GS 1 Protecting Data Centers Against Intentional Electromagnetic Interference and High Altitude Electromagnetic Pulse



Similar documents
EMP... Electromagnetic Pulse. one of the greatest threats facing technology-driven clients today

Electromagnetic Pulse: Effects on the U.S. Power Grid

Network Vulnerability to Electromagnetic Pulse Attacks

Digital C4I Interoperability: The EM Protection Issue

Harmful Interference into Satellite Telecommunications by Cyber Attack

The Early-Time (E1) High-Altitude Electromagnetic Pulse (HEMP) and Its Impact on the U.S. Power Grid

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Does it state the management commitment and set out the organizational approach to managing information security?

Metrics and Methods for Security Risk Management

IEC and CISPR Standards

Disruptive Effects of Electromagnetic Interference on Communication and Electronic Systems

EEI Business Continuity. Threat Scenario Project (TSP) April 4, EEI Threat Scenario Project

I. PURPOSE II. SITUATION AND ASSUMPTIONS

INFRAGARD.ORG. Portland FBI. Unclassified 1

Physical Security of Remote Pilot Stations and Aircrafts (when On Ground)

Supply Chain Risk Management. Operating ahead of the threat, not behind the vulnerabilities

New England Defense Contracting Trends

Investigation of the Risk of Electromagnetic Security on Computer Systems

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual

Introduction. So, What Is a Btu?

Arc Terminator Active Arc-Resistant Switchgear

Fiber Optics: Engineering from Global to Nanometer Dimensions

Telephone- and leased line modem for industrial applications TD-36

Radio Frequency Interference (RFI) Shielding Principles

BUILDING DESIGN FOR HOMELAND SECURITY. Unit IV Vulnerability Assessment

Security & Surveillance Cabling Systems

Services we provide. Tel:

Subj: SURVIVABILITY POLICY AND STANDARDS FOR SURFACE SHIPS AND CRAFT OF THE U.S. NAVY

Security+ Guide to Network Security Fundamentals, Fourth Edition. Chapter 13 Business Continuity

Chicago Center Fire Contingency Planning and Security Review

CONSIDERATIONS FOR A POWER TRANSFORMER EMERGENCY SPARE STRATEGY FOR THE ELECTRIC UTILITY INDUSTRY

Radio waves and health. Mobile communications

Measurement of Protection from Cell Phone Radiation by 8ight Protect Disc

Rack mounted telephone- and leased line modem for industrial applications

THE NARTE EMC ENGINEER CERTIFICATION PROCESS - A PERSONAL EXPERIENCE

NIST Disaster Resilience Framework

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Clinic Business Continuity Plan Guidelines

Secure and Reliable Wireless Communications for Geological Repositories and Nuclear Facilities

TELECOMMUNICATION SYSTEM HAZARD MITIGATION STRATEGIC PLANNING

30 In Compliance October

Software Radio Applications

Public Private Partnerships and National Input to International Cyber Security

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Microwave Photonic Systems Inc. Joshua L. Korson & Richard J. Stewart

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

NUCLEAR HIGH ALTITUDE ELECTROMAGNETIC PULSE IMPLICATIONS FOR HOMELAND SECURITY AND HOMELAND DEFENSE

What do SAE standards offer the Automotive Electronics industry?

Policy wording. General conditions. AMI Businesspack Business Insurance. Your duty to comply. About this Businesspack policy. Interpreting this Policy

Analysis of Immunity by RF Wireless Communication Signals

OpenBTS Development Kit

This presentation will introduce you to the concepts and terminology related to disaster recovery planning for businesses.

PBSi Business Continuity Planning

Report of the Commission to Assess the Threat to the United States from Electromagnetic Pulse (EMP) Attack

A DESCRIPTION OF THE SOFTWARE ELEMENT OF THE NASA EME FLIGHT TESTS

Clinic Business Continuity Plan Guidelines

Professional Development Kit Series

40 Years of experience in EMC testing

White Paper Assured PNT Inside Military Ground Vehicles Using D3

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

Common Power Problems & Power Protection Solutions

BUILDING DESIGN FOR HOMELAND SECURITY. Unit I Building Design for Homeland Security

SSM3K335R SSM3K335R. 1. Applications. 2. Features. 3. Packaging and Pin Configuration Rev.3.0. Silicon N-Channel MOS (U-MOS -H)

with Component Rating A Simple Perspective

Waves - Transverse and Longitudinal Waves

Electromagnetic Compatibility Considerations for Switching Power Supplies

Understanding SMD Power Inductors. Application Note. July 2011

Critical Infrastructure

BUSINESS CONTINUITY PLAN

Analog signal converters CC-E I/I Current / current isolators

Safety and security are simply good business.

