Heating Controller. Building Technologies HVAC Products

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

RRV934. Multi-controller. Synco living

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

OZW30. Central Unit SYNERGYR

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Flush-mounted room thermostats

HERZ-Thermal Actuators

Digital input modules

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TX OPEN RS232/485 module

Adjustable room thermostat for heating only or cooling only systems

Smile. The All-In-One Heating Controller

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Room Temperature Sensors

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Air damper actuators

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Electronic Control Devices The European Product Catalogue 2007

OZS Web server. For LPB/BSB plants

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

OZW V2.0. Web server. Synco TM, Synco TM living

Electronic Control Devices The European Product Catalogue 2007

Voltage Regulator SPAU 341 C. Product Guide

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

TMS TANK MANAGEMENT SYSTEM

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

HVAC central apartment unit with consumption data acquisition

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

MOUNTING AND OPERATING INSTRUCTIONS

ACS-30-EU-EMDR-10-MOD

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Thyristor-controlled power supplies and battery chargers

Duct Humidity Transmitter

AXIS T81B22 DC 30W Midspan

Cooling with CHW (fan coil Heating with LTHW radiator Modulating control of heating and cooling valve Automatic or manual fan control

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

M1000 Process Alarm Monitor

Answers for infrastructure. HVAC control with Synco simple and energy-efficient

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ELECTRIC CENTRAL HEATING FLOW BOILER

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Remote Monitoring and REC 501 Control Unit Product Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Quick Connect. quick - simple - efficient.

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

PXM20-E. Operator unit DESIGO PX

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

RVS RVS AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Heat pump controller User manual. Siemens Switzerland Ltd HVAC Products

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Safety Manual BT50(T) Safety relay / Expansion relay

Flush-mount room temperature sensor AQR2531ANW.

FIREDEX Conventional Fire Panels

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HCR3.2/.. Chipcard reader HOTEL SOLUTION

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

SENTRON Switching and Protection Devices Air Circuit Breakers

Digital inductive conductivity transmitter

1 General information

Thermostat with display

Product and Application Description

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

flexotron 800: Electronic ventilation, air-conditioning and heating controller

TCR easy Plus Alarm. Operating Instructions

J TB/TW Temperature limiter, temperature monitor

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Technical Information

User Manual THR840DUK Digital Thermostat

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Power Meter Series 700

HVAC central apartment unit with consumption data acquisition

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

T7560A,B,C Digital Wall Module

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

IntesisBox KNX LG Air Conditioning

Problem / Solution. The problem:

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Transcription:

2 510 District Heating Controller for 1 heating circuit and d.h.w. heating RVD120 RVD140 ultifunctional heating controller for use in district heating substations and district heating plants with odbus communication. Suited for one heating circuit with d.h.w. heating in instantaneous systems or with storage tank. Eight programmed plant types. Operating voltage AC 230 V. Use lant: Heat exchanger in the district heating substation Buildings: Residential and non-residential buildings with own district heating connection and d.h.w. heating ypes of space heating systems: All common heating systems, such as radiator, convector, underfloor and ceiling heating systems, or radiating panels ypes of d.h.w. heating systems: D.h.w. storage tanks or instantaneous systems Common or separate heat exchangers for heating circuit and d.h.w. heating D.h.w. heating with electric immersion heater and solar collector CE1N2510en 09.11.2009 Building echnologies

