FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)



Similar documents
Fire Alarm System Monitoring - CAN/ULC-S561-03

CAN/ULC-S Installation and Services for Fire Signal Receiving Centres and Systems- Ottawa 2013

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

FIRE ALARM SYSTEM RECORD OF COMPLETION

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

FIRE ALARM SYSTEM RECORD OF COMPLETION

Module 4, Lesson 12 Fire Alarm Systems

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

HERNANDO COUNTY FIRE ALARM GUIDELINES

Central Station Interface with Fire Alarm and the Relevant Codes & Standards

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Commercial Fire Alarm Standards July 1, 2010 Edition Page 1 of 14

EXHIBIT A SCOPE OF WORK

The Evolution of Requirements for Supervising Station Alarm Systems

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

BASIC FIRE ALARM TRAINING

1.0 General. Inspection, Testing, and Maintenance 1 of 8

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Program No Section Heading

Agenda. Agenda (continued) Fundamentals of Fire Alarm Systems

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

ARTICLE III. - FALSE FIRE ALARMS

Bold items are particular to the City of Euless

Michael Catalano 24 Nassau Avenue, Islip NY Phone (631) Chief Fire Marshal Fax (631)

rpsa FIRE PROTECTION ENGINEERS

Approval Standard for Central Station Service for Fire Alarms and Protective Equipment Supervision

NATIONAL FIRE ALARM AND SIGNALING CODE

SECTION FIRE ALARM AND DETECTION SYSTEM

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

What Should I Expect From My Alarm Monitoring Station?

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

City of Bettendorf Fire Alarm System Requirements

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

Austin Independent School District Police Department Policy and Procedure Manual

Fire Alarm Log Book. Any activity regarding this system must be documented in writing.

SECURITY & MONITORING QUICK GUIDE

BOOK 101 PAGE 2fi8. OF TILLAMOOK COUNTY, OREGON JUNE WAGNEfi. The Board of Commissioners for Tillamook County, Oregon

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Chapter 103 Alarm Ordinance 1. PURPOSE.

SECURITY SYSTEM MANUAL

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

Fire Prevention Coffee Break Training. November 2015

Loop Start or Ground Start?

FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE

FIRE ALARM APPLICATION

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

TITLE 9-1 BURGLAR AND HOLDUP ALARM USERS REGISTRATION; FALSE ALARM

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

SECURITY SYSTEM NOTES

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS

Agenda Cover Memorandum

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

AETNA FIRE ALARM SERVICE CO., INC.

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM

DTW Works Master Specification Version 2006

City's Central Dispatch shall be the Dispatch Station at the Mt. Vernon Police Station.

Using your LED Plus keypad

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

NetworX NX-6V2. LED Keypad User Manual

CITY OF BLAINE ORDINANCE NO AMENDING ARTICLE XI. ALARM SYSTEMS OF THE ZONING ORDINANCE OF THE CITY OF BLAINE

HILLS Series LED Code Pad User Manual

FALSE SECURITY OR MEDICAL ALARM ORDINANCE Baroda Township Ordinance No. 30

BUILDING DESIGN STANDARDS UNIVERSITY SERVICES ELECTRONIC SAFETY AND SECURITY - DIVISION 28 Fire Alarm Systems

Fire Alarm System Plans Review Checklist Property location Date of Review

SECURITY SYSTEM NOTES

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

HILLS Series LED Code Pad User Manual

City of Temple Burglar Alarm Permit Process Information Sheet

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

The Jefferson County Board of Supervisors does ordain as follows:

PURPOSE AND GENERAL POLICY DEFINITIONS ALARM PERMITS (1) Permit Fees

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

Alarm Permits - A Practical Definition

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

Fire Watch. Fire safety systems may not be deactivated in whole or in part for any reason other than for repairs or hot work.

