FCD-E1E Managed E1 and Fractional E1 Access Device



Similar documents
FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Optimux-134, Optimux-125

Optimux-34, Optimux-25

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Optimux-134, Optimux-125

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

IPmux-1E TDM Pseudowire Access Gateway

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

WEB RANger-II Internet Access Router

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

DXC-8R/10A/30 Multiservice Access Nodes

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

DXC Family. Multiservice Access Node FEATURES

TDMoEthernet. Description

Loop-IP6702 TDMoEthernet

Loop-IP6700 TDMoEthernet

IPmux-155L Hub-Site Pseudowire Access Gateway

Loop-IP6700 TDMoEthernet

FOM-5A, 6A. Asynchronous Fiber Optic Modem

IPmux-16L Hub-Site Pseudowire Access Gateway

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node

Egate-100 Gigabit Ethernet over TDM Aggregation Gateway

ORION TELECOM NETWORKS INC. T1

LA-110. Advanced Integrated Access Device FEATURES

Loop-V4300 MINI DACS E1/ T1 CONVERTER

ETX-204A Carrier Ethernet Demarcation Device

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

T3 Mux M13 Multiplexer

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

IPmux-216 TDM Pseudowire Access Gateway

Chapter 4 T1 Interface Card

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Loop-IP6510 Multiple WAN Router/Bridge

G.703 Fractional T1 Access Unit. User Guide

Long Range Ethernet Extender

Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

Connecting Serial Interface Cards to a Network

1. Overview. 2. F-bit Utilization

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Adtech Data Link Simulators.

N560 series H/W Installation Guide

OPERATION MANUAL INSTALLATION AND DXC-4. E1/T1 Grooming Device. Version 1.0. Innovative Access Solutions

F2400 FOM II Series Fiber Optic Modem Technical Manual

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

One Port Serial Server Users Manual Model ESP901, ESP901E

Cable Pinouts. SRP I/O Module

24-Port Channelized E1/T1 Line Card Overview

Airmux-200 Wireless Broadband Multiplexer

VALIANT COMMUNICATIONS LIMITED

Ethernet Link SGI-2424

IntraCore Series 16-port Gigabit Managed Switches Layer 2

MPX100 Intelligent Ethernet Test Probe

Chapter 2 - The TCP/IP and OSI Networking Models

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Optimux-XLT1. Multiple T1 and Ethernet Multiplexer Installation and Operation Manual. Notice

VePAL MX300. Platform Highlights. Key Features. 10GbE LAN/WAN and Gigabit Ethernet and Fast Ethernet Test Set. Metro Expert

TrueAlarm Fire Alarm Systems

Cisco Channelized T1/E1 and ISDN PRI Modules

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

DataSMART 681, 696 and 698

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

SHDSL LAN EXTENDER H301A. User Manual

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

VALIANT COMMUNICATIONS

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Cable Specifications and Information

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

INSTALLATION and OPERATION MANUAL

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

CHRONOS. Ethernet Demarcation. Smart Access Network Device. Features. Introduction

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

IPmux-155L Version 1.0B

3500/22M Transient Data Interface

MODBUS TCP to RTU/ASCII Gateway. User s Manual

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

TP-LINK TECHNOLOGIES CO.,LTD. Website ADD FI.3,Bldg.R1-B.High-Tech Industrial Park,Shenzhen

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

FarSync T2Ue. A 2 port PCI Express synchronous communications adapter

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

BTM10 Series Transmission Analyzer

Transcription:

Where to buy > See the product page > Data Sheet FCD-E1E E1 main link and sublink supporting both framed and unframed signals TDM multiplexer enables Ethernet, Sub-E1 and Serial Services over E1 One data port with selectable sync data rates of n 64 kbps Optional sub-e1 drop-and-insert port Optional Ethernet 10/100BaseT bridge (with or without VLAN support) Inband management with SNMP agent FCD-E1E is a managed access unit that converts rates and interfaces for E1 and fractional E1 services. FCD-E1E features a serial n 64 kbps data user interface, and/or an Ethernet LAN interface to allow LAN-to-LAN connectivity over TDM media. The unit interconnects with RAD s modular DXC (DACS) products and E1 equipment from other vendors, to support multilink star applications such as access to SDH networks, FCD, and Megaplex units. The E1 interface is compatible with virtually all carrier-provided E1 services and meets ITU recommendations G.703, G.704, G.706, G.732, G.823, and G.826. The Access Company

