icom Network Alarm Router & icom-e Encrypted Network Alarm Router

Similar documents
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

DMP Network Monitoring

IP SERIAL DEVICE SERVER

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Digicom Remote Control for the SRT

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

N300 WiFi Range Extender WN2000RPT User Manual

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

RN-XV-RD2 Evaluation Board

2012 uptimedevices.com

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

1. MOXA NPort Express TCP/IP to RS-232 server

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

HWg-STE HWg-STE PoE MANUAL

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

One Port Serial Server Users Manual Model ESP901, ESP901E

How to configure DVR and computer for running Remote Viewer via IP network

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Ethernet 241 (USB/Serial) Quick Start Guide

Crow Limited Warranty. Print Version 017

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

Linksys E2000 Wireless-N Router Configuration Guide

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

LBNP RS-232/485/422 serial device server. User manual

OUTDOOR IR NETWORK CAMERA Series

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

MODBUS TCP to RTU/ASCII Gateway

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

F2103 GPRS DTU USER MANUAL

Connecting the Console Port to a PC

1 Serial RS232 to Ethernet Adapter Installation Guide

How to setup a serial Bluetooth adapter Master Guide

Computer Networks I Laboratory Exercise 1

EZ-View Network Communications Guide

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Follow these steps to prepare the module and evaluation board for testing.

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

Easy Setup Guide for the Sony Network Camera

ipdatatel Wi-Fi BAT Installation and Configuration Guide

Preparing the Computers for TCP/IP Networking

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

your Gateway Windows network installationguide b wireless series Router model WBR-100 Configuring Installing

INTRODUCTION FEATURES OF THE ICM

SNMP Web Management. User s Manual For SNMP Web Card/Box

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Rev NetCom Card Installation and Programming Guide

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Setting up VPN Access for Remote Diagnostics Support

Kantech IP Link Enhanced Ethernet Device

User Manual. EtherUSB

AXIS 205 Network Camera Quick Installation Guide

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

LS-101 LAN to Serial Device server. User s Manual

Ethernet Radio Configuration Guide

NESS-APX. Training Manual

EMG Ethernet Modbus Gateway User Manual

Linksys Gateway SPA2100-SU Manual

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

WUA Mbps Wireless USB Network Adapter

Configuring the Switch with the CLI-Based Setup Program

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

3.5 EXTERNAL NETWORK HDD. User s Manual

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

A Division of Cisco Systems, Inc. GHz g. Wireless-G. PCI Adapter with RangeBooster. User Guide WIRELESS WMP54GR. Model No.

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

MFC7840W Windows Network Connection Repair Instructions

The Wireless LAN (Local Area Network) USB adapter can be operated in one of the two following networking configurations :

Serial over Ethernet Device Server. User s Manual

Quick Installation Guide. Overview. GULFSIP ATA-G1S Quick Installation Guide

Wireless LAN g USB Adapter

Inter-Tel IP Phone Quick Reference Guide

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

Configuring the Switch with the CLI Setup Program

Debugging Network Communications. 1 Check the Network Cabling

INSTALLATION AND OPERATION MANUAL CNFE2DOE TERMINAL SERVER

T3 Mux M13 Multiplexer

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Zebra Ethernet. Frequently Asked Questions

2 Setting Up the Hardware for a Wired Ethernet Network Setting Up the Software for an Ethernet Network... 21

Setting up Digi Connect Wi-SP or Digi ConnectPort TS W Devices On a Secured Wireless Network for use with Veriteq viewlinc

RS232 Programming and Troubleshooting Guide for Turbo Controls

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Prestige 2002 Series. VoIP Analog Telephone Adaptor. Quick Start Guide

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

UPS Network Interface. Quick InstallationGuide

PRILINK PRI Management System

Wi-Fi Setup Guide USING YOUR DMX PROFUSION is FOR

DSL Installation Guide

Rev GSM base station. Installation instructions

Symphony Network Troubleshooting

HC Products ILF-100WD User Manual

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

DVQ-2, DMR8RT, DMR16RT QUICK-START GUIDE

Transcription:

Installation Guide icom Network Alarm Router & icom-e Encrypted Network Alarm Router Description The icom Network Alarm Router and icom-e Encrypted Network Alarm Router allow DMP Command Processor Panels to communicate over an Ethernet or a full-time Internet connection to a DMP SCS-1R Receiver. The icom/ icom-e are compatible with XR500 panels. Operating as an interface between the panel and the network, the icom or icom-e installs inside the panel enclosure and communicates through a 462N Network Interface Card or connects directly to the panel using the nine-pin serial connector on J21 as shown in Figure 2. These instructions apply to both the standard icom and the icom-e. Please note the specific programming options for the icom-e version only and the specific installation steps for the icom/icom-e and XR500 panel. icom-e Description For High Security applications where the Advanced Encryption Standard (AES) Rijndael Encryption Algorithm is required or desired, use the icom-e Encrypted Network Alarm Router. The icom-e is NIST certified. Note: The icom-e is not compatible with the XR500N, XR500E, or XR2500F panels. Components The following components are included: icom Network Alarm Router OR icom-e Encrypted Network Alarm Router 2-wire Power Cable DMP Model 356-2 Serial Cable 4-wire Keypad Programming Cable (to program the icom or icom-e) What Else is Needed Additional equipment needed to install, program, and use the icom or icom-e: DMP 32-character LCD keypad OR a computer with available serial communications port Hyperterminal communication (terminal emulation) software or Telnet (if using a computer to program the icom or icom-e) DMP Model 396 Programming Cable (if using a computer to program the icom or icom-e) Ethernet or full-time Internet connection DMP XR500 Command Processor Panel and 397 panel-to-icom cable 461 Interface Adaptor Card for XR500 panels without an available expansion slot Wiring Notes for XR500 Panels 1. The network cable connected to the icom or icom-e J4 Network Connector cannot directly leave the building where the icom or icom-e is installed. You must connect the cable to another network device, such as a router or gateway, before establishing an external connection. 2. If you extend the power cable, you must use crimp connectors. 3. Program the icom/icom-e before plugging the 397 cable into the icom/icom-e from the RS-232 port, J21. 4. If you are programming the icom or icom-e with a computer, do not connect 2-wire Power Cable. See Preparing to Program the icom or icom-e with a Computer later in this document.

Wiring the icom/icom-e and 462N Card See the Wiring Notes above before completing these connection steps. 1. After properly installing the icom or icom-e in the enclosure, connect the Ethernet cable from your network to the icom or icom-e Network Connector (J4). 2. After programming, connect the supplied Model 356-2 Serial Cable to the 462N card J7 connector. 3. Attach the 356-2 cable from the 462N card to the icom or icom-e J3 Serial Connector. 4. Connect the 2-wire Power Cable to J2 Power Connector. 5. Connect the power cable red wire to terminal 7 on the panel. 6. Connect the power cable black wire to terminal 10 on the panel. Configuring the 462N Card To configure the 462N, adjust the jumper settings on the 462N as shown in Figure 1. Refer to the 462N Network Interface Card Installation Sheet (LT-0209) for installation and setup instructions. Note: The XR500 panel does not require the 462N Card, but can use the 462N card in some installations. For standard XR500 installation, refer to the XR500 panel wiring on the next page. YES NO YES NO J1 J4 RXD TXD EXT 9600 4800 J2 2400 J5 1200 300 J6 J3 FORCE CTS DNET HST RXD = NO TXD = NO Baud Rate = 9600 J3 = FORCE J6 = HST Wiring the icom/icom-e and XR500 Panel Figure 1: 462N Jumper Settings See the Wiring Notes on the previous page before completing these steps. 1. After properly installing the icom or icom-e in the enclosure, connect the Ethernet cable from your network to the icom or icom-e to J4 Network Connector. 2. Install a jumper on the top pair of headers next to the letter "R" on J23. 3. Reset the panel using the J16 jumper to activate RS-232 operation. 4. Connect a Model 397 Serial Cable to J21 RS-232 nine-pin connector on the XR500 panel. 5. Connect the 2-wire Power Cable to J2 Power Connector. 6. Connect the power cable red wire to terminal 7 on the panel. 7. Connect the power cable black wire to terminal 10 on the panel. R LX J23 RS-232 J21 XR500 Command Processor Panel J6: Expansion Connector icom/ icom-e J3: Serial J4: Network J1: To Keypad for Programming J2: To Panel for Power AC +B BELL GND SMK GND GND AC -B GND GND GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9+ Z9- Z10+ Z10-1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 9 20 21 22 23 24 25 26 27 28 Power limiting wiring routing Black Red Serial Cable Figure 2: icom / icom-e and XR500 Installation and Power Wiring Programming for Network Communication You must program the XR500 for network communication. 1. Reset the panel using the J16 jumper. 2. From the keypad, enter 6653 and press COMMAND. 3. Press the COMMAND key until you reach the Communication programming section. For Communication Type, Select NET for Network communication. 2

