TrueRH Series HE-67xx Humidity Element with Temperature Sensors

Similar documents
CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

A99B Series Temperature Sensors

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

P66 Series Electronic Fan Speed Controls

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control

FX07 Field Controller

Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

HE-6800 Series Humidity Transmitters with Temperature Sensor

TE-6300P Series Temperature Sensors

T5000 T000 LCD Digital Fan Coil Thermostat

FX07 Field Controller

System 350 A350E Electronic Cooling Control

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Duct Humidity Transmitter

MCR1900 Media Converter 19-Slot Chassis

Humidity Sensor. Model HU-224/225

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued April 17, 2015

P70, P72, and P170 Series Controls for Dual Pressure Applications

Electronic Control Devices The European Product Catalogue 2007

Broadband Telecommunications Drop Amplifier

Y7230A CO 2 Alarm System

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

10 Multimeter. Users Manual

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

T600xxx-4 and T600xxx-4+PIR Series Thermostat Controllers

Triple Expansion Chassis

VG2000 Series Cast Iron Flanged Globe Valves

HIH-4000 Series Humidity Sensors

TC-9102 Series Surface Mount Temperature Controllers

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Electronic Control Devices The European Product Catalogue 2007

AXIS T81B22 DC 30W Midspan

CQM1-SF200/CS1W-SF200

Powers Controls TH 192 S Single Temperature Room Thermostat

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Duct Temperature Sensors

RM4TG20 three-phase network control relay RM4-T - range V

T7079A,B Solid State Remote Temperature Controllers

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Rosemount 333 HART Tri-Loop

Product/Technical Bulletin

CompactLogix Power Supplies Specifications

G670 Intermittent Pilot Ignition Controls

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

DUCT SMOKE DETECTOR D4120

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Rosemount 333 HART Tri-Loop

T-4000 Series Pneumatic Room Thermostats

System 350 A350R Electronic Temperature Reset Control (with Relay)

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Buckeye Detection Systems Fixed Detection Systems Application Survey

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Signal Manager Installation and Operation Manual

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

Description. Dimensions. Features. precision works better

16/32 Channel 1U Rack Mount CCTV Power Supply

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

BroadBand PowerShield. User Manual

OLS-2100 Occupancy Light Switch

Problem / Solution. The problem:

Model SRMD Setra Remote Monitoring Display

Typical Aluminum GFM Mass Flow Meter

Zebra RW 420 Mobile Battery Eliminator Kits

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Models SFP33 & SFP32 Pressure Transmitters

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Digital inductive conductivity transmitter

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Network Control Engine Product Bulletin

E-PDD Duct Smoke Detector Installation Sheet

HMI display Installation Guide

iosafe Solo External Hard Drive

Overview of Standards for CO Detection Products

FEATURES BODY DIA. MAX. Type M AWG 30: [0.254] Type C AWG 28: [0.320] Type T AWG 30: [0.254]

12V/15.0A SLA Battery Charger Specification

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

How To Use A Ds340 (Dsp)

THERMAL MANAGEMENT SOLUTIONS

How To Use A Cdm250 Digital Multimeter

Agilent 4338B Milliohm Meter

Transcription:

TrueRH Series HE-67xx Humidity Element with Temperature Sensors Product Bulletin HE-67xx Code No. LIT-216245 Issued November 4, 2009 Supersedes March 31, 2001 The HE-67xx Series Humidity devices house both a humidity and a temperature sensor in a wall or duct mount style. The humidity sensor is capable of measuring Relative Humidity (RH) over the entire range of 0 to 100%, and its All-Polymer construction provides improved resistance to chemical corrosion. The TrueRH product line delivers devices with RH accuracy of either ±2% or ±3% RH. TrueRH humidity elements produce voltage output signals proportional to measured humidity for humidity indication.temperature sensors are available in thinfilm nickel, thin-film platinum, and silicon. The Elements are powered with 14 to 30 VDC or 20 to 30 VAC and feature a user-selectable humidity output of 0 to 10 VDC or 0 to 5 VDC. Figure 1: HE-67xx-0N0BT Wall Mount Humidity Element and the HE-67xx-0N00P Duct Probe Humidity Element Table 1: Features and Benefits Features TrueRH All-Polymer Humidity Sensor National Institute of Standards and Technology (NIST) Traceable Calibration The 2% RH accurate model includes a NIST certificate of conformance Humidity and Temperature Sensors in One Unit User-selectable Output Voltage Range All-Plastic Material for Duct Probe Benefits Circuitry and calibration techniques for which patent protection is pending Patented sensing element provides accurate and reliable humidity sensing Tested, verified, and audited per NIST standards Documents higher precision for 2% models Eliminates the need for separate sensors and reduces installation time and cost Allows choice of standard voltage outputs for use with systems in service or new systems Improves thermal performance and complies with Underwriters Laboratories Inc. (UL) flammability ratings for plenum use; complies with Blue Angel (Germany) and TCO'95 (Sweden) environmental regulations TrueRH Series HE-67xx Humidity Element with Temperature Sensors Product Bulletin 1

