Citrix XenServer 5.6 OpenSource Xen 2.6 on RHEL 5 OpenSource Xen 3.2 on Debian 5.0(Lenny)



Similar documents
Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Using Intelligent Power Manager (IPM) & Intelligent Power Protector (IPP) on Virtual Desktop Infrastructure (VDI)

Eaton NetWatch v5.0 NetWatch on Microsoft Hyper-V server 2008 Installation and configuration guide

Eaton NetWatch NetWatch installation and configuration guide VMware ESX 3 Virtual architecture

How to install software on VMware ESXi 4.0/4.1

Network Shutdown Module V3 Extension of the User Manual for IBM BladeCenter architecture

Dell UPS Local Node Manager. User Guide. Dell.com

Eaton Intelligent Power Protector User s Guide / AI Eaton Intelligent Power Protector User s Guide

Thinspace deskcloud. Quick Start Guide

Getting Started with RES Automation Manager Agent for Linux

NetIQ Sentinel Quick Start Guide

Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures. Goliath Performance Monitor Installation Guide v11.

SGI NAS. Quick Start Guide a

Citrix XenClient 1.0

F-SECURE MESSAGING SECURITY GATEWAY

Integrating Eaton PRO Management Pack for Microsoft System Center Virtual Machine Manager 2008 v1.0 Page 2

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

Accops HyWorks v2.5. Quick Start Guide. Last Update: 4/18/2016

Installation Guide C-MOR Video Surveillance on XenServer from version 6.2

OnCommand Performance Manager 1.1

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Virtual Appliance Setup Guide

VMware vsphere 5 Quick Start Guide

Setting up an icap Server for ISG- 1000/2000 AV Support

Virtual Appliance Setup Guide

Acronis Backup & Recovery 11.5 Quick Start Guide

Rally Installation Guide

Managing Multi-Hypervisor Environments with vcenter Server

Virtualization Management the ovirt way

CA arcserve Unified Data Protection Agent for Linux

SA Citrix Virtual Desktop Infrastructure (VDI) Configuration Guide

Apache CloudStack 4.x (incubating) Network Setup: excerpt from Installation Guide. Revised February 28, :32 pm Pacific

Xen Virtualization: Xen (source) and XenServer

WhatsUp Gold v16.3 Installation and Configuration Guide

SA Citrix Virtual Desktop Infrastructure (VDI) Configuration Guide

NOC PS manual. Copyright Maxnet All rights reserved. Page 1/45 NOC-PS Manuel EN version 1.3

Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures. Goliath Performance Monitor Installation Guide v11.

F-Secure Messaging Security Gateway. Deployment Guide

Installation Guide for Citrix XenServer 5.5

Quick Start Guide for VMware and Windows 7

VMware vcenter Log Insight Getting Started Guide

simplify monitoring Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures

Konica Minolta s Optimised Print Services (OPS)

Interworks. Interworks Cloud Platform Installation Guide

Setting up Citrix XenServer for 2X VirtualDesktopServer Manual

Verax Service Desk Installation Guide for UNIX and Windows

Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual

XenDesktop Implementation Guide

Configuring Devices for Use with Cisco Configuration Professional (CCP) 2.5

Goliath Performance Monitor Prerequisites v11.6

Core Protection for Virtual Machines 1

simplify monitoring Environment Prerequisites for Installation Simplify Monitoring 11.4 (v11.4) Document Date: January

Version 3.8. Installation Guide

Installing and Configuring vcloud Connector

VMTurbo Operations Manager 4.5 Installing and Updating Operations Manager

Kaviza VDI-in-a-box Administration Guide Version 3.0 kaviza Inc. (

VMware vcenter Log Insight Security Guide

How to Configure Intel X520 Ethernet Server Adapter Based Virtual Functions on Citrix* XenServer 6.0*

SOA Software API Gateway Appliance 7.1.x Administration Guide

Web Application Firewall

Citrix XenServer Workload Balancing Quick Start. Published February Edition

XenApp 7.7 Deployment ISO. 5 th January 2016

SAM XFile. Trial Installation Guide Linux. Snell OD is in the process of being rebranded SAM XFile

13.1 Backup virtual machines running on VMware ESXi / ESX Server

Enterprise Manager. Version 6.2. Installation Guide

NMS300 Network Management System

EMC Data Domain Management Center

NSi Mobile Installation Guide. Version 6.2

Plexxi Control Installation Guide Release 2.1.0

Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1

StarWind iscsi SAN Software: Using with Citrix XenServer

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

This chapter explains a preparation for the use of RemoteControlService.

