GO SILENTLY AT HIGH PRESSURE & HIGH SPEED



Similar documents
ORIGIN OF NOISE AND VIBRATIONS KNOCKED DOWN BY CONTINUUM PUMP LA POMPA CONTINUUM HA ELIMINATO LE ORIGINI DEL RUMORE E DELLE VIBRAZIONI

SMT8B pump series. Applications / applicazioni. Flow media/fluidi

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES


Variable Displacement Pump AA10VSO

Fixed displacement vane pumps

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

BD1 TABELLA DI PERFORMANCE PERFORMANCES TABLE BD

PDP and SD Series Pump Station

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Series TMM Axial Piston Motor. Technical Information

PUMP AND MOTOR DIVISION

Series PVP Variable Volume Piston Pumps

SMT pump series / Serie SMT

Rickmeier Solutions. Gear pumps for superior Lubrication

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Internal gear pump PGF Series 2X and 3X

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Rexroth Hydraulic Pump A10VO Series User Manual

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

PART 2 FORKLIFT HYDRAULIC SYSTEM

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Unit 24: Applications of Pneumatics and Hydraulics

Radial piston pumps type R and RG


Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

PVH131/141 Variable Displacement Piston Pump - 11 Design

Vane Pump & Motor Design Guide

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

HTM PP/PVDF Thermoplastic mag drive centrifugal pumps HTM PP/PVDF Pompe centrifughe a trascinamento magnetico in materiali termoplastici

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Unit 24: Applications of Pneumatics and Hydraulics

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

SJT / SJM / SJP Large Vertical Pumps

High Torque Vane Motors MV015, MV037, MV057, MV125

Air Eliminators and Combination Air Eliminators Strainers

PN 10 - Art. A020 TIS PN 16 - Art. A021 TIS

Atlas Copco Stationary air compressors

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

HTM PUMPS PP-PVDF Non-metallic mag drive centrifugal pumps

Quiz On Information Learned From Chapter 1

Series 40 Axial Piston Motors. Technical Information

Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

DRS/A M GRINDER. Q = Portata / Flow rate / Débit Modello l/min Model m Modèle

Imo Pump. Imo Rotary & Centrifugal Pumps Quick Selection Guide. The reliable pump people

MANTA Piston Distributor for Oil and Fluid Grease

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

Rules for Classification and Construction Additional Rules and Guidelines

Unit 24: Applications of Pneumatics and Hydraulics

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

\ srl High Technology Gear Reducers and Cardan Shafts CERTIFIED QUALITY SYSTEM: UNI ISO EN 9001:2008 ICIM 2779/2; IQNET N. IT UNIVERSAL SHAFT

FP12 FERRA SERIES HEAVY DUTY GEAR PUMP

SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

Uniquely designed and engineered specifically for the pulp and paper industry.

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Chapter 5: Flow Valves

Produktkatalog (GB/IT)

MEMBRANE VACUUM MINI PUMPS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Hydraulic Control Solutions

Rotary screw compressors kw 5,5 7, , bar MODULO

PRESSURE REDUCING CONTROL VALVE

PVM Piston Pumps Service Manual

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX

MINEX -S. Magnetic coupling. You will find continuously updated data in our online catalogue at

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

220 Series Piston Pump Typical Applications Features and Benefits

DUGARD. Machine Tools Since Dugard 400 Slant Bed High Precision CNC Lathe.

Dual Path Mobile Pump

CILINDRI SENZA STELO RODLESS CYLINDERS

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

ZF W325 Vertical offset, direct mount marine transmission.

DUAL FUEL BURNERS GAS/HEAVY OIL

Profile rail guides LLR

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

ZF W320 Vertical offset, direct mount marine transmission.

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Automatic Back-Flushing Filter AutoFilt RF9.

3516 Industrial Engine

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

912. The engine for construction equipment.

The Axial Flow Valve. Class 300/ SERIES

Transcription:

GO SILENTLY AT HIGH PRESSURE & HIGH SPEED INDUSTRIAL CONTINUUM Series Helical rotor pumps for high pressure and no noise application MOBILE The new generation of gear pumps for NO PULSATION & NO NOISE MARINE www.settima.it 1

Continuum pump / pompa Continuum Achieves better efficiency, lower production cost, better life quality for the industrial world. Ottiene alti livelli di efficienza, ridotti costi di produzione ed una migliore qualità del lavoro. Reducing noise in the workplace has become a necessity for many companies. By now most companies have recognized noise as a cost weighting on the economics of their businesses. Noise pollution remains a serious problem to be solved for both stationary and mobile machinery. Hydraulic pumps, above all those for high pressure, entail unacceptable noise and/or vibration levels in many different applications. Up to now the noise problem has always been approached in the only possible way: with secondary and expensive activities such as using pulsation dampers, hoses, damping rails and rings, encapsulating the hydraulic components or the entire system and so on. SETTIMA decided to start to design a new gear pumps generation capable to reduce as much as possible the acoustic emissions and the consequent vibration level. Some years ago the result was the Continuum pump series, able to reduce down to 52 db(a) the normal operation noise. Today SETTIMA presents the new generation of Continuum pumps, silent as always, but much more efficient and with longer lifetime even at heavy duty, at all pressure and speed ranges. The most important economic benefits of using Continuum pumps are: very low pump pulsations reduce dramatically also vibrations with no dispersion of energy, saving money respect to the more expensive traditional pumps such as piston pumps and internal gear pumps, high volumetric efficiency, also at very low speed, contributes to cost reduction and also enables the pump to be driven by motor at a variable velocity with consequent energy saving, cost saving by eliminating second noise reduction measures, keeping the same external dimensions of gear pump, with no necessity to redesign the system in case of replacement. COMPETITIVE ANALYSIS / ANALISI COMPETITIVA Continuum pump is a valid alternative to silently replace different traditional solutions of noisy high pressure pump. Continuum pump can replace the following types of high pressure pumps: External gear pumps Internal gear pumps Fixed displacement vane pumps Fixed displacement piston pumps Please contact Settima for all information about any possible replacement. ORIGIN OF NOISE AND VIBRATIONS KNOCKED DOWN BY CONTINUUM PUMP / LA POMPA CONTINU- UM HA ELIMINATO LE ORIGINI DEL RUMORE E DELLE VIBRAZIONI The typical sound emissions of gear pumps have two distinct origins: mechanical noise and hydraulic noise. The mechanical noise is what can be expected from any pair of gears. The hydraulic noise, however, is generated by the perturbations of fluid pressure through the pump. This noise and/or vibration comes from three basic components: cavitation, that can cause serious noise in addition to structural damage to mechanical components the peak pressure that arises from trapping of fluid between the top and the bottom of the tooth, the ripple or the flow pulsation during meshing that causes pressure pulsation. The continuous contact helical rotor Continuum pump has solved these problems with sophisticated and efficient systems. THINK DIFFERENT: THE SILENT AND UNIQUE REVOLUTION OF CONTINUUM PUMP / UNA RIVOLUZIONE SILENZIOSA: LA POMPA CONTINUUM As for classic gear pumps, the transport flow is perpendicular to the axes, but the rotors profile, specially developed and internationally patented, does not trap any volume since the helical design of the profile plays the role of completing an overlap, making a gentle transmission of fluid resulting in a dramatic reduction of pulsation. There is just a single point of contact between the profiles during rotation, which eliminates the pockets acting on the axial thrust washer and the noise associated with this problem. The Continuum core and its technological innovation is based on three patented breakthroughs: The rotor profile The screw step The inner force balancing. 2

MANUFACTURING ACCURACY IN ANY DE- TAILS / MASSIMA ACCURATEZZA NEI DETTAGLI SETTIMA produces hydraulic no noise pumps since over thirty years, achieving a high level of competence and accuracy in the manufacture of high-precision hydraulic pump drives. Together with top production machineries, efficient test environments, 3D drawing capability and special materials for rotors and bushings, SETTIMA constantly achieves products of high quality that is the industry standard. CONTINUUM PUMP ADVANTAGES / VANTAGGI DELLA POMPA CONTINUUM Low noise also at high speed (up to 6.5 RPM). Average of 15dB(A) less noisy than standard external gear pumps. Reduced noise level for the machine operator and surroundings. Cost saving by eliminating second noise reduction measures. Easy to replace - compatibile with all external gear pumps. Helps meet legal noise requirements. Continuous variable flow rate (% to 1%). Intermittent operation at high pressure & low speed. High volumetrical efficiency. PULSATIONS LEVEL GRAPH / GRAFICO PULSAZIONI (1 bar - 4 cst - 1.5 rpm),4,3 Continuum External silence gear Internal gear Relative pressure pulsation (bar),2,1 -,1 -,2 -,3,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9 9,5 -,4 Time (msec) NOISE LEVEL GRAPH / GRAFICO EMISSIONI ACUSTICHE (15 bar) GR 28 GR 33-38 External Gear External Gear Continuum Continuum GR 47-55 GR 72 External Gear External Gear Continuum Continuum 3 3

Pump displacements / Cilindrate Group 1 3 25 Rated (bar) 2 15 1 5 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 Displacement (cm3/rev) Group 2 3 25 Rated (bar) 2 15 1 5 1 15 2 25 3 Displacement (cm3/rev) Group 3 3 25 Rated (bar) 2 15 1 5 2 24 28 32 36 4 44 48 52 56 6 64 68 72 76 8 84 88 92 96 1 Displacement (cm3/rev) Group 4 3 25 Rated (bar) 2 15 1 5 8 86 92 98 14 11 116 122 128 134 14 146 152 158 164 17 176 182 188 194 2 Displacement (cm3/rev) 4

Applications / Applicazioni INDUSTRIAL MOBILE ENVIRONMENTAL INDUSTRY MARINE Machine tools lubrication systems. Lifting equipment, hydraulic systems for dock-levelers. Hydraulic transmission systems. Machines lubrication. Chemical metering. Hydraulic systems for injection moulding machines, presses, compactors and balers. Systems for lubrication and cooling of gearboxes and bearings. Hydraulic powerpack. equip- Ground-handling ment. Agricultural machinery. Hydraulic systems for parking systems. Steering units. Torque converters & powershift transmissions. Street-sweeping vehicles. Shredder systems. Waste container level lifter. Baler and compacting of waste. Containers. Hooklift containers. Back loading containers. Front loading containers. Liftdumper containers. Hooklift systems. Garbage trucks. Mobile compactors. Stationary compactors. Marine power hydraulics. Rudder actuators (tandem system). Propeller pitch control. Propeller drive (power transmission from engine). Rotary vane steering gears. Minipowerpacks (dock operation, door control). Yacht building industry (lifting systems: fly bridge cranes, tenderlift, elevator, walkways, automatic swimming ladders, side boarding ladders, pitch controls and operations, hydraulic davits). Hydro power. Feeder system for filter circuits, cooling circuits, lubrication applications, pump transfer unit. Technical characteristics / Caratteristiche tecniche SPECIAL HELICAL ROTORS CONTINUUM represents an innovative and revolutionary gear pump. The patented profile of the Continuum rotors permits just a single point of contact between gears: this results, together with a particular screw step and inner force balancing, in the total absence of trapped and compressed oil, and leads to no noise and no pulsation. HIGH PRESSURE CONTINUUM has been designed for high pressure, high speed and heavy duty. TANDEM GROUP CONTINUUM can be also assembled as a double pump, connecting two pumps from different groups: from group 1 to group 4. 5

