Diesel Engine Analyser Kit

Similar documents
GfK PURCHASING POWER INTERNATIONAL

Highly efficient flue gas analyzer

NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter

The testo 340 What makes it The Ultimate Combustion Tuner?

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

Measuring Instruments for Flue Gas and Emissions

Appendix 1: Full Country Rankings

CONTENTS

relating to household s disposable income. A Gini Coefficient of zero indicates

VISA AND RESIDENCE PERMIT FOR GERMANY FOR INTERNATIONAL STUDENTS AND Ph.D. STUDENTS

QuickSpecs. HP Wireless Keyboard and Mouse. Models

World Consumer Income and Expenditure Patterns

Updated development of global greenhouse gas emissions 2013

UNHCR, United Nations High Commissioner for Refugees

Logix5000 Clock Update Tool V /13/2005 Copyright 2005 Rockwell Automation Inc., All Rights Reserved. 1

The big pay turnaround: Eurozone recovering, emerging markets falter in 2015

Proposal from the Philippines for amendments to the Kyoto Protocol

Global AML Resource Map Over 2000 AML professionals

Accuracy counts! SENSORS WITH ANALOG OUTPUT

DIRECT MARKETING STRATEGY. Web & Software Development Services

Employee eligibility to work in the UK

COMMUNICATION FROM THE COMMISSION

Fact sheet: The Kyoto Protocol

1. Perception of the Bancruptcy System Perception of In-court Reorganisation... 4

Size and Development of the Shadow Economy of 31 European and 5 other OECD Countries from 2003 to 2015: Different Developments

Comprehensive emissions per capita for industrialised countries

FDI performance and potential rankings. Astrit Sulstarova Division on Investment and Enterprise UNCTAD

Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017

ERASMUS+ MASTER LOANS

Overview menu: ArminLabs - DHL Medical Express Online-Pickup: Access to the Online System

steam & condensate management solutions STAPS Wireless steam trap monitoring

Digital TV Research. Research-v3873/ Publisher Sample

The Guardianship Service

Contact Centers Worldwide

Replacement Migration

Global Economic Briefing: Global Inflation

States Parties to the 1951 Convention relating to the Status of Refugees and the 1967 Protocol

Senate Committee: Education and Employment. QUESTION ON NOTICE Budget Estimates

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Report on Government Information Requests

INTERNATIONAL TRACKED POSTAGE SERVICE

Analysis of statistics 2015

Clinical Trials. Local Trial Requirements

Know the Facts. Aon Hewitt Country Profiles can help: Support a decision to establish or not establish operations in a specific country.

ERASMUS+ MASTER LOANS

Credit transfer to Customer account with AS "Meridian Trade Bank" EUR, USD free of charge * Other countries currency information in the Bank

International Financial Reporting Standards

Region Country AT&T Direct Access Code(s) HelpLine Number. Telstra: Optus:

With data up to: May Monthly Electricity Statistics

Building on +60 GW of experience. Track record as of 31 December 2013

Evolution of EU exports and imports of goods with CELAC, (in billion)

Chapter 4A: World Opinion on Terrorism

Global Network Access International Access Rates

Global Dialing Comment. Telephone Type. AT&T Direct Number. Access Type. Dial-In Number. Country. Albania Toll-Free

International Call Services

Energy Briefing: Global Crude Oil Demand & Supply

SunGard Best Practice Guide

Energy prices in the EU Household electricity prices in the EU rose by 2.9% in 2014 Gas prices up by 2.0% in the EU

U.S. Trade Overview, 2013

Reporting practices for domestic and total debt securities

European Research Council

Enterprise Mobility Suite (EMS) Overview

INTERNATIONAL TRADEMARK REGISTRATION UNDER THE MADRID PROTOCOL

Ninth United Nations Survey of Crime Trends and Operations of Criminal Justice Systems POLICE

Pan- European region

Consolidated International Banking Statistics in Japan

Planned Healthcare in Europe for Lothian residents

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Labour Force Survey 2014 Almost 10 million part-time workers in the EU would have preferred to work more Two-thirds were women

PF2.3: Additional leave entitlements for working parents

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014

Bangladesh Visa fees for foreign nationals

AMADEUS: Analyse MAjor Databases from EUropean Sources - A financial database of 4 million European companies, including Eastern Europe MODULE.