Virtual Managment Appliance Setup Guide

Syncplicity On-Premise Storage Connector

VMware vcenter Log Insight Getting Started Guide

Alinto Mail Server Pro

Getting Started with PRTG Network Monitor 2012 Paessler AG

PHD Virtual Backup for Hyper-V

Quick Start Guide FLIR Firmware Update Tool

WDM Security Guidelines

VELOCITY. Quick Start Guide. Citrix XenServer Hypervisor. Server Mode (Single-Interface Deployment) Before You Begin SUMMARY OF TASKS

Installing and Configuring vcenter Support Assistant

ARIS Server Installation and Administration Guide ARIS. Version Service Release 1

Load Balancing Trend Micro InterScan Web Gateway

VMWare Workstation 11 Installation MICROSOFT WINDOWS SERVER 2008 R2 STANDARD ENTERPRISE ED.

SonicWALL SRA Virtual Appliance Getting Started Guide

Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures. Goliath Performance Monitor Installation Guide v11.

Table of Contents. Online backup Manager User s Guide

VMware Server 2.0 Essentials. Virtualization Deployment and Management

PARALLELS SERVER BARE METAL 5.0 README

Smart Server Manager v1.2 Best Practices. Smart Server Manager v1.2 Best Practices Guide

RSA Authentication Manager 8.1 Virtual Appliance Getting Started

Setting up VMware Server v1 for 2X VirtualDesktopServer Manual

vsphere Upgrade vsphere 6.0 EN

Quick Start Guide for Parallels Virtuozzo

Virtual Web Appliance Setup Guide

Transcription:

Installing and configuring Intelligent Power Protector On Xen Virtualized Architecture Citrix XenServer 5.6 OpenSource Xen 2.6 on RHEL 5 OpenSource Xen 3.2 on Debian 5.0(Lenny) 1

Introduction... 3 1. Citrix Xen... 5 1.1. Citrix XenServer configuration... 6 1.2. Prerequisites to install IPP on Citrix XenServer 5.6 x86 machine:... 7 1.3. IPP Installation... 7 1.3.1. Hardware Architecture... 7 1.3.2. Network architecture... 7 1.3.3. Installation... 8 2. Xen on RHEL 5 and Debian 5.0 (Lenny)... 10 2.1. Xen Domain0 configuration... 11 2.2. Prerequisites to install IPP on Xen enabled on RHEL5 /Debian 5.0 (Lenny)... 11 2.3. IPP Installation... 11 2.3.1. Hardware Architecture... 11 2.3.2. Network architecture... 12 2.3.3. Installation... 13 3. Using IPP... 15 3.1. Step 1 (Access)... 15 3.2. Step 2 (Configuration)... 15 3.3. Step 3 (Operation)... 17 4. References... 18 5. Appendix A... 19 2

Introduction Eaton s Intelligent Power Protector discovers and supervises Eaton s UPSs and epdus connected across a network either by means of a card or proxy. It supervises the remote servers hosting the Intelligent Power Protector. It also provides local computer graceful shutdown. The IPP interface can be accessed remotely using a web browser. Our objective is to provide a virtualization support for Eaton s power protection software Intelligent Power Protector. So, the purpose of this document is to understand the installation and configuration of IPP on Xen virtualization environment. This has been tested upon different Xen environments. For more information, refer appendix A. Eaton provides 2 solutions for Citrix Xen that are illustrated on the previous architecture diagram: the first one provides graceful shutdown for Citrix Xen. IPP is installed on each Citrix Xen system. This solution doesn't require Xen Center management software (Refer to this document). the second one is for multiple Xen servers It provides following feature: 3

=> Xen server Remote maintenance to trigger VM Xen Motion. => Xen server Remote shutdown (with IPM 1.25) This solution is ideal for biggest infrastructures working through Xen Center This solution is described in IPM Xen Center Plug-in user manual (User Guide for configuration of IPM and XenCenter) Eaton provides following solution for Opensource Xen that is illustrated on the previous architecture diagram: It provides graceful shutdown for Xen. IPP is installed on each Xen system. This solution doesn't require Xen Center management software (Refer to this document). 4

