IT 1911i. Industrial 2D-code hand-held scanner with RF transmission TECHNICAL DESCRIPTION. make technical changes. We reserve the right to

Similar documents
Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Manual Serial PCI Cards

Laser Barcode Scanner

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Metrologic MS1690 2D Scanner Installation Guide

Laser Barcode Scanner User s Manual

1 Technical Description Lokal-200PC

Bluetooth HC-06 with serial port module Easy guide

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Barcode Reader Series BCL 31, BCL 32, BCL 34

How to setup a serial Bluetooth adapter Master Guide

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version G

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Advanced Data Capture and Control Systems

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Bluetooth to Serial Adapter

CLV 41x Bar Code Scanner Standard line

PM1122 INT DIGITAL INTERFACE REMOTE

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Model 201 Wiegand Touchpad Reader Installation Guide

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

MS9500 SERIES VOYAGER PRODUCT GUIDE. Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners

CENTRONICS interface and Parallel Printer Port LPT

MLDSET Light Beam Safety Device Sets for access guarding with muting function

UniPi technical documentation REV 1.1

QUICK START GUIDE Bluetooth Cordless Hand Scanner (CHS)

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

Keep it Simple Timing

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

A RF18 Remote control receiver MODULE

Universal Serial Bus (USB) to DH-485 Interface Converter

How To Connect A Port Replicator With An Ethernet To A Usb Port From A Usb Device

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers

Application Note. Terminal Server G6

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

User manual Compact Web PLC WP240 series IEC-line

HT580 User Reference Guide. Version 1.0

PCS0100en Persy Control Services B.V. Netherlands

PCMCIA 1 Port RS EDITION OCTOBER 1999

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Connecting the Console Port to a PC

connecdim Gateway G1 Ethernet TCP/IP to DALI

MS830 / MS833 Barcode Reader v1.0 9-December-2014

BCST-20 Barcode Scanner. Instruction Manual.

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation Synergy Controller Bar Code Reader Applications

WEB log. Device connection plans

RS232 Programming and Troubleshooting Guide for Turbo Controls

DK40 Datasheet & Hardware manual Version 2

Combi switchbox with integrated 3/2 way pilot valve

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Bluetooth Serial Adapter

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

Using Xbee in Serial Communication

EPM110 Field Strength Measuring Instrument

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

TMCT-10 Barcode Scanner User Manual. 102, St. Edmonton, AB T6E 3N8 Ph Fax

VOICE RECORDING SYSTEM ISDN PRI / BRI

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

PHONE MANAGER INDEX. page

RC2200DK Demonstration Kit User Manual

S88XPressNetLI v1.0. Installation, user and reference manual KDesign Electronics, PCB design by RoSoft

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

EDI Distributor Control Interface Wiring and Setup Instructions

1. SAFETY INFORMATION

IP Indoor High Speed Dome. CAM-6500 series. Ver Quick Installation Guide

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

2100 POS System User Guide

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

BARCODE READER V 2.1 EN USER MANUAL

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

SPID Azimuth Antenna rotator Type: BIG-RAK/HR

Cable Specifications and Information

Application/Connection Examples

Modbus Communications for PanelView Terminals

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Industrial Bar Code Scanners

M3 ORANGE Snap-On. User Guide. Product Model: A-SNO-ATYP-060-R00. Compatible Device: M3 ORANGE. Version 2.2 Released in March 2013

User and installation manual

LBNP RS-232/485/422 serial device server. User manual

WEB log. Device connection plans

K128. USB PICmicro Programmer. DIY Electronics (HK) Ltd PO Box 88458, Sham Shui Po, Hong Kong. mailto:

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

SecureLinx Spider Duo Quick Start Guide

Transcription:

IT 1911i Industrial 2D-code hand-held scanner with RF transmission EN 50123793 2013/06 We reserve the right to make technical changes TECHNICAL DESCRIPTION

2013 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Phone: +49 7021 573-0 Fax: +49 7021 573-199 http://www.leuze.com info@leuze.de