ALARM SYSTEMS INFORMATION & REQUIREMENTS

TOWN OF SIDNEY BYLAW NO A BYLAW TO REGULATE THE USE AND POSSESSION OF SECURITY ALARM SYSTEMS IN THE TOWN OF SIDNEY

Environment of Care Fire Safety Management Plan 2014

Control/Communicator Installation Manual

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Chapter 67 ALARM SYSTEMS

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

Transcription:

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service) The information provided in this user guide pertains to fire suppression sprinkler system monitoring service provided over dual communication paths, typically being a conventional dial tone telephone line and a Cellular Data Path. If you are in doubt as to the communication facilities employed for your service please contact our ULC Listed Signal Receiving Center at 800-265-7562 and we will be glad to answer any questions you may have. This User Guide is provided to help you understand the services we are providing and the relationship between Damar Security Systems and your fire suppression sprinkler system service company or contractor. Damar Security Systems provides inspection, testing and repair services for the fire alarm signal transmission equipment but we do not test, inspect or maintain your fire suppression sprinkler system. While we are required to test the transmission of signals we do not provide the annual sprinkler system inspection and test required by the Ontario Fire Code. In many cases the Ontario Building Code and/or the Ontario Fire Code requires the monitoring and supervision of a fire suppression sprinkler system by means of our services. Continuing monitoring and supervision may be part of the requirements for continued occupancy of your premises. Damar Security Systems is listed by the Underwriters Laboratories of Canada for the provision of Fire Signal Receiving Center Systems and Services and as such our service meets or exceeds the requirements of the Authorities Having Jurisdiction. Damar Security Systems has been providing the highest degree of service and protection for our fire alarm monitoring customers since 1977. We appreciate the trust you have placed with us! We monitor as a minimum the following conditions: Waterflow Alarm Pressure Supervisory Water Supply Valve

Where there is a possibility of freezing we will also monitor the ambient temperature within the room housing the sprinkler riser(s). Waterflow Alarm: This is an indication that there is water flowing through the sprinkler system. This can be caused by a sprinkler opening as a result of a fire or high temperature condition, a damaged or broken sprinkler, or other major leak in the sprinkler system. The fire department will be notified within thirty seconds of receipt of a waterflow alarm at the signal receiving center. A customer representative will be notified immediately also. Pressure Supervisory: This is an indication that the pressure in the sprinkler system has dropped to a point where false waterflow alarms may be received as a result of changes in pressure in the municipal water supply system. Many new fire suppression sprinkler system installations incorporate an automatic excess pressure pump arrangement to bring the pressure up prior to our signal set point. Should the excess pressure drop below a set point we will notify a customer representative as soon as possible. Supply Valve Supervisory: In order to ensure that there is always a water supply available to extinguish a fire, Damar Security Systems monitors the condition of the main water supply valve to the sprinkler system. Upon receipt of a valve closure signal we will notify a customer representative as soon as possible. Ambient Room Temperature: If provided, should the temperature within the room housing the fire suppression sprinkler system decrease to where there is a possibility of freezing, we will notify a customer representative as soon as possible. Cabinet Tamper Signal: In the event that an unauthorized person should open our transmitter cabinet we will receive a tamper signal. Please make sure that all of your staff understands that there are no user serviceable components contained within our cabinet. In the event that the cabinet is opened we are obligated to attend at the premises and verify the integrity of our equipment and connections. Unless the cabinet tamper is the result of a technical problem our service response will be a chargeable service call. Low Battery Signal: We supervise the condition of the standby battery within our signal transmitter. If we receive a battery trouble our service technicians will investigate and take appropriate action.