1. Citrix Xen Citrix XenServer Architecture Domain1 Guest Domain2 Guest Domain3 Guest Xen Hypervisor Intelligent Power Protector Domain0 Guest Hardware Layer Memory Memory Network CPU Citrix XenServer Network USB Citrix XenCenter Eaton UPS 5

1.1. Citrix XenServer configuration Before installing Eaton IPP on Citrix XenServer host, following configurations have to be made: Hardware support for virtualization must be enabled on the Host. This is an option in the BIOS. It is possible your BIOS might have virtualization support disabled. Consult your BIOS documentation for more details. For automatic OS boot on startup, you must configure the physical machine to do the same. This setting is present in BIOS. For further information, see specific technical hardware documentation. In XenServer, to allow virtual machines to function properly, it is recommended that PV Tools (XenTools) should be installed on each virtual machine. For further information, see the appropriate XenServer Installation guide. XenCenter is an administrative console which monitors and manages XenServer hosts and guest machines. To make every virtual machine start automatically, select the check box (it is located in properties of every virtual machine) in XenCenter for the option Allow virtual machines to start and stop automatically with the system. 6

1.2. Prerequisites to install IPP on Citrix XenServer 5.6 x86 machine: 1. XenServer host having 5 MB free space. 2. IPP installation packages on XenServer Notes: 1. XenServer and XenCenter should be of same version. For compatibility issues, refer XenServer installation guide 2. To allow a graceful shutdown of the Virtual machines, you have to install PV Tools (XenTools) on each virtual machine. 3. In case of resource pools, if the slave machine goes down, then master machine will continue functioning. But if we shutdown master machine, all the guest machine in that pool will go down and the pool will be out of action until master is rebooted. 1.3. IPP Installation 1.3.1. Hardware Architecture The prerequisites for Intelligent Power Protector installation are described in the "Intelligent Power Protector User Manual" chapter: Installation Prerequisites. (http://pqsoftware.eaton.com/) For UPS systems compatibility, please refer to the chapter Appendix -> Compatibility List 1.3.2. Network architecture All hardware elements must have an operational network configuration that allows them to communicate freely with each other. Please make sure that the following TCP/UDP ports are enabled on XenSever Firewall Connections on tcp port 4679 and 4680 to enable a remote access for supervision and configuration through Web Browser. These ports are reserved at IANA (http://www.iana.org). Connections through TCP port 80. It must be opened as a destination port (for output) on the machine hosting Intelligent Power Protector. Configuration to enable communication between Intelligent Power Protector and NMC (Network Management Card) 7

iptables -I OUTPUT -p tcp --dport 80 -j ACCEPT iptables -I INPUT -p tcp --dport 4679 -j ACCEPT iptables -I INPUT -p tcp --dport 4680 -j ACCEPT iptables -I INPUT -p udp --dport 4679 -j ACCEPT iptables -I INPUT -p udp --dport 4680 -j ACCEPT iptables -I OUTPUT -p udp --dport 4679 -j ACCEPT iptables -I OUTPUT -p udp --dport 4680 -j ACCEPT service iptables save iptables-save service iptables save Configuration to enable communication between Intelligent Power Protector and Connect UPS BD/XSlot/PXGX2000: iptables -I OUTPUT -p tcp --dport 80 -j ACCEPT iptables -I INPUT -p tcp --dport 4679 -j ACCEPT iptables -I INPUT -p tcp --dport 4680 -j ACCEPT iptables -I INPUT -p udp --dport 2844 -j ACCEPT iptables -I INPUT -p udp --dport 2845 -j ACCEPT iptables -I OUTPUT -p udp --dport 2844 -j ACCEPT iptables -I OUTPUT -p udp --dport 2845 -j ACCEPT service iptables save iptables-save 1.3.3. Installation Download the latest version of Intelligent Power Protector for Linux from Eaton web site. During installation of this package on host it will automatically detect Linux Server. Note: With IPP version 1.20, you don t need to download a separate Xen shutdown script anymore. The Xen shutdown feature is now integrated in standard IPP 1.20 shutdown script. Download the latest version of Intelligent Power Protector, available on Eaton s website, in downloads section: See http://pqsoftware.eaton.com/ Then: > select Network solution. > select Linux as Operating System 8

