SECTION PRECAST ARCHITECTURAL CONCRETE

Similar documents
SECTION PRECAST CONCRETE STRUCTURES

Division 4 Section Concrete Masonry Specifications

SPECIFICATION Section Insulated Precast Concrete Wall Panels

Guide Specification Precast Concrete Products

GUIDE SPECIFICATIONS FOR PRECAST CONCRETE PRODUCTS

MeltonStone Cast Stone Product Specifications

SPECIFICATION Section Structural Precast / Prestressed Concrete

PART 1 GENERAL 1.1 SECTION INCLUDES

1. The General conditions of the Contract and Supplementary General Conditions apply to this Division, except as qualified herein and/or excluded.

DENVER MODEL 30 X 30 SPECIFICATIONS

These recommendations generally follow the Construction Specifications Institute (CSI) Master Format.

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

GUIDELINE SPECIFICATIONS

PCI BIG BEAM COMPETITION

Example Specification for Concrete using Current Building Code Requirements

Section 8.1 Volume I QUALITY ASSURANCE PROGRAM OF PRECAST PRESTRESSED CONCRETE PRODUCTS

Preformed Metal Roofing and Siding

COLORADO MODEL. 35 x 65 SPECIFICATIONS

SECTION PREFORMED METAL STANDING SEAM ROOFING

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION METAL WALL PANELS

Concrete Specification for Cooling Tower and Basin

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION WINDOW WASHING SYSTEMS

ATLANTA MODEL SPECIFICATIONS

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

Code of Standard Practice for Timber Frame Structures

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 888 PORTLAND CEMENT CONCRETE PAVEMENT USING QC/QA.

SECTION 1 GENERAL REQUIREMENTS

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

City of San Diego, CWP Guidelines

Chapter 3 Pre-Installation, Foundations and Piers

SECTION PRECAST CONCRETE UTILITY STRUCTURES

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

GUIDELINES FOR POLISHED CONCRETE FLOORS A Guide for Integrally Colored, Dyed and Stained Polished Floors

Precast Concrete Insulated Sandwich Wall Panels

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

Wastewater Capital Projects Management Standard Construction Specification

Architectural Concrete Masonry

2. Division 05 Structural Steel Framing for steel framework requirements

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

PART E SPECIFICATIONS

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

LAYING BLOCK AND BRICK

SECTION PLANT-PRECAST ARCHITECTURAL CONCRETE

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

GUIDE SPECIFICATION FOR PLANT-PRECAST CONCRETE PRODUCTS

James M. Pleasants Company

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

High Strain Dynamic Load Testing of Drilled Shafts

Dubai Municipality Standard DMS 1: Part 5: 2004

SECTION STANDING SEAM METAL ROOF

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

(B) Reinforcing and Tie Bars shall conform to the requirements of Mn/DOT 3301 unless otherwise shown on the Contract Drawings.

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SECTION STANDING SEAM METAL ROOFING

ITEM # OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT

Shotcrete Quality Control and Testing for an Underground Mine in Canada

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

SECTION GLASS FIBER REINFORCED CONCRETE (GFRC)

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

Acceptance Codes APPENDIX - A. Acceptance Criteria

SECTION STORM DRAINAGE SYSTEM

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

PROPERTIES AND MIX DESIGNATIONS

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

1.02 SYSTEM DESCRIPTION

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Mass Concrete. Robert Moser CEE8813A Material Science of Concrete. Definitions & Standards, Thermal Cracking, and Temperature Rise

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

1.5 Concrete (Part I)

INDEX. Sec. No. Items Page Nos.