icom or icom-e LED Indicators Refer to Figure 4 for each LED location. Serial Communication LEDs Transmit: A flashing green LED indicates the unit is transmitting serial data to the panel. Receive: A flashing yellow LED indicates the unit is receiving its serial data from the panel. Network LEDs Error 1 & 2: For DMP internal use only. Activity: A yellow flashing LED indicates activity on the network. Link: A steady on green LED indicates the communication link to the network is okay. RJ-45 8-pin modular jacks To Keypad for Programming To Panel or SCS-101 J8 for Power Black Red Black Red J3 Serial J4 Network J1 J2 Keypad Panel icom/icom-e Receive Transmit Power Serial LEDs Network LEDs Figure 4: icom /icom-e PCB Standoffs Error 1 Error 2 Acrivity Link Preparing to Program the icom or icom-e You may program the icom or icom-e with a DMP 32-character LCD keypad or a computer running Hyperterminal communication software. Preparing to Program the icom or icom-e with a Keypad To program the icom or icom-e with a DMP 32-character keypad, set the CURRENT KEYPAD ADDRESS to 1 (one) and select SUP for the KEYPAD MODE. These options are programmed in the Keypad Options menu. Refer to the keypad installation sheet for more information. After programming these two settings, follow the steps below. 1. Disconnect the 2-wire Power Cable from the icom or icom-e J2 Power Connector. See Figures 2 and 3. 2. Disconnect the 356-2 serial cable from the J3 Serial Connector. 3. Connect a DMP 32-character LCD keypad to the J1 Programming Connector. 4. Reconnect the power cable to the J2 Power Connector. 5. The keypad displays icom PROGRAMMER or icom-e PROGRAMMER. Press the Command key to enter programming mode. While programming the icom or icom-e with a keypad, press the COMMAND key to advance to the next programming option. To begin entering programming information press any top row Select key. You can return to the previous programming option by pressing the Back Arrow key. Note: IP addresses and port numbers may need to be assigned by the network administrator. When entering an IP, Gateway, or Subnet Mask address be sure to enter all 12 digits and leave out the periods. For example, IP address 192.168.000.250 is entered as 192168000250. Programming the icom or icom-e with a Keypad LOCAL IP ADDRESS 192.168.000.250 Local IP Address This is the icom or icom-e IP address. The Local IP Address must be unique and cannot be duplicated on other icom Network Alarm Routers or icom-e Encrypted Network Alarm Routers. When DHCP is set to YES the DHCP server IP address displays for reference. No change to the IP address can be made. Default value is 192.168.000.250. Note: Prior to entering a static IP Address, DHCP must first be set to No. See the DHCP Mode Enabled prompt for additional information. GATEWAY ADDRESS 000.000.000.000 SUBNET MASK 255.255.255.000 RMT IP ADDRESS 000.000.000.000 Gateway Address The Gateway IP Address is needed to exit your local network. When DHCP is set to YES this prompt does not display. Default value is 000.000.000.000. Subnet Mask Enter the local subnet mask assigned to the icom or icom-e. When DHCP is set to YES this prompt does not display. Default value is 255.255.255.000. Remote IP Address The Remote IP Address is the receiver or computer network address where the icom or icom-e is to transmit messages. When Panel Mode is set to NO this prompt does not display. Default value is 000.000.000.000. 3

