DeltaV Media Converters

Similar documents
S-series SQ Controller

S-series Mass Connection Solutions

DeltaV SISnet Repeater

DeltaV Control Network Hardware

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

M-series MD Plus Controller

HARTING econ 3000 Introduction and features

S-series DC to DC Power Supply

S-series DeviceNet Interface Card

M-series FOUNDATION Fieldbus I/O

HARTING mcon 1000 Introduction and features

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

M-series Virtual I/O Module 2

How To Protect Your Deltav Controllers From Cyber Attacks

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

DeltaV Smart Switches Displace Cisco Switches

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Microcor Wireless Transmitter (MWT)

HARTING mcon 3000 Introduction and features

10/100/1000 Base-T to Gigabit Fiber Media Converter

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

PoE+ Extender Switch User's Manual. Rev W

Using installed Fieldbus Wiring to carry Ethernet Communications

Redundancy Module QUINT-DIODE/40

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

3500/25 Enhanced Keyphasor*Module

S-series Electronic Marshalling

Hirschmann Switch-Tuning: The new Gigabit OpenRail.

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

1756 ControlLogix Chassis Specifications

My first Hirschmann: The SPIDER family of switches.

Optimux-34, Optimux-25

CompactLogix Power Supplies Specifications

TrueAlarm Fire Alarm Systems

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch

3500/22M Transient Data Interface

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Web Smart Switch

Emerson Smart Firewall

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches

TX2123 RS485 TO ETHERNET ADAPTOR

Wireless Field Data Backhaul

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Security & Surveillance Cabling Systems

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

CISCO 10GBASE X2 MODULES

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

G-TAP A Series // Data Sheet

Provides one channel for Ethernet over existing

OPT SERIAL TO FIBER OPTIC CONVERTER

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Media Converters & Chassis

Foxboro Evo Process Automation System

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

ABB RTU560A Series CMU & Modules

1000 BASE-X SFP. Key Features DATA SHEET HIGHLIGHTS 1000BASE-SX 1000BASE-LX 1000BASE-ZX 1000BASE BX-D*

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Technology Solution Guide. Deploying Omnitron PoE Media Converters with Aruba Access Points and AirMesh Routers

1788 Linking Device Specifications

Cisco Unified IP Phone Power Injector

DeltaV Smart Switches

Provides one channel for Ethernet over existing

HP ProCurve High-Speed Transceivers Installation Guide

Gigabit Switching Ethernet Media Converters - Product User Guide

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

Gigabit Ethernet Copper-to-Fiber Converters

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

OPTICAL FIBER repeaters/ isolators

Megapixall Security Tools & Accessories

Perle 10/100 Ethernet Media Converters

Telephone- and leased line modem for industrial applications TD-36

Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper

Perle 10/100/1000 Ethernet Media Converter Module

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Technical Information RIA14

Your single source for network transmission solutions.

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

3500/62 Process Variable Monitor

Rack mounted telephone- and leased line modem for industrial applications

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

Optimux-134, Optimux-125

Digital input modules

Introduction Media converters

Rosemount 333 HART Tri-Loop

NC-12 Modbus Application

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Optimux-134, Optimux-125

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

FILTERING/FORWARDING RATES 100Mbps port - 148,800pps 10Mbps port - 14,880pps. TRANSMISSION MEDIA 10BaseT Cat. 3, 4, 5 UTP/STP 100BaseTX Cat.

Rosemount 333 HART Tri-Loop

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Transcription:

DeltaV Distributed Control System Product Data Sheet DeltaV Media Converters Facilitates deployment of Electronic Marshalling in the field Supports both single-mode and multi-mode fiber optic cable Redundant power supply connections Hazardous area certified models available Includes wire terminals for easy installation Works with both DeltaV and DeltaV SIS 100 Mbit 1-port SM Media Converter makes it easier than ever to deploy Electronic Marshalling in the field. Introduction The DeltaV Media Converters provides an easy way to connect remote field enclosures with CHARM I/O Cards (CIOC) to the DeltaV Control Network. Fiber Optic cable can go longer distances than copper Ethernet cables and these media converters allow you to extend the DeltaV Control Network distances up to 15km. The media converters change the means of communication from copper to fiber Ethernet and vice versa and facilitates easy connectivity using both Single-Mode and Multi-Mode Fiber Optic cable. There are three different models of DeltaV Media Converters available with the following port options: Single-Mode Media Converter with one fiber port and one copper port Multi-Mode Media Converter with one fiber port and one copper port 2-Port SFP Media Converter with one copper port and 2 SFP cages that can be used for copper or fiber SFP modules (for safe area installation only) All three DeltaV Media Converters come in a Dual Media Converter Assembly with a Dual Media Converter Carrier and two media converters. This facilitates easy deployment for redundant DeltaV Control Networks.