Product Overview IMPORTANT: The HE-67xx Series Humidity Elements with Temperature Sensor are designed for use only as operating controls. Where failure or malfunction of the HE-67xx could lead to an abnormal operating condition that could cause personal injury or damage to the equipment or other property, other devices (limit or safety controls) or systems (alarm or supervisory) intended to warn of, or protect against, failure or malfunction of the HE- 67xx must be incorporated into and maintained as part of the control system. The HE-67xx humidity elements provide independent humidity and temperature signals for use in a wide range of sensing applications, and are suitable for use with most Heating, Ventilating, and Air Conditioning (HVAC) controllers. The humidity elements are a durable, cost-effective solution for humidity sensing. They are easy to install and factory calibrated to NIST standards. The ±2% models ship with NIST certificates of conformance to validate Johnson Controls use in demanding HVAC applications. The elements can operate in areas with little or no airflow, and recover after loss of power or saturation. The patented All Polymer humidity element is capable of sensing over the entire range of 0 to 100% RH; its construction provides resistance to corrosion in typical HVAC environments. The temperature sensor is isolated from and operates independently of the humidity sensor. The elements are available with three types of temperature sensors: thin-film nickel sensor that provides 1000 ohms of resistance at 70 F (21 C). silicon sensor that provides 1035 ohms of resistance at 77 F (25 C). thin-film platinum sensor that provides 1000 ohms of resistance at 32 F (0 C). The temperature and humidity information from the elements can be used to calculate enthalpy, important in determining an energy-efficient and cost-effective strategy. Space and duct humidity are also important factors in overall indoor air quality. The elements allow monitoring and comparing of humidity levels with those recommended in ASHRAE Standard 62-1999. See Figure 3 for the resistance versus temperature relationship for a nickel, silicon, or platinum temperature sensor. 1400 1300 1200 1100 Resistance (Ohms) 1000 900 800 700 600 0-18 Dimensions Platinum Nickel Silicon 20-7 40 4 60 16 80 27 100 38 Temperature, F/ C 120 49 Figure 2: Resistance Versus Temperature See Figure 4 or 5 for humidity element dimensions. 3.12 79 2.12 54 1.81 46 140 60 Figure 3: Wall Mount Humidity Element Dimensions, in. (mm) 2 TrueRH Series HE-67xx Humidity Element with Temperature Sensors Product Bulletin

3.28 83 3.25 83 2.02 51 Repair Information The wall mount and duct probe humidity elements are not field repairable. Refer to the Ordering Information section to order a replacement. Ordering Information Contact the nearest Johnson Controls representative to order a humidity element, and specify the desired product code number from Table 1. Refer to Table 2 for accessories available for the wall mount humidity elements. (There are none for the duct probe models.) 6.25 159 Diameter 0.98 25 Figure 4: Duct Probe Humidity Element Dimensions, in. (mm) Table 2: Humidity Elements Product Code Description RH Accuracy Number 2% 3% HE-67P2-0N0BT Wall mount humidity element with thin-film platinum temperature sensor X HE-67S2-0N0BT Wall mount humidity element with silicon temperature sensor X HE-67N2-0N0BT Wall mount humidity element with thin-film nickel temperature sensor X HE-67P2-0N00P Duct probe humidity element with thin-film platinum temperature sensor X HE-67S2-0N00P Duct probe humidity element with silicon temperature sensor X HE-67N2-0N00P Duct probe humidity element with thin-film nickel temperature sensor X HE-67P3-0N0BT Wall mount humidity element with thin-film platinum temperature sensor X HE-67S3-0N0BT Wall mount humidity element with silicon temperature sensor X HE-67N3-0N0BT Wall mount humidity element with thin-film nickel temperature sensor X HE-67P3-0N00P Duct probe humidity element with thin-film platinum temperature sensor X HE-67S3-0N00P Duct probe humidity element with silicon temperature sensor X HE-67N3-0N00P Duct probe humidity element with thin-film nickel temperature sensor X Table 3: Accessories for the Wall Mount Humidity Elements Product Code Number Description GRD10A plastic Guard with Baseplate and Mounting Ring T-4000-119 Allen-head ADjustment Tool (30/bag) TE-1800-9600 Wall Plate Adaptor Kit required for wallbox mounting TrueRH Series HE-67xx Humidity Element with Temperature Sensors Product Bulletin 3

