This will also provide you with the knowledge to insure long life for your Investment

Similar documents
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Boiler & Pressure Vessel Inspection discrepancies and failures

SANITARY GRAVITY SEWER LINE TESTING. B. Section CCTV Inspection of Gravity Sewer Lines

How to Prevent Liquid Damage Property Losses

Commercial Gas Water Heater

A cure for water damage in real estate

Selecting TEMA Type Heat Exchangers

SANITARY SEWER SPECIFICATIONS

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

How To Understand Evaporator

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

District Cooling Best Practices Piping Systems

Why is my air conditioner dripping on my customers?

Munchkin Heat Exchanger Maintenance

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

Gas-Fired, Residential Storage Type Water Heaters

Oil and Coolant Circulating Heating System. Model - OCSM

Solar Hot Water Heaters

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Stainless Steel Single and Dual Circulation Kits

Float and Thermostatic Traps Series H, C and X

Section SEWER PIPE INSTALLATION AND TESTING

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

CALIFORNIA PROPOSITION 65 WARNING:

SECTION STORM DRAINAGE SYSTEM

The soot and scale problems

Presentation Outline. Background

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Electric Water Heater

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Home comfort: water heating

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

ASME Packaged Indirect Fired Water Heater

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Avoiding Burning Through: Control the Inside Surface Temperature, Not the Pressure

Meeting the Challenge of Pipeline Emergency Repair

Wastewater Capital Projects Management Standard Construction Specification

Section 402. STORM SEWERS

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

Technical Information

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS

Steam Jet Vacuum Pumps

Tremco Fire Protection Systems Group Technical Bulletin

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Chilled Water HVAC Systems

COATING & WRAPPING OF UNDERGROUND PIPING

SEPTIC SYSTEM. Taking care of your. ... what you need to know

Originators of the Flexible Water Tube design

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Electric & Gas Water Heaters

SMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Rehabilitation of an Aging Concrete Reservoir Adit Tower

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

CA-48 TECHNICAL SPECIFICATION

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

CATHODIC PROTECTION SYSTEM DESIGN

Constructing Cistern Installations

Commercial Gas Water Heaters

HS-901(A) BASIC STEAM HEATING SYSTEMS

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Enclosed Football Stadium Design History and Lessons Learned

HEATING AND COOLING GENERATION AND DISTRIBUTION SYSTEMS

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Installation and maintenance instructions. Danfoss Vent

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

COMMISSIONING OF HVAC SYSTEMS

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Waste Collection Systems

Water Damage Prevention Risk Management Guidebook

TABLE OF CONTENT

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Tankless Water Heater

SunMor SM-V30 Solar Water Heater Installation Manual

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Commercial Electric Water Heater

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Technical Bulletin 144. Air Volume Conversions. by:

Select Radiators Installation Guide

Steam System Design and Best Practices Related to Kiln Drying

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Heaters. Use & Care Manual. Electric Point of Use IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

SOCALGAS APROACH TO PIPELINE INTEGRITY

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Transcription:

CONDUIT PIPE DRYING This Presentation will guide you to why systems fail! This will also provide you with the knowledge to insure long life for your Investment

Drainable and Dryable System Design Trough the Years 1950 to current Insulated carrier pipe inside a coated steel outer conduit Insulation thickness sized to keep coating from seeing 100 degrees F IE 6 steam 3 insulation. 1988 to current insulated carrier pipe inside insulated steel outer conduit Insulation thickness sized to keep annular space at 200 degrees F 6 steam 1.5 insulation

Why The Design Change The Federal Government and Universities had a high rate of system failures! Low annular space temperature Poorly maintained cathodic protection system Flooded systems not dried out and started up System Design Changes Dry in place Design a system with a higher internal temperature Eliminating exposed metal by covering anchors not just coating with paint

Is my System Performing at the Level It Was Designed to? What are the signs it s not! Steam vapor coming out of manhole cover Higher energy cost then budgeted for Water dripping from drains on end plates Manholes hotter then design and corrosion damage on end plates These are just a few signs your system is failing.