Technical characteristics Models / Modelli 28-33 -38-47 - 55-72 - 92* - 16* Flanges Flange Connections Connessioni Installation position Posizione di installazione Shaft rotation Rotazione Shaft speed Velocità di rotazione Flows Portate Group 1 Group 2 (European, German, BKT, SAE-A) Group 3 (European, SAE-B) Group 4 (SAE-D) Gruppo 1 Gruppo 2 (Europeo, Tedesco, BKT, SAE-A) Gruppo 3 (Europeo, SAE-B) Gruppo 4 (SAE-D) BSPP (GAS) SAE 3/6 PSI FL 4 HOLES M6 SU Ø4 DN2 (mentioned connections depend on model) BSPP (GAS) SAE 3/6 PSI FL 4 HOLES M6 SU Ø4 DN2 (in base al modello) External and/or under oil Esterna e/o immersa Clockwise (please contact Settima for counter clockwise) Destra (contattare Settima per sinistra) From 15 to 6.5 rpm (for usage below 1. rpm or over 1.8 rpm please contact Settima) Da 15 a 6.5 rpm (per utilizzi a giri inferiori a 1. rpm o superiori a 1.8 rpm contattare Settima) From 4 up to 22 cm3 from 6L/min up to 33L/min (at 1.5 rpm) Da 4 fino a 22 cm3 da 6L/min fino a 33L/min (a 1.5 rpm) Operating pressure operativa Max. Continuous: 275 bar Max. Cycle ON/OFF: 28 bar Max. Peak: 3 bar Depending on models Depending on models Depending on models Max. Continuo: 275 bar Max. Ciclo ON/OFF: 28 bar Max. Picco: 3 bar In base al modello In base al modello In base al modello Inlet pressure di aspirazione.8 3 bar (depends on models),8 3 bar (in base al modello) Fluids Fluidi - Mineral oil - Synthetic oil - Olio minerale - Olio sintetico Viscosity Viscosità Environmental temperature Temperatura ambiente Oil temperature Temperature olio Possible: from 5 up to 8 cst** Recommended: from 32 up to 15 cst Starting condition: up to 3. cst** From -15 C up to +6 C Da -15 C a +6 C From -15 C up to +8 C*** Da -15 C a +8 C*** Consentita: da 5 fino a 8 cst** Raccomandata: da 32 fino a 15 cst Condizioni di avviamento: fino a 3. cst** Contamination level Livello di contaminazione Filtration Filtrazione Seals Guarnizioni Acoustic emissions Emissioni acustiche Flanges material Materiale delle flange Pump body / Corpo Screws / Viti Up to 8 NAS (18/17/14 ISO446) (for heavy duty operations over 15 bar, over 4 working hours/day, 1 cycle/day oil ISO 46) Fino a 8 NAS (18/17/14 ISO446) (per lavoro ad alto sforzo oltre 15 bar, oltre 4 ore lavorative/giorno, 1 cicli/ giorno olio ISO 46) From 25 to 1 µm (for heavy duty operations over 15 bar, over 4 working hours/day, 1 cycle/day oil ISO 46) Da 25 a 1 µm (per lavoro ad alto sforzo oltre 15 bar, oltre 4 ore lavorative/giorno, 1 cicli/giorno olio ISO 46) NBR, FKM (others on request) NBR, FKM (altri a richiesta) From 52 up to 63 db(a) at 2.95 rpm Da 52 fino a 63 db(a) at 2.95 rpm Cast iron Ghisa Extruded aluminium alloy / Alluminio estruso Hardened steel / Acciaio temprato * Model GR92 and GR16 will be available soon. I modelli GR92 e GR16 saranno disponibili a breve. ** Please for more information about possible and starting conditions of viscosity contact Settima. Contattare Settima per maggiori informazioni sui livelli di viscosità possibili e quelli delle condizioni di inizio lavoro. *** For higher temperature than 5 C, please, contact Settima. Per temperature superiori a 5 C, contattare Settima. 6

System requirements / Requisiti del sistema Inlet pressure The inlet vacuum must be controlled within the prescribed range in order to achieve the expected pump life and performance. The system design must meet inlet pressure requirements during all modes of operation. Peak pressure is the highest intermittent pressure allowed. The reaction time of the pressure relief valve determines the duration of operation at pressure above the rated value. The maximum time interval is 1 ms. The illustration to the right shows peak pressure in relation to rated pressure and reaction time (1 ms maximum). Rated pressure is the average, regularly occurring, operating pressure that does not compromise the product's life and performance. System pressure is the pressure differential between the outlet and inlet ports. System pressure must remain at, or below, the rated pressure during normal operation to achieve expected life. Max. continuous vacuum.8 [23.6] bar abs. Max. intermittent vacuum.6 [17.7] [in. Hg] Max. pressure 3. [88.5] Time versus pressure Peak pressure Rated pressure Reaction time (1 ms max) Time Hydraulic fluids Ratings and data for Continuum pumps are valid for operation with premium hydraulic fluids containing oxidation, rust, and foam inhibitors. These fluids must possess good thermal and hydrolytic stability to prevent wear, erosion, and corrosion of internal components. They include: Hydraulic fluids following DIN 51524, part 2 (HLP) and part 3 (HVLP) specifications API CD engine oils conforming to SAE J183 M2C33F or G automatic transmission fluids Certain agricultural tractor fluids Use only clean fluid in the pump and hydraulic circuit. Never mix hydraulic fluids. 7

Temperature and viscosity Temperature and viscosity requirements must be concurrently satisfied. Use petroleum / mineral-based fluids. High temperature limits apply at the inlet port to the pump. The pump should run at or below the maximum continuous temperature. The peak temperature is based on material properties. Don t exceed it. Cold oil, generally, doesn t affect the durability of pump components. It may affect the ability of oil to flow and transmit power. For this reason, keep the temperature at 16 C [6 F] above the pour point of the hydraulic fluid. Minimum (cold start) temperature relates to the physical properties of component materials. Minimum viscosity occurs only during brief occasions of maximum ambient temperature and severe duty cycle operation. You will encounter maximum viscosity only at cold start. During this condition, limit speeds until the system warms up. Size heat exchangers to keep the fluid within these limits. Test regularly to verify that these temperatures and viscosity limits aren t exceeded. For maximum unit efficiency and bearing life, keep the fluid viscosity in the recommended viscosity range. Fluid viscosity Maximum (cold start) 3 [1394] mm 2 /s Recommended range 32-15** [148-695] [SUS] Minimum 5 [23] Temperature Minimum (cold start) -15 [-4] C Maximum continuous 5* [122] [ F] Peak (intermittent) 9* [176] *For higher temperature than 5 C, please contact Settima. **For viscosity value out of this range, please contact Settima. Filtration Filters A Class 18/17/14 of ISO 446 (or better) filter must be used. Selecting a filter When selecting a filter, please consider: Contaminant ingression rate (determined by factors such as the number of actuators used in the system) Generation of contaminants in the system Required fluid cleanliness Desired maintenance interval Filtration requirements of other system components Measure filter efficiency with a Beta ratio (β x ). For: Suction filtration, with controlled reservoir ingression, use a β 35-45 = 75 filter Return or pressure filtration, use a pressure filtration with an efficiency of β 1 = 75. βx ratio is a measure of filter efficiency defined by ISO 4572. It is the ratio of the number of particles greater than a given diameter ( x in microns) upstream of the filter to the number of these particles downstream of the filter. Fluid cleanliness level and βx ratio Fluid cleanliness level (per ISO 446) Class 18/17/14 or better β x ratio (suction filtration) β 35-45 = 75 and β 1 = 2 β x ratio (pressure or return filtration) β 1 = 75 Recommended inlet screen size 1-125 µm [.4-.5 in] The filtration requirements for each system are unique. Evaluate filtration system capacity by monitoring and testing prototypes. 8

Reservoir The reservoir provides clean fluid, dissipates heat, removes entrained air and makes up for changes in fluid volume due to fluid expansion-contraction and flow imbalances associated with differential cylinders. A correctly sized reservoir accommodates maximum volume changes during all system operating modes. It promotes de-aeration of the fluid as it passes through, and accommodates a fluid dwell-time between 6 and 18 seconds, allowing entrained air to escape. Hydraulic oil contains 1% of dissolved air by volume in normal conditions and the system should be design in order to avoid any over-areation of the hydraulic fluid, to limit any air release at the inlet port. Minimum reservoir capacity depends on the volume required to cool and hold the oil from all retracted cylinders, allowing for expansion due to temperature changes. A fluid volume of 1 to 3 times the pump output flow (per minute) is satisfactory. The minimum reservoir capacity is 125% of the fluid volume. The suction line shall be installed above the bottom of the reservoir to take advantage of gravity separation and prevent large foreign particles from entering the line. Cover the line with a 1-125 micron screen. The pump should be below the lowest expected fluid level. Put the return-line below the lowest expected fluid level to allow discharge into the reservoir for maximum dwell and efficient deaeration. A baffle (or baffles) between the return and suction lines promotes deaeration and reduces fluid surges. 9