SECTION GROUND WATER STORAGE TANKS

Reproduced with the permission of the American Welding Society (AWS), Miami, Florida - 09/15/ Stud Welding

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Transcription:

New Football Stadium 03.45.00-1 PART 1 GENERAL 1.01 SECTION INCLUDES A. Architectural precast concrete. B. Supports, anchors, and attachments. 1.02 RELATED REQUIREMENTS A. Section 03.20.00 - Concrete Reinforcing. SECTION 03.45.00 PRECAST ARCHITECTURAL B. Section 03.30.00 - Cast-in-Place Concrete: Admixtures. C. Section 04.20.00 - Unit Masonry. D. Section 07.62.00 - Sheet Metal Flashing and Trim: Reglets recessed in units. E. Section 07.92.00 - Joint Sealants: Sealing perimeter and intermediate joints. 1.03 REFERENCE STANDARDS A. ACI 301 - Specifications for Structural Concrete; American Concrete Institute International; 2010 (Errata 2012). B. ACI 318 - Building Code Requirements for Structural Concrete and Commentary; American Concrete Institute International; 2011. C. ASTM A36/A36M - Standard Specification for Carbon Structural Steel; 2014. D. ASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products; 2015. E. ASTM A153/A153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 2009. F. ASTM A325 - Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength; 2014. G. ASTM A325M - Standard Specification for Structural Bolts, Steel, Heat Treated 830 MPa Minimum Tensile Strength (Metric); 2014. H. ASTM A563 - Standard Specification for Carbon and Alloy Steel Nuts; 2007a (Reapproved 2014). I. ASTM A563M - Standard Specification for Carbon and Alloy Steel Nuts [Metric]; 2007. J. ASTM C31/C31M - Standard Practice for Making and Curing Concrete Test Specimens in the Field; 2012. K. ASTM C143/C143M - Standard Test Method for Slump of Hydraulic-Cement Concrete; 2012. L. ASTM C150/C150M - Standard Specification for Portland Cement; 2012. M. ASTM C260/C260M - Standard Specification for Air-Entraining Admixtures for Concrete; 2010a. N. ASTM C330/C330M - Standard Specification for Lightweight Aggregates for Structural Concrete; 2014. O. ASTM C618 - Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use as a Mineral Admixture in Concrete; 2012. P. ASTM C979/C979M - Standard Specification for Pigments for Integrally Colored Concrete; 2010. Q. ASTM C989/C989M - Standard Specification for Slag Cement for Use in Concrete and Mortars; 2013.

New Football Stadium 03.45.00-2 R. ASTM F959 - Standard Specification for Compressible-Washer-Type Direct Tension Indicators for Use with Structural Fasteners; 2013. S. AWS D1.1/D1.1M - Structural Welding Code - Steel; American Welding Society; 2011 w/errata. T. AWS D1.4/D1.4M - Structural Welding Code - Reinforcing Steel; American Welding Society; 2011. U. IAS AC157 - Accreditation Criteria for Fabricator Inspection Programs for Reinforced and Precast/Prestressed Concrete; 2010. V. PCI MNL-117 - Manual for Quality Control for Plants and Production of Architectural Precast Concrete Products; Precast/Prestressed Concrete Institute; 2007. W. PCI MNL-120 - PCI Design Handbook - Precast and Prestressed Concrete; Precast/Prestressed Concrete Institute; Seventh Edition, 2010. X. PCI MNL-122 - Architectural Precast Concrete; Precast/Prestressed Concrete Institute; 2007, Third Edition. Y. PCI MNL-123 - Design and Typical Details of Connections for Precast and Prestressed Concrete; Precast/Prestressed Concrete Institute; 1988, Second Edition. Z. PCI MNL-135 - Tolerance Manual for Precast and Prestressed Concrete Construction; Precast/Prestressed Concrete Institute; 2000. 1.04 ADMINISTRATIVE REQUIREMENTS A. Preinstallation Meeting: Convene one week prior to commencing work of this section. 1.05 SUBMITTALS A. See Section 01.30.00 - Administrative Requirements, for submittal procedures. B. Product Data: Manufacturer's information on accessory products, including pigments, admixtures, inserts, plates, etc. C. Shop Drawings: Indicate layout, unit locations, configuration, unit identification marks, reinforcement, integral insulation, insulated panel system connectors, connection details, support items, location of lifting devices, dimensions, openings, and relationship to adjacent materials. Provide erection drawings. 1. Include details of mix designs. 2. Include structural design calculations. D. Fabricator's Qualification Statement: Provide documentation showing precast concrete fabricator is accredited under IAS AC157. E. Sustainable Design Reporting: If any fly ash, ground granulated blast furnace slag, silica fume, rice hull ash, or other waste material is used in mix designs to replace Portland cement, submit the total volume of concrete, mix design(s) used showing the quantity of Portland cement replaced, reports showing successful cylinder testing, and temperature on day of pour if cold weather mix is used; use Material Content Form. F. Maintenance Data: Indicate surface cleaning instructions. 1.06 QUALITY ASSURANCE A. Design Engineer Qualifications: Design precast concrete units under direct supervision of a Professional Structural Engineer experienced in design of precast concrete and licensed in Tennessee. B. Fabricator Qualifications: 1. Firm having at least 5 years ofdocumented experience in production of precast concrete of the type required. 2. Plant certified under Precast/Prestressed Concrete Institute Plant Certification Program; product group and category A1 - Architectural Precast Concrete.