Technical Specifications TrueRH Series HE-67xx Humidity Element with Temperature Sensor Product Bulletin Product TrueRH Series HE-67xx Humidity Element with Temperature Sensor Power Requirements 14 to 30 VDC or 20 to 30 VAC at 50/60 Hz, Class 2 Current Draw 3 ma with no load, 25 ma maximum Acceptable Wire Gauge 16 to 24 AWG (18 AWG recommended) Humidity Element Signal: 0 to 5 VDC or 0 to 10 VDC, 1,000 ohm maximum load at 77 F (25 C) Accuracy: HE-67x2: ±2% RH for 20 to 80% RH at 77 F (25 C) ±4% RH for 10 to 20% and 80 to 90% RH at 77 F (25 C) HE-67x3: ±3% RH for 20 to 80% RH at 77 F (25 C) ±5% RH for 10 to 20% and 80 to 90% RH at 77 F (25 C) Temperature Coefficient: 0.1 to 0.05% RH/ C at 5 C (41 F) to -0.07 to -0.21% RH/ C at 65 C (149 F) Temperature Sensors Thin-film Nickel: Silicon: Thin-film Platinum Electrical Connections Ambient Operating Conditions Survival Operating Conditions Accuracy: ±0.34 F (0.18 C) at 70 F (21 C) Reference Resistance: 1000 ohms at 70 F (21 C) Resistance Change: Approximately 3 ohms/ F (5 ohms/ C) Accuracy: ±1 F (0.6 C) at 70 F (21 C) Reference Resistance: 1035 ohms at 77 F (25 C) Resistance Change: Approximately 4 ohms/ F (8 ohms/ C) Accuracy: ±0.65 F at 70 F (±0.36 C at 21 C) Reference Resistance: 1000 ohms at 32 F (0 C) Resistance Change: Approximately 2 ohms/ F (4 ohms/ C) 3-position and 2-position screw terminal blocks 32 to 140 F (0 to 60 C) -20 to 140 F (-29 to 60 C) Ambient Storage Conditions -40 to 140 F (-40 to 60 C) Materials Wall Mount: Beige plastic cover with metal base and metal foil face plates Duct Probe: Blue plastic cover, housing, and probe Dimensions Shipping Weight Compliance Wall Mount (H x W x D) Duct Probe (H x W x D) Probe (L X D) 1.81 x 2.12 x 3.12 in. (46 x 54 x 79 mm) 3.28 x 3.25 x 8.27 in. (83 x 83 x 210 mm) 6.25 x 0.98 in. (159 x 25 mm) 0.6 lb (0.3 kg) Duct Probe 94-5V flammability rated per UL 94 Material United States UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment Canada UL LIsted, File E107041, CCN PAZX7, Under CAN/CAS C22.2 No. 205, Signal Equipment Europe CE Mark, EMC Directive 2004/108/EC Australia and C-Tick Mark, Australia/NZ Emissions Compliant New Zealand 4 TrueRH Series HE-67xx Humidity Element with Temperature Sensors Product Bulletin

The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. North American Emissions Compliance United States Emissions Compliance Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. Canadian Emissions Compliance Industry Canada Statement The term IC before the certification/registration number only signifies that the Industry Canada technical specifications were met. Le terme «IC» précédant le numéro d'accréditation/inscription signifie simplement que le produit est conforme aux spécifications techniques d'industry Canada. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2009 Johnson Controls, Inc. TrueRH Series HE-67xx Humidity Element with Temperature Sensors Product Bulletin 5 Published in U.S.A. www.johnsoncontrols.com