Brochure More information from

Report on Government Information Requests

Business Phone. Product solutions. Key features

Exercise 39. The Euro. At the end of this exercise you will:

International Hints and Tips

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

PLAN PRICE GUIDE Allowance 50GB Data, unlimited minutes, unlimited texts, inclusive Roaming in selected countries 1,2,

Culture in the Cockpit Collision or Cooperation?

Table 1: TSQM Version 1.4 Available Translations

ADVOC. the international network of independent law firms

How To Calculate The Lorenz Curve

Dial , when prompted to enter calling number, enter American Samoa Number can be dialed directly Angola 0199

THE WORLD S LEADING CAR DESIGN MAGAZINE

Animal Tissues Update on Requirements September BSI Healthcare Roadshow

EN ISO Safety of machinery Risk assessment. Sicherheit von Maschinen Risikobeurteilung Teil 1: Leitsätze (ISO :2007)

Multifunction HVAC and IAQ Meter

The World Market for Medical, Surgical, or Laboratory Sterilizers: A 2013 Global Trade Perspective

Jabra LINK 220 Jabra LINK 220a

NOMADIX, INC Nomadix Premium Support Policy

Waste. Copenhagen, 3 rd September Almut Reichel Project Manager Sustainable consumption and production & waste, European Environment Agency

ENTERING THE EU BORDERS & VISAS THE SCHENGEN AREA OF FREE MOVEMENT. EU Schengen States. Non-Schengen EU States. Non-EU Schengen States.

NetFlow Feature Acceleration

World Solution Provider

GE Grid Solutions. Providing solutions that keep the world energized Press Conference Call Presentation November 12, Imagination at work.

Visa Information 2012

Transcription:

Diesel Engine Analyser Kit Ideal for underground mining applications Kit includes 0632 3340 Testo 340 (Including O2 Sensor) 0393 1100 CO measuring cell, 0 to 10,000ppm 0393 1150 NO measuring cell, 0 to 3,000ppm 0393 1200 NO2 measuring cell, 0 to 500ppm 0600 7555 Engine Probe w/o pre-filter, Hose length 4m, shaft 335mm 0600 8894 Type K TC, Length 430mm, Cable Length 4m 0554 1096 Switching Power Supply 6,3VDC, 2000mA 0516 3400 Transport case 0554 0549 Testo Fast Printer 0554 3334 PC Software testo 335 EasyEmission CO NO N S Measuring range extension for unrestricted at high gas concentrations Flue gas analysis with up to 4 gas s freely configurable Large selection of probes Bluetooth interface Convenient data management TÜV-tested /EN norm The handy, easy-to-operate emission measuring instrument testo 340 is the right tool for many different emission s. The compact design and the reliable technology make it the ideal measuring instrument for commissioning, service and maintenance work and in test s on industrial burners, stationary industrial engines, gas turbines and thermal processes. The unique measuring range extension allows unrestricted s to be carried out even at high gas concentrations. The testo 340 is equipped with an O2 as standard. Three further gas s can be configured individually, in order to be able to adapt the instrument optimally to the respective task.

Product properties Automatic protection at high gas concentrations Thanks to the automatic measuring range extension, the measuring range of your CO,, NO, or S is extended 5-fold. The is placed under no greater strain at high gas concentrations than at low concentrations. The automatic protection protects the from overload without terminating the. Optionally, the measuring range of all s in the instrument can be simultaneously extended by a factor of 2. Measurement up to e.g. max. 50,000 ppm (CO), or max. 20,000 ppm (NO), or max. 25,000 ppm (S ), without overloading the. Space for 4 gas s testo 340 is fitted with an as standard. Three additional toxic gas s such as CO,, NO,, N oder S can be selected by the user. This guarantees highest flexibility when adapting to changing applications and jobs. The can be changed or upgraded in an additional gas parameter by the user directly on-site without time-consuming test gas adjustment. Simply select, change and add the gas s required at any time! For this purpose, select from these seven pre-calibrated gas s: 1) N 2) S 3) 4) 5) NO 6) CO 7) (standard) Convenient data management with "easyemission" Data can be read out, easily processed, filed and managed using the "easyemission" software: Advantages of easyemission Readings are shown in table or graph form User-defined spacing (from one / second to one / hour) Online s via BLUETOOTH wireless transmission or USB connection Customer and application-specific protocols Data structure and information can be transmitted from computer to analyzer All instrument configurations and settings can be easily carried out with easyemission Direct transmission to Excel and pdf formats Easy implementation of individual formulae for your own calculations Calculation of fuel factors when using customer-specific fuels

