Technical Information. Ventilation

Similar documents
06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

How To Get A Passive House

Energy Efficiency HOSPITALITY.

HVAC Processes. Lecture 7

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Energy Efficiency. Bars & RestauRants.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

FLEXIT S4 R S6 R S7 R

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Installation and maintenance instructions. Danfoss Vent

Unico Inverter. Unique and efficient.

KONRAD. Hybrid Fancoil Series

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

SWIMMING POOL HEAT PUMP Owners Manual

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

ELECTRIC CENTRAL HEATING FLOW BOILER

Split units TH with hermetic compressors

Operating instructions

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

USER S MANUAL HSC-24A

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Dehumidification Frequently Asked Questions

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

CADB and CADT-D / DI / DC Series

york air-conditioning products Residential & VRF News 2015

Celxia. a s. Artcool uses state-of-the art technology to assure customer satisfaction.

FULL DC INVERTER SYSTEMS

Dehumidifier D 850E. - Instruction manual version 02

3-2. Using the air conditioning system and defogger Automatic air conditioning system

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

REMOTE CONTROL MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

Horizontal ventilation units

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

We have been working in an ideal climate for thirty years.

Air Conditioning System

helosauna.com STEAM BATH PRODUCTS

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

94122E FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

Lesson 36 Selection Of Air Conditioning Systems

RPV - RP - RA air handling units

Topvex SX/C, Topvex TX/C. Air Handling Unit

CE6500 Energy Recovery Ventilator

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Glossary of Heating, Ventilation and Air Conditioning Terms

Technical data. Danfoss DHP-A

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

Installation, operation and maintenance manual TX 35A

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Process Alarm Solutions


Operation and Installation Manual. Max Series

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Bring the fresh in. Dedicated Outside Air Systems

Failure code manual. content

Operating Instructions Split System Air Conditioner

Innovent LASER Packaged Fresh Air Conditioning Units

RRV934. Multi-controller. Synco living

2014 Performance RAK-PPA/PPB. 19th December 2013 RAC Product Planning Division

Important Safeguards

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

Combi Unit Genius. The energy efficient Building Service Centre

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

User manual. 086U6297 Rev. 9 EN

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT.

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Industrial infrared heater IR For premises with large volumes and high ceilings

Zehnder Focus 200. Ventilation device

Samsung Room Air Conditioning

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

HEATER, AIR CONDITIONING AND VENTILATION

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

The Blakeslee Checklist of Air Conditioning Maintenance Tips. Get in your COMFORT ZONE

HVAC air curtains. Type InduAir

Transcription:

Technical Information Ventilation General description Capacity curves Technical data Service and operation Settings of air volume and temperature Accessories

VENTILATION 1 General description 1.01-1.01 2 Capacity curves 2.01-2.02 3 Technical data 3.01-3.01 4 Service and operation 4.01-4.01 5 Setting of air volume 5.01-5.02 and temperature 6 Accessories 6.01-6.01 With reservation for changes and misprints.

GENERAL DESCRIPTION 1 General description The ELITE series is the optimal solution to provide a pleasant indoor climate and a healthy environment in homes, offices and public buildings. The importance of a good indoor climate has been brought into focus in recent years, not least because new buildings are very well insulated and are now nearly completely air tight. Cases of asthma and allergy attacks are increasing, primarily since the introduction of double glazing a couple of decades ago. ELITE is a high-quality ventilation product providing a refreshing breeze of comfort to your home or workplace. Installation of an ELITE ventilation system not only purifies the air for pollen, dust and other damaging and harmful substances, it will also free your home from excessive moisture which is often the reason for steamedup windows, bad smell and damages like mould and dry rot. The ELITE ventilation system is easy to control. The control function is assured by a remote control unit that can be placed anywhere in the house. 1.01

CAPACITY DIAGRAMS 2 Capacity diagrams Elite 400 Air volume Adjusting step 8 7 6 Capacity diagram with F5 filters 5 Pa 4 3 2 1 m 3 /h Temperature efficiencies Temperature efficiencies % m 3 /h 2.01

2 CAPACITY DIAGRAMS Elite 800 Air volume Capacity diagram with F5 filters Adjusting step 8 7 6 5 Pa 4 3 2 1 m 3 /h Temperature efficiencies Temperature efficiencies % m 3 /h 2.02

TECHNICAL DATA 3 Technical data Model Elite 400 Elite 800 Air volume m 3 /h 400 800 Efficiency % 73 68 Power supply V/Hz 1x230/50 2x230/50 Max. power consumption W 1780 2900 Max. current consumption A 7,8 12,6 Electric heating element W 1500 2400 Filters supply/exhaust air F5/F5 F5/F5 Duct connection Ø mm 160 200 Sound level at a distance of 1 m db(a) 48 51 Weight kg 64 95 Dimensions (HxLxW) mm 600x1000x400 750x1100x500 The ELITE cabinet is made of 50 mm double-skinned insulated hot-dipped galvanized panels and it has an upper and a lower access door on the inspection side. To replace filter, open the upper access door. To clean the exchanger, open both the upper and the lower access doors. ELITE 400 is suitable for use in offices and private homes up to 200 m 2. ELITE 800 is suitable for use in public buildings, offices and larger homes up to 400. mm A B C D E F G H I Elite 400 1000 400 600 160 200 152 205 243 240 Elite 800 1100 500 750 200 250 195 333 222 275 3.01