COMMON SIGNS OF CONDUIT FAILURE DUE TO WATER

Poor Protection During Construction Flooding of Manholes & Vaults Humidity During Instalation

PREVENTATIVE MEASURES NEEDED DURING INSTALLATION Dewatering plan in place when rain is a threat Sealing field joint areas nightly Complete field joints Seal with plastic wrap Only place as much pipe in the trench as can be protected

Effects Water Has On Conduit Piping Systems Corrosion of conduit pipe and service pipe 75% Loss Of Thermal Efficiency Due To Wet insulation Costly Repairs Needed And Even Total System Failure

212 F Dry Insulation Pipe Temp. Per Design Insulation Surface Temp. Per Design Inner Band of Dry Insulation (water in this region has boiled off) 212 F Wet Insulation Initial Flood Event Pipe Temp. Less Than 212 F Insulation Surface Temp..75 Pipe Temp Thermal Line Where water will no longer boil. The thermal line advances further outward during each wet cycle as the insulation k factor increases with diminished insulation quality. Outer Band of Wet Insulation Wet Insulation Initial Flood Event Pipe Temp. Greater Than 300 F Insulation Surface Temp..75 Pipe Temp. (after water in the conduit lowers to a level below the dry inner band Conduit interface temperature goes above 206 degrees F

Typical Areas Of Corrosion Depending on water level, carrier pipe corrosion can also occur. Outer Jacket Polyurethane Insulation Steel Conduit Areas of Corrosion Service Pipe Service Pipe Insulation Areas of Corrosion Water Level

Drying Of A Wet Conduit System Pressure test entire conduit to check for leaks in outer conduit pipe Flush any mud/debris that may have entered the conduit with clean water Ensure all plugs & valves are removed from end of system where air will be exhausted & begin the flow of dry air CFM required is based according to conduit diameter SCFM = annular space cross sectional area (ft.2) x air velocity (20ft. / sec.) x 60 (sec./ min.) Air must be oil free Have a dew point of -20F or less Not to exceeded 10psi of pressure in conduit Air must be induced at a constant and flow until system is dry Take a initial dew point reading Heating of the service pipe can aid in drying but must be done at a safe temperature Once a satisfactory reading of the air exiting the conduit is made stop the flow of air Allow system to rest for 4hrs then begin flow of air and read dew point of air exiting containment If reading is +20 dew point or lower the flow of air may be stopped. Continue the flow of air if greater than +20 dew point

Example SCFM Required To Properly Dry A 6 Steam Line With 2 of MinWool Insulation in a 12 ¾ Conduit Annular Space Cross Section (.33ft2) X Air Velocity (20ft/Sec) x 60(sec/min) = 130 SCFM Water Removal Rate Calculated By Measuring inlet air dew point and outlet air dew point Example Inlet air with a measurement of -20 Dew Point is removing.26 gallons of water per 100,000cfm Outlet air a measurement of +40 Dew Point = 5.4 gallons of water per 100,000cfm Water Removal Rate (5.40-.26) gal of Water x 20 SCFM x 1440 (minutes per day) = 1.5 Gallons Of Water Per Day 100,000SCF

How Long Will It Take To Dry? Type & thickness of insulation Length of conduit system wetted Temperature of service pipe (optional heating) Flow of air Incoming air dew point Constant Flow Of Air

EXAMPLE 4 High Temperature hot water line with 2 of MinWool Insulation In A 10 ¾ Conduit Approximately 350 of piping was fully wetted Initial dew point reading of HWS - (+55 F) - Based on the average of five (5) different tests over a 1 hour period HWR - (+60 F) - Again based on average of five (5) different tests over a 1 hour period Dew Point readings 3 days later HWS - (+22 F) - Based on the average of five (5) different tests over a 30 minute period Dew Point Reading 8 days after initial reading HWR - (+28 F) - Again based on average of five (5) different tests over a 30 minute period HWS - (-40F) - Based on the average of five (5) different tests over a 30 minute period Dew Point Readings After 4hr shutdown and equalization period HWR - (-35F) - Again based on average of five (5) different tests over a 30 minute period HWS - (-14 F) - Based on the average of one (1) test over a 5 minute period HWR - (-22 F) - Again based on average of one (1) test over a 5 minute period

Annual Dryness Testing Of Existing Systems Yearly pressure testing of outer containment Inspection that all check valves, drains and plugs are installed Inspection of Gland Seals/End Seals Dew point check of air inside containment Drying of conduit if presence of water is found