Pump drive Shaft options for Continuum pumps include tapered, tang, splined, or parallel shafts. They are suitable for a wide range of direct and indirect drive applications for radial and thrust loads. Plug-in drives, acceptable only with a splined shaft, can impose severe radial loads when the mating spline is rigidly supported. Increasing spline clearance does not alleviate this condition. Use plug-in drives if the concentricity between the mating spline and pilot diameter is within.1 mm [.4 in]. Lubricate the drive by flooding it with oil. A 3-piece coupling minimizes radial or thrust shaft loads. In order to avoid spline shaft damages it is recommended to use carburized and hardened steel couplings with 6-62 HRC surface hardness. Allowable radial shaft loads are a function of the load position, load orientation, and operating pressure of the hydraulic pump. All external shaft loads have an effect on bearing life, and may affect pump performance. In applications where external shaft loads can t be avoided, minimize the impact on the pump by optimizing the orientation and magnitude of the load. Use a tapered input shaft; don t use splined shafts for belt or gear drive applications. A spring-loaded belt tension-device is recommended for belt drive applications to avoid excessive tension. Avoid thrust loads in either direction. Contact Settima if continuously applied external radial or thrust loads occur. Pump life Pump life is a function of speed, system pressure, and other system parameters (such as fluid quality and cleanliness). All Continuum pumps use hydrodynamic journal bearings that have an oil film maintained between the gear/shaft and bearing surfaces at all times. If the oil film is sufficiently sustained through proper system maintenance and operating within recommended limits, long life can be expected. B1 life expectancy number is generally associated with rolling element bearings. It does not exist for hydrodynamic bearings. High pressure, resulting from high loads, impacts pump life. When submitting an application for review, provide machine duty cycle data that includes percentages of time at various loads and speeds. We strongly recommend a prototype testing program to verify operating parameters and their impact on life expectancy before finalizing any system design. 1

Pump drive data form Fill out this page and send the complete form to your Settima representative for an assistance in applying pumps with belt or gear drive. This illustration shows a pump with counterclockwise orientation: Optimal radial load position 9 o 9 o α a Inlet port 18 o o o 18 o Inlet port 27 o 27 o P a a dw dw Application data Item Value Unit Pump displacement cm 3 /rev [in 3 /rev] Rated system pressure Relief valve setting bar psi Pump shaft rotation left right Pump minimum speed Pump maximum speed min -1 (rpm) Drive gear helix angle (gear drive only) degree Belt type (gear drive only) V notch Belt tension (gear drive only) P N lbf Angular orientation of gear or belt to inlet port α degree Distance from flange to center of gear or pulley a mm in Pitch diameter of gear or pulley d w 11

Product description / Descrizione prodotto 16 4 6 17 13 1 9 12 8 15 6 11 1 5 2 17 14 7 15 3 N DESCRIPTION/DESCRIZIONE MATERIAL / MATERIALE 1 O-ring seal / O-ring NBR 2 O-ring seal / O-ring NBR 3 O-ring seal / O-ring NBR 4 Driving Continuum rotor / Rotore guida Continuum Hardened steel / Acciaio temprato 5 Motor flange / Flangia motore Cast iron / Ghisa 6 Ring for bush / Anello porta boccola Bronze / Bronzo 7 Driven Continuum rotor / Rotore guidato Continuum Hardened steel / Acciaio temprato 8 Body / Corpo Extruded aluminum alloy / Alluminio estruso 9 Cover flange / Flangia Cast iron / Ghisa 1 Seal / Anello di tenuta NBR 11 Seeger / Seeger Steel / Acciaio 12 Screws / Viti di fissaggio Steel / Acciaio 13 Piston / Pistone Steel / Acciaio 14 Piston / Pistone Steel / Acciaio 15 Centring Keys / Spine di centraggio Steel / Acciaio 17 Bushings / Bronzine Steel with PTFE coating / Acciaio con rivestimento PTFE Standard type and options STANDARD OPTIONS Pump Body Alluminium Cast iron Seal kit NBR FKM 12

Ordering code / Codice ordine Single pump / Pompa singola Type Class Classe Displacement Cilindrata Flange & shaft Flangia & albero Ports Porte Shaft seal Guarnizione albero Rotation Rotazione GR28 2V 4-6-8-1-13 F1AC3-F1PAC2-F1KAG54-F1LAGL54- FSAEAAC-F1KAGL54 G-U GR33 2V 1-13-15-18 F2AC4-F2BK7AG-FSAEAAC-FSAEAAT9 G-Q-M-U GR38 2V 16-18-2-22-25-28 F2AC4-F2BK7AG-FSAEAAC- FSAEAAT11-FSAEAAT9 G-Q-M-U GR47 2V 28-32-36-4-45-5 F3AC9-FSAEBAC-FSAEBAT13 O-U GR55 2V 5-63-75-9 FSAEBAC-FSAEBAT15 O-OE GR72 2V 94-11-125-15-175-2-22 FSAEDAC-FSAEDAT23 ME Standard NBR (none) Optional FKM V Standard DX (none) Optional SX* * Please Contact Settima for SX counter clockwise optional rotation. Contattare Settima per rotazione SX opzionale. DIRECTION OF ROTATION / SENSO DI ROTAZIONE Continuum pumps are available with right rotation as standard configuration and left rotation as optional configuration. Right hand rotation means that, when standing in front of the pump, with driving shaft towards to the observer, the pump is rotating clockwise (DX). The other way around with left hand rotation, counter clockwise (SX). Le pompe Continuum sono fornite con la configurazione standard di rotazione destra. Opzionale la rotazione sinistra. Con rotazione destra (DX) si intende che, guardando la pompa frontalmente, con l albero conduttore sporgente verso il punto di osservazione, la rotazione sarà in senso orario, con il lato mandata sulla destra e il lato aspirazione sulla sinistra della pompa. Viceversa per quanto riguarda la rotazione sinistra (SX). Continuum pumps, despite the type of configuration, can rotate to the opposite side if the pressure is not higher than 1% of maximum continuous pressure (check the Technical Characteristics table). Le pompe Continuum, qualunque configurazione di rotazione abbiano, possono ruotare in senso inverso a pressioni non superiore al 1% della massima pressione continua (verificare nella tabella delle caratteristiche tecniche). DX: Clockwise rotation / Rotazione destra SX: Counter clockwise rotation / Rotazione sinistra Inlet / Aspirazione Outlet / Mandata Outlet / Mandata Inlet / Aspirazione 13

Variant codes for ordering integral relief valves* The tables below detail the various codes for ordering integral relief valves. R: Code C E F G K I L M N O Pump speed for RV setting 5 min -1 (rpm) 1 min -1 (rpm) 125 min -1 (rpm) 15 min -1 (rpm) 2 min -1 (rpm) 225 min -1 (rpm) 25 min -1 (rpm) 28 min -1 (rpm) 3 min -1 (rpm) 325 min -1 (rpm) Code setting 18 18 bar [261 psi] 3 3 bar [435 psi] 4 4 bar [58 psi] 5 5 bar [725 psi] 6 6 bar [87 psi] 7 7 bar [115 psi] 8 8 bar [116 psi] 9 9 bar [135 psi] 1 1 bar [145 psi] 12 12 bar [174 psi] 14 14 bar [23 psi] 16 16 bar [232 psi] 18 18 bar [2611 psi] 21 21 bar [346 psi] 25 25 bar [3626 psi] Integral relief valve schematic * Please, contact Settima for this option. 14

GR28 - Dimensional drawings / Disegni dimensionali GR28 SHAFT AND FLANGE TYPE AND DIMENSIONS / TIPO ALBERO E FLANGE E DIMENSIONI Group 1 pumps / Pompe gruppo 1 Available flanges and shafts / Flange ed alberi disponibili Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR28 - TYPE / TIPO 1-C3 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 11, 44,5 275 28 3 55 6 6,4 9,2 16,5 47,25 275 28 3 55 8 8,3 12, 111,5 49,75 246 26 28 55 1 1,2 14,7 116,5 52,25 222 25 27 55 13 12,9 18,6 123,4 55,55 176 23 25 55 Max torque / Coppia max: 1 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 15

Type CC L/min Dimensions A Dimensioni A GR28 - TYPE / TIPO 1-C3 (with safety valve/con valvola di massima) Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 114,1 44,5 275 28 3 55 6 6,4 9,2 119,5 47,25 275 28 3 55 8 8,3 12, 124,5 49,75 246 26 28 55 1 1,2 14,7 129,5 52,25 222 25 27 55 13 12,9 18,6 136,4 55,7 176 23 25 55 Max torque / Coppia max: 1 Nm Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR28 - TYPE / TIPO 1P-C2 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 11, 44,5 24 26 28 55 6 6,4 9,2 16,5 47,25 23 24 27 55 8 8,3 12, 111,5 49,75 2 21 22 55 1 1,2 14,7 116,5 52,25 16 17 18 55 13 12,9 18,6 123,4 55,7 14 15 16 55 Max torque / Coppia max: 5 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 16

Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR28 - TYPE / TIPO 1K-G54 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 11, 44,5 275 28 3 55 6 6,4 9,2 16,5 47,25 23 24 27 55 8 8,3 12, 111,5 49,75 18 2 21 55 1 1,2 14,7 116,5 52,25 15 16 17 55 13 12,9 18,6 123,4 55,7 12 13 14 55 Max torque / Coppia max: 4 Nm Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR28 - TYPE / TIPO 1K-GL54 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 11, 44,5 275 28 3 55 6 6,4 9,2 16,5 47,25 26 275 29 55 8 8,3 12, 111,5 49,75 23 24 25 55 1 1,2 14,7 116,5 52,25 18 19 2 55 13 12,9 18,6 123,4 55,7 15 16 17 55 Max torque / Coppia max: 5 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 17

Type CC L/min Dimensions A Dimensioni A GR28 - TYPE / TIPO 1K-GL54 (with safety valve / con valvola di massima) Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 114, 44,5 275 28 3 55 6 6,4 9,2 119,5 47,25 26 275 29 55 8 8,3 12, 124,5 49,75 23 24 25 55 1 1,2 14,7 129,5 52,25 18 19 2 55 13 12,9 18,6 136,4 55,7 15 16 17 55 Max torque / Coppia max: 5 Nm Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR28 - TYPE / TIPO SAEA-A - AC Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 17, 5,5 234 238 255 55 6 6,4 9,2 112,5 53,25 234 238 255 55 8 8,3 12, 117,5 55,75 29 221 238 55 1 1,2 14,7 122,5 58,25 189 213 23 55 13 12,9 18,6 129,4 61,7 17 196 213 55 Max torque / Coppia max: 6 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 18