Download Intelligent Power Protector v1.20, rpm Software Installer x86 «ipp-linuxx_xx_xxx-i386.rpm». Upload the package on your Xen environment To install IPP package: Install Intelligent Power Protector rpm package on XenServer by following command. rpm i ipp-linux-x_xx_xxx-i386.rpm For silent installation process, please refer to Intelligent Power Protector manual. At the end, connect to Intelligent Power Protector using your web browser by typing : http://<@ip-or-name-of-xenserver>:4679 (For a HTTP access) https://<@ IP-or-name-of-XenServer>:4680 (For a HTTPS access) Now Intelligent Power Protector interface will be displayed (refer to Chapter 3 Using IPP ) 9

2. Xen on RHEL 5 and Debian 5.0 (Lenny) Xen Architecture on RHEL 5 and Debian 5.0 Domain1 Guest Domain2 Guest Domain3 Guest RHEL or Debian + Xen Hypervisor Intelligent Power Protector Domain0 Guest Hardware Layer Memory Memory Network CPU Xen Hypervisor on Linux (RHEL/Debian) Network USB/ Serial (Debian) SSH Client Eaton UPS 10

2.1. Xen Domain0 configuration Before installing Eaton IPP on RHEL/Debian Lenny where Xen Domain0 is enabled, the following configurations have to be made: Hardware support for virtualization must be enabled on the host. This is an option in the BIOS. It is possible your BIOS might have virtualization support disabled. Consult your BIOS documentation for more details. For automatic OS boot on startup, you must configure the physical machine to do the same. This setting is present in BIOS. For further information, see specific technical hardware documentation. In order to allow windows virtual machines to function properly, it is recommended that GPL Para virtualized (PV) drivers should be installed on each windows virtual machine. 2.2. Prerequisites to install IPP on Xen enabled on RHEL5 /Debian 5.0 (Lenny) 1. Xen hypervisor (on RHEL/Debian) having minimum 5 MB free space. 2. IPP installation packages on RHEL/Debian. Notes: 1. To allow a graceful shutdown of guest virtual machines, you have to install GPL PV drivers on each virtual machine. 2. UPSs through RS232 connectivity will not be supported on RHEL5 as serial ports are used by Xen. 2.3. IPP Installation 2.3.1. Hardware Architecture The prerequisites for Intelligent Power Protector installation are described in the "Intelligent Power Protector User Manual" chapter: Installation Prerequisites. (http://pqsoftware.eaton.com/) For UPS systems compatibility, please refer to the chapter Appendix -> Compatibility List 11

2.3.2. Network architecture All hardware elements must have an operational network configuration that allows them to communicate freely with each other. Please make sure that the following TCP/UDP ports are enabled on XenSever/Xen hypervisor Firewall Connections on tcp port 4679 and 4680 to enable a remote access for supervision and configuration through Web Browser. These ports are reserved at IANA (http://www.iana.org). Connections through TCP port 80. It must be opened as a destination port (for output) on the machine hosting Intelligent Power Protector. Configuration to enable communication between Intelligent Power Protector and NMC (Network Management Card) iptables -I OUTPUT -p tcp --dport 80 -j ACCEPT iptables -I INPUT -p tcp --dport 4679 -j ACCEPT iptables -I INPUT -p tcp --dport 4680 -j ACCEPT iptables -I INPUT -p udp --dport 4679 -j ACCEPT iptables -I INPUT -p udp --dport 4680 -j ACCEPT iptables -I OUTPUT -p udp --dport 4679 -j ACCEPT iptables -I OUTPUT -p udp --dport 4680 -j ACCEPT service iptables save iptables-save service iptables save Configuration to enable communication between Intelligent Power Protector and Connect UPS BD/XSlot/PXGX2000: iptables -I OUTPUT -p tcp --dport 80 -j ACCEPT iptables -I INPUT -p tcp --dport 4679 -j ACCEPT iptables -I INPUT -p tcp --dport 4680 -j ACCEPT iptables -I INPUT -p udp --dport 2844 -j ACCEPT iptables -I INPUT -p udp --dport 2845 -j ACCEPT iptables -I OUTPUT -p udp --dport 2844 -j ACCEPT iptables -I OUTPUT -p udp --dport 2845 -j ACCEPT service iptables save iptables-save 12

