Innovative hospital components. To ensure that the air is clean and free of germs.

Similar documents
Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

Environmental Monitoring

CONTAMINATION CONTROL IN HOSPITALS. Isabelle Pautrel Ingénieur Clean Concept Patriarche & Co i.pautrel@patriarche.fr

SPECIAL APPLICATIONS

Procedures for the Effective Use of Biological Safety Cabinets

ENVIRONMENTAL MONITORING

Atlas Copco Quality Air Solutions. Compressed Air Filters

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Environmental Monitoring

Viledon HEPA and ULPA Filters The Patented Solution for Sterile Air and Clean Rooms. Product Overview

Qualification of Cleanrooms and Environmental Monitoring - Practical Approaches in Europe

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Laminar Flow Hoods and Booths

Ozone in Cooling Towers : Hygiene for us

Environmental Monitoring of Clean Rooms

EudraLex. The Rules Governing Medicinal Products in the European Union Volume 4

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

Risk Assessment: Biosafety Cabinet

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

DIF O.T. Ceiling filtration system for operating theatres

Both health-care facility classification and area classification, as per CSA, determine the design requirements.

Result: COMPLETE Report Date: 08-OCT-2012

HUBER Vacuum Rotation Membrane VRM Bioreactor

Spetec. Laminar Flow Box. Portable Clean Room Technology

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

MERO Floor Systems - CleanRoom

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Essam E. Khalil

Comparison between Decentralised and Centralised Air Conditioning Systems

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

Cartridge Filter Application Notes

Today, healthcare facilities must be prepared to face

PANDA SPRAY BOOTH FILTER INFORMATION

Innovation and Progress in Water Treatment Technology

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only

Molds and mildew are fungi that grow

How Does Fortron Air Conditioning Treatment Work?

SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER

MEDICLEAN. Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments. Weiss Klimatechnik GmbH Geräte- und Anlagenbau

Cleanroom Solutions Ltd T: F: E: W:

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division

Both health-care facility classification and area classification, as per CSA, determine the design requirements.

Kompressoren. Adsorption Dryer AD

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

IEQ-15 Air Distribution System

Industrial infrared heater IR For premises with large volumes and high ceilings

BSL3 and BSL4 Autoclaves. Laboratory Line

Checklist for a Physical Containment Level 2 (PC2) Laboratory Facility

A Guide to Trouble-Free Cooling Towers

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

We have been working in an ideal climate for thirty years.

Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

ASTACEA4 Inspect complex/central air conditioning systems

Mechanical shaft seal types and sealing systems

Element D Services Heating, Ventilating, and Air Conditioning

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

Under sill units. Type FSL-B-ZAS

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

lindab we simplify construction Air Handling Units Product Overview

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

clean and quiet dental

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

Innovent LASER Packaged Fresh Air Conditioning Units

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Everything you want to know about USP 797

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Clinic Washer-Disinfectors. Washer-Disinfector Line

Ducoterra Radiant Heating Panel Installation Manual

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Dehumidification Frequently Asked Questions

Cooking at the Speed of light!

Art Basel Miami Beach Dec Booth Design Regulations

National Food Safety standard of the People s Republic of China

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Facility Requirements for the elan2 Office Liquid Nitrogen Generator

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

applications laminar flow Laminar Flow Diffusers CRITICAL ENVIRONMENT LAMINAR FLOW: GENERAL

BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Make your home a healthier home

Chemical Fume Hoods. Environmental Health and Safety

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

MUELLER FALLING FILM CHILLERS

Healthcare Solutions Room Pressure Monitors and Controls

Bird and bat droppings

Liquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior

API Marine. BMS Presentation. Ballast Measurement Systems

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

EU GMP Annex 1 Update 2008: Airborne Particle Counting

Transcription:

Innovative hospital components. To ensure that the air is clean and free of germs.

Our products and services are used wherever there is a need to plan and implement innovative concepts for the cleanest possible air. Our experts make sure that the air in operating rooms is clean and germ-free. They know your needs, speak your language and develop individual, customized and professional solutions to meet your requirements.