Type CC L/min Dimensions A Dimensioni A GR28 - TYPE / TIPO SAEA-A - AC (with safety valve/con valvola di massima) Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 12, 5,5 234 238 255 55 6 6,4 9,2 125,5 53,25 234 238 255 55 8 8,3 12, 13,5 55,75 29 221 238 55 1 1,2 14,7 135,5 58,25 189 213 23 55 13 12,9 18,6 142,4 61,7 17 196 213 55 Max torque / Coppia max: 6 Nm Type CC L/min Dimensions A Dimensioni A GR28 - TYPE / TIPO SAE A-A SAE O-RING PORT 3/4 14 UNF 2B Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 17, 5,5 234 238 255 55 6 6,4 9,2 112,5 53,25 234 238 255 55 8 8,3 12, 117,5 55,75 29 221 238 55 1 1,2 14,7 122,5 58,25 189 213 23 55 13 12,9 18,6 129,4 61,7 17 196 213 55 Max torque / Coppia max: 6 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 19

Type CC L/min Dimensions A Dimensioni A GR28 - TYPE / TIPO 1L-GL54 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 11, 275 28 3 55 6 6,4 9,2 16,5 26 275 29 55 8 8,3 12, 111,5 23 24 25 55 1 1,2 14,7 116,5 18 19 2 55 13 12,9 18,6 123,4 15 16 17 55 Max torque / Coppia max: 5 Nm Type CC L/min Dimensions A Dimensioni A GR28 - TYPE / TIPO 1L-G54 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 4 4,2 6, 11, 275 28 3 55 6 6,4 9,2 16,5 23 24 27 55 8 8,3 12, 111,5 18 2 21 55 1 1,2 14,7 116,5 15 16 17 55 13 12,9 18,6 123,4 12 13 14 55 Max torque / Coppia max: 4 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 2

GR33 - Dimensional drawings / Disegni dimensionali GR33 SHAFT AND FLANGE TYPE AND DIMENSIONS / TIPO ALBERO E FLANGE E DIMENSIONI Group 2 pumps / Pompe gruppo 2 Available flanges and shafts / Flange ed alberi disponibili Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR33 - TYPE / TIPO 2-C4 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 1 1,1 14,5 122,5 53,75 275 28 3 55 13 12,6 18,1 127,4 56,2 265 27 29 55 15 15,2 21,8 132,4 58,7 241 25 27 55 18 18,2 26,1 138,2 61,6 26 25 27 55 Max torque / Coppia max: 21 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 21

Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR33 - TYPE / TIPO 2BK7-AG Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 1 1,1 14,5 122,5 53,75 275 28 3 55 13 12,6 18,1 127,4 56,2 265 27 29 55 15 15,2 21,8 132,4 58,7 241 25 27 55 18 18,2 26,1 138,2 61,6 26 25 27 55 Max torque / Coppia max: 11 Nm Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR33 - TYPE / TIPO SAEA-AC Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 1 1,1 14,5 122,5 53,75 275 28 3 55 13 12,6 18,1 127,4 56,2 265 27 29 55 15 15,2 21,8 132,4 58,7 241 25 27 55 18 18,2 26,1 138,2 61,6 26 25 27 55 Max torque / Coppia max: 14 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 22

Type CC L/min Dimensions A Dimensioni A GR33 - TYPE / TIPO SAEA-AC SAE O-RING UNF Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 1 1,1 14,5 122,5 53,75 275 28 3 55 13 12,6 18,1 127,4 56,2 265 27 29 55 15 15,2 21,8 132,4 58,7 241 25 27 55 18 18,2 26,1 138,2 61,6 26 25 27 55 Max torque / Coppia max: 14 Nm Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR33 - TYPE / TIPO SAEA-T9 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 1 1,1 14,5 122,5 53,75 275 28 3 55 13 12,6 18,1 127,4 56,2 265 27 29 55 15 15,2 21,8 132,4 58,7 241 25 27 55 18 18,2 26,1 138,2 61,6 26 25 27 55 Max torque / Coppia max: 19 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 23

Type CC L/min Dimensions A Dimensioni A GR33 - TYPE / TIPO SAEA-T9 SAE O-RING UNF Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 1 1,1 14,5 122,5 53,75 275 28 3 55 13 12,6 18,1 127,4 56,2 265 27 29 55 15 15,2 21,8 132,4 58,7 241 25 27 55 18 18,2 26,1 138,2 61,6 26 25 27 55 Max torque / Coppia max: 19 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF INLET OUTLET PORTS / PORTE DI ASPIRAZIONE E MANDATA (Suction / ) Type G / G Type Q / Q Type M / M UNF INLET OUTLET PORTS / PORTE DI ASPIRAZIONE E MANDATA UNF - Type U / U SAE O-Ring Port 12 thread ANSI B1.1 1 1/16 UN-2B SAE O-Ring Port 16 thread ANSI B1.1 1 5/16 12 UN-2B Suction SAE O-Ring Port 1 thread ANSI B1.1 1 7/8 14 UNF-2B SAE O-Ring Port 12 thread ANSI B1.1 1 1/16 12 UN-2B Suction/ UNF ports possible configuration Possibili combinazioni porte di aspirazione/mandata di tipo UNF Pump Suction port port GR33-1 cc SAE O-Ring port 12 SAE O-Ring port 1 GR33-13 cc SAE O-Ring port 12 SAE O-Ring port 1 GR33-15 cc SAE O-Ring port 12 SAE O-Ring port 1 GR33-18 cc SAE O-Ring port 16 SAE O-Ring port 12 24

GR38 - Dimensional drawings / Disegni dimensionali GR38 SHAFT AND FLANGE TYPE AND DIMENSIONS / TIPO ALBERO E FLANGE E DIMENSIONI Available flanges and shafts / Flange ed alberi disponibili Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR38 - TYPE / TIPO 2-C4 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 16 15,9 22,8 126, 55,5 265 28 3 55 18 17,9 25,8 129, 57, 247 26 28 55 2 2, 28,8 132, 58,5 23 25 27 55 22 22,1 31,8 135, 6, 222 24 26 55 25 25,2 36,2 139,5 62,25 2 21 22 55 28 28,3 4,7 144, 64,5 18 19 2 55 Max torque / Coppia max: 21 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 25

GR38 - TYPE / TIPO 2BK7-AG Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 16 15,9 22,8 126, 55,5 265 28 3 55 18 17,9 25,8 129, 57, 247 26 28 55 2 2, 28,8 132, 58,5 23 25 26 55 22 22,1 31,8 135, 6, 21 23 24 55 25 25,2 36,2 139,5 62,25 2 21 22 55 28 28,3 4,7 144, 64,5 18 19 2 55 Max torque / Coppia max: 11 Nm GR38 - TYPE / TIPO SAEA-AC Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 16 15,9 22,8 126, 55,5 265 28 3 55 18 17,9 25,8 129, 57, 247 26 28 55 2 2, 28,8 132, 58,5 23 25 27 55 22 22,1 31,8 135, 6, 222 24 26 55 25 25,2 36,2 139,5 62,25 2 21 22 55 28 28,3 4,7 144, 64,5 18 19 2 55 Max torque / Coppia max: 14 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 26

Type CC L/min Dimensions A Dimensioni A GR38 - TYPE / TIPO SAEA-AC SAE O-RING PORT UNF Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 16 15,9 22,8 126, 55,5 265 28 3 55 18 17,9 25,8 129, 57, 247 26 28 55 2 2, 28,8 132, 58,5 23 25 27 55 22 22,1 31,8 135, 6, 222 24 26 55 25 25,2 36,2 139,5 62,25 2 21 22 55 28 28,3 4,7 144, 64,5 18 19 2 55 Max torque / Coppia max: 14 Nm Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR38 - TYPE / TIPO SAEA-T9 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 16 15,9 22,8 126, 55,5 265 28 3 55 18 17,9 25,8 129, 57, 247 26 28 55 2 2, 28,8 132, 58,5 23 25 27 55 22 22,1 31,8 135, 6, 222 24 26 55 25 25,2 36,2 139,5 62,25 2 21 22 55 28 28,3 4,7 144, 64,5 18 19 2 55 Max torque / Coppia max: 19 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 27

Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR38 - TYPE / TIPO SAEA-T11 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 16 15,9 22,8 126, 55,5 265 28 3 55 18 17,9 25,8 129, 57, 247 26 28 55 2 2, 28,8 132, 58,5 23 25 27 55 22 22,1 31,8 135, 6, 222 25 27 55 25 25,2 36,2 139,5 62,25 28 25 27 55 28 28,3 4,7 144, 64,5 197 25 27 55 Max torque / Coppia max: 21 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF INLET OUTLET PORTS / PORTE DI ASPIRAZIONE E MANDATA (Suction / ) Type G / G Type Q / Q Type M / M UNF INLET OUTLET PORTS / PORTE DI ASPIRAZIONE E MANDATA UNF - Type U / U SAE O-Ring Port 12 thread ANSI B1.1 1 1/16 UN-2B SAE O-Ring Port 16 thread ANSI B1.1 1 5/16 12 UN-2B Suction/ UNF ports possible configuration Possibili combinazioni porte di aspirazione/mandata di tipo UNF Pump Suction port port Suction SAE O-Ring Port 1 thread ANSI B1.1 1 7/8 14 UNF-2B SAE O-Ring Port 12 thread ANSI B1.1 1 1/16 12 UN-2B GR38-16 cc SAE O-Ring port 12 SAE O-Ring port 1 GR38-18 cc SAE O-Ring port 16 SAE O-Ring port 12 GR38-2 cc SAE O-Ring port 16 SAE O-Ring port 12 GR38-22 cc SAE O-Ring port 16 SAE O-Ring port 12 GR38-25 cc SAE O-Ring port 16 SAE O-Ring port 12 GR38-28 cc SAE O-Ring port 16 SAE O-Ring port 12 GR38-5 cc SAE O-Ring port 16 SAE O-Ring port 12 28

GR47 - Dimensional drawings / Disegni dimensionali GR47 SHAFT AND FLANGE TYPE AND DIMENSIONS / TIPO ALBERO E FLANGE E DIMENSIONI Group 3 pumps / Pompe gruppo 3 Available flanges and shafts / Flange ed alberi disponibili Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR47 - TYPE / TIPO 3-C9 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 28 28, 4,3 151,5 67,5 27 28 3 57 32 32,2 46,3 155,5 69,5 252 27 28 57 36 36,3 52,3 159,5 71,5 239 25 27 57 4 4,5 58,3 163,5 73,5 225 25 27 57 45 45,5 65, 168, 75,75 213 25 27 57 5 5,3 72,4 173, 78,25 22 25 27 57 Max torque / Coppia max: 32 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 29