SERVICE AND OPERATION 4 Service and operation The control unit is delivered together with the ventilation unit and it is very easy to operate. The entire operation can be carried out by means of one pushbutton, allowing selection of air volume. By pressing the button quickly, the air volume is increased with one step at a time. If the push-button is held down for 5 seconds, it switches over to OFF. A green light diode indicates which air volume has been chosen. LOW or MEDIUM are intended for normal running speeds, whereas HIGH is intended for quick air change. In order to save energy, the control system automatically switches back to the initial setting two hours after it was set to HIGH. An extra three-coloured light diode indicates the actual running mode. Green light: Plant is OK, ventilation running without heat. Yellow light: Plant is OK, running, but heat is switched on. Red light: Plant stopped because heating element is too hot. Info light flashes: Filter has to be checked and perhaps replaced. The time interval for the filter guards is 6 months. To reset the time interval, keep down the button for 15 seconds. Summer operation The ELITE control unit is able to distinguish between summer and winter. When the fresh air temperature is higher than 15 C, the control system will interpret this as summer and heat is switched off. This reduces the energy consumption during warm periods of the year. Frost protection At extremely low fresh air temperatures, ventilation is automatically reduced, once it has been registered that the heating coil is not able to maintain the required temperature. This reduces energy consumption during cold periods of the year. This function is not active in HIGH position, which is limited in time. Defrosting of the heat exchanger If the temperature after the heat exchanger/exhaust air is under 5 C, there is a risk of ice formation on the heat exchanger. If so, ice formation will be allowed for one hour, after which the supply air fan and additional heat, if any, will be stopped for two minutes to let the heat exchanger be defrosted by return air. The drawing below shows the principle of a ventilation plant with heat exchanger. Hot exhaust air Fresh air intake Supply air Final exhaust air 4.01

SETTING OF AIR VOLUME AND TEMPERATURE 5 Setting of air volume and temperature By means of the purpose designed electronic control unit it is possible to match air volume and heat with a view to obtaining the highest possible comfort without exaggerated use of energy. By means of the 3-stage electric heating coil the electronic control can provide the required room temperature at any time. The temperature can be set between 17 C and 21 C. Therefore the ELITE unit is primarily intended as an air change plant and heating must be provided by other sources of heat. The following air volumes can be selected: LOW - MEDIUM HIGH. LOW and ME- DIUM there is a free choice between 7 speeds, making it possible to select the air volume that matches the requirements best. position HIGH the plant is running at max. air volume. The diagram below shows the setting of the air volume Air Setting of Voltage Power consumption volume dipswitches for fans (A) (A) (Volt) 1 2 3 Elite 400 Elite 800 1 69 0,11 0,19 2 92 0,20 0,35 3 115 0,31 0,55 4 138 0,45 0,81 5 161 0,61 1,09 6 184 0,78 1,40 7 207 0,96 1,72 8 230 1,13 2,03 The diagram shows the settings of dipswitches 1-2-3. The same settings/values apply for dipswitches 4-5-6. The dipswitches 1-2-3 control low speed (LOW SPEED) The dipswitches control medium speed (MEDIUM SPEED) (HIGH SPEED) = 230 V As standard low fan speed is set at 1 and medium fan speed is set at 5. As standard ELITE ventilation units are fitted with two heating elements, each with 3 steps. For Elite 400: 500W - 1000W - 1500W. For Elite 800: 800W - 1600W - 2400W. 5.01

5 SETTING OF AIR VOLUME AND TEMPERATURE The diagram below shows the setting of the supply air volume. Supply air temperature 8 C* 17 C 19 C 21 C Setting of dipswitches 7 8 The diagram above shows the combination possibilities for getting the most suitable temperature for the given situation. The dipswitches 7-8 control the supply air temperature. Standard temperature is pre-set at 21 C. *8 C is used as frost protection of the heating coil. (The heating coil is extra accessory). As standard the unit is pre-set to keep a supply air temperature of 21 C. This means that the sensor in the supply airflow is active and controls the heat and the fan in order to keep a constant temperature of 21 C. If the supply air temperature cannot be kept at 21 C, even if the heat is switched on at full load, then the fan speed is gradually lowered until the required temperature is reached. ce the fan speed is so low that the supply air temperature exceeds 21 C, the fan speed is gradually increased again by one step every minute. After that heat steps will be gradually lowered as long as the temperature remains at 21 C or more. 5.02