Contents 1 Scope of delivery... 5 1.1 IT 1911i xx-3... 5 1.2 Base station IT 1911i... 5 2 Installation... 6 2.1.1 Switching off the PC... 6 2.2 Connecting the base station... 6 2.2.1 Connecting to base station IT 1911i... 6 2.3 How do I scan codes?... 7 2.3.1 Testing the scanner... 7 3 Technical Data... 8 3.1 Pin assignments of the connection cable... 8 3.1.1 KB 232-1 IT 190x Part no. 50114517... 8 3.1.2 KB PS2-1 IT190x Part no. 50114519... 8 3.1.3 KB USB-1 IT 190x Part no. 50114521... 8 3.1.4 KB USB-2 IT 190x Part no. 50114523... 9 3.2 Reading fields... 9 4 Resetting the IT 1911i to factory settings... 10 5 Configuration... 11 5.1 IT 1911i to the serial PC interface... 12 5.1.1 With KB 232-1 IT190x Part no. 50114517... 12 5.1.2 Configuration for the Leuze standard protocol... 13 5.2 IT 1911i to MA 200i... 14 5.2.1 Commissioning... 14 5.3 IT 1911i to MA 21... 17 5.4 IT 1911i to PS2 interface... 19 5.5 IT 1911i to USB interface (keyboard emulation)... 20 5.6 IT 1911i to USB interface (COM port emulation)... 21 5.7 Activating the read process... 22 5.8 Configuration... 22 5.9 Troubleshooting... 23 6 Type overview... 24 7 Accessories/Spare parts... 25 7.1 Connecting to Leuze multinet Plus... 26 7.2 Connection to various fieldbuses using MA 200i... 26 Leuze electronic IT1911i 3

8 Service and support... 27 Leuze electronic IT1911i 4

1 Scope of delivery 1.1 IT 1911i xx-3 Scanner reading field 1. Hand-held scanner IT 1911i 2. Rechargeable battery (installed) 3. Package insert Laser notice Information about standards 1.2 Base station IT 1911i 1. Base station CCB02-100BT Type designation Information about standards An overview of the types can be found on page 24. For accessories, see page 25. Leuze electronic IT1911i 5

2 Installation 2.1.1 Switching off the PC NOTICE Make sure that the PC is switched off before connecting the scanner. 2.2 Connecting the base station Shown in the figure below are the locations for installing the cable on the base station. Connection for power supply unit Connection for interface cable 2.2.1 Connecting to base station IT 1911i 1. To secure the connection cable to the base station, proceed as follows: Insert the RJ 41 connector into the socket on the bottom of the base station until the cable clicks into place. 2. Connect the other end of the connection cable to the appropriate connection socket on the PC. 3. You may need a power supply unit for voltage supply if you would like to charge the hand-held scanner at the base station or if you use an RS 232 interface. Use the pin assignments (see page 8) to select the appropriate cable for your application. 4. Connect the power supply unit to the power socket. 5. Configure the hand-held scanner using the codes for the corresponding application; see chapter "5 Configuration" or the external document "User s Guide IT 1910i/1911i". Leuze electronic IT1911i 6

6. Check the operational readiness of the scanner by pointing the scanning surface towards a flat surface and pulling the trigger. A green target line as well as the red illumination should now be visible. Now scan a sample label. The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the PC. 2.3 How do I scan codes? This section explains the best way to scan codes: The scanner must be held at a slight angle to the bar code. (Do not hold the scanner at a right angle to the bar code.) The green LED line which serves as an alignment aid should be positioned at the center of the code. This ensures that the center point of the camera is aligned with the code. (The scanner will not be able to detect the label correctly if it is not fully captured by the camera.) The green LED line is smaller and narrower if the scanner is held closer to the code. Small codes should be read at a smaller reading distance. With larger codes, the reading distance must be large enough so that the camera can capture the complete code. 2.3.1 Testing the scanner The adjacent bar code can be used for testing the scanner, the module size is 0.5 mm (20 mil) Code 39 bar code sample Leuze electronic IT1911i 7