2 6 11,6 -.5 Type CC L/min Dimensions A Dimensioni A GR47 - TYPE / TIPO SAEB-AC / SAEB-T13 Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 28 28, 4,3 151,5 67,5 27 28 3 57 32 32,2 46,3 155,5 69,5 252 27 28 57 36 36,3 52,3 159,5 71,5 239 25 27 57 4 4,5 58,3 163,5 73,5 225 25 27 57 45 45,5 65, 168, 75,75 213 25 27 57 5 5,3 72,4 173, 78,25 22 25 27 57 Max torque / Coppia max: 45 Nm - Max torque / Coppia max: 6 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF GR47 INLET OUTLET PORTS / PORTE DI ASPIRAZIONE E MANDATA Inlet Type O / O Outlet SAE SAE 3 1 ¼ Ø 43,5 45 15 Type U / U SAE 3 ¾ Ø 35,5 45 15 UNF 19 23 19 23 SAE O-Ring Port UNF SAE 2 SAE O-Ring Port UNF SAE 16 3

GR55 - Dimensional drawings / Disegni dimensionali GR55 SHAFT AND FLANGE TYPE AND DIMENSIONS / TIPO ALBERO E FLANGE E DIMENSIONI Available flanges and shafts / Flange ed alberi disponibili 2 6 11,6 -.5 Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR55 - TYPE / TIPO SAEB-AC Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 5 5,5 72,7 179,5 81,5 275 28 3 57 63 63,5 91,4 188,5 86, 249 26 28 57 75 75, 18,1 196,5 9, 229 25 27 57 9 9,9 13,9 27,5 95,5 178 24 26 57 * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF Max torque / Coppia max: 55 Nm 31

2 6 11,6 -.5 Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B (**) GR55 - TYPE / TIPO SAEB-T15 Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 5 5,5 72,7 179,5 81,5 275 28 3 57 63 63,5 91,4 188,5 86, 249 26 28 57 75 75, 18,1 196,5 9, 229 25 27 57 9 9,9 13,9 27,5 95,5 178 24 26 57 Max torque / Coppia max: 7 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF ** Ask SETTIMA the dimensional drawings for OE suction port GR55 INLET OUTLET PORTS / PORTE DI ASPIRAZIONE E MANDATA - Type OE / OE INLET Type port O OE Size port SAE-3 1 ¼ SAE-3 1 ¼ only for 5cc SAE-3 1 ½ A1 3,2 3,2 35,7 B1 58,7 58,7 69,85 ØD1 33, 33, 38, F1 M1x2 M1x18 M12x18 OUTLET Type port O OE Size port SAE-3 ¾ SAE-3 1 A2 22,2 26,2 B2 47,6 52,4 ØD2 19, 25, F2 M1X18 M1X18 32

GR72 - Dimensional drawings / Disegni dimensionali GR72 SHAFT AND FLANGE TYPE AND DIMENSIONS / TIPO ALBERO E FLANGE E DIMENSIONI Group 4 pumps / Pompe gruppo 4 Available flanges and shafts / Flange ed alberi disponibili Type CC L/min Dimensions A Dimensioni A Dimensions B Dimensioni B GR72 - TYPE / TIPO SAED-AC Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 94 94,1 136 245, 125,65 24 25 26 57 11 11,4 147 248, 127,5 23 24 25 57 125 125,5 181 258, 132,15 22 22 23 57 15 15,9 218 268,5 137,4 2 21 22 57 175 175, 253 278,5 142,4 18 19 2 57 2 2,4 29 289, 147,65 16 17 18 57 Max torque / Coppia max: 1 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF 33

Type CC L/min Dimensions A Dimensioni A GR72 - TYPE / TIPO SAED-T23 Dimensions B Dimensioni B Continuous continua Intermittent intermittente (*) Peak pressure Picco pressione (*) Noise level Livello rumore 94 94,1 136 245, 125,5 24 25 26 57 11 11,4 147 248, 127, 23 24 25 57 125 125,5 181 258, 132, 22 22 23 57 15 15,9 218 268,5 137,25 2 21 22 57 175 175, 253 278,5 142,25 18 19 2 57 2 2,4 29 289, 147,5 16 17 18 57 Max torque / Coppia max: 12 Nm * Intermittent: cycle 2 sec. ON & 3 sec. OFF - Peak: cycle 1 sec. ON & 3 sec OFF. Intermittente: ciclo 2 sec. ON & 3 sec. OFF - Picco: ciclo 1 sec. ON & 3 sec OFF GR72 INLET OUTLET PORTS / PORTE DI ASPIRAZIONE E MANDATA - Type ME / ME SAE 3 2 ½ SAE 6 1 ½ Inlet Outlet 34

Flow performances @ 46 cst 5 GR 28 1P C2 GR28 1-C3 / 1L-GL54 / 1L-G54 5 GR28 1P-C2 GR 28 1P C2 45 45 4 4 35 35 Flow [L/min] 3 25 2 13cc (14bar) 1cc (18bar) 8cc (22bar) 6cc (24bar) Flow [L/min] 3 25 2 13cc (14bar) 1cc (18bar) 8cc (22bar) 6cc (24bar) 15 4cc (24bar) 15 4cc (24bar) 1 1 5 5 5 1 15 2 25 3 35 4 Sha Speed [rpm] 5 1 15 2 25 3 35 4 Sha Speed [rpm] 5 GR 28 1P C2 GR28 1K-G54 / 1K-GL54 5 GR28 SAEA-AC GR 28 1P C2 45 45 4 4 35 35 Flow [L/min] 3 25 2 13cc (14bar) 1cc (18bar) 8cc (22bar) 6cc (24bar) Flow [L/min] 3 25 2 13cc (14bar) 1cc (18bar) 8cc (22bar) 6cc (24bar) 15 4cc (24bar) 15 4cc (24bar) 1 1 5 5 5 1 15 2 25 3 35 4 Sha Speed [rpm] 5 1 15 2 25 3 35 4 Sha Speed [rpm] 7 GR33 GR 33 1 GR38 GR 38 65 6 55 9 8 Flow [L/min] 5 45 4 35 3 25 2 15 1 5 5 1 15 2 25 3 35 4 Sha Speed [rpm] 18cc (26bar) 15cc (241bar) 13cc (265bar) 1cc (275bar) Flow [L/min] 7 6 5 4 3 2 1 5 1 15 2 25 3 35 4 Sha Speed [rpm] 28cc (197bar) 25cc (28bar) 22cc (222bar) 2cc (23bar) 18cc (247bar) 16cc (265bar) 1 GR38 SAEA-T9 GR 38 SAEA T9 18 GR47 GR 47 9 16 8 14 Flow [L/min] 7 6 5 4 3 2 2cc (23bar) 18cc (247bar) 16cc (265bar) Flow [L/min] 12 1 8 6 4 5cc (22bar) 45cc (213bar) 4cc (225bar) 36cc (239bar) 32cc (252bar) 28cc (27bar) 1 2 5 1 15 2 25 3 35 4 Sha Speed [rpm] 5 1 15 2 25 3 35 4 Sha Speed [rpm] 35

Flow performances @ 46 cst 3 GR55 GR 55 35 GR72 GR 72 25 3 25 Flow [L/min] 2 15 1 9cc (178bar) 75cc (229bar) 63cc (249bar) 5cc (275bar) Flow [L/min] 2 15 1 2cc (22bar) 175cc (213bar) 15cc (225bar) 125cc (239bar) 11cc (252bar) 94cc (27bar) 5 5 5 1 15 2 25 3 35 4 Sha Speed [rpm] 5 75 1 125 15 175 2 Sha Speed [rpm] Servo Continuum pump - Servopompa Continuum 36

Power-torque performances @ 46 cst GR28 4 CC Power [kw] 2 18 16 14 12 1 8 6 4 2 2 18 16 14 12 1 8 6 4 2 5 1 15 2 25 3 35 4 2 GR28 6 CC 3 3 GR28 8 CC 4 18 16 25 25 35 14 12 2 2 3 25 1 15 15 2 8 6 1 1 15 4 2 5 5 1 5 5 1 15 2 25 3 35 4 5 1 15 2 25 3 35 4 3 GR28 1 CC 5 4 GR28 13 CC 6 25 2 45 4 35 3 35 3 25 55 5 45 4 35 15 25 2 3 1 5 2 15 1 5 15 1 5 25 2 15 1 5 5 1 15 2 25 3 35 4 GR33 1 CC 5 5 5 1 15 2 25 3 35 4 GR33 13 CC 5 7 45 4 45 4 45 4 6 35 35 35 5 3 3 3 4 25 25 25 2 2 2 3 15 15 15 2 1 5 1 5 1 5 1 5 1 15 2 25 3 35 4 5 1 15 2 25 3 35 4 37

Power-torque performances @ 46 cst GR33 15 CC GR33 18 CC 5 7 6 9 45 4 6 5 8 7 35 5 4 6 3 25 2 4 3 3 5 4 15 2 2 3 1 5 1 1 2 1 5 1 15 2 25 3 35 4 5 1 15 2 25 3 35 4 GR38 16 CC GR38 18 CC 5 8 6 9 45 4 35 3 25 2 15 1 5 7 6 5 4 3 2 1 55 5 45 4 35 3 25 2 15 1 5 8 7 6 5 4 3 2 1 5 1 15 2 25 3 35 4 5 1 15 2 25 3 35 4 GR38 2 CC GR38 22 CC 6 1 7 12 55 45 5 4 9 8 7 6 5 1 8 35 6 4 3 5 6 25 4 3 2 15 1 5 3 2 1 2 1 4 2 5 1 15 2 25 3 35 4 GR38 25 CC 8 12 5 1 15 2 25 3 35 4 GR38 28 CC 9 14 7 6 5 1 8 8 7 6 5 12 1 8 4 6 4 6 3 2 4 3 2 4 1 2 1 2 5 1 15 2 25 3 35 4 5 1 15 2 25 3 35 4 38

Power-torque performances @ 46 cst GR47 28 CC 9 14 1 GR47 32 CC 16 8 7 6 5 12 1 8 9 8 7 6 5 14 12 1 8 4 3 2 6 4 4 3 2 6 4 1 2 1 2 5 1 15 2 25 3 35 4 GR47 36 CC 12 18 5 1 15 2 25 3 35 4 GR47 4 CC 14 2 11 1 9 8 16 14 12 12 1 18 16 14 7 6 5 1 8 8 6 12 1 8 4 3 2 1 6 4 2 4 2 6 4 2 5 1 15 2 25 3 35 4 GR47 45 CC 14 22 5 1 15 2 25 3 35 4 GR47 5 CC 16 24 12 2 18 14 22 2 1 8 6 4 16 14 12 1 8 6 12 1 8 6 4 18 16 14 12 1 8 6 2 4 2 2 4 2 5 1 15 2 25 3 35 4 5 1 15 2 25 3 35 4 GR55 5 CC 15 25 2 GR55 63 CC 3 125 2 175 15 25 1 15 125 2 75 1 15 5 1 75 1 25 5 5 25 5 5 1 15 2 25 3 35 4 5 1 15 2 25 3 35 4 39

