Dynatek 6080RS multimeter



Similar documents
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Interface Protocol v1.2

BW-500 BED WEIGHER USER MANUAL

Keep it Simple Timing

PHONE MANAGER INDEX. page

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

User Manual WatchPower

1. SAFETY INFORMATION

User s Manual. Management Software for Inverter

5000V Graphical Megohmmeter Model 5070

User's Guide. Integrating Sound Level Datalogger. Model Introduction

PM1122 INT DIGITAL INTERFACE REMOTE

User Manual. Thermo Scientific Orion

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7

User's Guide DylosLogger Software Version 1.6

Driver Pant 8 and antenna switcher Ant 8. User manual

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

BASLER ACE QUICK INSTALLATION GUIDE

Using HyperTerminal with Agilent General Purpose Instruments

Manual. Sealer Monitor Software. Version

EMF16 and Model 201 Graphics Software for Win 98/NT/ME/2K/XP/Vista/Win7/Win8 and Win10

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

Model UT60A: OPERATING MANUAL. Table of Contents. Page

File Management Utility. T u t o r i a l

Guide to Installing BBL Crystal MIND on Windows 7

WinPFT File Transfer Utility (Catalog No ND7)

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Sierra S-Series Smart Interface Software User Manual

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Temperature Datalogger Users Manual

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software

User s Manual. Management Software for Uninterruptible Power Supply Systems

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

PP8X Printer Driver Installation Instruction

ViewPower User Manual

Bluetooth to Serial Adapter

Galileo Print Manager

Fluke 89-IV & 189 Event Logging

NEC USB PortBar with the Driver Installation Diskette

Voice Over Internet Protocol (VoIP) Configuration

A p p l i c a t i o n s : 3.5 inch full-view TFT-LCD

Chapter 2 Installation

Mobile POS Tablet Barcode Scanner

Using the UPSMON-Plus Monitoring Software

HYDROSOFT Version INSTALLATION AND OPERATING

Win 7 - STIMA CLS / CMP Driver Installation Quick Guide

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

GE Sensing. SiCalPro. Monitor and control software. User manual - K0452

Data Transmission Using Codan HF Radios. R. Aston GCP/INT/651/NOR EMPRES. Improving Pesticide Application Techniques for Desert Locust Control

InfplusWin OPERATING MANUAL

SAPIP GUI INSTALLATION. Table of Contents

Newton Backup Utility User s Guide. for the Windows Operating System

Handheld LPC Utility Software for Windows. Operation Manual

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

Korosi Monitoring System (KMS) Software Manual

Vibration Monitoring System Adash 3600

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

Intelligent Digital Multimeters

You can search the event by POS and you can also add the Time Search condition to narrow the search range. By

/ / / Audio distribution system A44/A88 pc software

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

TDA W Hi-Fi AUDIO POWER AMPLIFIER

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Chapter 3 Software Installation

PTPhoneManager II. User guide

1. Installing The Monitoring Software

GSM HOME SECURITY SYSTEM

Installing Your Multifunction to Your Network for the First Time

PenMount Touch Screen Controller Board Installation Guide

PPM Users Manual Signature Software

Maintaining the Content Server

Dominion KX II-101-V2

Licensed Functionality: Remote Monitoring

USER S MANUAL. InverterWin REV 3.0. AC Inverter Support Software For GPD505/P5 and GPD506/P5 TM.IW.01

GUARD1 PLUS SE Administrator's Manual

Real Time Monitor. A Real-Time Windows Operator Interface. DDE Compliant. (for remote data display)

RACEAIR REMOTE PAGER SYSTEM

STIM202 Evaluation Kit

PCAN-ISA. CAN Interface for ISA. User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

OPTAC Fleet Viewer. Instruction Manual

VM0808H HDMI Matrix Switch RS-232 Control Tool V User Manual

History of Revisions. Ordering Information

Bluetooth HC-06 with serial port module Easy guide

Alpha 10 SERVICE MANUAL. Downloaded from MAX 10 Meter Amateur Transceiver AM/FM/CW/SSB 6 BAND PROGRAMMABLE MODEL AM-1000.

TEMP MONITOR_S2 Software operation instructions

How To Install Touchkit For Linux On Windows Xp (Windows) On A Windows Xp (Windows Xp) On Windows Or Windows 3.2 On A Microsoft Touchkit (Windows 2.5

TDP-136 TRANSCEIVER DATA PROGRAMMER

Windows 95 Revision B Installation Instructions

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

Testo FlashUpdate. Instument Software Update and Download Instructions How to Download Instrument Software and Updates from the Internet

DriveWare. User's Guide. DriveWindow Light 2

Transcription:

Dynatek 6080RS multimeter Table of Contents Connection...1 Installing the software...1 Starting the communication...1 Other possibilities...2 File Management...2 Printer...2 Graph screen...3 Programmers information...4 Specification of RS-232...4 Data Format...4 Function codes...5 Range codes...5 Auto or manual codes...5 Example program of application...6 WARNING: NO RIGHTS ARE TO BE CLAIMED ON THE QUALITY OF THIS SOFTWARE. YOU HAVE TO ACCEPT THIS SOFTWARE AS IT IS. THIS SOFTWARE WILL RUN ON WINDOWS VERSION 3.1 AND HIGHER. For software programmers there are programming instructions at the and of this manual. Also technical information is given on how to communicate with the RS-232 interface. Connection Connect the 9 pin RS232 communication cable to a free communication port from your computer. The 3.5 mm connector should be connected to the connector on the Dynatek 6080RS multimeter. Installing the software Put the 3.5 inch disk into your drive A: or B: Start from Windows with <File> <Start> A:SETUP (of B:SETUP). The installation program asks for the directory name (Default = C:\RS6080). You may change this for your own convenience. A program file and program with the name DYNATEK will be created. No restart from Windows is required after installing the software. Double-click on the DYNATEK-icon to start the program. Starting the communication 1. Switch on the preferred communication-port into the left middle of the screen, with

the mouse pointer. If there is no communication-port available an error message will appear. Please check your connection or try another port. 2. Switch on the multimeter from the OFF position while pressing the REC and COMP button at the same time. 3. Switch on the software by clicking the START button from the communication field. (Left top-corner) Below the time and date indication the digital-readings will start with the range indication (e.g. mv or Hz). Other possibilities S/Time You can adjust sampling-time. If this indication is on 0 there are 4 readings/sec. You may change this setting to e.g. 1 or 3 sec. In this case data will be refreshed every 1 or 3 seconds. File Management SAVE It is possible to SAVE your measurement output. By clicking on the SAVE button you have to give in the filename (according to DOS a maximum of 8 characters is allowed). Furthermore there are two check-boxes to activate the recording of TIME and UNITS (=range). In this case also Time and Range (=mv or V) will be recorded. Click on OK. The Start button will change to red. WARNING: A maximum of 200 readings will be recorded. So switch on the right S/Time for maximum measuring time. You will be warned by a beep from your built in loudspeaker when this amount of readings has been reached. Push the SAVE button again to stop recording. If you have recorded e.g. 20 readings in the first period and later restart recording with the same filename, the new readings will be added at the and of the existing file. In this is way you can record a measurement with different intervals over a longer period of time. You are able to print out these readings afterwards. (See LOAD below) LOAD The files you saved can be recalled bij pressing the LOAD button. You are asked for the filename. Enter your filename and click the OK-button. All readings (with a maximum of 200) will appear on the screen. With the PRINT button you are able to make a hardcopy. Printer RdgData Off All measured data can be printed immediately. The printed data is also directly related to the S/Time. Press RdgData Off and this button will change to red with the indication RdgData On. By pressing this button again the printing will stop. The value and time will always be printed. Indication of the range will not be added. ATTENTION: In a network situation, the printing will mostly start after finishing the total printing job.

Screen With this button a hardcopy from the actual screen will be made. This also includes, graphical information. REC With this button you activate three extra windows with the values: MAX; MIN en AVG. You are able to measure over a total period of time the MAX (=Maximum) value; the MIN (=Minimum) and the AVG (=Average) values will be displayed. CMP With the edit button you can adjust the HI-limit and LO-limit. In the last window the Judgement in relation to the HI or LO value is displayed: HI when the upper limit is exceeded and LO when the lower-limit is exceeded. REL After clicking on the Edit button you are asked for a Reference value. The ERROR field now displays the difference in relation with this reference. The value can be positive or negative. Graph screen Setup You can change the X- and Y-axes of the graphical screen. The Y-ax changes the range and the X-ax changes the readings. You can change to 280; 350; 700 and 1400 readings. The total result also depends on the S/Time as mentioned before. Switch on the graphical screen by pressing the ON button. The button will change to red. If the screen is completely filled it will switch off automatically and the OFF button changes to red. The screen will be cleared with the CLEAR button. Just start it from the beginning with ON. Leave the program by clicking the left upper button from the screen. You are asked to save the Default values. Just click on Yes if you prefer this. The next time you start the program all previous settings will be regained.

Programmers information For your own application, please read following carefully: Specification of RS-232 Baud rate 1200 Parity bit none Data bit 7 Stop bit 1 Data Format FAR_DDDDDD T \_ Data delimiter (= <CR>) \ Reading data (with decimal pointer & sign) space \ Range code \ Auto or manual indication \ Function Code

Function codes Code Function Code Function 0 AC V 6 diode 1 resistance 7 DC ma 2 DC V 8-3 DC mv 9 AC ma 4 AC A A capacitance 5 DC A B frequency Range codes Function code Range code 0 1 2 3 4 5 2 / 4 4,000 V 40,000 V 400,0 V 1000 V 7 / 9 40,00 ma 400,0 ma 4 / 5 4,000 A 10,00 A 1 400,0 Ω 4,000 KΩ 40,00 KΩ 400,0 KΩ 4,000 MΩ 40,00 MΩ B 200,00 Hz 2,0000 KHz 20,000 KHz 200,00 KHz A 400,0 nf 4,000 µf 40,00 µf 3 400 mv 6 4,000 V Auto or manual codes Code Mode 0 Manual range 1 Auto range

Example program of application cls gosub ComOpen on com(2) gosub GetCom com(2) on Waitloop: goto Waitloop ComOpen: close #1 open "com2:1200,n,7,1,rs,cs,ds,cd" as #1 GetCom: com(2) off input #1,rd$ if len (rd$) > 9 then Rdgdata$=right$(rd$,7) FunCode$=left$(rd$,1) ModCode$=mid$(rd$,2,1) RgeCode$=mid$(rd$,3,1) print Funcode$;" ";ModCode$;" ";RgeCode$;" ";RdgData$ end if com(2) on return