TCP Comm ENABLED YES NO Local/rmt PORT 2001 TELNET PORT 9999 RS232 BAUD RATE 9600 PANEL MODE YES NO TCP Comm Enabled This setting tells the icom or icom-e whether you are using TCP communications. Default value is NO. Local/Rmt Port Local/Remote identifies the port used to communicate messages to and from the panel. Valid range is 1 to 65,535. Default value is 2001. Telnet Port Use this port to connect to the icom or icom-e to perform Telnet programming. Default value is 9999. RS232 Baud Rate This value identifies the rate at which data is exchanged between the computer serial port and the icom or icom-e RJ45 connector. To change the baud rate, enter the new value. Valid baud rates are: 300, 1200, 2400, 4800, 9600, and 19200. Default value is 9600. Panel Mode Enabled This configures the icom or icom-e for installation on an XR500 panel. When connecting to a panel NO is not used. Default value is YES. DHCP MODE YES NO DHCP Mode Enabled Note: This option appears only if Panel Enabled Mode is set to YES. If Panel Enabled Mode is changed to NO then DHCP Mode must be reset to NO and the icom or icom-e must use the Local IP Address number. If the icom or icom-e has a dynamic IP address press the Select key below YES. When set to YES the icom or icom-e must operate in DHCP MODE. When the DHCP MODE option is set to NO, the icom or icom-e must use the IP address entered in Local IP Address. The default value is YES. Note: When DHCP Mode is set to Yes, any static IP Address entered at the Local IP Address prompt is replaced by a dynamic IP Address when programming is finished. To immediately refresh the connected router ARP cache after programming, power down and power up the icom or icom-e. TELNET ENABLED YES NO PASSWORD ENABLED YES NO TELNET PASSWORD - Telnet Enabled (icom-e only) If you select Yes for Telnet Enabled, telnet programming is allowed. Selecting No for Telnet Enabled does not allow telnet programming. Any future programming must be completed locally if Telnet Enabled is NO. By default, telnet programming is enabled. Note: If NO is selected for TELNET ENABLED, the PASSWORD ENABLED and TELNET PASSWORD prompts do not appear. Password Enabled To require a password for icom or icom-e programming via telnet, press the Select key under YES. To allow icom or icom-e programming without a password, press the Select key under NO. The default value is YES. Note: For Fire Protective Signaling use, this option must be programmed YES. Telnet Password This option only displays if Password Enabled is set to YES. The default password is NEW. Enter a password with up to 8 alphanumeric characters. The password displays on the keypad as it is entered for programming, so be certain that no unauthorized individuals are able to view the display as you enter characters. 4

PASSPHRASE - Passphrase (icom-e only) In order to communicate using encryption, all icom-e units reporting to the SCS-1R receiver must have the same Passphrase. The SCS-101 installed in the receiver must also be programmed with the same Passphrase. To clear the Passphrase press any Select Key and then press the COMMAND key. To enable encryption type an 8 to 16-character Passphrase using alphanumeric characters. If you leave the Passphrase blank, the icom-e communicates with other icom-e units, but the data is not encrypted. The Passphrase is blank by default. Note: DO NOT LOSE THE PASSPHRASE. A lost or forgotten Passphrase requires that every icom-e unit reporting in to the same SCS-101 at the receiver be individually reprogrammed with a new Passphrase. STOP PROGRAMMER Stop Programmer This option provides a way to exit programming mode when you are programming the icom or icom-e. When STOP PROGRAMMER appears on the keypad press any Select key to end programming. REMOVE KEYPAD Remove Keypad REMOVE KEYPAD displays after you press any Select key to end programming. Preparing to Program the icom or icom-e with a Computer To program the icom or icom-e with a computer, connect the 396 Programming Cable from the icom or icom-e Serial Connector (J3) to an unused COM port on your computer. Refer to Figure 4 for connector locations. The instructions below are specifically written for programming your icom or icom-e using Hyperterminal, which is available on most computer Windows operating systems. 1. Connect the Model 396 Programming Cable from the icom or icom-e J3 Serial Connector to a COM port on your computer. Do NOT connect the 2-wire Power Cable to the icom or icom-e at this time. 2. Click Start > Programs > Accessories > Communications > Hyperterminal. 3. Double-click Hypertrm.exe. 4. Type a name for your connection, such as icom or icom-e, then click OK. 5. From the Connect Using drop-down menu select Direct to COM 1, or the COM port you are using to connect the icom or icom-e router, then click OK. 6. In the COM Properties window, select the following settings: Bits per second: 9600 Data Bits: 8 Parity: None Stop Bits: 1 Flow Control: None 7. Click OK in the COM Properties window. Note: You must complete step 9 within 15 seconds after completing step 8 (applying power to the icom/icom-e). 8. Connect the 2-wire Power Cable to the icom or icom-e J2 Power Connector. 9. Within 15 seconds of connecting the power cable, type xxx and press the Enter key. Note: If you were unable to type xxx in lower case and press Enter within 15 seconds after connecting power to the icom or icom-e, disconnect the power from the icom or icom-e. Wait a few seconds and repeat steps 8 and 9. After you type xxx in lower case and press Enter, a screen similar to Figure 5 below displays. The IP addresses and other values shown may vary from what you see on your screen. Note: IP addresses and port numbers may need to be assigned by the network administrator. When entering an IP, Gateway, or Subnet Mask address be sure to use the standard xxx.xxx.xxx.xxx format then press Enter. To configure each setting, type the line number or letter for that setting, press Enter, and the screen prompts you for the setting you need to enter. 5