3 Technical Data The technical data can be found in the data sheet for the IT 1911i. 3.1 Pin assignments of the connection cable 3.1.1 KB 232-1 IT 190x Part no. 50114517 Helix cable, maximum length 3 m. Signal level 0 and +5 volts TTL Pin assignments of the 9-pin D-sub socket (female) for cable CBL-020-300-C00 Pin number Signal Designation 1 nc Not used 2 TX Transmit data 3 RX Receiving line / Receive Data 4 nc Not used 5 GND Ground connection 6 DTR Data set ready (+5 volt connected to output) 7 CTS Clear to send 8 RTS Request to send 9 VCC IN 4.5 5.5 V DC (if no power supply unit is connected to the power supply unit connection) For the suitable power supply unit for IT 190x (100-230 V/50 60 Hz), see chapter 7. The power supply unit connection on the cable is not used. 3.1.2 KB PS2-1 IT190x Part no. 50114519 Helix cable, maximum length 3 m. Pin assignments of the Mini DIN socket or connector for cable CBL-720-300-C00 Pin Pin socket Signal Designation connector 1 - PC Data PC data line 2 2 NC Not used 3 3 GND Ground connection 4 4 VCC IN 5 Volts DC 5 - PC Clock PC clock line 6 6 NC Not used - 1 KB data Keyboard data line - 2 KB clock Keyboard clock line 3.1.3 KB USB-1 IT 190x Part no. 50114521 Straight cable, maximum length 3 m. Pin assignments of USB type A connector for cable CBL-500-300-S00 USB type A connector Signal Designation 1 VCC IN 5 Volts DC 2 Data - Data line - 3 Data - Data line + 4 GND Ground connection Leuze electronic IT1911i 8

3.1.4 KB USB-2 IT 190x Part no. 50114523 Pin assignments of USB type A connector for cable CBL-500-500-C00: as with part no. 50114521, but helix cable, maximum length 5 m. 3.2 Reading fields IT 1911i ER-3 Code 39 UPC Code 39 PDF 417 Data Matrix QR Code 5 mil (0.127 mm) 6.7 mil (0.170 mm) 10 mil (0.254 mm) 13 mil (0.330 mm) 20 mil (0.508 mm) 20 mil (0.508 mm) Typ. reading distance 1) [mm] 1) Dependent on code module Leuze electronic IT1911i 9

4 Resetting the IT 1911i to factory settings To reset all parameters to factory settings, scan the bar code shown below. Attention! All settings are lost! Return the IT 1911i to the base station so that the settings can be accepted. Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly. You may then continue making settings or operation of the device. Leuze electronic IT1911i 10

5 Configuration Usually, bar codes are used to configure the hand-held scanner. Select the desired bar code and scan it (see chapter 2.3). The configuration is then immediately accepted and executed. A second option is to configure the hand-held scanner with the USB and RS 232 interfaces with the aid of the VisualXpress PC program. You can download and install this program from our homepage at www.leuze.com. The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that it can be reused at a later time. The standard applications are described and summarized below. Leuze electronic IT1911i 11

5.1 IT 1911i to the serial PC interface 5.1.1 With KB 232-1 IT190x Part no. 50114517 For pin assignments, see chapter 3.1.1. Please connect the base station for IT 1911i acc. to the adjacent figure. Required parts: 1x 50122434 IT 1911i ER-3 1x 50122431 Base station IT 1911i 1x 50114517 KB 232-1 IT 190x 1x 50123862 Power supply unit RS 232 transmission with 115200 baud, 8 data bits, 1 stop bit, no parity, suffix CR/LF. Return the IT 1911i to the base station so that the settings can be accepted. Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly. Leuze electronic IT1911i 12

5.1.2 Configuration for the Leuze standard protocol Leuze standard protocol: RS 232 with 9600 baud, 8 data bits, 1 stop bit, no parity, prefix STX and suffix CR/LF Factory settings Return the IT 1911i to the base station so that the settings can be accepted. Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly. To configure the device, please scan the codes in the specified order. Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly. RS 232 baud rate: 9600 Prefix STX Suffix CR/LF Alternatively, the following Aztec configuration code can also be used: The individual pieces of bar code information are again provided in succession in the Aztec configuration code. Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i 13

5.2 IT 1911i to MA 200i RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, suffix CR/LF. Required parts: 1x 50122434 IT 1911i ER-3 1x 50122431 Base station IT 1911i 1x 50114517 KB 232-1 IT 190x 1x 50123862 Power supply unit 1x 50113397 KB JST-HS-300 1x 50112893 MA 204i Profibus gateway or 50112892 MA 208i Ethernet gateway or 50112891 MA 248i Profinet gateway 5.2.1 Commissioning Open the MA 200i Guide KB JST-HS-300 with the PG cable gland through the threaded hole and insert the 12-pin JST connector Connect the base station with the RS 232 cable Connect the RS 232 cable to the 9-pin D-sub connector Set the address using the address switch Insert the field bus connection cable Apply the voltage supply. Please connect the base station acc. to the following figure. Leuze electronic IT1911i 14

Base station for IT 1911i KB JST-HS-300 approx. 0.3 m 9-pol. D-sub 18 to 30 V DC Details on connecting the MA 200i can be found in "Technical description MA 200i". NOTICE You can find the configuration codes on the next page. Leuze electronic IT1911i 15