FCD-E1E FCD-E1E supports both 2 and 16 frames per multiframe, with or without CRC-4. The E1 interface also accepts a 2048-kbps data stream and converts it to an ITU-T Rec. G.703 unframed signal for transport over the E1 main link and sublink. Line code is HDB3/AMI. The integral LTU ensures a range of up to 2 km (1.2 miles) and is software selectable. The optional sub-e1 port can be configured to work without CRC-4, while the E1 main link is working with CRC-4. E1 equipment not supporting CRC-4 can thus connect to an E1 network that does work with CRC-4. Bypassing the sub-e1 port to the main link ensures uninterrupted service to the sub-e1 port and full immunity to hardware and power failure. The unit can be configured to assign data from the data port into consecutive timeslots or the user can assign timeslots manually. Multiple clock source selection ensures maximum flexibility. Timing for the E1 main link and sublink may come from the recovered receive clock, an internal oscillator, or the data port. An optional 10/100BaseT Ethernet port can be ordered for management, with or without bridge functionality. Note: The devices originally ordered with management only functionality (/UTPM) can be upgraded to the /UTP (bridge and management) functionality by ordering a special software license key (see Ordering). Front-panel LEDs indicate power, alarms, and diagnostic loopback operation. Rear panel LEDs on the E1 interfaces indicate local and remote sync loss. Rear-panel LEDs on the optional Ethernet port indicate link integrity and activity. FCD-E1E is available in two models: Plastic enclosure (FCD-E1E) Metal enclosure with LCD and push-buttons on the front panel (FCD-E1E/L). Both enclosures can be mounted alone or in pairs in a 19-inch rack using RAD s optional rack mount kits (see Ordering). Figure 1. Point to Point Ethernet, Data and Fractional E1 over E1

Data Sheet USER INTERFACES The FCD-E1E unit features the following user interfaces: Serial data interfaces: V.24/RS-232, V.35, V.36/RS-449, RS-530, X.21 Ethernet 10/100BaseT LAN interface. The synchronous data ports of FCD-E1E operate in the following clock modes: DCE: FCD-E1E provides both transmit and receive clocks to the user equipment, with optional sampling of the incoming data with an inverted clock DTE1: FCD-E1E provides the receive clock, while the transmit clock is provided by the attached user equipment (not for X.21 and V.24) DTE2: The remote user equipment provides both transmit and receive clocks (not for X.21 and V.24). The optional bridge port is a standard 10/100BaseT half/full-duplex port featuring autonegotiation and automatic crossover support. Its interface supports VLAN frames, automatic learning and aging. The bridge port transparently connects FCD-E1E to remote LANs over E1 links. It filters Ethernet frames and forwards only frames that are destined for the WAN. MANAGEMENT AND MAINTENANCE Status and diagnostic information is defined, configured, and monitored using any of the following methods: Menu-driven management using the front panel LCD with three pushbuttons (metal enclosure only) ASCII terminal connected to the async control port Telnet (only with optional Ethernet port) RADView element manager (only with optional Ethernet port). Up to 2048 time-stamped alarms can be retrieved through the supervision terminal. Maintenance capabilities include user-activated local and remote loopbacks on the E1 main link, sublink, and data port. The user can activate a BER test on the main link or sublink. E1 network statistics are stored in memory, according to IETF RFC4805. Statistical information can be retrieved locally through the control port. FCD-E1E performs VLAN tagging and priority labeling according to IEEE 802.1p&Q (enhanced QoS, supporting strict/weighted fair queue mechanism, with 802.1p/DSCP/IP Precedence priority). The unit performs rate limiting (egress and ingress).

FCD-E1E Specifications E1 MAIN LINK AND SUBLINK Framing 256N (no MF, CCS) 256N (no MF, CCS) with CRC-4 256S (TS16 MF, CAS) 256S (TS16 MF, CAS) with CRC-4 Unframed Bit Rate 2.048 Mbps Line Code AMI/HDB3 Zero Suppression HDB3 Line Impedance 120Ω, balanced 75Ω, unbalanced Transmit Timing Locked to the system clock Signal Level Receive: 0 to 10 db short haul 0 to 36 db long haul Transmit: ±3V (±10%), balanced ±2.37V (±10%), unbalanced Jitter Performance: as per ITU G.823, ETSI TBR-12 and TBR-13 Connectors RJ-45, 8-pin, balanced Two BNC coaxial, unbalanced Compliance ITU G.703, G.704, G.706, G.732, G.823, G.826 Performance Monitoring Local support of CRC-4 Full statistical diagnostics according to RFC-2495 Figure 2. Managed V.35 to E1 Converter

Data Sheet DATA PORTS Connectors D-type, 25-pin, RS-530, female (converted via adapter cables to V.35, X.21, V.36/RS-449 or V.24/RS-232) Data Rate n 64 kbps (n=1 to 2) for V.24 port n 64 kbps (n=1 to 32) for other ports Clock Modes DCE: Rx and Tx clock to user device DTE1: Tx clock to user device; Rx clock from user device (not for X.21 and V.24) DTE2: Rx and Tx clock from user device (not for X.21 and V.24) Control Signals CTS follows RTS or constantly ON, soft-selectable DSR constantly ON (except during the remote main link loopback) DCD constantly ON (except during the loss of sync on main link) ETHERNET BRIDGE PORT Compliance IEEE 802.3, 802.3u, 802.1p&Q Interface and Connector 10/100BaseT (UTP) with shielded RJ-45 Data Rate 10 Mbps or 100 Mbps, full or half-duplex Maximum Frame Length 1800 bytes LAN Table 2048 MAC addresses Throughput 4,207 pps Latency* 0.51 ms (64-byte frame size) *FCD-E1E to FCD-E1E, 1.6M LAN rate Delay 4.437 ms for 1 Mbps (bidirectional, 1518 byte frame size) Buffer 320 frames Line Code 10BaseT: Manchester 100BaseT: MLT3 WAN Protocol HDLC