We have the technology. And the required experience. We have extensive and solid know-how in the entire field of cleanroom technology. Our experts can draw on years of experience in product development for hospital components, gained from countless installation projects. Our design-and-build skills constitute the ideal credentials for successful projects and guarantee cost-effective solutions. Experience our solutions live Determination of the customers exact requirements is the basis for every solution and investment decision. Therefore, we have established CRIC, Alpiq s Clean Room Information Center. In an authentically replicated operating room, we present live demonstrations of low-turbulence laminar flow with the help of the CG sterile air diffuser in a 36 m 2 area. The CRIC competence center includes Authentic clean rooms Installation of various components in compliance with clean-room requirements Live demonstrations and tests of Alpiq s products Different types of wall systems, floor systems and ceiling systems Reference installations Laminar air flow (TAV) ceiling systems of type CG for ORs in compliance with hospital guideline SWKI 99-3 and the DIN 1946-4 standard The CRIC is also available to our customers for workshops and further training courses.

Our core components OP-3 000 OP-TAV-D/H-U (D = differential, H = homogeneous, U = direct air circulation) and OP-TAV-D/H of type CG, proven and yet future-oriented. CG sterile air diffuser For optimal air conditions in critical areas. DLA ceiling air outlet with suspended matter filter Alpiq DLA elimination of bacteria, viruses and dust particles. FLUAB lint separator Alpiq FLUAB installed in more than 3000 hospitals around the globe. Alpiq your partner for innovative research projects The CTI project «Building technology for the health care sector», sponsored by the Swiss innovation promotion agency, is a research project of the School of Engineering and Architecture at the Lucerne University of Applied Sciences and Arts and the Technical University of Berlin. We and our experts are significantly involved in this project as component and system manufacturers.

OP-3 000 the modern operating room: a sterile island. Sterility is crucial in operating rooms to protect patients from life-threatening infections. The OP-3 000 system for operating rooms meets the highest requirements regarding hygiene and applied physiology in compliance with hospital guideline SWKI 99-3 and the DIN 1946-4 standard. Depending on the kind of operation performed, the OP-3 000 system filters and cools down the air supplied through the large-scale CG sterile air outlet. At the same time, the reliable CG sterile air diffuser creates a (low-turbulence) laminar flow. This approach invisibly isolates the OR zone from the surrounding area and effectively prevents bacterially or virally contaminated air from penetrating into the operating area. During the operation, germ concentration per cubic meter of air is less than 10 CFU underneath the sterile air zone. The large OP-TAV systems of type CG 32/32 for more extensive protection enable expansion of the sterile OR zone so as to include material trays and instrument trays. OP-3 000 your cost advantage The OP-3 000 system with direct air circulation confines the costly sterile hospital areas to the OR supply air zone. The system is based on the air circulation principle, whereas primary air can be reduced to a minimum, depending on the sound pressure level inside the room. Primary air is treated in a central air conditioning system, then injected into the OR outlet as temperature-adjusted, humidityadjusted or quantity-adjusted air, according to the kind of operation performed. Compared to a conventional operating room solution, the OP-TAV-D/H-U system of type CG decreases investment costs and operating costs by up to 40 %.

The FLUAB lint separator extends your air conditioning system s operational life span considerably. All the benefits at a glance Complies with the DIN 1946-4 standard Easy to install 100% stainless steel Easy to clean Very high manufacturing quality Alpiq s FLUAB lint separator consists of a wire mesh separator element with torsion-resistant bordering and a chassis for channel mounting or wall mounting. It was specifically designed for areas with stringent hyg ienic requirements. It complies with the DIN 1946-4 standard and with the guidelines of the DIN 4783 standard. The FLUAB lint separator makes it possible for return air ducts and rooms connected to the OR via overflow openings to be protected against clothing fibers efficiently. The FLUAB lint separator is particularly impressive due to the absence of any protruding elements. The separator element is recessed so that the handles and the chassis are flush-mounted. This design protects staff and equipment by preventing snagging. Upon cleaning of the operating room, lint is removed from the lint separator and, if the degree of dirt accumulation renders it necessary, the device is also disinfected. From the front, the separator element can easily be removed from the chassis for this purpose, with no tools required. In order to protect staff and equipment, the separator element is recessed. We place great importance on flexibility and can provide any rectangular dimensions required.