Benefits Facilitates deployment of Electronic Marshalling in the field: DeltaV with Electronic Marshalling can be installed in cabinets in control rooms but installing it in enclosures in the field will mean that the I/O is installed closer to the field devices and thus can reduce the distance between the field devices and were the wire is terminated to the control system. Many times fiber optic technology must be deployed in order to connect CHARM I/O Cards in field enclosures with the controllers located in the control room building. Emerson has switches that offer both copper and fiber optic Ethernet, but the DeltaV Media Converters are specialized devices that will convert from copper to fiber in order to make it easier to deploy Electronic Marshalling in the field. Some installations require use of copper IOPs on the CIOCs to facilitate daisy-chaining of Ethernet from one CIOC to the next eliminating the requirement for switches. The media converters allow longer distances from the control room to a group of enclosures with CIOCs daisy-chained in the field. Supports multiple types of fiber optic: Both Multi-Mode and Single-Mode fiber types are supported. Multi-Mode can go distances up to 2km and Single-Mode can go up to maximum 15km distance with proper installation. Hazardous area certifications available: The Single-Mode and Multi-Mode media converters have hazardous area certifications and can be mounted in Class 1, Div. 2 and Zone 2 hazardous areas. The 2-Port SFP Media Converter allows various SFP modules connected to the SFP cages on the media converters and therefore cannot be certified for hazardous installation. Includes wire terminals for Easy Installation: Each Dual Media Converter Carrier includes terminals for redundant power supplies. These terminals are duplicated to allow daisy-chaining of the 24VDC power for easy installation. This reduces the need for a separate terminal block to feed power to additional Media Converters or CIOCs. Works with both DeltaV and DeltaV SIS: There are many use cases for the DeltaV Media Converters covering both DCS and SIS installations. Although most uses in DCS applications will be to connect a CIOC to the DeltaV Control Network, it can also be used to connect Wireless I/O Cards, Ethernet I/O Cards, DeltaV Controllers, DeltaV Zone 2 Remote I/O etc. For DeltaV SIS it can be used to connect the SZ Controller to the DeltaV Control Network, but it can also be used to connect CSLSs to the SZ Controllers. Redundant power supply connections: The Dual Media Converter Carrier includes terminals for redundant 24V DC Power Supplies and the Media Converter have LED diagnostics that will indicate any failure in the power supply. www.emerson.com/deltav 2

Specifications Operating temperature Storage temperature Relative Humidity Airborne contaminates Shock Vibration Protection Class Namur Common Specifications -40 to 70 C (-40 to 158 F) -40 to 85 C (-40 to 185 F) 5 to 95%, non-condensing ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating 10g 1/2 sinewave for 11 ms 1mm Peak-to-Peak from 2 to 13.2HZ; 0.7g from 13.2 to 150HZ IP20 NE21 Dimensions Power Requirement Media Converters: Height: 98 mm Width: 25 mm Depth: 113 mm Single-Mode Media Converter +24V DC +/-20% @ 100mA maximum Dual Media Converter Carrier: Height 130 mm Width 107 mm Depth: 47.5 mm Copper-Wire Port Fiberoptic Ports Power Requirement Copper-Wire Port Fiberoptic Ports One 10/100 BASE-TX port with RJ45 connector, capable of halfand full-duplex operation. One 100 BASE-FX single-mode port with LC connector, configured for full-duplex operation Power budget: At least 12 dbm on 9/125 micron SMF Distance range: 15km with proper installation Multi-Mode Media Converter +24V DC +/-20% @ 100mA maximum One 10/100 BASE-TX port with RJ45 connector, capable of halfand full-duplex operation. One 100 BASE-FX multi-mode port with LC connector, configured for full-duplex operation Power budget: At least 8 dbm on 50/125 micron MMF or 11 dbm on 62.5/125 micron MMF Distance range: 2km with proper installation www.emerson.com/deltav 3