Functions Heating circuit control Weather-compensated flow temperature control, mixing valve with 3-position actuator Weather-compensated flow temperature control with room temperature influence, mixing valve with 3-position actuator Room temperature-compensated flow temperature control, mixing valve with 3- position actuator Demand-dependent control of the common flow D.h.w. heating D.h.w. heating via heat exchangers in storage tanks Instantaneous d.h.w. heating via heat exchanger with or without mixing valve in the secondary circuit D.h.w. heating with electric immersion heater and solar collector Additional functions Quick setback Automatic heating limit (ECO function) Frost protection (for the building, plant, and d.h.w.) Annual clock for annual holidays, with automatic summer-/wintertime changeover Independent time switch programs for room heating and d.h.w. ump kick Idle heat function in the case of instantaneous d.h.w. heating via the parallel heat exchanger Flow switch with adjustable load limit, protection against tampering and adaptation to the seasons aximum limitation of return temperature differential (DR-limitation) Relay and sensor tests Remote operation via room unit Refill function Communication via odbus ype summary Description Documentation in languages Key feature roduct no. Stock number District heating and d.h.w. controller District heating and d.h.w. controller District heating and d.h.w. controller District heating and d.h.w. controller German, French, English, Italian, Danish, Finnish, Swedish olish, Czech, Greek, Russian, Bulgarian, Romanian German, French, English, Italian, Danish, Finnish, Swedish olish, Czech, Greek, Russian, Bulgarian, Romanian Supports plant types no. 1 3 RVD120-A S55370-C109 RVD120-C S55370-C110 Supports plant types no. 1 8 RVD140-A S55370-C113 RVD140-C S55370-C114 Ordering When ordering, give the roduct no. according to "ype summary" and the Language code letter (-A or -C) for the operating instructions and the installation instructions in the requested language. Examples: RVD120-A for English; RVD140-C for olish Sensors, room unit, actuators and valves must be ordered as separate items. 2/14 Building echnologies 09.11.2009

roduct documentation ype of documentation Classification number art number Basic Documentation 2510 Operating instructions (languages: B2510 74 319 0683 0 de, en, fr, it, da, fi, sv ) Operating instructions (languages: B2510 74 319 0684 0 pl, cs, el, ru, bu, ro) Installation instructions (languages: G2510 74 319 0681 0 de, en, fr, it, da, fi, sv) Installation instructions (languages: G2510 74 319 0682 0 pl, cs, el, ru, bu, ro CE Declaration of Conformity 2510 Environmental Declaration E2510 Equipment combinations Suitable sensors and room units Suitable actuators Communication Flow, return and d.h.w. temperature: All sensors with sensing element LG-Ni 1000, for example: Strap-on sensor QAD22 Immersion sensor QAE212 and QA21.3 Collector sensor (solar) QA21.2 Room temperature: Room unit QAW50 and QAW70 Room sensor QAA10 Outdoor temperature: Outside sensor QAC22 (LG-Ni 1000 sensing element) Outside sensor QAC32 (NC measuring element) ressure: sensor with output signal DC 0 10 V: ressure sensor QBE2002 All electromotoric and electrohydraulic actuators for 3-position control and with an operating voltage AC 24 230 V made by Siemens can be used. lants can be remotely monitored, read and operated via odbus RU. An appropriate master is required as communications partner. he controllers communicate as slaves via odbus RU. he Basic Documentation 2510 includes a table with all odbus data points. echnical design Functioning Controller RVD120 has 3 plant types preprogrammed Controller RVD140 has 8 plant types preprogrammed When commissioning the system, the respective plant type must be selected. he required functions, settings and displays will then be automatically assigned. he parameters not required for the plant in question will not be shown. Optional functions must be configured as such. lant types B9 N1 U2 B1 A6 2510S01 lant type no. 1 RVD120 and RVD140 Heating circuit control without d.h.w. heating RVD140: Refill function optional Y1 B7 B71 1 Building echnologies 09.11.2009 3/14