Large selection of flue gas sampling probes Different probe shaft lengths, diameters and temperature ranges ensure high flexibility for all applications. To change, the probe shaft is simply attached to the probe handle and engages. Special flue gas probes for industrial engines are designed for positive pressure at the site, making s possible even in the toughest conditions. In addition, modular industrial probes are available for rugged process conditions. Ready to operate immediately The highly robust fast-action probe coupling for all gas paths eliminates any confusion. The indestructible gas sampling hose cannot be bent, can be extended up to 7.8 m and saves space. The probe can remain positioned in the flue gas during the zeroing phase of the gas s. The calibration phase of testo 340 is finished after only 30 seconds. Wireless transmission* * Country permits BLUETOOTH wireless transmission, see Technical Data on page 8. Wireless readout, transmission and printing of readings Wireless connection via Bluetooth 2.0 to Testo BLUETOOTH printers and direct communication to notebook/pc over a distance of up to 10 m (free field) are features of the new testo 340 option. Readings and configurations are transmitted wirelessly to your notebook/pc for storage and analysis. Print data is transmitted wirelessly to the printer by infrared interface (visual contact required) or by new BLUETOOTH wireless transmission. This saves time since the analyzer is ready for use again immediately following data transmission. Measurement gas pump The automatically controlled gas pump built into testo 340 is the ideal solution for typical situations which arise when measuring flue gas such as negative or positive pressure (from -200 to +50 mbar). Pump flow is automatically kept constant. Integrated condensate trap The Testo design eliminates the possibility of condensation accumulating in the actual gas. The testo 340 warns if the condensation trap needs to be emptied. Large selection of probes 18 standard fuels and 10 additional user-defined fuels can be adapted specifically to each application.

Technical data Measuring range Accuracy ±1 digit Resolution 0 to 25 Vol. % ±0.2 Vol. % 0.01 Vol. % Adjustment time t 90 20 sec CO (H 2 0 to 10.000 ppm ±10 ppm or ±10% of mv (0 to 200 ppm) 1 ppm 40 sec 0 to 500 ppm ±20 ppm or ±5% of mv (201 to 2.000 ppm) ±10% of mv (2.001 to 10.000 ppm) ±2 ppm (0 to 39.9 ppm) 0.1 ppm 40 sec (H 2 ±5% of mv (remaining range) X X data corresponds to 20 C ambient temperature. Additional temperature coefficient 0.25% of reading/k. NO 0 to 4.000 ppm ±5 ppm (0 to 99 ppm) 1 ppm 30 sec ±5% of mv (100 to 1.999 ppm) ±10% of mv (2.000 to 4.000 ppm) 0 to 300 ppm ±2 ppm (0 to 39.9 ppm) ±5% of mv (remaining range) 0.1 ppm 30 sec N * 0 to 500 ppm ±10 ppm (0 to 199 ppm) ±5% of mv (remaining range) S * 0 to 5.000 ppm ±10 ppm (0 to 99 ppm) ±10% of mv (remaining range) Temperature meas. Probe type Type K (NiCr-Ni) Draught Differential pressure Absolute pressure Derived parameters -40 to +1.200 C ±0.5 C (0 to +99 C) ±0.5 % of mv (remaining range) -40 to +40 hpa ±0.03 hpa (-2.99 to +2.99 hpa) ±1.5 % of mv (remaining range) -200 to 200 hpa ±0.5 hpa (-49.9 to 49.9 hpa) ±1.5 % of mv (remaining range) 0.1 ppm 40 sec 1 ppm 40 sec 0.1 C 0.01 hpa 0.1 hpa 600 to +1.150 hpa ±10 hpa 1 hpa Efficiency 0 to 120 % 0.1 % Flue gas loss 0 to 99.9 % 0.1 % Exhaust gas dewpoint 0 to 99.9 C 0.1 C C 0 to C max. ±0.2 Vol. % 0.1 Vol. % 40 sec (Calculated from ) *To avoid absorption, a maximum duration of 2 hours should not be exceeded. Country permits BLUETOOTH wireless transmission for testo 340 The BLUETOOTH radio module used by Testo is permitted for the following countries and may only be used in those countries, i.e. the BLUETOOTH wireless transmission may not be used in any other country! Europe including all EU member states Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden and Turkey European countries (EFTA) Iceland, Liechtenstein, Norway, Switzerland Non-European countries Canada, USA, Japan, Ukraine, Australia, Columbia, El Salvador, Mexico, Venezuela, Ecuador, New Zealand, Bolivia, Dominican Republic, Peru, Chile, Cuba, Costa Rica, Nicaragua, Korea, Belarus.

