AERAULIX WATER HEATER HEAT PUMP ON VENTILATION
Energy saving regulations Obligations : 50 kwhep/m²/year DHW and ventilation : the most important energy users
Differents technologies to produce DHW with heat pump On unheated ambient air ATLANTIC solution : ODYSSEE Split ATLANTIC solution : ODYSSEE SPLIT On ventilation ATLANTIC solution : AERAULIX Extérieur de l habitat Intérieur de l habitat Unité clim ON / OFF Liaison frigorifique à mettre en place par un frigoriste
Why choose ambiant air? Where? Why? + - Non heated room > 20m 3 Garage, wash room, cellar Inside living volume with air intake and output to outdoor Installer capable to install electric water heater : Electric installer, plumber Easy to install Identical to electric tank No connection to ventilation system Very good performance Average yearly COP of 3 Well adapted to renovation Cool-down the room Risk of increase in heating demand Need to drill holes in the outside walls if connection to outdoor Possible problems with sealing High sound level for installation inside heated area (high air flow)
Why install a split water heater heat pump? Where? Why? + - Extérieur de l habitat Intérieur de l habitat Small house no garage With space in living volume Installer with refrigerant training: Cooling installer Small space requirement for the tank Same connections as electric tank Easy replacement of electric tank Small holes in the wall to pass piping No risk for sealing Good performance Average yearly COP of 2,5 Installer with qualification Cooling installer Installation complicated Connections through the wall Positionning of outdoor unit Unité clim ON / OFF Well adapted for renovation Or new construction When low noise level is very important Liaison frigorifique à mettre en place par un frigoriste
Why install a ventilation heat pump water heater? Installation / Target + - House with hygro B ventilation compatible with ventilator power of Aeraulix Medium size Installer capable to install an electric tank with ventilation knowhow Electric installer, plumber With ventilation knowhow Very good performance Average yearly COP of 3 Recover heat on extract used air Installation Connection on ventilation circuit inside the living area Well adapted to New build or renovation Of houses < 20 years old Commissionning The ventilation system has to be installed correctly Risk if breakdown Product 2 in 1: complex. Break-down of one stops the complete unit.
An increasing market Market was initiated by technologies working on ambiant air but excellent growth for ventilation based heat pumps. Evolution marché chauffe-eau thermodynamique Projection Volumes 120000 100000 80000 60000 40000 20000 0 2010 2011 2012 2013 2014 Années NEUF RENO
WATER HEATER HEAT PUMP ON VENTILATION THE PRODUCT
Ventilation water heater heat pump A product 2 in 1 : Ventilation + DHW Heat pump + ventilator Low Energy (no motor)
Recommandations for installation Installation in living area Central collector or in-line inside living area or insulated 50mm thickness Positionned not to close to living / sleeping room Lenth max output : 6m Length max collector : 6 m 1 bent on the worst condition conduct Caisson collecteur ( no motor )
Practical dimensions the most compact in the market : dia only 588 mm Avantage : integrates in a cupboard 600 X 600 Limited footprint
Ergonomics simplifies installation Front or top access to all connections. Avantage : Installation and maintenance easy small space requirement (corner or cupboard) Ventilation conduct Electric connection Backup heater & anti corrosion module Hot water connection and Cold water connection
Optimised construction for record performances Low energy direct current Ventilator, condenser outside the tank. Avantage : best performances of the market : record COP even with small ventilation speed and electric consumption. Expansion - 1 single échanger (condenser) - 1 single pump (compressor) Ventilator Compressor Evaporator
Adapted for Transport Rotativ Compresseur in horizontal position, handling grips. Avantage : Transport horizontal allowed easy handling on installation site.
Optimised solution for ventilation Connections dia. 125 on the top, totally sealed, with seal. Avantage : classic installation of ventilation system, no losses through leaks, sealing test optimised.
Integrated intelligence pressure sensors integrated : setting simplified, operation assured even with dirty filters, perfectly adapted to humidity controlled ventilation by automatic flow variation. Possibility to work in self adjusting system : water heater with constant pressure Avantage : simple installation and long term hot water production possibility to connect to complex ventilation circuits. 1 single stock reference for Self-adapting or Hygro
Function with increasing pressure 250 200 Pst (Pa) Ventilation curve Aéraulix 150 100 50 0 0 50 100 150 200 250 300Qvm (m3/h) 350 limite CSTBat courbe enveloppe courbe 150 Pa courbe 120 Pa
Maintenance Filter F5 located on the top, on rail.
Adapted to needs Regulation Atlantic : simple navigation in menus. programming according to life mode. Avantage : less time for installation and energy saving for user
Functions for installer Menu TEST : Check all functions after commissionning Check points : heat pump, ventilation ventilator, electric backup, sensor values Menu Settings : Simple settings : pressure setting, antilegionella, water temperature setting on permanent display
simple use for customer Mode Info : usefull and complet Disply of : Water temperature, heat pump, Incomeing air, pressure Display of working hours in mode Heat pump or ELEC Filter status 5 working modes : AUTO : heat pump or electric backup ECO : only heat pump BOOST : operation of heat pump and backup ( fast heating ) ABSENCE: heat pump stopped, ventilation only. Water tank with frost free protection. Heating up the day before programmed returning to home
Long life time Maximised anti-corrosion protection : fitted with new device ACI Performance Avantage : long life time of the tank. Stéatite backup : the resistance is in a sleeve with high exchange surface and can be replaced without draining. Access on the front. Avantage : easy maintenance and long tank life
Technical data FUNCTIONS DHW Capacity Data Heat-up time from 15 to 51 C, air at +20 for 200L Qpr (kwh/j) 200 L 10H30 Temperature DHW max with heat pump 62 C Depends on use Adjustable Temperature DHW 45 to 62 C Protection anti-corrosion Steatite backup (anode titanium) Certification ACI Performace 1800W Objectif NF Performance
Technical data FUNCTIONS Heat pump Data COP at +20, 60m3/h (Selon EN 255-3) 3.2 Refrigerant R134 A Heat pump power 800 W Refrigerant charge 750g Sound level Objectif 36dB(A) à 2 m
Technical data FUNCTIONS Ventilation Data Electric power consumption hygro Low Energy/3 bedroom house Compatibility Certification Max Air Volume Base air volume Adjustable pressure 16W Hygro A, Hygro B et self-adapting CSTBat 265 m3/h For 3 bedroom flat low energy with hygro B : 60 m3/h 60-200 Pa
WATER HEATER HEAT PUMP ON VENTILATION PERFORMANCES
Record performances in all applications COP = 3.2 at 60m3/h at 20 C : best performance in the market reduced electric power consumption with electronic switched motors : only16w for a 3 bedroom flat, 1 bathroom, 1WC Avantage : Optimise thermal calculation maximum energy savings for end user (up to 75% compared to electric water heater) Return on investment in approx 4 ans
The best ventilation heat pump water heater compact Régulation adapted for installer and user Long life Integrated intelligence Optimised design