5.2.1.1 Configuration Factory settings Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. To configure the device, please scan the codes in the specified order. Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly. RS 232 baud rate: 9600 Suffix CR/LF Alternatively, the following Aztec configuration code can also be used: The individual pieces of bar code information are again provided in succession in the Aztec configuration code. Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i 16

5.3 IT 1911i to MA 21 RS 232 transmission with 9600 baud, 7 data bits, 1 stop bit, even parity, suffix CR/LF. Required parts: 1x 50122434 IT 1911i ER-3 1x 50122431 Base station IT 1911i 1x 50114517 KB 232-1 IT190x 1x 50123862 Power supply unit 1x 50035421 KB 021 Z 1x 50030481 MA 21 100 5.3.1.1 Pin assignments KB021 Z Core color Signal Terminal assignments MA 21 brown (RXD) 26 white (TXD) 27 blue (GND) 28 red (VCC) black (GND) bare (shield) (PE) 21 Leuze electronic IT1911i 17

5.3.1.2 Configuration Factory settings Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. To configure the device, please scan the codes in the specified order. Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly. RS 232 baud rate: 9600 7 data bits, even parity, 1 stop bit Suffix CR/LF Alternatively, the following Aztec configuration code can also be used: The individual pieces of bar code information are again provided in succession in the Aztec configuration code. Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i 18

5.4 IT 1911i to PS2 interface The operation of the IT 1911i in keyboard-wedge mode is described in this chapter. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs. Required parts: 1x 50122434 IT 1911i ER-3 1x 50122431 Base station IT 1911i 1x 50114519 KB PS2-1 IT190x 1x 50123862 Power supply unit Please connect the base station acc. to the figure below. To do this, proceed as follows: 1. Switch off the PC. Disconnect 2. Unplug the keyboard. 3. Connect the cable for the base station between the keyboard and the PC. 4. Switch the PC back on. 5. Scan the code shown below. NOTICE To charge the IT 1911i, the power supply unit must be plugged in and the hand-held scanner placed in the base station. 5.4.1.1 Configuration PS2 keyboard emulation with CR LF Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i 19

5.5 IT 1911i to USB interface (keyboard emulation) The operation of the IT 1911 in keyboard-wedge mode on a USB port is described in this chapter. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs. Required parts: 1x 50122434 IT 1911i ER-3 1x 50122431 Base station IT 1911i 1x 50114521 KB USB-1 IT190x or 50114523 KB USB-2 IT190x 1x 50123862 Power supply unit Please connect the base station acc. to the figure below. To do this, proceed as follows: 1. Connect the cable for the base station to a free USB port. 2. The scanner acknowledges this connection with an acoustic signal. 3. Scan the code shown below. NOTICE To charge the IT 1911i, the power supply unit must be plugged in and the hand-held scanner placed in the base station. 5.5.1.1 Configuration USB keyboard emulation with CR LF Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i 20

5.6 IT 1911i to USB interface (COM port emulation) The operation of the IT 1911i as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface can be downloaded from our homepage at www.leuze.com. Thus, the data can be processed further in programs which expect data via COM interfaces. Required parts: 1x 50122434 IT 1911i ER-3 1x 50122431 Base station IT 1911i 1x 50114521 KB USB-1 IT190x or 50114523 KB USB-2 IT190x 1x 50123862 Power supply unit Please connect the base station acc. to the figures below. To do this, proceed as follows: 1. Install the USB serial driver for the IT 1911i. 2. Connect the cable for the base station to a free USB port. 3. The scanner acknowledges this connection with an acoustic signal. 4. Scan the code shown below. 5. Open a terminal program or your program for the serial interface, select the new COM port, and make the following settings: baud rate 115200, 8 data bits, 1 stop bit and no parity. A CR is transmitted as suffix (or terminator). NOTICE To charge the IT 1911i, the power supply unit must be plugged in and the hand-held scanner placed in the base station. Leuze electronic IT1911i 21

5.6.1.1 Configuration COM port emulation on the next free COM address with 38400 baud, 8 data bits, 1 stop bit, no parity and a CR as suffix. Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. 5.7 Activating the read process To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation only). The command is to be sent at the set baud rate, parity, and data and stop bits. The activation command is: SYN T CR ASCII decimal values: 022; 084; 013 To cancel read readiness, send a deactivation. The deactivation command is: SYN U CR ASCII decimal values: 022; 085; 013 Following a successful read operation, the IT 1911i deactivates itself. The second option is to use the trigger button to establish read readiness. 5.8 Configuration Further details on configuration, such as parameters for code type release, number of digits, etc., can be found in the User's Guide IT 1910i/1911i. Leuze electronic IT1911i 22