USE OF MOBILE TELEPHONES AND OTHER WIRELESS COMMUNICATIONS DEVICES - INTERFERENCE WITH ELECTRONIC MEDICAL EQUIPMENT

Comparison of Information Sharing, Monitoring and Countermeasures Provisions in the Cybersecurity Bills

Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER

The use of Conductive Cement in data Centers as Building Material

Mobile Phone Base-Station Audit

Results of Airborne Monitoring by the Ministry of Education, Culture, Sports, Science and Technology and the U.S. Department of Energy

Simulation électromagnétique 3D et câblage, exemples dans l'automobile et aéronautique :

How to Prevent Power Surges: The Leading Cause of Serial Device Server Failures

AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Integrated Metering Systems, Inc.

Developer s Guide to Submetering Submetering Specifications for Multi-Housing Construction

CHAPTER 4. Electromagnetic Spectrum

SARPS about Emergency frequency. 12 May 2015

Transcription:

GS 1 Protecting Data Centers Against Intentional Electromagnetic Interference and High Altitude Electromagnetic Pulse Data Center Facility Infrastructure Threat and Mitigation Considerations 1

GS 1 Protecting Data Centers Against Intentional Electromagnetic Interference and High Altitude Electromagnetic Pulse Michael A. Caruso Director, Government & Specialty Business Development 2

The Concern Functions of Government, Private and Public Data Centers are becoming an increasingly significant component of the Critical Infrastructure The concern over the effects of HEMP and IEMI has grown exponentially in non-government applications. The need to address HEMP and IEMI protection in Data Centers that support Critical Infrastructure is urgent. Current Data Center Designs and IT Equipment Designs do not address HEMP and IEMI 3

Terminology Electromagnetic Pulse (EMP) An umbrella term identifying two forms of damaging high power electromagnetic signals High-altitude Electromagnetic Pulse (HEMP) Damaging electromagnetic signals (>50,000 volts/meter) emitted from a nuclear detonation in outer space at any altitude above 18 miles (30 km) Note: No damaging near field or radiation effects Intentional Electromagnetic Interference (IEMI) Damaging and/or Disruptive data altering electromagnetic signals caused by the malicious use of electromagnetic weapons (nondetonation, within targeted footprints) 4

Known IEMI THREATS Boeing CHAMP Truck Mounted Suitcase 5

Risk Potential How much EMP is needed to destroy your data equipment? Volts per meter (V/m) are the standard units of electric field strength used to determine electromagnetic immunity in products and equipment. Most electronic equipment can survive a pulse of 10 Volts per meter. An EMP would create a pulse of >10,000 V/m. 6

Risk Potential Immunity Standards IT Equipment - 10 Volts/meter Medical Equipment 10 Volts/meter Network Telephone Equipment 10 Volts/meter Aircraft- (HIRF) 7,200 Volts/meter Automobiles 100 Volts/meter Military Equipment 200 Volts/meter 7

MITIGATION and PROTECTION PROTECTION LEVEL 1 (Survival of Data and Equipment) EMP Protected Environment With EMP protected enclosures and treated points of entry, your data and processing equipment will survive. Although the power, cooling, and utilities in an unprotected host facility may not be immediately available, your equipment will remain safe. And, when power, cooling and utilities and are restored, your data equipment will be fully operable. 8

MITIGATION and PROTECTION PROTECTION LEVEL 2 (Survival & Continuous Operations of Data & Equipment) Independent Power and Utilities If an EMP event occurs, your data and processing equipment will continuously operate with a fully independent and protected power and utility source. This unit may be located inside your suite or outside the existing data center facility. Your data processing and communication will not be interrupted. 9

MITIGATION and PROTECTION HVAC, Generator & Telecommunications Must be addressed for Protection Level 2 10

CONCLUSIONS Computer/Business/Distribution/Communication/Manufacturing systems have become a significant part of our modern critical infrastructure system and must now consider EMP Protection Both narrowband and wideband EMP waveforms can be produced by nonlethal weapons using modern technology Modern electronics are extremely vulnerable EMP waveforms Protection measures are available, but many businesses are not aware of the threat and/or not willing to invest the time or money There is a prevailing It Can t Happen attitude..but it will and has! 11

Thank you Michael A. Caruso Director, Government & Specialty Business Development 1360 North Wood Dale Road Suite G Wood Dale, IL 60191-1075 630-912-1031 Office 630-776-5267 Cell 630-912-1131 Fax Mike.Caruso@ets-lindgren.com 12