High Purity Water ph Sensor with phaser TM

Similar documents
Trace Dissolved Oxygen Sensor

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Dissolved Oxygen Sensors

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

For additional information, please visit our website at

ENDURANCE Conductivity Sensors

General Purpose ph/orp Sensors

General Purpose ph/orp Sensor

Submersion/Insertion Toroidal Sensor

Toroidal Conductivity Sensor

Submersion/Insertion Toroidal Sensor

Sanitary and CIP Toroidal Sensor

SenTix 950 SenTix 980

Milwaukee USER MANUAL

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Installation Instructions S

Care and use guide. Contents. a handy solution made easy. page

not appearance. ADHESIVE SYSTEMS CORIAN As an integral part of its sheet and shape products, DuPont has developed a special adhesive.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual


Self Purging Liquid Trap (SPLT ) User s Manual

AIRMoN, ph and Conductivity Field Measurement

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Front brakes (FN- 3), servicing

USEPA Electrode Method Method 8156

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

ph Measurement and Control

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

PART 1 - INTRODUCTION...

REPAIR AND MAINTENANCE MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS FOR VW MK5

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

Operator Quick Guide EC SENSOR

ExStik TM ph Waterproof Meters

B150 Series Commercial Brewer. Direct Plumb Kit

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Installation Instructions

DISSOLVED OXYGEN PROBE

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

UPGRADING AND SERVICING GUIDE

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

5800 Temperature Sensor Cable Assembly

CETAC Z-Drive Assembly

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

CHROME FRONT BRAKE MASTER CYLINDER KIT

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

MAINTENANCE & TROUBLESHOOTING

Professional Plus. Calibration Tips

ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

Measurement by Ion Selective Electrodes

ClearView 100. Instruction Manual

Powers Controls TH 192 S Single Temperature Room Thermostat

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Global Water Instrumentation, Inc.

Calibration of Volumetric Glassware

NITROUS TRANSFER PUMP INSTRUCTIONS

UltraBasic Benchtop ph Meter Operation Manual

Float and Thermostatic Traps Series H, C and X

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Installation Instructions

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

The Drink-Aide The NEW look of independence

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

60" TulleTM. Instruction Manual. A Kichler Select ceiling fan

2008 ACCORD - Front Knuckle/Hub/Wheel Bearing Replacement (page 18-13)

INSTALLATION & OPERATING INSTRUCTIONS

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

INSTALLATION MANUAL MODEL RP-100

Cleaning & Sanitisation

BATTERIES 2010, 2003 by David A. Katz. All rights reserved. Permission for academic use with original copyright retained.

MODEL G300 BRAKE BLEEDER

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST

Your safety and the safety of others are very important.

SHOT BLAST CABINET MODEL NO: CSB20B

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

DIGITAL WARMING CABINETS

CALIBRATION FOR LAL20X & LAL24X

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Oregon Fuel Injection

Class 5 to 7 Truck and Bus Hydraulic Brake System

Transcription:

Instruction Manual 51A-3200HP/rev.C June 2008 High Purity Water ph Sensor with phaser TM Flowing Junction SPECIFICATIONS Sensor Type: 3200HP Part Number: 3200HP-01, -02, -03, HPO and 3200HP-OEM, -OEM-01, -OEM-02, -OEM-03 Accuracy: ±0.05 ph Noise: < 0.02pH Drift: < 0.05 ph per week Conductivity Range: > 0.4 µs/cm Sample flow rate: 1-3 gph (60-180 ml/min) Wetted Materials: Silicone, polycarbonate/polyester, glass, stainless steel, PVDF, Viton 1 Sample Temperature: 0 o C - 70 o C (32 o F to 160 o F) Sample pressure: 5-10 psig drain to atmosphere. Process connection: 1/4 inch FNPT Reference Electrode: Flowing open capillary Weight/Shipping Weight: 5.4lb/7.6lb (2.5kg/3.5kg) VP6 Cable Connection: 10ft use PN 23645-10 20ft use PN 23645-11 30ft use PN 23645-12 Model 3200 HP For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit our website at www.emersonprocess.com/raihome/liquid/. 1. Viton is a registered trademark of DuPont Performance Elastomers. NOTICE SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not be compatible with process com position and operating conditions. Application compat ibility is entirely the responsibility of the user.