Programming the icom or icom-e with a Computer The programming options are the same whether you are programming with a computer or a keypad. Specific instructions are provided for programming the icom or icom-e with either a computer running Hyperterminal or a keypad. Local IP Address This is the icom or icom-e IP address. To set the Local IP Address type 1 and press Enter to display Enter Local IP Address. The Local IP Address must be unique and cannot be duplicated on other icom or icom-e Network Alarm Routers. Type the address and press Enter. The default Local IP Address is 192.168.000.250. Note: Prior to entering a static IP Address, DHCP must first be set to No. See DHCP Mode Enabled for additional information. ** Ethernet Bridge**... icom Firmware Version: 103 10/01/03 Ethernet Address: 0 90 C2 80 15 10 *************Programmable Parameters*********** 1. Local IP Address...192.168.000.250 2. Gateway Address...000.000.000.000 3. Subnet Mask...255.255.255.000 4. Remote IP Address...000.000.000.000 5. Enable TCP Comms...N 6. Local/Remote Port...2001 7. Telnet Port...9999 8. RS232 Baud Rate...9600 9. Panel Mode Enabled...Y A. Password Enabled...Y B. DHCP Mode Enabled...Y C. Telnet Enabled...Y D. Passphrase... S. SAVE AND EXIT X. EXIT WITHOUT SAVE *********************************************** Enter Command ( 1 to 9, A to D, S, X ) and Enter. > Note: Options C and D are only available with the icom-e. Gateway Address You need the Gateway IP Address to exit your Figure 5: Computer Programming Screen local network. This IP address is not included in your subnet. To configure your Gateway Address type 2 and press Enter to display Enter Gateway Address. Type the address and press Enter. The default is 000.000.000.000. Subnet Mask To configure your Subnet Mask type 3 and press Enter to display Enter Subnet Mask. Type the address and press Enter. The default is 255.255.255.000. Remote IP Address The Remote IP Address is the receiver or computer network address where the icom or icom-e is to transmit messages. To configure your Remote IP Address, type 4 and press Enter to display Enter Remote IP Address. Type the address and press Enter. The default is 000.000.000.000. Enable TCP Comms The Enable TCP Communications tells the icom or icom-e whether you are using TCP communications. To configure this setting type 5 and press Enter to display TCP Comms (Y or N). The default is N. Local/Rmt Port Local/ Remote identifies the port used to communicate messages to and from the panel. If a setting change is required, type 6 and press Enter to display Local/Rmt Port #. Type the new setting and press Enter. The default is 2001. Valid range is 1 to 65,535. Telnet Port Use this port to connect to the icom or icom-e to perform Telnet programming. The default Telnet Port setting is 9999. If a setting change is required, type 7 and press Enter to display Enter Telnet Port #. Type the new setting and press Enter. RS232 Baud Rate The Baud Rate identifies the rate at which data is exchanged between the computer serial port and the icom or icom-e RJ45 connector. The default setting for the RS-232 Baud Rate is 9600. Leave this setting at 9600 when installing the icom or icom-e on a panel. If problems appear that might be related to communications, try adjusting this setting to a lower rate, such as 2400, to see if a lower baud rate helps improve communications. Valid baud rates are: 300, 1200, 2400, 4800, 9600, and 19200. To change this setting, type 8 and press Enter to display Enter RS232 Baud Rate. Type in the new baud rate and press Enter. If you change the baud rate on the icom or icom-e, change the baud rate on the 462N card to match the icom or icom-e baud rate. See Figure 1 for jumper settings to adjust the baud rate. 6