Power-torque performances @ 46 cst 25 GR55 75 35 3 GR55 9 CC 45 225 2 175 3 25 275 25 225 2 4 35 3 15 125 1 75 5 25 2 15 1 5 175 15 125 1 75 5 25 25 2 15 1 5 5 1 15 2 25 3 35 4 GR72 94 CC 16 5 5 1 15 2 25 3 35 4 GR72 11 CC 18 55 14 12 1 8 6 4 2 45 4 35 3 25 2 15 1 5 5 16 45 14 4 12 35 1 3 8 25 2 6 15 4 1 2 5 5 1 15 2 25 5 1 15 2 25 2 GR72 125 CC 65 3 GR72 15 CC 8 18 16 14 12 1 8 6 4 2 6 55 5 45 4 35 3 25 2 15 1 5 25 2 5 15 4 3 1 2 5 1 7 6 5 1 15 2 25 5 1 15 2 25 GR72 175 CC GR72 2 CC 3 9 4 11 25 2 8 7 6 35 3 25 1 9 8 7 15 5 4 2 6 5 1 3 2 5 1 5 1 15 2 25 15 4 1 3 2 5 1 5 1 15 25 4

Tandem & multiple pumps / Pompe doppie e multiple Continuum pumps are suitable for multiple setups, whereby the drive shaft of the first pump is extended to a second and even a third Continuum pump. Each pump is connected to another by means of coupling. Each pump has its own suction port. Basically the technical specifications of single pumps apply also to multiple setups**. The maximum speed is determined by the highest pump speed rate in use. In case of multiple setup configurations, it is recommended to use the largest displacement for the first pump. The front pump may be equipped with different types of flange and shaft. Ordering code / Codice ordine Multiple setups / Pompe multiple Type Class Classe Displacement Cilindrata Flange & shaft Flangia & albero Ports Porte Type 2nd stage 2 stadio Displacement 2nd stage Cilindrata 2 stadio Ports Porte Shaft seal Guarnizione albero Rotation Rotazione DG28 2V 4-6-8-1-13 F1AC3 G-U GR28 G-M- DG33 2V 1-13-15-18 F2AC4 Q-U GR28 4-6-8-1-13 G-U GR33 1-13-15-18 G-M- GR38 16-18-2-22-25-28 Q-U DG38 DG47 2V 2V F2AC4 F3AC9 FSAEBAT13 16-18-2-22-25-28 28-32-36-4-45-5 G-M- Q-U O-U GR28 4-6-8-1-13 G-U GR33 1-13-15-18 G-M- GR38 16-18-2-22-25-28 Q-U GR28 4-6-8-1-13 G-U GR33 1-13-15-18 G-M- GR38 16-18-2-22-25-28 Q-U Standard NBR (none) Standard DX (none) GR47 28-32-36-4-45-5 O-U GR28 4-6-8-1-13 G-U GR33 1-13-15-18 G-M- Optional FKM V Optional SX* DG55 2V 5-63-75-9 FSAEBAT15 O-OE GR38 16-18-2-22-25-28 Q-U GR47 28-32-36-4-45-5 O-U GR55 5-63-75-9 O-OE DG72 2V 94-11-125-15-175-2-225 FSAEDAT23 ME GR47 28-32-36-4-45-5 O-U GR55 5-63-75-9 O-OE GR72 94-11-125-15-175-2 ME * Please contact Settima for SX counter clockwise optional rotation. Contattare Settima per rotazione SX opzionale. ** The minimum operating pressure recommended for the second stage is 3 bar. In case of lower pressure, please, contact Settima. Minima pressione di funzionamento consigliata per il secondo stadio 3 bar, al di sotto, contattare Settima. 41

GR28 - Group 1 tandem pumps* GR28 + GR28 2 4 6 8 1 13 A 191,5 - - - - B 44,5 - - - - 4 C 9,5 - - - - D 11,9 - - - - E 11,9 - - - - A 197, 22,5 - - - B 47,25 47,25 - - - 6 C 93,25 96, - - - D 11,9 11,9 - - - E 11,9 11,9 - - - A 22, 27,5 212,5 - - B 49,75 49,75 49,75 - - 1 8 C 95,75 98,5 11, - - 1 13 D 11,9 11,9 11,9 - - E 11,9 11,9 11,9 - - A 27, 212,5 217,5 222,5 - B 52,25 52,25 52,25 52,25 - C 98,25 11, 13,5 16, - D 11,9 11,9 11,9 11,9 - E 11,9 11,9 11,9 11,9 - A 214, 219,5 224,5 229,5 236,5 B 55,7 55,7 55,7 55,7 55,7 C 11,75 14,5 17, 19,5 113, D 11,9 11,9 11,9 11,9 11,9 E 11,9 11,9 11,9 11,9 11,9 Available flanges and shafts for GR28 Flange ed alberi disponibili per GR28 Type flange 1C3 / Flangia tipo 1 C3 Type shaft 1C3 / Albero tipo 1C3 Max torque / Coppia max: 1 Nm * Standard multiple pumps are delivered with both stages in fluid communication. When placing an order, it is necessary to specify if the two stages will handle different kinds of fluids or fluids coming from more than one reservoir. / Le pompe multiple sono consegnate con entrambi gli stadi in comunicazione di fluido. In fase di ordine, occorre specificare se la pompa multipla utilizza oli differenti sui diversi stadi o provenienti da più di un serbatoio. 42

GR33 & GR38 - Groups 2 tandem pumps* GR33 1 GR33 + GR28 1 13 15 18 2 4 6 8 1 13 A 216,5 222, 227, 232, 239, B 53,75 53,75 53,75 53,75 53,75 C 16,25 19, 111,5 114, 117,5 D 13,75 13,75 13,75 13,75 13,75 E 11,9 11,9 11,9 11,9 11,9 A 221,4 226,9 231,9 236,9 243,9 B 56,2 56,2 56,2 56,2 56,2 C 18,7 111,45 113,95 116,45 119,95 D 13,75 13,75 13,75 13,75 13,75 E 11,9 11,9 11,9 11,9 11,9 A 226,4 231,9 236,9 241,9 248,9 B 58,7 58,7 58,7 58,7 58,7 C 111,2 113,95 116,45 118,95 122,45 D 13,75 13,75 13,75 13,75 13,75 E 11,9 11,9 11,9 11,9 11,9 A 232,2 237,7 242,7 247,7 254,7 B 61,6 61,6 61,6 61,6 61,6 C 114,1 116,85 119,35 121,85 125,35 D 13,75 13,75 13,75 13,75 13,75 E 11,9 11,9 11,9 11,9 11,9 1 GR33 + GR33 1 2 1 13 15 18 A 236, - - - B 53,75 - - - C 113,5 - - - D 13,75 - - - E 13,75 - - - 43

GR33 + GR33 13 15 18 2 1 13 15 18 A 24,9 245,8 - - B 56,2 56,2 - - C 115,95 118,4 - - D 13,75 13,75 - - E 13,75 13,75 - - A 245,9 25,8 255,8 - B 58,7 58,7 58,7 - C 118,45 12,9 123,4 - D 13,75 13,75 13,75 - E 13,75 13,75 13,75 - A 251,7 256,6 261,6 267,4 B 61,6 61,6 61,6 61,6 C 121,35 123,8 126,3 129,2 D 13,75 13,75 13,75 13,75 E 13,75 13,75 13,75 13,75 Available flanges and shafts for GR33 Flange ed alberi disponibili per GR33 Type flange 2C4 Flangia tipo 2C4 Type shaft 2C4 Albero tipo 2C4 Max torque / Coppia max: 21 Nm * Standard multiple pumps are delivered with both stages in fluid communication. When placing an order, it is necessary to specify if the two stages will handle different kinds of fluids or fluids coming from more than one reservoir. / Le pompe multiple sono consegnate con entrambi gli stadi in comunicazione di fluido. In fase di ordine, occorre specificare se la pompa multipla utilizza oli differenti sui diversi stadi o provenienti da più di un serbatoio. 44

GR38 1 GR38 + GR28 16 18 2 22 25 28 2 4 6 8 1 13 A 191,5 228,5 233,5 238,5 245,5 B 44,5 55,5 55,5 55,5 55,5 C 9,5 113,75 116,25 118,75 122,25 D 11,9 15,9 15,9 15,9 15,9 E 11,9 11,9 11,9 11,9 11,9 A 226, 231,5 236,5 241,5 248,5 B 57, 57, 57, 57, 57, C 112,5 115,25 117,75 12,25 123,75 D 15,9 15,9 15,9 15,9 15,9 E 11,9 11,9 11,9 11,9 11,9 A 229, 234,5 239,5 244,5 251,5 B 58,5 58,5 58,5 58,5 58,5 C 114, 116,75 119,25 121,75 125,25 D 15,9 15,9 15,9 15,9 15,9 E 11,9 11,9 11,9 11,9 11,9 A 232, 237,5 242,5 247,5 254,5 B 6, 6, 6, 6, 6, C 115,5 118,25 12,75 123,25 126,75 D 15,9 15,9 15,9 15,9 15,9 E 11,9 11,9 11,9 11,9 11,9 A 236,5 242, 247, 252, 259, B 62,25 62,25 62,25 62,25 62,25 C 117,75 12,5 123, 125,5 129, D 15,9 15,9 15,9 15,9 15,9 E 11,9 11,9 11,9 11,9 11,9 A 241, 246,5 251,5 256,5 263,5 B 64,5 64,5 64,5 64,5 64,5 C 12, 122,75 125,25 127,75 131,25 D 15,9 15,9 15,9 15,9 15,9 E 11,9 11,9 11,9 11,9 11,9 1 GR38 + GR33 16 2 1 13 15 18 A 242,5 247,4 252,4 258,2 B 55,5 55,5 55,5 55,5 C 118,25 12,7 123,2 126,1 D 15,9 15,9 15,9 15,9 E 13,75 13,75 13,75 13,75 45