B9 U2 B9 Y1 B7 N1 N1 B1 B71 1 U2 B1 1 B9 Y1 A6 3 A6 2 B7 B71 2 Y7 N1 U2 B1 A6 B9 Y1 B7 B71 1 Y5 N1 B71 7 H5 U2 B1 A6 Y1 B7 1 B71 Y7 7 7 B6 lant type no. 2 RVD120 and RVD140 Heating circuit control with d.h.w. heating (storage tank). RVD140: Circulating pump, refill function, electric immersion heater and solar d.h.w. heating pump optional lant type no. 3 RVD120 and RVD140 Heating circuit control with d.h.w. heating (storage tank). RVD140: Circulating pump, refill function, electric immersion heater and solar d.h.w. heating optional lant type no. 4 only RVD140 Separate heat exchangers for heating circuit and d.h.w. heating (instantaneous system). Sensor B71: as a d.h.w. sensor, or for DR function Circulating pump, flow switch and refill function optional. Selectable idle heat function. lant type no. 5 only RVD140 Separate heat exchangers for heating circuit and d.h.w. heating, 2-stage d.h.w. control: 1st stage in the primary return, 2nd stage with mixing valve in the secondary flow. Flow switch, refill function and externally controlled circulating pump optional. Selectable idle heat function. Y5 H5 U2 B9 Y5 N1 B1 Y1 B7 B71 1 3 A6 B71 2 7 B6 lant type no. 6 only RVD140 Separate heat exchangers for heating circuit and d.h.w. heating. Instantaneous storage tank connected to separate heat exchanger, d.h.w. charging with charging pump. Sensor B71: as a d.h.w. sensor, or for DR function Circulating pump, refill function, electric immersion heater and solar d.h.w. heating optional. U2 B9 N1 A6 Y1 B7 B71 1 Y5 B1 3 7 B71 2 B6 lant type no. 7 only RVD140 wo heat exchangers connected in series for heating circuit and d.h.w. heating. Instantaneous storage tank connected to the second heat exchanger, with mixing valve control for d.h.w. Sensor B71: as a d.h.w. sensor, or for DR function Refill function, electric immersion heater, solar d.h.w. heating and externally controlled circulating pump optional. 4/14 Building echnologies 09.11.2009

U2 B9 N1 B71 A6 Y1 B7 1 Y5 B1 3 2 7 B6 lant type no. 8 only RVD140 Heating circuit control with d.h.w. heating. Heating circuit with mixing valve control, storage tank with charging pump. Circulating pump, refill function, electric immersion heater and solar d.h.w. heating optional. A6 Room unit / room sensor 1 Heating circuit pump B1 Flow sensor (controlled variable) 3 D.h.w. charging pump D.h.w. sensor / storage tank sensor 1 7 Circulating pump (only with RVD140) 2 Storage tank sensor 2 (only with RVD140) External circulating pump B6 Collector sensor (only with RVD140) N1 Controller B7 rimary return sensor Secondary pressure sensor (only with RVD140) B71 Universal sensor U2 rimary pressure sensor (only with RVD140) B9 Outside sensor Y1 wo-port valve in the primary return H5 Flow switch (only with RVD140) Y5 wo-port valve / mixing valve ultifunctional output K6 or K7 (only with RVD140) Y7 Changeover valve / mixing valve Heating circuit control Operating modes Automatic operation Automatic heating according to the time switch program, automatic ECO function and room unit active Continuous operation Heating with no time switch program, setpoint adjustment with the setting knob rotection Heating off, frost protection ensured Automatic d.h.w. heating anual operation No control, circulating pumps in service Frost protection is ensured in all operating modes. Acquisition of measured values Flow sensor: LG-Ni 1000 Outside sensor: LG-Ni 1000 or NC 575 ressure sensor: DC 0 10 V rimary return sensor: LG-Ni 1000 Room temperature: With S-room unit or S-room sensor If different types of sensors are used, the controller automatically identifies the type of sensor connected. Compensating variables Setpoints With weather-compensated control systems, the composite outside temperature is used as the compensating variable. It is generated from the actual and the attenuated outside temperature (calculated by the controller). Consideration is given to the type of building construction (adjustable for light and heavy buildings). he following setpoints can be adjusted: Nominal room temperature Reduced room temperature Room temperature for frost protection Building echnologies 09.11.2009 5/14