5.9 Troubleshooting For problem detection and troubleshooting, examine your scanner as follows: 1. If the scanner is supplied with power via the connection cable, the scanner and PC must be connected to each other before the scanner is commissioned. The PC must supply the scanner with 5 V DC. Check the manual for your PC to ensure that the power supply is adequate for connecting your scanner. 2. Make certain that the connection cable is securely connected to the PC. You can find information on properly connecting the scanner in the manual for your PC. Support is also available from your technical staff. 3. If your system operates with an external voltage supply, make certain that the power supply unit is properly connected to the scanner. 4. Check that the connection cable is securely connected to the base station. At the base station, please loosen the cable using a small pin: the connector is unlocked. 5. If, even after performing all of these measures, the scanner is not ready for operation, replace the power supply unit with a different recommended power supply unit which you are certain functions properly. 6. Make certain that your scanner's interface is compatible with the PC. Further information on this topic can be found in the manual for your PC. Also check whether the scanner has been configured for the desired application. This information is given in the User s Guide IT 1910i/1911i. 7. Check whether the bar code labels which you would like to scan are of suitable quality and that the used bar code type is recognized by your scanner. Damaged bar code labels (crinkled, torn or soiled) may be recognized poorly or not at all by the scanner. If you suspect that the problem lies with the quality of the label, check the read readiness with a label of relatively good quality. 8. If the problems are still not corrected, please contact the Leuze electronic hotline (see chapter 8). Leuze electronic IT1911i 23

6 Type overview IT series Part no. Designation Interface Figure Industrial hand-held reader for bar codes and 2D-codes 50122434 IT 1911i ER-3 Bluetooth class 1 Base station with communication and charging function 50122431 Base station for IT 1911i Bluetooth class 1 PS2 / USB / TTL RS 232 All devices are supplied without cable. Cables must be ordered separately; see chapter "7 Accessories/Spare parts". Leuze electronic IT1911i 24

7 Accessories/Spare parts Accessories for IT series IT 1911i Base station for IT 1911i Part no. Designation Length, type P/N no. Figure 5V 50114519 KB PS2-1 IT 190x PS2 cable for IT 190x 3 m spiral CBL-720-300-C00 - X 50114521 KB USB-1 IT 190x USB cable for IT 190x 3 m straight CBL-500-300-S00 - X 50114523 KB USB-2 IT 190x USB cable for IT 190x 5 m spiral CBL-500-500-C00 - X 50114517 KB 232-1 IT 1900 RS 232 cable for IT 190x 3 m spiral CBL-020-300-C00 - X 50123862 NT Base IT 1911i Voltage supply for the base station (5 V DC), RS 232 cable and base station 1.8 m straight PS-05-1000W-C - X 50105384 Battery for IT 1911i, 3820, 4820 and IT 6320 3.7 V / 2000 mah 100000495 X - 50114494 BAT-Charger-4 Desk-EU Charging station with power supply unit for up to 4 batteries 2 x 1.5 m straight MB4-BAT- SCN01EUD0 X - 50120444 BT Wallholder HS65x8 wall mount; plastic 11-66553-06R X 50107034 Rope for IT3800i/4800/6300 steel rope; plastic ToolBalE X Leuze electronic IT1911i 25

7.1 Connecting to Leuze multinet Plus MA 21 100 Interface converter / multinet plus Part no. 50030481 KB 021 Z Connection cable MA xx to IT 1911i Part no. 50035421 7.2 Connection to various fieldbuses using MA 200i MA 204i Profibus gateway Part no. 50112893 or MA 208i Ethernet gateway Part no. 50112892 or MA 248i Profinet gateway Part no. 50112891 KB JST-HS-300 Connection cable MA xx to IT 1911i Part no. 50113397 Leuze electronic IT1911i 26

8 Service and support 24-hour on-call service at: +49 (0) 7021 573-0 Service hotline: +49 (0) 7021 573-123 Monday to Thursday 8.00 a.m. to 5.00 p.m. (UTC+1) Friday 8.00 a.m. to 4.00 p.m. (UTC+1) E-mail: service.identify@leuze.de Return address for repairs: Service center Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Leuze electronic IT1911i 27