Green Computing: Datacentres



Similar documents
Green Computing: Datacentres

Cloud Computing Data Centers

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

Managing Data Centre Heat Issues

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

AbSTRACT INTRODUCTION background

Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs

Last time. Data Center as a Computer. Today. Data Center Construction (and management)

Green Data Centre Design

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers

Data Centers: Definitions, Concepts and Concerns

SoSe 2014 Dozenten: Prof. Dr. Thomas Ludwig, Dr. Manuel Dolz Vorgetragen von Hakob Aridzanjan

Data Center Equipment Power Trends

Energy Efficiency Monitoring in Data Centers: Case Study at International Hellenic University. George Koutitas, Prof. L. Tassiulas, Prof. I.

How To Improve Energy Efficiency In A Data Center

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Data Center Energy Use, Metrics and Rating Systems

Specialty Environment Design Mission Critical Facilities

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Datacenter Efficiency

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Energy Efficiency and Availability Management in Consolidated Data Centers

EU Code of Conduct for Data Centre Efficiency

DataCenter 2020: first results for energy-optimization at existing data centers

Data Center Facility Basics

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE

Enabling an agile Data Centre in a (Fr)agile market

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Energy Management Services

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

The New Data Center Cooling Paradigm The Tiered Approach

Data Centre Testing and Commissioning

Analysis of data centre cooling energy efficiency

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

ICT and the Green Data Centre

Best Practices. for the EU Code of Conduct on Data Centres. Version First Release Release Public

Electrical Systems. <Presenter>

Metering and Managing University of Sheffield Data Centres. Chris Cartledge Independent Consultant

THE GREEN DATA CENTER

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Data Center Energy Profiler Questions Checklist

Data centres that deliver

Reducing the Annual Cost of a Telecommunications Data Center

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Re Engineering to a "Green" Data Center, with Measurable ROI

Australian Government Data Centre Strategy

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Direct Fresh Air Free Cooling of Data Centres

Introduction to Datacenters & the Cloud

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Optimization of energy consumption in HPC centers: Energy Efficiency Project of Castile and Leon Supercomputing Center - FCSCL

The Pros and Cons of Modular Systems

Greening Commercial Data Centres

Reducing Data Center Energy Consumption

Server Room Thermal Assessment

Data center upgrade proposal. (phase one)

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Office of the Government Chief Information Officer. Green Data Centre Practices

Ch. 4 - Topics of Discussion

Data Center Technology: Physical Infrastructure

Server Technology, Inc.

Building a data center. C R Srinivasan Tata Communications

GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCIE

White Paper RiZone The Rittal Management Software for IT infrastructures

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

Optimizing IT costs with Cloud. Tarmo Tikerpäe Datacenter SSP Microsoft Corporation

2014 Best Practices. for the EU Code of Conduct on Data Centres

2014 Best Practices. The EU Code of Conduct on Data Centres

Case Study. Cool and green: Citigroup s Frankfurt Data Center

How To Benchmark Power Production

Data Center Infrastructure Management: ERP for the Data Center Manager

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Smarter Data Centers. Integrated Data Center Service Management

Server Technology, Inc.

Measuring Power in your Data Center

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

European Code of Conduct for Data Centre. Presentation of the Awards 2016

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Capacity Planning in the Modern Datacenter

Power and Cooling for Ultra-High Density Racks and Blade Servers

Data Center Energy Efficiency Looking Beyond PUE

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How

Energy Performance Optimization of Server Room HVAC System

abstract about the GREEn GRiD

HPC TCO: Cooling and Computer Room Efficiency

Transcription:

Green Computing: Datacentres Simin Nadjm-Tehrani Department of Computer and Information Science (IDA) Linköping University Sweden Many thanks to Jordi Cucurull For earlier versions of this course material January 26, 2015 1

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Seminar groups Datacentre visit 2

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Chapter 4 and 5 of the 1 st Edition of the e-book on the course web (2009) Seminar groups Data centre visit 3

Datacentres Datacenters are buildings where multiple servers and communication gear are co-located because of their common environmental requirements and for physical security needs, and ease of maintenance. Barroso and Hölzle Luiz André Barroso and Urs Hölzle. The Datacenter as a Computer - An Introduction to the Design of Warehouse-Scale Machines. Morgan & Claypool Publishers, 2009 (120 pages). Note: a 2013 2 nd Edition of this book (156 pages) is also available with more Google-oriented updates. Most of the basic material in the 2009 is still worthwhile to study. 4

IT Architectural overview Server 5 Image (left) under CC license by MrLinsky on Wikimedia

Energy use at a datacentre Datacentre overhead Server consumption From Luiz André Barroso and Urs Hölzle, 2009, Data (Right chart) from one Google facility 2007.