Generation of flow temperature setpoint Weather-compensated control: he flow temperature setpoint is controlled in function of the prevailing outside temperature via the heating curve Weather-compensated control with room temperature influence: he flow temperature setpoint is controlled in function of the prevailing outside temperature and, in addition, in function of the deviation of the actual room temperature from the setpoint Room temperature-compensated control: he setpoint is controlled in function of the deviation of the actual room temperature from the setpoint Control he controlled variable is always the secondary flow temperature. In all types of plant, it is controlled through a two-port valve in the primary return depending on the plant's total demand for heat (space heating plus if present d.h.w. heating). aximum limitation of return temperature he valve in the primary circuit starts traveling towards the closed position when the limit value is exceeded. he characteristic is constant-shifting depending on the outside temperature. Quick setback When changing from the normal temperature to a lower temperature level ( or ), the heating will be shut down. If there is a room sensor present, it will be switched on again when the setpoint of the lower temperature level is reached If there is no room sensor present, quick setback is active during a defined period of time, which depends on the type of building construction and an adjustable gain factor. he function can be deactivated, if required Automatic ECO function With the automatic ECO function, the heating is controlled depending on demand. he heating will be shut down if permitted by the outside temperature. Consideration is given to the actual, the attenuated and the composite outside temperature, as well as to an adjustable heating limit. he ECO function requires the use of an outside sensor. It can be deactivated, if desired. aximum and minimum limitation of flow temperature Both limitations are accomplished via the heating curve. When the limit value is reached, the heating curve assumes a constant value. Any active limitation is shown on the display. Both limitations can be deactivated. DR function he differential between the primary and the secondary return temperature is limited to a maximum value. ime switch programs o provide automatic operation of the heating system, the controller RVD120/140 features a weekly program with 3 heating periods that can be adjusted on a daily basis. Another weekly program is available for the release of d.h.w. charging. ump kick he pump kick is adjustable for the heating circuit pump, the d.h.w. charging pump, the collector pump and the circulating pump. he pump kick is made once per week and lasts 30 seconds. he function can be deactivated, if required. 6/14 Building echnologies 09.11.2009

Heating curve 2510D01 s A V Slope Composite outside temperature Flow temperature Relay and sensor tests o facilitate commissioning and fault tracing, both relay and sensor tests can be made: Relay test: each of the relays can be manually energized Sensor test: all sensor values can be interrogated ulse lock with actuators he total duration of the closing pulses delivered to an actuator is limited to five times the actuator's running time, in order to extend the life of the relay contacts. Raising the reduced room temperature he setpoint of the reduced room temperature can be raised as the outside temperature falls. he increase (effect) is adjustable. his function can be deactivated, if required. Frost protection for the building Frost protection for the building ensures an adjustable minimum room temperature. his function cannot be deactivated. Frost protection for the plant Frost protection for the plant protects the heating plant against freeze-ups through activation of the heating circuit pump. his function can be provided with or without an outside sensor: With outside sensor: Outside temperature 1.5 C: the heating circuit pump runs for 10 minutes at 6-hour intervals Outside temperature 5 C: the heating circuit pump runs continuously Without outside sensor: Flow temperature 10 C: the heating circuit pump runs for 10 minutes at 6-hour intervals Flow temperature 5 C: the heating circuit pump runs continuously his function can be deactivated, if required. Refill function he controller RVD140 supports the refill function to maintain the secondary side plant pressure. If it drops below a minimum value, water from the primary side or from a separate tank is refilled in the secondary plant circuit to increase the pressure. Building echnologies 09.11.2009 7/14