MODEL 3200HP Installation REPLACEMENT PARTS Part Number Description 34132-00 Flowing junction reference capillary disc and O-ring 9160590 Cartridge filter for reference electrolyte solution 9210391 Reference fill solution, 500 ml 3200HP Replacement 3200HP ph sensor 9601025 Air bleed screw 9913804 Washer for air bleed screw INSTALLATION 1. Refer to Figure 1. 2. Mount the back plate on a wall or Sample Panel 3. Remove the bag containing the Diffuser from the flow cell. Remove the Diffuser from the bag and place it in the bottom of the flow cell. 4. Connect the sample line and provide a drain line to the flow cell. The flow cell fittings are ¼ FNPT. 5. Set sample flow to between 1 and 4 gallons per hour, flow must remain constant for maximum measurement accuracy. inch mm PN 3200HP PN 9601025 PN 34083-00 2 FIGURE 1. Dimensional drawing of 3200HP system

Installation PUTTING THE 3200 HP IN SERVICE 1. Wire the Varipol (VP) cable to the analyzer. See the wiring diagrams in the WIRING section. 2. Start the sample flow. Adjust flow to between 1 and 4 gph (60-240mL/min). 3. Unscrew the clear plastic nut on the flow cell and slip the nut over the sensor. 4. Connect the VP cable to the sensor. The sensor connector is keyed to ensure proper mating with the cable receptacle. Once the key has slid into the mating slot, hand tighten the connection by turning the knurled ring clockwise. 5. Remove the vinyl cap from the end of the sensor. WARNING CAUTION The solution in the protective cap may cause skin or eye irritation. 6. Place the sensor in the flow cell with the cavity containing the reference capillary disc facing forward, away from the back panel. Tighten the flow cell nut securing the sensor in place. Verify the sample is flowing. 7. Remove the square reservoir bottle from the clip on the back plate. 8. Turn the bottle upright. Unscrew the cap and put it in a clean place. DO NOT REMOVE THE PLUG FROM THE FILTER. 9. Pour 500 ml of reference fill solution (PN 9210391) into the reservoir. Replace the cap. 10. Remove the shipping plugs from the reservoir filter and reference electrolyte tube. Save both plugs. Connect the electrolyte tube to the filter. The luer fitting on the tube presses onto the fitting on the filter. 11. Invert the reservoir and slip it into the clip on the back plate. A few drops of liquid may fall out of the air vent inlet. 12. Bleed air bubbles from the tube and sensor. a. Loosen the bleed screw until it is engaged by only about one thread. b. Watch for bubbles flowing down the electrolyte tube and out the bleed port. c. Allow about 2 ml of fill solution to escape through the port. Use a paper towel to absorb the liquid. d. Tighten the bleed screw. 13. Note the reference impedance, if this information is available on the instrument. It should be less than about 350kΩ. 14. If the reference impedance is high, air bubbles maybe trapped in the sensor. To clear air bubbles, hold the sensor with the bulb end pointing down and give it a few sharp shakes as though shaking down a fever thermometer. Keep the reference electrolyte tube connected to the reservoir while doing this. Repeat step 12 to bleed air bubbles. PN 3200HP PN 9601025 PN 34083-00 FIGURE 2. FIGURE 3. 3

Calibration CALIBRATION 1. Select two stable buffer solutions, preferably ph 7.0 and 10.0. Ideally, the calibration buffers should bracket the expected ph of the sample and be at least two ph units apart. Use the ring at the bottom of the back plate to hold the beaker containing the buffer. 2. Most ph meters offer automatic buffer recognition. Automatic buffer recognition means the instrument automatically calibrates using the correct ph for the buffer temperature. (The ph of a buffer, particularly one with alkaline ph, changes as temperature changes.) If the meter does not have automatic buffer recognition, refer to the label on the buffer bottle for a table of ph versus temperature. 3. Rinse the sensor with deionized water and immerse it in the first buffer. Gently swirl the sensor in the buffer for a few seconds. Allow the sensor and buffer to reach the same temperature. Once ph readings are stable, start the calibration. Follow the procedure in the analyzer instruction manual. 4. After the sensor has been calibrated in the first buffer, remove and rinse it with deionized water. Place the sensor in the second buffer and complete the calibration. 5. After the calibration is complete, check the slope and intercept of the sensor. The slope should be between 56 and 60 mv/ph and the offset should be between -20 and 20 mv. REPLACING THE ELECTROLYTE SOLUTION The reference electrolyte solution should last two to three months. To replace the electrolyte solution 1. Remove the reservoir bottle from the clip on the back plate. Turn the bottle upright. 2. Unscrew the cap and discard the remaining fill solution. To avoid twisting the electrolyte tube, turn the bottle, not the cap. To keep the cap and air inlet tube clean, use the electrolyte tube to hang the cap from the reservoir clip. 3. Pour 500 ml of reference fill solution (PN 9210391) into the reservoir. Replace the cap. Turn the bottle, not the cap. 4. Invert the bottle and reattach it to the clip. 5. Bleed air bubbles from the tube and sensor. a. Loosen the bleed screw until it is engaged by only about one thread. b. Watch for bubbles flowing down the electrolyte tube and out the bleed port. c. Allow about 2 ml of fill solution to escape through the port. Use a paper towel to absorb the liquid. d. Tighten the bleed screw to reseal bleed port. REPLACING THE CAPILLARY DISC The reference capillary junction is protected by a filter that prevents suspended solids from plugging the capillary. During normal operation, suspended solids will gradually coat the filter. Eventually, the electrolyte flow becomes too low, and the capillary disc must be replaced. Typical symptoms of low flow are an abnormally low ph reading and high reference impedance (> 600 kω). To replace the capillary disc 1. Remove the electrolyte reservoir from the clip on the back plate. Turn the reservoir upright. Disconnect the electrolyte tube from the reservoir cap. Place the shipping plug on the reservoir filter. 2. Disconnect the VP cable from the sensor. Remove the sensor from the flow cell. 3. Remove the capillary disc (PN 34132-00) from the storage vial and place it on a clean surface. Don t let the new capillary disc dry out. 4. Hold the sensor in a horizontal position with the capillary disc pointing up. With a small screw driver, gently pry the old disc and O-ring out of the sensor. 5. Place a new O-ring in the opening. 6. Put a few drops of deionized water in the port until liquid slightly overflows it. 7. Place the new capillary disc in the port, without touching the filter membrane. Use your finger tips to gently push the disc into place. The disc should easily slide into place. Do not touch the filter with your fingers as the transfer of oils from your skin will diminish the performance of the membrane. 4