New Football Stadium 03.45.00-3 3. Fabricator Qualifications: Precast concrete fabricator accredited by IAS according to IAS AC157. C. Welder Qualifications: Qualified within previous 12 months in accordance with AWS D1.1/D1.1M and AWS D1.4/D1.4M. 1.07 MOCK-UP A. Construct temporary mock-up, 4 feet long by 2 feet wide, with lifting device, and attachment points, and finish in accordance with approved sample. B. Locate where directed. C. Mock-up may not remain as part of the Work. 1.08 DELIVERY, STORAGE, AND HANDLING A. Handling: Lift and support precast units only from support points. B. Blocking and Lateral Support During Transport and Storage: Use materials that are clean, non-staining, and non-harmful to exposed surfaces. Provide temporary lateral support to prevent bowing and warping. C. Protect units to prevent staining, chipping, or spalling of concrete. D. Mark units with date of production in location that will be concealed after installation. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Architectural Precast Concrete: 1. Any manufacturer holding a PCI Group A Plant Certification for the types of products specified; see www.pci.org. 2. Substitutions: See Section 01.60.00 - Product Requirements. 2.02 PRECAST UNITS A. Precast Architectural Concrete Units: Comply with PCI MNL-120, PCI MNL-122, PCI MNL-123, PCI MNL-135, and ACI 318. 1. Concrete Face Mix: Minimum 5000 psi, 28 day strength, air entrained to 5 to 7 percent; comply with ACI 301. 2. Design Loads: Static loads, anticipated dynamic loading, including positive and negative wind loads, thermal movement loads, and erection forces as defined by applicable code. 3. Calculate structural properties of units in accordance with ACI 318. 4. Accommodate construction tolerances, deflection of building structural members, and clearances of intended openings. 5. Provide connections that accommodate building movement and thermal movement and adjust to misalignment of structure without unit distortion or damage. B. Finish Type A: Ensure exposed-to-view finish surfaces of precast units are uniform in color and appearance. 2.03 REINFORCEMENT A. Comply with requirements of Section 03.20.00. 2.04 MATERIALS A. Cement: ASTM C150/C150M, Type I - Normal Portland type. B. Other Cementitious Materials: 1. Fly Ash or Natural Pozzolans: Comply with ASTM C618.