D.h.w. heating In addition to heating circuit control, the RVD120/140 provide control of d.h.w. heating in the following types of plant and d.h.w. systems: lant type no. RVD120 RVD140 D.h.w. system 1 2 Storage tank connected to common heat exchanger 3 Storage tank connected to common heat exchanger 4 Instantaneous system connected to a parallel heat exchanger 5 Instantaneous system connected to a parallel heat exchanger 6 Instantaneous storage tank connected to a parallel heat exchanger 7 Instantaneous storage tank connected to common heat exchanger 8 Storage tank connected to common heat exchanger Acquisition of measured values D.h.w. functions with all types of plant lant type-specific d.h.w. functions he acquisition of the d.h.w. temperature is provided with sensors LG-Ni 1000 connected to terminals, 2 and B71. Settings: Normal setpoint and reduced setpoint, maximum setpoint, setpoint boost and switching differential Frost protection for d.h.w.: a minimum temperature of 5 C is always maintained D.h.w. OFF: d.h.w. heating can be manually switched off aximum limitation of the primary return temperature: adjustable is a limit value independent of heating circuit control Release: With plant types no. 2 8, release of d.h.w. heating can be selected: According to own d.h.w. time switch program During the controller's heating periods, with or without forward shift of the first daily release Always (24 hours per day) riority: the behavior of the heating circuit during d.h.w. charging can be selected: Absolute: heating circuit pump deactivated (plant type no. 8: mixing valve fully closed, heating circuit pump remains activated) Shifting: heating circuit pump remains activated as long as there is sufficient heating energy available (plant type no. 8: mixing valve throttled). he d.h.w. setpoint or maximum setpoint is maintained arallel: no priority; heating circuit remains ON. he d.h.w. setpoint or maximum setpoint is maintained Idle heat function: in instantaneous systems, the heat exchanger s primary side is periodically heated up Flow switch: to improve the heat exchanger s control performance, with adjustable load limit, adapts to the seasons, tamperproof (prevents the control system from responding too frequently). Forced charging: d.h.w. charging takes place every day on the first release (or ad midnight with the 24-hour program). It also takes place if the actual value lies within the switching differential anual charging: Independent of the time switch program and temperature conditions During protection mode D.h.w. heating with electric immersion heater or solar collector: In plant types with d.h.w. storage tank, one of the two multifunctional relays of the RVD140 can be parameterized for d.h.w. heating using an immersion heater or a solar collector 8/14 Building echnologies 09.11.2009

Extra functions Remote operation via room units arameter reset anual operation Room unit QAW50: changeover of operating mode, room temperature setpoint adjustments and room temperature readjustments Room unit QAW70: overriding the setpoints and the heating program, entry of holiday periods All settings made can be reset to the factory settings. In manual operation, the heating can be controlled manually. In that case, d.h.w. heating will be shut down and the relays switched as follows: Actuator of primary return valve: no power supply, but can be manually controlled from the controller Other actuators: fully closed, no power supply Heating circuit pump: activated D.h.w. charging pump, collector pump and circulating pump: activated Electric immersion heater: released echanical design Controller he RVD120/140 is comprised of controller insert and base. he controller insert accommodates the electronics, the power section, the output relays and on the front of the unit the LCD featuring background lighting and all operating elements. wo screws are used to secure the controller insert to the base, which carries the connection terminals. he RVD120 contains four relays, the RVD140 nine. he controller can be mounted in three different ways: Wall mounting (on a wall, in a control panel, etc.) op hat rail mounting Flush panel mounting (compact station, control panel front, etc.) Display and operating elements 1 2 1 2 5 6 7 8 1 6 7 C 3 7 5 6 3 rog 20 16 24 rog 20 16 24 4 12 7 12 Front view of RVD140 1 Operating mode buttons 2 Display (LCD) 3 Buttons for selecting operating lines 4 Button for manual operation ON / OFF 5 Button for d.h.w. heating ON / OFF 6 Buttons for making readjustments of values 7 Setting knob for nominal room temperature setpoint Front view of RVD120 Operation Analog operating elements Buttons for selecting the required operating mode and for d.h.w. ON / OFF Setting knob for the room temperature setpoint in continuous operation Button for manual operation he entry or readjustment of all the other setting parameters, activation of optional functions, and reading of actual values and statuses is made using the operating line principle. An operating line with an associated number is assigned to each parameter, each actual value and each function that can be selected. One pair of buttons is used to select an operating line and one pair to readjust the display. hese buttons are located behind a hinged cover. he operating instructions are inserted at the rear of the cover. Building echnologies 09.11.2009 9/14