FCD-E1E MANAGEMENT PORTS CONTROL DCE Port Interface: RS-232 Connector: 9-pin D-type, female Format: asynchronous Baud rate: 9.6 115.2 kbps, Character: 8-bit no parity Ethernet Port (optional) Interface: 10/100BaseT Connector: RJ-45 DIAGNOSTICS Main E1 link Local loopback Remote loopback BER test Sublink Local loopback Remote loopback BER test Data Port Local loopback Remote loopback GENERAL System Clock Internal clock: ±32 ppm Loopback timing: ±100 ppm External timing from data port: ±100 ppm Timeslot Allocation Consecutive (bundled) User-defined Indicators General: PWR (green) TST (yellow) ALM (red) Main/sub-E1: LOC SYNC LOSS (red) REM SYNC LOSS (red) Ethernet: LINK (green) Ethernet link status ACT (yellow) Ethernet activity status Physical Plastic enclosure: Height: 43.7 mm (1.7 in) Width: 217 mm (8.5 in) Depth: 170 mm (6.7 in) Weight: 0.5 kg (1.1 lb) Metal enclosure: Height: 43.7 mm (1.7 in) Width: 215.5 mm (8.48 in) Depth: 152.7 mm (6.0 in) Weight: 0.7 kg (1.5 lb) Power AC/DC: 100 to 240 VAC, -48 to -60 VDC, nominal power consumption: 5W max. Environment Temperature: 0 C to 50 C (32 F to 122 F) Humidity: Up to 90%, non condensing

Data Sheet Table 1. FCD Comparison Table Features FCD-E1 FCD-E1L FCD-E1LC/T1LC FCD-E1E FCD-E1A Total user ports 3 2 3 2 3 Interface types RS-530, V.35, V.36, X.21, Sub-E1 RS-530, V.35, V.36, X.21, Ethernet bridge (10/100BaseT with VLAN support) RS-530, V.24, V.35, V.36, X.21, Ethernet Bridge (10/100BaseT with VLAN support), Sub-E1/T1 RS-530, V.35, V.36/RS-449, X.21, V.24/RS-232, Ethernet Bridge (10/100BaseT with VLAN support), Sub-E1 RS-530, V.35, V.36/RS-449, X.21, Sub-E1 E1/T1 line type Copper Copper Copper Copper Copper LCD panel Auto-configuration SNMP management Interoperability Megaplex, DXC Megaplex, DXC Megaplex, DXC Megaplex, DXC Megaplex, DXC ETH out-of-band for management E1 bypass ETH performance VLAN transparent VLAN transparent VLAN priority tagging (802.1p/Q) VLAN transparent

Data Sheet FCD-E1E Ordering STANDARD CONFIGURATIONS FCD-E1E/2E1/UTP/V35/L FCD-E1E/2E1/UTPM/V35/L SPECIAL CONFIGURATIONS FCD-E1E/@/+/&/* Legend @ TDM interface: 1E1 1 balanced E1 as uplink 1E1CX 1 unbalanced E1 as uplink 2E1 Balanced E1 and sub E1 2E1CX Unbalanced E1 and sub E1 + Ethernet interface (Default=no Ethernet): UTP 10/100BaseT Ethernet port (bridge and management) UTPM 10/100BaseT Ethernet port (management only) & Data port interface: V35 V.35 V36 V.36/RS-449 530 RS-530 X21 X.21 V24 V.24/RS-232 (asynchronous) * Enclosure (Default=plastic): L Metal, with LCD FCD-E1E/SW/$ Software upgrade pack for enabling bridge and management services on the Ethernet port. Note: When this option is ordered, RAD sends a code for activating the required feature. SUPPLIED ACCESSORIES Power cord AC/DC adapter plug CBL-HS2/*/# Adaptor cables for DB-25 channel connectors, for operation in the DCE, DTE1, and DTE2 clock modes. Cable length is 2m (6 ft). Legend * Interface, clock mode: V/1 34-pin V.35, DCE V/2 34-pin V.35, DTE1 V/3 34-pin V.35, DTE2 R/1 37-pin V.36/RS-449, DCE R/2 37-pin V.36/RS-449, DTE1 R/3 37-pin V.36/RS-449, DTE2 X/1 15-pin X.21, DCE # Connector: F female M male OPTIONAL ACCESSORIES CBL-DB9F-DB9M-STR Control port cable CBL-RJ45/2BNC/E1 RJ-45 to BNC adaptor cable RM-33-2 Hardware kit for mounting one or two FCD-E1E units into a 19-inch rack RM-35/@ Kit for mounting 1 or 2 FCD-E1E/L units (metal enclosure) in a 19-inch rack Legend @ Rack mount kit: P1 Mounting one unit P2 Mounting two units 519-100-06/11 Specifications are subject to change without prior notice. 1988 2011 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders. International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@radusa.com www.rad.com Order this publication by Catalog No. 803852 The Access Company