Power Requirement Copper-Wire Port Fiberoptic Ports 2-Port SFP Media Converter +24V DC +/-20% @ 150mA maximum (2-Port version) One 10/100 BASE-TX port with RJ45 connector, capable of halfand full-duplex operation. Two SFP cages to be used with 100 BASE-FX SFP modules The following SFPs have been tested and need to be purchased separately. Type Manufacturer PartNumber MM Optixcom SFP-155LX-AT2K-T MM Avago HFBR-57E5APZ MM IMC 808-38102 MM BLACKBOX LFP402 SM Optixcom SFP-155LX-AT20K-T SM Avago AFCT-5760ATLZ/ATPZ SM BLACKBOX LFP403 LED indications LED Correct Operating Condition Fault Condition Fault Indication Corrective Action Green Power on On Off System power is not supplied to the media converter due to a possible line power problem. Check power connections. Red Input voltage out of range Power LED indications. Internal fault Off On (continuous) The input voltage is outside the 24 V ± 10% range, or there is a loss of power on either primary or secondary. Contact Emerson technical support. Check power supply. Fiber-optic port top LED LED Media Converter Condition Indication 100 Mbit 1-Port Media Converters 100 Mbit 2-Port SFP Media Converter On On The port is ready for connection. An SFP module is inserted in this position. Fiber-optic port bottom LED All 100 Mbit Media Converters On/Blinking Link/activity is present on this port. RJ45 port LED All 100 Mbit Media Converters On/Blinking Link/activity is present on this port. Port LED indications. www.emerson.com/deltav 4

Dimensions Dimensions of the Media Converters and Carrier. Wiring Diagrams Powering two redundant pairs of Media Converters. www.emerson.com/deltav 5

Examples of using DeltaV Media Converters with DeltaV Smart Switches and Controller Firewalls Example 1 - DeltaV Smart Switches with CHARMs I/O and DeltaV Media Converters. www.emerson.com/deltav 6

Example 2 - DeltaV Smart Switches with CHARMs I/O, DeltaV Media Converters, and Controller Firewalls. www.emerson.com/deltav 7

Callouts from architecture drawings above 1 100 m (max) straight-through or crossover cable. To prevent ground loops, build this cable assembly with a shielded, metal-enclosed RJ45 connector on one end and an isolated, plastic-enclosed RJ45 connector on the other end. The metal connector end of this cable must be placed on the switch and not on the PC. 2 100 m (max) straight-through or crossover cable. To prevent ground loops, build this cable assembly with a shielded, metal-enclosed RJ45 connector on one end and an isolated, plastic-enclosed RJ45 connector on the other end. The metal connector end of this cable assembly can be placed on either end of the link. 3 100 m (max) straight-through or crossover cable. The shield on the controller s RJ45 connector connects only to a Faraday cage in the controller; not to the controller s DC ground. Therefore, the RJ45 connectors are floating and the single point of ground is made at the switch to which the controller is connected. Build this cable assembly with a shielded, metalenclosed RJ45 connector on both ends. 4 Fiber-optic cable must be used for outdoor building-to-building communications to provide immunity from electromagnetic interference; for ground isolation between buildings; and to connect for distances greater than 100 m (328 ft). Either single-mode or multimode fiber-optic cable can be used with the appropriate DeltaV Smart Switches, but only multimode fiber-optic cable can be used with the fiber-optic I/O Port (IOP) on the CIOC Carrier. The 100 Mbit Media Converters are Ethernet switches, available with one RJ45 twisted-pair port and one of the following: One LC single-mode fiber-optic port One LC multimode fiber-optic port Two small form-factor pluggable (SFP) slots for fiber-optic SFP transceivers 5 100 m (max) straight-through or crossover cable. The shield on the CIOC s RJ45 connector connects only to a Faraday cage in the CIOC; not to the CIOC s DC ground. Therefore, the RJ45 connectors are floating and the single point of ground is made at the switch to which the CIOC is connected. In this figure, the CIOC cards are daisy-chained, so that the cable shield grounding is passed through from the first switch s shield ground to the first CIOC s shield ground and then from CIOC to CIOC throughout the chain. Note that the Primary and Secondary RJ45 shielded connectors are isolated from each other so there is no ground loop possible between Primary and Secondary shield grounds. CIOCs are daisy-chained in order to use short lengths of cable, for example within a cabinet, where the links are protected against damage. The cascade port, which is used to create the daisy-chain, is the lower port on the CIOC Carrier. It is recommended that for long lengths of cable, a star-wired connection from each CIOC back to the switch is used. Build this cable assembly with a shielded, metalenclosed RJ45 connector on both ends. 6 The I/O ports on the CHARM I/O Carrier hold a control network port and a cascade port. The cascade port is the lower port. The image in CHARM I/O Carrier specifications shows the two ports. When the cascade port is used to daisy-chain the CIOCs, it is recommended that you use counter-rotating wiring to increase availability in case a CIOC fails. When counter rotating wiring is used, the primary control network connects to the first CIOC which is the CIOC on the left in the image and the secondary control network connects to the last CIOC which is the CIOC on the right in the image. Use 100 m (maximum) straightthrough or crossover cables. The shield on the CIOC s RJ45 connector connects only to a Faraday cage in the CIOC, not to the CIOC s DC ground. Therefore, the RJ45 connectors are floating and the single point of ground is made at the switch to which the CIOC is connected. Build this cable assembly with a shielded, metal-enclosed RJ45 connector on both ends. The I/O ports are powered by the CIOCs installed in the carrier. If both CIOCs are removed from a CIOC carrier, enabled cascade ports become unpowered causing loss of communication to downstream CIOCs. Use redundant CIOCs if cascade ports are enabled to ensure that the cascade ports are powered and the CIOC is communicating with downstream CIOCs. In DeltaV Explorer, use the CIOC s Properties page to enable the cascade ports. 7 Any combination of DeltaV RM100, MD30, and FP20 Smart Switches can be daisy-chained in series up to 12 total. 8 If more than one RM100 or MD30 switch is required to increase port count in an area, use the gigabit uplink ports for the switch-to-switch connection to provide ample performance headroom on these aggregating links. 100mbit/s links can also be used for this purpose but normally those links are reserved for single devices on the edge of the network such as controllers and workstations. The RM100 and MD30 switches have two fixed 10/100/1000mbit/s uplink ports and two SFP uplink ports. The SFP ports can be fitted with optional fiber-optic SFP transceivers for long distance communications. Only two of the four uplinks in this area of the switch can be active at a time in any combination of twisted pair and SFP. Refer to the Smart Switch Product Data Sheet for available SFP fiber optic transceivers for the RM100 and MD30 switches. www.emerson.com/deltav 8