Fail To Test: Our equipment will automatically generate a test signal to our signal receiving center. In the event that we do not receive an automatic test signal we will initiate corrective action. Communication Channel Failure: The communication channels between your premises and our Signal Receiving Centre are monitored by our transmission equipment, In the event of a failure or fault on one channel the surviving channel with report the problem. Upon receipt of this trouble we will commence corrective action to restore full service. In the unlikely event that both channels fail there will be an audible signal from the transmission system control station. Simply enter the digits 5 4 3 2 1 to silence the sounder and telephone our monitoring centre as soon as possible. Notification Procedure: It is required that we notify the fire department within thirty seconds of receipt of a waterflow alarm signal and notify you as soon as possible. In the absence of other direction from you, we will notify you as soon as possible following receipt of a supervisory or trouble signal. One exception is that in the event of a power failure where we have reason to believe that it is wide spread, we likely will not notify you immediately of a primary power failure. You do have the option to give us direction in writing to hold the notification of fire alarm panel supervisory and/or trouble signals until the next working day. Such direction to us should only be given after carefully consideration of all aspects of the building fire protection system and the effect this may have on the premises fire safety plan. Contact or Call List: It is important that we have a minimum of three contact persons to notify in the event of a fire alarm, supervisory or trouble conditions. Please indicate to the people on your call list that the caller display when we call will be DSRCALARMCO - calling telephone number "519-346-6342" - and it is important to answer our call. Obviously during the daytime occupied hours the contact would be to the premises. Should there be any changes in your staff or in their contact information please ensure that our Signal Receiving Center receives the updated information. Fax to 800-688-7721 or email to csadmin@damar.net. Restoration of Alarm, Supervisory or Trouble Conditions: Following a waterflow alarm or a supervisory condition it will necessary to enter a reset code into the transmission system control keypad. The code is 5 4 3 2 1.

Notes Regarding Your Fire Sprinkler System: With regard to the operation of the fire suppression sprinkler system please be aware of the following. You should consult your sprinkler system service provider for the proper instructions for resetting the system, and correcting pressure drop and supply valve supervisory conditions. While our operators are more than willing to provide as much assistance as possible for our customers please understand that because of the numerous sprinkler system configurations and the related equipment which is not supplied, installed or serviced by Damar Security Systems our operators do not have adequate information to give you instructions or assistance in the operation of your fire suppression sprinkler system Working On The Sprinkler System: Please be sure that construction and sprinkler system service contractors use caution around the sprinkler system. In the event that someone will be working on, or testing the sprinkler system please ensure that they call our Signal Receiving Center PRIOR to performing any work. They will need to identify the system number and provide their name and contact telephone number as well as an indication of how long they will be working on the sprinkler system. The system number is posted clearly on the sprinkler system and our signal transmitter cabinet. The telephone number for our signal receiving center is 800-265-7562 and this is also posted. They should place the monitoring out of service for sufficient time to complete their work. Should they complete their work prior to the indicated time they may call us again and we will be glad to place the monitoring back in service. If they do not call us the monitoring will automatically return to service at the designated time. This means that if they should continue to work on the fire alarm system after the expiration of the "out of service" time we will dispatch the fire department should we receive a fire alarm signal. Our Obligations: We will visit your premises once every two months to perform a waterflow alarm test, once every six months to test the supervisory equipment, and once per year to conduct an operational test and inspection of our signal transmitting equipment. Damar Security Systems provides a system service agreement on the equipment that we supply and install and this means that except for intentional damage beyond our control, there is no charge for any repairs necessary to keep your fire suppression sprinkler system monitoring connection in proper operating order. Please note that our system service agreement does not apply to the initiating devices on your sprinkler riser. Follow Up Required: Upon receipt of an alarm signal we must notify the responding authority within thirty seconds. If you do not reset your waterflow alarm condition within eight hours we must follow-up and

determine when you will be resetting the system. Upon receipt of a supervisory or trouble signal we will notify you as soon as possible and if you do not remedy a problem within twelve hours we must follow-up with you. Where necessary, Damar Security Systems can issue a certificate of conformance attesting to the fact the service being provided meets the requirement of CAN/ULC S-561, a National Standard of Canada. Important Note. The terms, services and procedures contained herein are general in nature and in some cases the service provided or our obligations may be modified per the formal agreement for service.