software package. In this method airway resistance is determined by a momentary interruption to flow (Q) in the airways. At this point alveolar pressure (Pa) equilibrates with the pressure in the airways and the mouth (PaO) and airway resistance (kpa/1/s) is calculated from PaO/Q (pressure/flow). Results using MicroRint correlate well with other airway resistance methods 7 and with other measurements of lung function such as FEV 1. 8 To know more about MicroRint please visit www.micromedical.co.uk
Specifications Spirometry Measurements: VC, FEV 0.75, FEV 1, FEV 3, FEV 6, FVC, PEF FEV 0.75/VC, FEV 0.75/FVC, FEV 1/VC, FEV 1/FVC, FEV 3/VC, FEV 3/FVC, FEV 0.75/FEV 6, FEV 1/FEV 6, MEF75, MEF50, MEF25, MEF25-75, FEF50/VC, FEF50FVC, MVV ind, FET, MET, IC, FIV 1, FIVC, PIF, FIV 1,/FIVC, FIF25, FIF50, FIF75, FIF50/MEF50,V T, ERV, IRV [all expiratory measurements with baseline, post bronchodilator 1 and 2, % predicted, % change and normal range] Bibliography 1 Dirksen A, Madsen F, Pedersen OF,Vedel AM, Jenson AK. Long term performance of a hand held Spirometer.Thorax 1996;51:973-976. 2 Otulana BA, Higenbottam T, Ferrari L.The use of home Spirometry in detecting acute lung rejection and infection following heart-lung transplantation. Chest 1990;97:953-7. Tests per subject: VC-unlimited (best reported) FVC-unlimited (best 3 from baseline, post 1 and post 2 tests) Predicted Values: Various depends upon national preference (Including NHANES III) 3 Pollard AJ, Mason NP, Barry PW, Pollard RC, Collier DJ, Fraser RS, Miller MR, Milledge JS. Effect of altitude on spirometric parameters and the performance of peak flow meters.thorax 1996;51:175-178. Transducer: Resolution: Accuracy: General Storage : Printer Output: Micro Medical Gold Standard Bi-Directional Digital Volume 10ml volume 0.03l/s flow +/-3%.To ATS recommendations Standardisation of spirometry 1994 update for flows and volumes 1000 patients tests including Flow/Volume loops and Volume/Time curves For the latest listing of compatible Canon and Hewlett Packard printers please visit the Micro Medical website at www.micromedical.co.uk 4 Godschalk, L, Brackel HJL, Peters JCK, Bogaard JM. Assessment of accuracy and applicability of a portable electronic diary card Spirometer for Asthma treatment. Respiratory Medicine, 1996;90:619-622. 5 Morris JF,Temple W. Spirometric Lung Age estimation for motivating smoking cessation. Preventative Medicine, 1995;14 655-662. 6 BTS Guidelines for the management of Chronic Obstructive Pulmonary Disease (The COPD Guidelines Group of the Standards of Care Committee of the BTS) Thorax 1997;53 (Suppl 5):S4-6. Display: High resolution graphic LCD 240x160 pixels Power Supply: 100-240V, 0.5A, 50-60Hz. Output 9V 1.12A (Class 1) Battery Pack: Rechargeable NiMH 7.2V 1A-HR Dimensions: 150 x 251 x 40 mm.transducer 50 x 60 x 90mm Weight: Unit weight 0.75kg. Packed weight 2.55kg Temperature: 0 0 to +40 0 C Operating Humidity: 30% to 90% RH Storage Temperature: 0 0 to +70 0 C Storage Humidity: 10% to 90% RH The MicroLab (Cat. No. ML3500 ) is part of an extensive range of respiratory monitoring equipment manufactured by Micro Medical Ltd. Micro Medical Ltd pursues a policy of continuing improvement in design, production and performance of its products.the right is therefore reserved to vary details at any time and without notice. 7 Wilson CM, Bakewell SE, Mr Miller etal.increased resting bronchial tone in normal subjects acclimatised to altitude. Thorax 2002, 57: 400-404. 8 Bent Klug and Hans Bisgaard. Measurement of Lung Function in Awake 2-4 Year-Old Asthmatic Children During Methacholine Challenge and Acute Asthma. Paediatric Pulmonology 21:290-300 (1996). 9 Edward R. Carter, Arlene A. Stecenko, Brad H. Pollock, Marc J. Jaeger. Evaluation of the Interrupter Technique for the Use of Assessing Airway Obstruction in Children. Paediatric Pulmonology 17:211-217 (1994). 10 American Thoracic Society. Standardization of spirometry: 1994 update. Am J Respir Crit Care Med 1995; 152: 1107-1136. 11 National clinical guideline on management of chronic obstructive pulmonary disease in primary and secondary care (National Institute of Clinical Excellence (NICE) /British Thoracic Society (BTS) Thorax 2004;59(Suppl l): 1-232 doi: 10.1136/thx.2004.022707 12 Office spirometry, a practical guide of the selection and use off spirometers. Paul Enright 13 Members of the Dutch consensus group can be found by visiting ww.spirxpert.com/spirxpertgroup.htm Micro Medical Limited PO BOX 6, Rochester, Kent, ME1 2AZ, UK Telephone 01634 893500 Fax 01634 893600 International +44 1634 893500 Email sales@micromedical.co.uk www.micromedical.co.uk ML3500 09/04