Power and cooling systems 7 Graphic provided courtesy of DLB Associates

Power system components Primary switchgear Breakers for protection Transformers (10-20kV to 110-600V) Diesel generators Switched on in case of utility power failure Uninterruptible Power Supply (UPS) Batteries for short term energy provision Functionality Switch energy source between mains power (from utility) and power from Diesel generators Sustain system power with batteries during mains power failure Power feed conditioning 8

Power system components Power Distribution Units (PDUs) Break a higher voltage line into several circuits 200-480V line to many 110-220V circuits that feed the servers A ground short (in server or power supply) will only break one circuit Distribute energy to each rack Provide redundancy (A-side, B-side) so that with a power supply failure fast switching can take place 9

Cooling system Computer Room Air Conditioning (CRAC) Blows cold air under the floor plenum Cold air moves to front of server racks (cold aisle) Cold air flows through server racks Warm air is expelled in the back (warm aisle) 10

Cooling: operational range Datacentre cannot operate without cooling CRAC units cool the room's air Liquid coolant is pumped from chillers or cooling towers Coils are kept cool (12-14 ºC) with liquid coolant Warm air is pushed through the coils by fans Cold air (16-20 ºC) is moved to the floor plenum Air reaches the servers at 18-22 ºC 11

Free cooling Much more efficient than chillers Cool the coolant to much lower temperatures before reaching the chiller Cooling tower Glycolbased radiator Fans to push air from outside 12 Image (left) under CC license by Frobles on Wikimedia Image (right) under CC license by cbpowerindustrial on Flickr

Redundancy and reliability Redundancy for fault tolerance and during maintenance Applied to both power and cooling systems Configurations: N+1, N+2, 2N Type Availability Description Tier I 99.67% Single path for power & cooling. No redundancy (N) Tier II 99.74% Single path for power & cooling. Redundancy (N+1) Tier III 99.98% Tier IV 99.995% Tier Classification (ANSI/TIA 942) Multiple paths for power & cooling (only one active). Concurrently maintainable. Redundancy (N+1) Multiple active paths for power & cooling. Redundancy in both paths (min (N+1)) W.Pitt Turner IV, J.H.Seader, K.G.Brill. Tier classifications define site infrastructure performance, Uptime Institute, White Paper 13

Container-based datacentres Server racks, power distribution and heat exchange inside a container!! Highly efficient cooling High server density 14 Image from Wikimedia by user Sun Microsystem

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Seminar groups Datacentre visit 15

Sources of efficiency losses Power systems Element Losses Transformers 0.50% UPSs 7-12% Highly efficient UPSs 3% Low-voltage power (110-220V) cables 1-3% Cooling Fans that move cool and warm air Mix of cool and warm air during long paths Too low temperature selection 25-27 ºC better than traditional 20 ºC 16

Energy efficiency metrics Power Usage Effectiveness (PUE) Proposed by The Green Grid association Efficiency of the IT support infrastructure PUE= Total facility power Total IT equipment power Historic data: PUEs between 1.5 and 2.0 Google, Microsoft, Apple have reported PUEs around 1.1X C. Beladi. Green Grid datacenter power efficiency metrics: PUE and DCiE. White paper. 2008 17

Location matters One quarter of Singapore data centers have PUE higher than 3, Japan and Australia claim average PUE of 2.2 and 2.25 respectively (APAC datacenter survey, April 2013) Facebook Luleå: 1.08 (Computer Sweden, 7 Feb 2013) Image: https://www.facebook.com/luleadatacenter

Facebook live dashboard https://www.facebook.com/forestcitydatacenter/app_288655784601722