Technical data Measuring range extension Single dilution, factor 5 (standard) Measuring range Accuracy Resolution CO (H 2 700 ppm to 50.000 ppm ±10 % of mv (additional error) 1 ppm (H 2 300 ppm to 2.500 ppm ±10 % of mv (additional error) 0.1 ppm NO 500 ppm to 20.000 ppm ±10 % of mv (additional error) 1 ppm 150 ppm to 1.500 ppm ±10 % of mv (additional error) 0,1 ppm S 500 ppm to 25.000 ppm ±10 % of mv (additional error) 1 ppm Dilution of all s, factor 2 (option, Part no. 0440 3350) When measuring range extension switched on, over all s: 0 to 25 Vol.% ±1 Vol.% additional error (0 to 4.99 Vol.%) ±0.5 Vol.% additional error (5 to 25 Vol.%) 0.01 Vol.% CO (H 2 700 ppm to 20.000 ppm ±10 % of mv (additional error) 1 ppm (H 2 300 ppm to 1.000 ppm ±10 % of mv (additional error) 0.1 ppm NO 500 ppm to 8.000 ppm ±10 % of mv (additional error) 1 ppm 150 ppm to 600 ppm ±10 % of mv (additional error) 0.1 ppm N 200 ppm to 1.000 ppm ±10 % of mv (additional error) 0.1 ppm S 500 ppm to 10.000 ppm ±10 % of mv (additional error) 1 ppm General technical data Memory Maximum Per folder Per site 100 folders Max. 10 sites Max. 200 logs The max. number of logs is determined by the number of folders or sites Display Power supply Housing material Protection class Graphic display 160 x 240 pixels Battery block 3.7 V / 2.4 Ah Mains unit 6.3 V / 2 A TPE PC IP40 User-defined fuels Regulated diaphragm pump Pump flow Hose length Max. pos. press./flue gas Max. neg. press./flue gas 10 user-defined fuels incl. test gas as fuel 0.6 l/min (regulated) max. 7.8 m (corresponds to two probe hose extensions) +50 mbar -200 mbar Warranty Analyzer Rech. batt. Sensors 2 years (excluding working parts, e.g. s, replacement filter) 1 year CO, NO,,, N, S : 1 year : 1.5 years Weight 960 g Dimensions 283 x 103 x 65 mm Storage temperature -20 to +50 C Operating temperature -5 to +50 C

PortableGasDetection BW TechnologiesbyHoneywel,RAESystems SingleGas BW Clip,Extreme,ToxiRAEPro MultiGas MicroClip,Quatro,MaxXT,Micro5,QRAE3,MultiRAE PID MiniRAE3000,ppbRAE3000 InHouseGasDetectorServices Servicingalmakesandmodelsacrossvarious industrysectors QualityServiceFacility PortableGasDetectors Single,MultiGasandPID FixedGasDetectors Pre-deliveryconfiguration,testingandcalibration InHouseInstrumentServices Servicingalmakesandmodelsofmonitoring andsamplingequipment Breathalysers PortableandWalMounted ExhaustGasAnalysers standardundergroundminingconfiguration AirSamplingPumps SKC,Casela RentalFleet Coveringawiderangeofportableinstruments availableforshort-term tolong-term projects PortableGasDetectors Single,MultiandPID BumpTestandCalibrationStations FleetManagement,CalibrationGasandRegulators T:1300436267 +61892407541 F:1300263267 +61892407546 service@encoremonitoring.com.au A:4/199BalcataRoad,BalcataWA6021 PO Box1040,BalcataWA6914 www.encoremonitoring.com.au