GR38 + GR33 18 2 22 25 28 2 1 13 15 18 A 245,5 25,4 255,4 261,2 B 57, 57, 57, 57, C 119,75 122,2 124,7 127,6 D 15,9 15,9 15,9 15,9 E 13,75 13,75 13,75 13,75 A 248,5 253,4 258,4 264,2 B 58,5 58,5 58,5 58,5 C 121,25 123,7 126,2 129,1 D 15,9 15,9 15,9 15,9 E 13,75 13,75 13,75 13,75 A 251,5 256,4 261,4 267,2 B 6, 6, 6, 6, C 122,75 125,2 127,7 13,6 D 15,9 15,9 15,9 15,9 E 13,75 13,75 13,75 13,75 A 256 26,9 265,9 271,7 B 62,25 62,25 62,25 62,25 C 125 127,45 129,95 132,85 D 15,9 15,9 15,9 15,9 E 13,75 13,75 13,75 13,75 A 26,5 265,4 27,4 276,2 B 64,5 64,5 64,5 64,5 C 127,25 129,7 132,2 135,1 D 15,9 15,9 15,9 15,9 E 13,75 13,75 13,75 13,75 1 GR38 + GR38 16 18 2 16 18 2 22 25 28 A 246, - - - - - B 55,5 - - - - - C 12, - - - - - D 15,9 - - - - - E 15,9 - - - - - A 249, 252, - - - - B 57, 57, - - - - C 121,5 123, - - - - D 15,9 15,9 - - - - E 15,9 15,9 - - - - 46

1 GR38 + GR38 2 22 25 28 2 16 18 2 22 25 28 A 252, 255, 258, - - - B 58,5 58,5 58,5 - - - C 123, 124,5 126, - - - D 15,9 15,9 15,9 - - - E 15,9 15,9 15,9 - - - A 255, 258, 261, 264, - - B 6, 6, 6, 6, - - C 124,5 126, 127,5 129, - - D 15,9 15,9 15,9 15,9 - - E 15,9 15,9 15,9 15,9 - - A 259,5 262,5 265,5 268,5 273, - B 62,25 62,25 62,25 62,25 62,25 - C 126,75 128,25 129,75 131,25 133,5 - D 15,9 15,9 15,9 15,9 15,9 - E 15,9 15,9 15,9 15,9 15,9 - A 264, 267, 27, 273, 277,5 282, B 64,5 64,5 64,5 64,5 64,5 64,5 C 129, 13,5 132, 133,5 135,75 138, D 15,9 15,9 15,9 15,9 15,9 15,9 E 15,9 15,9 15,9 15,9 15,9 15,9 Available flanges and shafts for GR38 Flange ed alberi disponibili per GR38 Type flange 2C4 Flangia tipo 2C4 Type shaft 2C4 Albero tipo 2C4 Max torque / Coppia max: 21 Nm * Standard multiple pumps are delivered with both stages in fluid communication. When placing an order, it is necessary to specify if the two stages will handle different kinds of fluids or fluids coming from more than one reservoir. / Le pompe multiple sono consegnate con entrambi gli stadi in comunicazione di fluido. In fase di ordine, occorre specificare se la pompa multipla utilizza oli differenti sui diversi stadi o provenienti da più di un serbatoio. 47

GR47 - Group 3 tandem pumps 1 GR47 + GR28 28 32 36 4 45 5 2 4 6 8 1 13 A 292, 297,5 32,5 37,5 314,4 B 67,5 67,5 67,5 67,5 67,5 C 168, 17,75 173,25 175,75 179,25 D 19,5 19,5 19,5 19,5 19,5 E 11,9 11,9 11,9 11,9 11,9 A 296, 31,5 36,5 311,5 318,4 B 69,5 69,5 69,5 69,5 69,5 C 17, 172,75 175,25 177,75 181,25 D 19,5 19,5 19,5 19,5 19,5 E 11,9 11,9 11,9 11,9 11,9 A 3, 35,5 31,5 315,5 322,4 B 71,5 71,5 71,5 71,5 71,5 C 136, 138,75 141,25 143,75 147,2 D 19,5 19,5 19,5 19,5 19,5 E 11,9 11,9 11,9 11,9 11,9 A 34, 39,5 314,5 319,5 326,4 B 73,5 73,5 73,5 73,5 73,5 C 174, 176,75 179,25 181,75 185,25 D 19,5 19,5 19,5 19,5 19,5 E 11,9 11,9 11,9 11,9 11,9 A 38,5 314, 319, 324, 33,9 B 75,75 75,75 75,75 75,75 75,75 C 14,25 143, 145,5 148, 151,45 D 19,5 19,5 19,5 19,5 19,5 E 11,9 11,9 11,9 11,9 11,9 A 313,5 319, 324, 329, 335,9 B 78,25 78,25 78,25 78,25 78,25 C 178,75 181,5 184, 186,5 19, D 19,5 19,5 19,5 19,5 19,5 E 11,9 11,9 11,9 11,9 11,9 48

1 GR47 + GR33 28 32 36 4 45 5 2 1 13 15 18 A 322, 326,9 331,9 337,7 B 67,5 67,5 67,5 67,5 C 185,25 188,2 19,7 193,6 D 19,5 19,5 19,5 19,5 E 13,75 13,75 13,75 13,75 A 326, 33,9 335,9 341,7 B 69,5 69,5 69,5 69,5 C 187,25 19,2 192,7 195,6 D 19,5 19,5 19,5 19,5 E 13,75 13,75 13,75 13,75 A 33, 334,9 339,9 345,7 B 71,5 71,5 71,5 71,5 C 189,75 192,2 194,7 197,6 D 19,5 19,5 19,5 19,5 E 13,75 13,75 13,75 13,75 A 334, 338,9 343,9 349,7 B 73,5 73,5 73,5 73,5 C 191,75 194,2 196,7 199,6 D 19,5 19,5 19,5 19,5 E 13,75 13,75 13,75 13,75 A 338,5 343,4 348,4 354,2 B 75,75 75,75 75,75 75,75 C 194, 196,45 198,95 21,85 D 19,5 19,5 19,5 19,5 E 13,75 13,75 13,75 13,75 A 343,5 348,4 353,4 359,2 B 78,25 78,25 78,25 78,25 C 196,5 198,95 21,45 24,35 D 19,5 19,5 19,5 19,5 E 13,75 13,75 13,75 13,75 1 GR47 + GR38 28 32 2 16 18 2 22 25 28 A 325,5 328,5 331,5 334,5 339, 343,5 B 67,5 67,5 67,5 67,5 67,5 67,5 C 187,5 189, 19,5 192, 194,25 196,5 D 19,5 19,5 19,5 19,5 19,5 19,5 E 15,9 15,9 15,9 15,9 15,9 15,9 A 329,5 332,5 335,5 338,5 343, 347,5 B 69,5 69,5 69,5 69,5 69,5 69,5 C 189,5 191, 192,5 194, 196,25 154, D 19,5 19,5 19,5 19,5 19,5 19,5 E 15,9 15,9 15,9 15,9 15,9 15,9 49

GR47 + GR38 36 4 45 5 2 16 18 2 22 25 28 A 333,5 336,5 339,5 342,5 347, 351,5 B 71,5 71,5 71,5 71,5 71,5 71,5 C 191,5 193, 194,5 196, 198,25 2,5 D 19,5 19,5 19,5 19,5 19,5 19,5 E 15,9 15,9 15,9 15,9 15,9 15,9 A 337,5 34,5 343,5 346,5 351, 355,5 B 73,5 73,5 73,5 73,5 73,5 73,5 C 193,5 195, 196,5 198, 2,25 22,5 D 19,5 19,5 19,5 19,5 19,5 19,5 E 15,9 15,9 15,9 15,9 15,9 15,9 A 342, 345, 348, 351, 355,5 36, B 75,75 75,75 75,75 75,75 75,75 75,75 C 195,75 197,25 198,75 2,25 22,5 24,75 D 19,5 19,5 19,5 19,5 19,5 19,5 E 15,9 15,9 15,9 15,9 15,9 15,9 A 347, 35, 353, 356, 36,5 365, B 78,25 78,25 78,25 78,25 78,25 78,25 C 198,25 199,75 21,25 22,75 25, 27,25 D 19,5 19,5 19,5 19,5 19,5 19,5 E 15,9 15,9 15,9 15,9 15,9 15,9 1 GR47 + GR47 28 32 36 2 28 32 36 4 45 5 A 351, - - - - - B 67,5 - - - - - C 21, - - - - - D 19,5 - - - - - E 19,5 - - - - - A 356,5 36,5 - -- - - B 69,5 69,5 - - - - C 23, 25, - - - - D 19,5 19,5 - - - - E 19,5 19,5 - - - - A 36,5 364,5 368,5 - - - B 71,5 71,5 71,5 - - - C 25, 27, 29, - - - D 19,5 19,5 19,5 - - - E 19,5 19,5 19,5 - - - 5

GR47 + GR47 4 45 5 2 28 32 36 4 45 5 A 364,5 368,5 372,5 376,5 - - B 73,5 73,5 73,5 73,5 - - C 27, 29, 211, 213, - - D 19,5 19,5 19,5 19,5 - - E 19,5 19,5 19,5 19,5 - - A 369, 373, 377, 381, 385,5 - B 75,75 75,75 75,75 75,75 75,75 - C 29,25 211,25 213,25 215,25 217,5 - D 19,5 19,5 19,5 19,5 19,5 - E 19,5 19,5 19,5 19,5 19,5 - A 374, 378, 382, 386, 39,5 395,5 B 78,25 78,25 78,25 78,25 78,25 78,25 C 211,75 213,75 215,75 217,75 22, 222,5 D 19,5 19,5 19,5 19,5 19,5 19,5 E 19,5 19,5 19,5 19,5 19,5 19,5 Available flanges and shafts for GR47 Flange ed alberi disponibili per GR47 Type flange 3-C9 Flangia tipo 3-C9 Type shaft 3-C9 Albero tipo 3-C9 Max torque / Coppia max: 32 Nm Type flange SAEB-T13 Flangia tipo SAEB-T13 Type shaft SAEB-T13 Albero tipo SAEB-T13 Max torque / Coppia max: 6 Nm 51

GR55 - Group 3 tandem pumps 1 GR55 + GR28 5 63 75 9 2 4 6 8 1 13 A 323, 328,5 333,5 338,5 345,4 B 81,5 81,5 81,5 81,5 81,5 C 185, 187,75 19,25 192,75 196,25 D 23, 23, 23, 23, 23, E 11,9 11,9 11,9 11,9 11,9 A 332, 337,5 342,5 347,5 354,4 B 86, 86, 86, 86, 86, C 246, 251,5 256,5 261,5 268,5 D 23, 23, 23, 23, 23, E 11,9 11,9 11,9 11,9 11,9 A 34, 345,5 35,5 355,5 362,4 B 9, 9, 9, 9, 9, C 193,5 196,25 198,75 21,25 24,75 D 23, 23, 23, 23, 23, E 11,9 11,9 11,9 11,9 11,9 A 351, 356,5 361,5 366,5 373,4 B 95,5 95,5 95,5 95,5 95,5 C 199 21,75 24,25 26,75 21,25 D 23, 23, 23, 23, 23, E 11,9 11,9 11,9 11,9 11,9 52