DLA ceiling air outlet with suspended matter filter. All the benefits at a glance Manually adjustable, airtight shut-off damper Integrity testing und measurement of pressure differences, depending on the room Can be combined with each other Small Air outlets with a central nut Easy to maintain and disinfect DLA for clean supply air and return air Alpiq s DLA ceiling air outlet has integrated suspended matter filters. It is used for air filtration and diffusion from a single device. Bacteria, viruses and dust particles are eliminated directly before the air enters the room. This approach efficiently removes the system-related disadvantages and risks of central air filtration, such as cross-contamination via air ducts. Alpiq s DLA is used wherever the highest requirements must be met regarding purity of the air and low germ contamination, such as in hospitals (conventional ORs and rooms adjoining ORs, intensive care units, sterile zones and isolation zones) or laboratories (clean zones and clean work areas, filtration of toxic aerosols from return air). All the benefits at a glance Small Air inlet unit as lint separator Can be combined with each other Easy to maintain Alpiq DLE-A ceiling air inlet. Efficient protection of return air ducts. Alpiq s DLE-A ceiling air inlet with lint separator enables efficient protection of return air ducts against clothing fibers. The DLE-A s design complies with the DIN 1946-4 standard and with the guidelines of the DIN-4783 standard. The materials used are particularly important: the wire mesh chassis (lint separator) is made from stainless steel (14301). On the outer face, it is polished with 220 grit. Lint separators or virtually any customary outlet elements and diffusers with central mounting can be used as inlet elements. The air connection is realized by means of round connection nozzles in which throttle valves can be installed. These are accessible from within the room. Our DLE-A can be integrated into all common ceiling systems.

We measure the things that you don t see. The right quality of air has a positive effect on well-being, safety and productivity. We measure and analyze your air and provide the basis for specific solutions, no matter what problems you face. We also have a wealth of experience in certifying and recertifying clean rooms. Particle measurement DEHS scanning Filter performance levels Purity classes Recovery tests (recovery period) Particle measurement: when there is something in the air Clean rooms have to comply with specific requirements relating to particle concentration. We use a particle counter to identify impurities and we document the results. We have been providing this kind of service to well-known customers for years always in a reliable and neutral manner. Air values Airspeeds and the resulting quantities of supply air and return air Air change within the room (purification) Turbulence intensity (turbulent or laminar) Differential pressure Differential pressures between different rooms Differential pressures between a room and the atmosphere Differential pressures across filters Air values: when air flows are out of control If you control the air, you control the climate. We measure air flows, the laminar or turbulent air movements, and provide the required information. We know how to operate in laminar zones, how draughts can be identified and what specific actions can be taken. Differential pressure: when the next room is also important Differential pressure is an effective means to protect rooms from outside influences. A differential pressure is created on the basis of different air volume flows. This approach is used in the hospital sector as well as in the pharmaceutical industry and the electronic industry, as clean rooms and operating rooms in hospitals only function properly if predefined pressures are adhered to. We measure differential pressures between different rooms, between a room and the atmosphere and across filters.

Visualization Air flows in laminar zones (weighing cabinets, OR air outlets, etc.) Overpressures in rooms Visualization: when the problem is invisible We are able to visualize spatial air flows. In so doing, we can show our customers how room ventilation behaves in relation to the customers processes. Spatial air flow behavior is extremely varied. Due to the visualization of flows, weaknesses can be identified and specific measures can be taken to remove them. Hygienic certification Degree of protection in compliance with hospital guideline SWKI 99-3 and the DIN 1946-4 standard Turbulence intensity pursuant to the DIN 1946-4 standard Contact tests of surfaces Counting of germs in the air Hygienic certification: because protection of patients has utmost priority For reasons of patient safety, the protective effect in the sterile zone of OP-TAV ceiling systems of type CG must be verified. We are able to provide verification in compliance with hospital guideline SWKI 99-3 and the DIN 1946-4 standard with the required equipment. We also count microbiological germ numbers in the air and on surfaces. On the basis of these counts, operational procedures and cleaning processes are adjusted or optimized. In the pharmaceutical industry, these tests are absolutely essential and an important part of quality assurance. Comfort evaluation Temperatures and humidity in the immediate vicinity Sound pressure level in the room Illumination or light intensity CO content 2 Comfort evaluation: if well-being is disturbed In buildings where people work or spend their time off, these people s well-being depends on comfort. We know the criteria which determine comfort and we are aware of the critical values. In very little time, we can ascertain precisely why people don t feel well in a building. Quite often, small measures can eliminate great discomfort.

www.alpiq-intec.ch 11/09