New Football Stadium 03.45.00-4 2. Ground Granulated Blast Furnace Slag: ASTM C989/C989M. C. Fine and Coarse Structural Aggregates: ASTM C33. D. Lightweight Structural Aggregate: ASTM C330. E. Surface Finish Aggregate: Conforming to sample in office of Architect. F. Color Additives: Pure, concentrated mineral pigments specifically intended for mixing into concrete and complying with ASTM C979/C979M. 1. Color(s): As selected by Architect from manufacturer's full range. G. Water: Clean and not detrimental to concrete. H. Air Entrainment Admixture: ASTM C260/C260M. I. Grout: 1. Non-shrink, non-metallic, minimum 10,000 psi, 28 day strength. 2.05 SUPPORT DEVICES A. Connecting and Support Devices; Anchors and Inserts: ASTM A36/A36M steel; hot-dip galvanized in accordance with ASTM A153/A153M. 1. Clean surfaces of rust, scale, grease, and foreign matter. 2. Galvanize after fabrication in accordance with requirements of ASTM A123/A123M. B. Bolts, Nuts, and Washers: ASTM A325 (A 325M) heavy hex structural bolts, Type 1, plain, with matching ASTM A563 (A563M) nuts, and washers as follows: 1. Compressible Direct Tension Indicators: ASTM F959, Type 325. C. Primer: Zinc rich type. 2.06 ACCESSORIES A. Bearing Pads: High density plastic; Shore A Durometer ; 1/8 inch thick, smooth both sides. B. Reglets: Specified in Section 07.62.00. 2.07 FABRICATION A. Fabricate in conformance with PCI MNL-117 and PCI MNL-135. B. Maintain plant records and quality control program during production of precast units. Make records available upon request. C. Use rigid molds, constructed to maintain precast unit uniform in shape, size, and finish. D. Maintain consistent quality during manufacture. E. Fabricate connecting devices, plates, angles, items fit to steel framing members, inserts, bolts, and accessories. Fabricate to permit initial placement and final attachment. F. Embed reinforcing steel, anchors, inserts plates, angles, and other cast-in items. G. Place recessed flashing reglets continuous and straight. H. Locate hoisting devices to permit removal after erection. I. Cure units to develop concrete quality, and to minimize appearance blemishes such as non-uniformity, staining, or surface cracking. J. Minor patching in plant is acceptable, providing structural adequacy and appearance of units is not impaired. 2.08 FABRICATION TOLERANCES A. Conform to PCI MNL-117 and PCI MNL-135.

New Football Stadium 03.45.00-5 2.09 SOURCE QUALITY CONTROL A. Provide testing and analysis of concrete mix. B. Take 4 concrete test cylinders for every 10 cu yd of concrete placed; make and cure in accordance with ASTM C31/C31M. C. Take 1 slump tests for every 100 test cylinders in accordance with ASTM C143/C143M. D. Take one air entrainment test cylinders for each set of exterior concrete test cylinders taken. E. Take water absorption test in accordance with PCI MNL-117. PART 3 EXECUTION 3.01 EXAMINATION A. Verify that building structure, anchors, devices, and openings are ready to receive work of this section. 3.02 PREPARATION A. Provide for erection procedures and induced loads during erection. Maintain temporary bracing in place until final support is provided. 3.03 ERECTION A. Erect units without damage to shape or finish. Replace or repair damaged panels. B. Erect units level and plumb within allowable tolerances. C. Align and maintain uniform horizontal and vertical joints as erection progresses. D. When units require adjustment beyond design or tolerance criteria, discontinue affected work; advise Architect. E. Weld units in place. Perform welding in accordance with AWS D1.1/D1.1M. F. Provide non-combustible shields during welding operations. G. Touch-up field welds and scratched or damaged primed painted surfaces. H. Set vertical units dry, without grout, attaining joint dimension with lead or plastic spacers. Pack grout to base of unit. I. Exposed Joint Dimension: 1/2 inch. Adjust units so that joint dimensions are within tolerances. 3.04 TOLERANCES A. Erect members level and plumb within allowable tolerances. Conform to PCI MNL-135, except as specifically amended below. 1. Plan Location from Building Grid Datum: Plus or minus 3/8 in. 2. Top Elevation from Nominal Top Elevation: Plus or minus 3/8 inch. 3. Maximum Plumb Variation Over Height of Structure or 100 ft (whichever is less): Plus or minus 1/2 inch. 4. Exposed Joint Dimension: Plus or minus 3/16 inch. 5. Maximum Jog in Alignment of Matching Faces or Edges: Plus or minus 3/16 inch. 6. Differential Bowing or Camber as Erected Between Similar Adjacent Members: Plus or minus 3/16 inch. END OF SECTION