1 GR55 + GR33 5 63 75 9 2 1 13 15 18 A 351,5 356,4 361,4 367,2 B 81,5 81,5 81,5 81,5 C 21,25 23,7 26,2 29,1 D 23, 23, 23, 23, E 13,75 13,75 13,75 13,75 A 36,5 365,4 37,4 376,2 B 86, 86, 86, 86, C 274,5 279,4 284,4 29,2 D 23, 23, 23, 23, E 13,75 13,75 13,75 13,75 A 368,5 373,4 378,4 384,2 B 9, 9, 9, 9, C 29,75 212,2 214,7 217,6 D 23, 23, 23, 23, E 13,75 13,75 13,75 13,75 A 379,5 384,4 389,4 395,2 B 95,5 95,5 95,5 95,5 C 215,25 217,7 22, 223,1 D 23, 23, 23, 23, E 13,75 13,75 13,75 13,75 1 GR55 + GR33 5 63 75 9 2 1 13 15 18 A 351,5 356,4 361,4 367,2 B 81,5 81,5 81,5 81,5 C 21,25 23,7 26,2 29,1 D 23, 23, 23, 23, E 13,75 13,75 13,75 13,75 A 36,5 365,4 37,4 376,2 B 86, 86, 86, 86, C 274,5 279,4 284,4 29,2 D 23, 23, 23, 23, E 13,75 13,75 13,75 13,75 A 368,5 373,4 378,4 384,2 B 9, 9, 9, 9, C 29,75 212,2 214,7 217,6 D 23, 23, 23, 23, E 13,75 13,75 13,75 13,75 A 379,5 384,4 389,4 395,2 B 95,5 95,5 95,5 95,5 C 215,25 217,7 22,2 223,1 D 23, 23, 23, 23, E 13,75 13,75 13,75 13,75 53

1 GR55 + GR38 5 63 75 9 2 16 18 2 22 25 28 A 355, 358, 361, 364, 368,5 373, B 81,5 81,5 81,5 81,5 81,5 81,5 C 23, 24,5 26, 27,5 29,75 212, D 23, 23, 23, 23, 23, 23, E 15,9 15,9 15,9 15,9 15,9 15,9 A 364, 367, 37, 373, 377,5 382, B 86, 86, 86, 86, 86, 86, C 278, 281, 284, 287, 291,5 296, D 23, 23, 23, 23, 23, 23, E 15,9 15,9 15,9 15,9 15,9 15,9 A 372, 375, 378, 381, 385,5 39, B 9, 9, 9, 9, 9, 9, C 211,5 213, 214,5 216, 218,25 22,5 D 23, 23, 23, 23, 23, 23, E 15,9 15,9 15,9 15,9 15,9 15,9 A 383, 386, 389, 392, 396,5 41, B 95,5 95,5 95,5 95,5 95,5 95,5 C 217, 218,5 22, 221,5 223,75 226, D 23, 23, 23, 23, 23, 23, E 15,9 15,9 15,9 15,9 15,9 15,9 1 GR55 + GR47 5 63 75 9 2 28 32 36 4 45 5 A 387, 391, 395, 4,5 43,5 48,5 B 81,5 81,5 81,5 81,5 81,5 81,5 C 223, 225, 227, 229, 231,25 233,75 D 23, 23, 23, 23, 23, 23, E 19,5 19,5 19,5 19,5 19,5 19,5 A 396, 4, 44, 48, 412,5 417,5 B 86, 86, 86, 86, 86, 86, C 31, 314, 318, 322, 326,5 331,5 D 23, 23, 23, 23, 23, 23, E 19,5 19,5 19,5 19,5 19,5 19,5 A 44, 48, 412, 416, 42,5 425,5 B 9, 9, 9, 9, 9, 9, C 231,5 233,5 235,5 237,5 239,75 242,25 D 23, 23, 23, 23, 23, 23, E 19,5 19,5 19,5 19,5 19,5 19,5 A 415, 418, 423, 427, 431,5 436,5 B 95,5 95,5 95,5 95,5 95,5 95,5 C 237, 239, 241, 243, 245,25 247,75 D 23, 23, 23, 23, 23, 23, E 19,5 19,5 19,5 19,5 19,5 19,5 54

1 GR55 + GR55 5 63 75 9 2 5 63 75 9 A 415, - - - B 81,5 - - - C 237, - - - D 23, - - - E 19,5 - - - A 424, 433, - - B 86, 86, - - C 338, 347, - - D 23, 23, - - E 19,5 19,5 - - A 432, 441, 449, - B 9, 9, 9, - C 245,5 25, 254, - D 23, 23, 23, - E 19,5 19,5 19,5 - A 443, 452, 46, 471, B 95,5 95,5 95,5 95,5 C 251, 255,5 259,5 265, D 23, 23, 23, 23, E 19,5 19,5 19,5 19,5 Available flanges and shafts for GR55 Flange ed alberi disponibili per GR55 Type flange SAEB-T15 Flangia tipo SAEB-T15 Type shaft SAEB-T15 Albero tipo SAEB-T15 Max torque / Coppia max: 7 Nm 55

GR72 - Group 4 tandem pumps 1 GR72 + GR47 94 11 125 15 175 2 2 28 32 36 4 45 5 A 44, 444, 448, 452, 456,5 461,5 B 125,5 125,5 125,5 125,5 125,5 125,5 C 232, 234, 236, 238, 24,25 242,75 D 29,75 29,75 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 19,5 19,5 A 443, 447, 451, 455, 459,5 464,5 B 127, 127, 127, 127, 127, 127, C 316, 32, 324, 328, 332,5 337,5 D 29,75 29,75 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 19,5 19,5 A 453, 457, 461, 465, 469,5 474,5 B 132, 132, 132, 132, 132, 132, C 238,5 24,5 242,5 244,5 246,75 249,25 D 29,75 29,75 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 19,5 19,5 A 463,5 467,5 471,5 475,5 48, 485, B 137,25 137,25 137,25 137,25 137,25 137,25 C 243,75 245,75 247,75 249,75 252, 254,5 D 29,75 29,75 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 19,5 19,5 A 473,5 477,5 481,5 485,5 49, 495, B 142,25 142,25 142,25 142,25 142,25 142,25 C 248,75 245,75 247,75 249,75 252, 254,5 D 29,75 29,75 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 19,5 19,5 A 484, 488, 492, 496, 5,5 55,5 B 147,5 147,5 147,5 147,5 147,5 147,5 C 254, 256, 258, 26, 262,25 264,75 D 29,75 29,75 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 19,5 19,5 56

1 GR72 + GR55 94 11 125 15 175 2 2 5 63 75 9 A 468, 477, 485, 496, B 125,5 125,5 125,5 125,5 C 246, 25,5 254,5 26, D 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 A 471, 48, 488, 499, B 127, 127, 127, 127, C 344, 353, 361, 372, D 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 A 481, 49, 498, 59, B 132, 132, 132, 132, C 252,5 257, 261, 266,5 D 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 A 491,5 5,5 58,5 519,5 B 137,25 137,25 137,25 137,25 C 257,75 262,25 266,25 271,75 D 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 A 51,5 51,5 518,5 529,5 B 142,25 142,25 142,25 142,25 C 262,75 267,25 271,25 276,75 D 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 A 512, 521, 529, 54, B 147,5 147,5 147,5 147,5 C 268, 272,5 276,5 282, D 29,75 29,75 29,75 29,75 E 19,5 19,5 19,5 19,5 1 GR72 + GR72 94 1 2 94 1 125 15 175 2 A 556,5 - - - - - B 125,5 - - - - - C 311,5 - - - - - D 29,75 - - - - - E 29,75 - - - - - A 559,5 562,5 - - - - B 127, 127, - - - - C 432,5 435,5 - - - - D 29,75 29,75 - - - - E 29,75 29,75 - - - - 57

GR72 + GR72 125 15 175 2 2 94 1 125 15 175 2 A 569,5 572,5 582,5 - - - B 132, 132, 132, - - - C 318, 319,5 324,5 - - - D 29,75 29,75 29,75 - - - E 29,75 29,75 29,75 - - - A 58, 583, 593, 63,5 - - B 137,25 137,25 137,25 137,25 - - C 323,25 324,75 329,75 335, - - D 29,75 29,75 29,75 29,75 - - E 29,75 29,75 29,75 29,75 - - A 59, 593, 63, 613,5 623,5 - B 142,25 142,25 142,25 142,25 142,25 - C 328,25 329,75 334,75 34, 345, - D 29,75 29,75 29,75 29,75 29,75 - E 29,75 29,75 29,75 29,75 29,75 - A 6,5 63,5 613,5 624, 634, 644,5 B 147,5 147,5 147,5 147,5 147,5 147,5 C 333,5 335, 34, 345,25 35,25 355,5 D 29,75 29,75 29,75 29,75 29,75 29,75 E 29,75 29,75 29,75 29,75 29,75 29,75 Available flanges and shafts for GR72 Flange ed alberi disponibili per GR72 Type flange SAED-23T Flangia tipo SAED-23T Type flange SAED-23T Flangia tipo SAED-23T Max torque / Coppia max: 12 Nm 58

Settima full complement of products SMT - high pressure industrial, lube and tool machines SMT16B - cooling,filtration and lube oil SMT8B - compact cooling and filtration SFO - shipyards diesel oil handling SMAPI (API676) - wide range of marine and industrial applications FOTP - high reliability boiler ignition/feeding marine application SMTU - USA lift and freight elevators SM - lift and freight elevators Continuum - high pressure, no noise fluid power applications 2VHL Continuum - low pressure no noise lube services FLOWMETERS - high pressure, high precision flow measurement MAGNETIC COUPLING - sealless option for no medium leackage Engineering and certification are a resource for our customers. If some certification is not available today, it could be available soon: ask Settima and we will answer.. 59

Settima, Italy Headquarter, r&d and production USA Warehouse ASIA Ltd. Sales Office Settima Meccanica Srl Settima - 292 Piacenza (Italia) tel. +39 523.365 fax +39 523.365299 www.settima.it info@settima.it 6