Callouts from architecture drawings above 9 The serial port is not required for process communications; it is used only for occasional out-of-band switch setup and management. 10 Use a ring tongue terminal to connect the ground screw on the switch or firewall to a suitable shield ground. This connection provides a ground for the twisted pair Ethernet shielded connectors. 11 100 m (max) straight-through or crossover cable. The shield on the CIOC RJ45 connector connects only to a Faraday cage in the CIOC; not to the CIOC s DC ground. Therefore, the RJ45 connectors are floating. The 100 Mbit Media Converter RJ45 connector is also floating. Certifications The following certifications are available for DeltaV Media Converters: CE: EMC - EN 61326-1 Low Voltage Directive (LVD) - 2014/35/EC FM: FM 3600 FM 3611 FM 3810 CSA: HazardousArea/Location DeltaV Media Converters can be installed and used based on the following Standards: FM(USA): Class I, Division 2, Groups A, B, C, D,T4 cfm(canada): Class I, Division 2, GroupsA, B, C,D,T4 ATEX: Ex na IIC T4 Gc IEC-Ex: Ex na IIC T4 Gc CSA C22.2 No 213-M1987 CSA C22.2 No 1010-1 ATEX: ATEX 94/9/EC EN60079-0 EN60079-15 IEC-Ex: IEC60079-0 IEC60079-15 Marine Certifications: IACS E10 ABS Certificate of Design Assessment DNV-GL Marine Certificate Regarding the Installation instructions please refer to the following Documents: Class 1 Division 2 Installation Instructions DeltaV Electronic Marshalling 12P5401 Zone 2 Installation Instructions DeltaV Electronic Marshalling 12P5403 www.emerson.com/deltav 9

Ordering Information Description Dual Single Mode Media Converter Assembly, includes Dual Media Converter Carrier and two 1-port Single Mode Media Converters. Dual Multi Mode Media Converter Assembly, includes Dual Media Converter Carrier and two 1-port Multi Mode Media Converters. Dual 2-port SFP Media Converter Assembly, includes Dual Media Converter Carrier and two 2-port SFP Media Converters. VE6060 VE6061 VE6062* Model Number *Only suitable for safe area installations. SFPs must be ordered separately and is not available directly from Emerson. Spare Part Ordering Information Description Model Number Dual Media Converter Carrier 1-port Single Mode Media Converter 1-port Multi Mode Media Converter 2-Port SFP Media Converter KL1720X1-BA1 KL1720X1-BB1 KL1720X1-BC1 KL1720X1-BD1* *Only suitable for safe area installations. SFPs must be ordered separately and is not available directly from Emerson. Emerson North America, Latin America: +1 800 833 8314 or +1 512 832 3774 Asia Pacific: +65 6777 8211 Europe, Middle East: +41 41 768 6111 www.emerson.com/deltav 2017, Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. The DeltaV logo is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.