Replacement Parts REPLACING THE CAPILLARY DISC CONT. 8. Remove the shipping plug from the reservoir filter. Attach the tube to the reservoir filter. 9. Place the reservoir back in the clip. 10. Bleed air bubbles from the tube and sensor. a. Loosen the bleed screw PN 9601025 until it is engaged by only about one thread. b. Watch for bubbles flowing down the electrolyte tube and out the bleed port. c. Allow about 2 ml of fill solution to escape through the port. Use a paper towel to absorb the liquid. d. Tighten the bleed screw. (PN 9601025) FIGURE 4. Replacing/Installing a junction into the 3200HP 5

Troubleshooting TROUBLESHOOTING Problem Cause Solution ph reading in error Noisy ph reading Air is blocking capillary causing low electrolyte flow. Capillary is plugged. Sensor was not properly calibrated. Sample flow is too high. To clear air bubbles, hold the sensor with the bulb end pointing down and give it a few sharp shakes as though shaking down a fever thermometer. Keep the electrolyte tube connected to the reservoir. Bleed air bubbles by loosening the screw in the air vent port. Replace capillary disc. Check buffers for freshness and replace buffers if necessary. Pay particular attention to alkaline buffers, which can become contaminated with atmospheric carbon dioxide. Review calibration procedure and repeat calibration. Adjust sample flow to between 60 and 240 ml/min (1 4 gph). Sensor is not properly oriented in flow cell. Orient sensor so that the capillary disc faces front. ph readings drift Reference electrolyte flow is too low. As flow drops, ph decreases. Air might be blocking the capillary or the capillary might be plugged. (Replace with PN 34132-00) Check to see if the filter is plugged. (If so, replace with PN 9160590). Sensor is dirty. Flow is not stable To clear air bubbles, hold the sensor with the bulb end pointing down and give it a few sharp shakes as though shaking down a fever thermometer. Keep the electrolyte tube connected to the reservoir. Bleed air bubbles by loosening the screw in the air vent port. If repeated efforts to clear air bubbles do not work, replace the capillary disc. Clean the sensor by rinsing the capillary filter with deionized water. Clean the ph glass bulb by rinsing with dilute hydrochloric acid. Recalibrate the sensor after cleaning. Fluctuations in sample flow can cause slight schanges in the ph reading. Keep flow constant. 6

Wiring WIRING Connector Pin Functions (Sensor end) FIGURE 4. Wire Functions for Variopol connector cable PN 23645-10,11 & 12 FIGURE 5. Model Xmt-P-10 Panel Mount Enclosure FIGURE 6. Model Xmt-P-11 Pipe/Surface Mount Enclosure Wiring 7

Wiring FIGURE 7. Model 5081-P Wiring FIGURE 8. Model 54e Wiring 8

Wiring FIGURE 9. Model 1055-10-22 Panel Mount Enclosure Wiring FIGURE 10. Model 1055-11-22 Pipe/Surface Mount Enclosure Wiring 9

Wiring FIGURE 11. Model 1055-01-10-22-32 Wiring 54e 5081-P FIGURE 12. Wiring Details with Remote J-Box and Preamp (PN 23555-00) 10

Wiring FIGURE 13. Model 1055-01-10-SI FIGURE 14. Model 1055-01-11-SI FIGURE 15. Model 1056-01-22-38-AN 11

The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. Credit Cards for U.S. Purchases Only. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2008