Panel Mode Enabled This setting tells the icom or icom-e whether it is installed on a panel. The default value is Yes, which configures the icom or icom-e for installation on an XR500 panel. To configure this setting type 9 and press Enter to display Enable Panel Mode (Y or N). To configure the icom or icom-e for use in a panel, type Y and press Enter. When connecting to a panel N is not used. The default is Y. Password Enabled This setting selects whether or not a password is required before making any programming changes to the icom or icom-e through a Telnet connection. The default is Y. To adjust this setting type A and press Enter. Type Y for the icom to require a password, or type N to allow icom or icom-e programming without a password. When No is selected, type xxx in lower case and press Enter. Note: For Fire Protective Signaling use, this option must be programmed Yes. Password If you selected Yes for Password Enabled, Password appears as the next item in the programming menu. Enter an alphanumeric password up to 8 characters long. Enter the password as all caps. The default password is NEW. DHCP Mode Enabled This setting configures the icom or icom-e to enter DHCP mode and allow the use of a dynamic IP address. To adjust this setting type B and press Enter to display Enable DHCP Mode (YES or No). Select No for the icom or icom-e to require a static IP address. Select Yes to enable the icom or icom-e to use dynamic IP addresses by entering DHCP mode. The default is Y. Note: When DHCP Mode is set to Yes, any static IP Address entered at the Local IP Address prompt is replaced by a dynamic IP Address when you Save and Exit. To immediately refresh the connected router ARP cache after Save and Exit, power down and power up the icom or icom-e. Telnet Enabled (icom-e only) If you select Yes for Telnet Enabled, telnet programming is allowed. Selecting No for Telnet Enabled disables telnet programming. Any future programming must be completed locally if Telnet Enabled is No. By default, telnet programming is enabled. To adjust this setting type C and press Enter. Passphrase (icom-e only) In order to communicate using encryption, all icom-e units reporting to the SCS-1R receiver must have the same Passphrase. The SCS-101 installed in the receiver must also be programmed with the same Passphrase. To enable encryption and enter the Passphrase, type D and press Enter to display Enter Passphrase. Type an 8 to 16- character Passphrase using alphanumeric characters. If you leave the Passphrase blank, the icom-e communicates with other icom-e units, but the data is not encrypted. The Passphrase is blank by default. Note: DO NOT LOSE THE PASSPHRASE. A lost or forgotten Passphrase requires that every icom-e unit reporting to the SCS-101 at the receiver be individually reprogrammed with a new Passphrase. Save and Exit To save your programming changes and exit the programming mode, type S and press Enter. Programming changes do not take affect until you Save and Exit. Exit Without Saving To exit programming mode without saving changes type X and press Enter. Completing the Installation After you finish programming the icom or icom-e, disconnect the keypad from the icom or icom-e J1 Programming Connector. Connect the 356-2 cable to the icom or icom-e J3 Serial Connector and the 462N card J7 connector. The icom or icom-e now communicates as programmed. Notes Supervision signals between premises alarm equipment and supervising station alarm receiver equipment shall be managed by the supervising station alarm receiver equipment and not an intermediary network agent, device, or service. Messages are transmitted via the User Datagram Protocol (UDP) or Transmission Control Protocol (TCP). Accommodates a minimum of 65,000 distinct account numbers. Device Network addressing must not make use of public Domain Name Servers (DNS). Each message sent between the premises and supervising station alarm receiver equipment is encrypted. The icom-e is 128-bit encrypted. 7

Specifications Operating Voltage Current Draw Dimensions 12 VDC Nominal 78.1mA 3" W x 5.5" H x 0.75" D Product Compatibility SCS-1R Receiver with SCS-101 Card installed XR100/XR500 Command Processor Panels 800-641-4282 www.dmp.com Made in the USA Listings and Approvals California State Fire Marshal (CSFM) FCC Part 15 NIST AES Algorithm Certificate #66 for icom-e only. See http://csrc.nist.gov/cryptval/aes/aesval.html Underwriters Laboratories (UL) Listed ANSI/UL 365 Police Connected Burglar ANSI/ UL 609 Local Burglar ANSI/ UL 1023 Household Burglar ANSI/ UL 1076 Proprietary Burglar ANSI/ UL 1610 Central Station Burglar ANSI/ UL 1635 Digital Burglar ANSI/ UL 985 Household Fire Warning Standard Line Security Encrypted Line Security Note: The icom-e cannot be exported outside the United States. INTRUSION FIRE ACCESS NETWORKS 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 LT-0587 1.01 2008, Inc. 8445