ACCESSORIES 6 Accessories Pollen filter - F9 Pollen filters are very effective when it comes to small particles such as dust, pollen and other harmful substances. Pollen filters are recommended in case of asthma and allergy tendences. Fire thermostat Protects against fire. The fire thermostat is set to f.inst. 40 C and is built into the exhaust air duct. Switches off the plant if the exhaust air temperature exceeds 40 C. Room thermostats for HEAT and COOL functions With the HEAT function you can maintain a minimum temperature in a room. With the COOL function you can bring the temperature down to the required level. Water heating coil Water heating coils 2RR are available as an alternative to the built in electric heating coils. Water heating coil for Elite 400 Air output Water in/out Heat output Air temp. Air temp. Water (m 3 /h) ( C) (kw) in( C) out( C) resistance KPA 200 80/60 2,6 5 41,0 0,9 200 70/50 2,1 5 34,7 0,6 200 70/40 1,8 5 29,9 0,2 200 60/40 1,7 5 28,5 0,4 Water heating coil for Elite 800 Air output Water in/out Heat output Air temp. Air temp. Water (m 3 /h) ( C) (kw) in( C) out( C) resistance KPA 400 80/60 5,0 5 40,4 4,0 400 70/50 4,2 5 34,6 3,0 400 70/40 3,6 5 30,6 1,2 400 60/40 3,4 5 28,7 2,1 Frost thermostat - Danfoss KP 75 For frost protection of the water heating coil when the plant is off. System 1: System 2: External thermostat for manual control of the supply air temperature A capillary tube thermostat is available for manual control of the supply air temperature. External thermostat for automatic control of the supply air temperature Room thermostat (setting area 15-30 C) - (0-10V DC) Duct sensor Two-way valve - to be selected on basis of the K VS values below Valve actuator - (2-10V) Transformer - (220V / 24V AC / 10,5VA) K VS values for selecting two-way valves: Elite 400 Elite 800 District heating K VS 0,16 K VS 0,4 Boiler plant K VS 0,4 K VS 0,63 6.01

Comfortable surroundings in any climate Since 1958 Dantherm Air Handling has developed and produced climate control and air handling solutions that ensure optimum conditions for people and sensitive equipment alike. No climate is too extreme for us to handle from the bitter cold at the North and South Poles to the searing heat of the Sahara. Our core business areas are dehumidification, heating, air conditioning, ventilation and electronics cooling. Innovative, durable and cost-efficient products have secured us a position as a leading global manufacturer of stationary and mobile climate control units. And we are forever pursuing new techniques that will improve our solutions and ultimately your projects. Our Head ice is located in Denmark, and we have companies in Denmark, Norway, Sweden, the United Kingdom, the United States and China, with an extensive European dealer network. Dantherm Air Handling is part of the Dantherm A/S group. HEAD OFFICE COMPANIES Dantherm Air Handling Holding A/S Marienlystvej 65 DK-7800 Skive Denmark Tel.: +45 9614 3700 Fax: +45 9614 3800 E-mail: dantherm.dk@dantherm.com www.dantherm-air-handling.com DENMARK Dantherm Air Handling A/S Marienlystvej 65 DK-7800 Skive Denmark Tel.: +45 9614 3700 Fax: +45 9614 3800 E-mail: dantherm.dk@dantherm.com www.dantherm-air-handling.com NORWAY Dantherm Air Handling AS Løkkeåsveien 26 N-3138 Skallestad Norway Tel: +47 33 35 16 00 Fax: +47 33 38 51 91 E-mail: dantherm.no@dantherm.com www.dantherm-air-handling.no CHINA Dantherm Air Handling (Suzhou) Co., Ltd. Bldg. # 9, No. 855 Zhu Jiang Rd. Suzhou New District, Jiangsu 215219 Suzhou China Tel.: +86 512 6667 8500 Fax.: +86 512 6667 8501 E-mail: dantherm.cn@dantherm.com www.dantherm-air-handling.com.cn ENGLAND Dantherm Air Handling Ltd. 12 Windmill Business Park Windmill Road Clevedon North Somerset BS21 6SR United Kingdom Tel.: +44 (0) 1275 876851 Fax: +44 (0) 1275 343086 E-mail: dantherm.co.uk@dantherm.com www.dantherm-air-handling.co.uk USA Dantherm Air Handling Inc. 4260 Orchard Park Blvd, Spartanburg South Carolina 29303-4400 USA Tel.: +1 864 595 9800 Fax: +1 864 595 9810 E-mail: dantherm.usa@dantherm.com www.dantherm-air-handling.us SWEDEN Dantherm Air Handling AB Virkesgatan 5 SE-614 31 Söderköping Sweden Tel.: +46 (0) 121-130 40 Fax: +46 (0) 121-133 70 E-mail: infose@dantherm.com www.dantherm-air-handling.se 12.09.500 THORVIG TRYK, Skive