Energy efficiency metrics PUE has to be used carefully Example: Server fans in IT-PAC Microsoft data centre container module Facility power IT equipment power IT-PAC airflow management is improved Server fans are no longer required PUE increases Overall energy consumption reduced despite PUE increase Other aspects must be taken into account http://www.datacenterknowledge.com/archives/2011/01/31/microsoft-eliminates-server-fans-despite-pue-hit/ 20

Energy efficiency metrics Green Grid's Datacentre Performance Efficiency (DCPE) DCPE= Amount of computational work Total energy used Barroso and Hölze propose: DCPE = 1/PUE. 1/SPUE. Computation/Total energy to electronics Computing efficiency IT equipment efficiency Building facilities efficiency 21

Energy efficiency metrics Server Power Usage Effectiveness (SPUE) Efficiency of the IT infrastructure Losses in power supply, voltage regulator modules, server fans SPUE= Total server input power Total useful power Useful power Consumption of electronics directly involved in computation E.g. motherboard, disks, CPU, DRAM... Servers have SPUEs between 1.6 and 1.8 State of the art servers should be less than 1.2!!! 22

Energy efficiency metrics Total Power Usage Effectiveness (TPUE) Show efficiency of electromechanical overheads. TPUE= PUE SPUE Example: 2.0 PUE 1.6 SPUE TPUE= 2.0 1.6= 3.2 For each productive Watt another 2.2 W consumed!!! 23

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Seminar groups Datacentre visit 24

Load and energy efficiency Most of the time spent in no energy-efficient load regions Activity profile of 5000 Google servers in 6 months Image from Luiz André Barroso and Urs Hölzle. The Datacenter as a Computer 2009. 25

Load and energy efficiency Almost no time in idle state In low load there are several hundreds of queries Load spread out over all available servers Optimised for performance and/or availability Sustainable approach Concentrate load in a few servers Switch off unused servers But!!! More software complexity Energy for data distribution 26

Recall from lecture 2 Consumption proportional to the load Ideal linear function without constants 120 100 Energy (%) 80 60 40 20 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) Ideal energy proportional server Traditional server Traditional server data based on data from Barroso and Hölzle 2009. 27

Energy proportional computing Capacity to adapt consumption to load Device Dynamic power CPU 3.0x Memory 2.0x Disks 1.3x Network switches 1.2x More hardware improvements are required!!! Meanwhile only option is to switch off hardware!!! 28

Energy spent: revisited CPU a larger proportion of energy costs than that reported in 2009! Luiz André Barroso and Urs Hölzle. The Datacenter as a Computer, 2 nd Edition 2013

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Seminar groups Datacentre visit 30

ENERGY STAR Future specifications Program Requirements for Computer Servers 2.0 Currently first draft available Industry drive: Microsoft joins Will include active consumption Facebook to lead the Open as opposed to just idle consumption Computer Project on servers Computer Sweden, 30 Jan. 2014 http://blogs.technet.com/b/microsoft_blog/archive/2014/01/27/ microsoft-contributes-cloud-server-designs-to-the-open-compute-project.aspx Program Requirements for Datacenter Storage 1.0 establishes maximum consumption of storage products 31

EU Code of Conduct for Datacentres European action to reduce consumption of datacentres Best practices for datacentres operators V3.0 Guide (Feb 2011) Operators register and commit to their application Roles of applicant Participant Operator of datacentre or equipment in it Commitments Annual report of energy consumption Implementation of some of the best practices Endorser Support the initiative and participants http://re.jrc.ec.europa.eu/energyefficiency/html/standby_initiative.htm 32

EU Code of Conduct for Data Centres Scope of the best practices Datacentre utilisation, management and planning IT equipment and services Cooling Datacentre power equipment Other equipment Building Monitoring Best practice expected implementation Immediate During software install or update During new IT introduction or replacement During building of datacenter or retrofit Optional 33

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Seminar groups Datacentre visit 34

Seminar groups We have 56 students of which 50 registered in webreg 3 students had to be turned down, so make the best of the opportunity to attend the course! 35

Datacentre visit Currently discussing a visit at Ericsson Preliminary date: 10/3 afternoon Webreg will open for registering for the visit 36

Questions?