2.3.3. Installation Download the latest version of Intelligent Power Protector for Linux from Eaton web site. Note: With IPP version 1.20, you don t need to download a separate Xen shutdown script anymore. The Xen shutdown feature is now integrated in standard IPP 1.20 shutdown script. Download the latest version of Intelligent Power Protector, available on Eaton s website, in downloads section: See http://pqsoftware.eaton.com/ Then: > select Network solution. > select Linux as Operating System For RHEL5 x86_64 Download Intelligent Power Protector v1.20, rpm Software Installer x86_64 for Red Hat «ipp-linux-x_xx_xxx-x86_64.rpm». For Debian Lenny Download Intelligent Power Protector v1.20, deb Software Installer x86_64 for Debian «ipp-linux-x_xx_xxx-x86_64.deb». Upload the package on your Xen environment To install IPP package: For RHEL rpm i ipp-linux-x_xx_xxx-i386.rpm For Debian dpkg i ipp-linux-x_xx_xxx-i386.deb 13

For silent installation process, please refer to Intelligent Power Protector manual. At the end, connect to Intelligent Power Protector using your web browser by typing : http://<@ip-or-name-of-xenserver>:4679 https://<@ IP-or-name-of-XenServer>:4680 (For a HTTP access) (For a HTTPS access) If because of systems setting, file execute permission gets changed. You need to give execute permissions to Xen shutdown script. Now Intelligent Power Protector interface will be displayed. (refer now to next Chapter) 14

3. Using IPP After IPP installation, follow these 3 steps to use IPP. For more information about IPP refer to the IPP User Manual 3.1. Step 1 (Access) Remote access (for XenServer) From a remote machine, you can type the following URL in a Web browser https://<name or IP address of Server hosting IPP>:4680/ Or http://<name or IP address of Server hosting IPP>:4679/ In SSL mode, accept the certificate (by clicking on Yes) (Enter admin as Login / admin as Password and click on the Login button) 3.2. Step 2 (Configuration) When started, the application automatically performs a Quick scan. Using the Quick scan operation, you will discover: =>Serial line connected UPSs (RS232 or USB) The discovered UPS connected through (RS232 or USB) is automatically assigned as the Power source (the Status icon is Green ) => Networked UPSs through broadcast within a few seconds (Network Management Cards Network-MS (ex 66102) 15

The discovered UPS connected through (Network) are not automatically assigned as the Power source (You have to select the node and click on the button Set as Power Source the icon becomes Green ) The discovered nodes are displayed in Settings Auto Discovery For the other nodes, please perform the discovery based on IP address ranges (Range scan) Using the Range Scan operation you will discover the nodes that are outside of the Network segment and nodes that are not compatible with the Quick scan feature. In the Settings Shutdown page, assign the IP address of the UPS that powers the local Computer. With IPP 1.20 version the standard shutdown feature now integrates XEN shutdown. Please refer to IPP user manual for shutdown settings if needed. In the Settings User List page, assign the access rights through login and password 16

3.3. Step 3 (Operation) The Views Power Source menu item (optional) allows you to supervise the current state of the UPS that powers the server running Intelligent Power Protector The Events Event List view allows you to view the device events. 17

4. References 1. http://www.xen.org/files/marketing/whatisxen.pdf - 2. http://www.howtoforge.com/virtualization-with-xenserver-5.5.0 3. http://docs.vmd.citrix.com/xenserver/4.0.1/reference/ch05s04.html Copyrights Eaton and Eaton Corporation are trade names, trademarks, and/or service marks of Eaton Corporation or its subsidiaries and affiliates. VMware is a registered trademark of VMware, Inc. Xen, XenSource, XenEnterprise, XenServer, XenExpress, XenCenter and logos are either registered trademarks or trademarks of XenSource, Inc. in the United States and/or other countries. All other company or product names are used for informational purposes only and may be trademarks are property of their respective owners. 18

5. Appendix A Tested Setup: The installation and configuration of IPP has been tested upon following Xen environment: 1. Citrix XenServer 5.6 x86 2. RedHat 5 x86_64 3. Debian 5.0 (Lenny) x86_64 19

20