Notes Engineering he wires of the measuring circuits carry extra low voltage he wires to the actuator and the pumps carry AC 24 230 V he local regulations for electrical installations must be complied with Sensor cables may not be run parallel to mains carrying cables for loads such as actuators and pumps (safety class II to EN 60730) In control systems using a room sensor, the reference room may not be equipped with thermostatic radiator valves. anual valves must be locked in their fully open position Local regulations as well as requirements of the district heat supplier when using the refill function must be complied with ounting Suitable mounting locations are compact stations, control panels, control desks or the heating room. Not permitted are wet or damp locations ounting methods: wall, top hat rail or panel cutout Cable tension relief must be ensured Cable glands made of plastic must be used All terminals for extra low voltage (sensors and room unit bus) are located in the upper section of the terminal compartment, those for mains voltage (actuators and pumps) in the lower section Commissioning he plant type must be selected he settings of the district heating parameters can be locked he controller is supplied complete with mounting and commissioning instructions Disposal In terms of disposal, the RVD120/140 are classified as electronic scrap conforming to the European Directive 2002/96/EC (WEEE) and must not be disposed of as domestic waste. he relevant national legal requirements must be complied with and the units must be disposed of through the relevant channels. Local and currently valid legislation must be observed. Warranty When using the RVD120/140 together with third-party devices not specifically mentioned, correct functioning must be ensured by the user. In that case, Siemens will assume no responsibility for service and warranty. 10/14 Building echnologies 09.11.2009

echnical data ower supply Operating voltage AC 230 V (+10 / 15 %) Rated voltage AC 230 V Frequency 50 Hz ower consumption (no external load) RVD120: max. 5.5 VA RVD140: max. 6.5 VA Supply line fusing 10 A Inputs Sensor inputs (B ) Sensing elements refer to sections Acquisition of measured values Digital input (H5) Voltage with contact open DC 12 V Current with contact closed DC 3 ma Contact resistance R 80 Ω Analog inputs (U ) Operating range DC 0 10 V Input resistance R >100 kω Relay outputs Rated switching voltage AC 24 230 V Rated current Y1, Y2, Q1, K6, K7 AC 0.02 1(1) A Rated current Y5, Y6, Q3/Y7, Q7/Y8 AC 0.02 2(2) A Switch-on current max. 10 A max. 1 s ax. rating as mixing valve relay 15 VA Interfaces odbus RU Basic system RS485 (EIA-485). For details, refer to the modbus specification Connection 2-wire, twisted pairs, shielded Bus terminator (not included in delivery) terminating resistor 150 Ω (0.5 W) for the first and last device on the bus S Connection (room unit or room sensor) 2-wire, interchangeable ermissible cable lengths For all sensors Copper cable, 0.6 mm dia. Copper cable, 1.0 mm 2 Copper cable, 1.5 mm 2 For the room units (S) Copper cable, 0.25 mm 2 Copper cable, from 0.5 mm 2 For the data bus (odbus) Copper cable, from 0.25 mm 2 20 m 80 m 120 m 25 m 50 m 1000 m Connection terminals Screw terminals for wire section up to 2.5 mm 2 Backup Backup of controller clock 12 h Standards conformity to EC directive Immunity and emissions 2004/108/EC EN 60730-1 (for use in industrial and domestic environments) Building echnologies 09.11.2009 11/14

Low voltage directive 2006/95/EC Safety EN 60730-1 / EN 60730-2-9 C-ick conformity to AS/NZS 61000-6-3 Classifications to Software class A EN 60730 ode of operation type 1B (automatic controls) Safety data Safety class II to EN 60730 (when correctly installed) Degree of protection I 40 to EN 60529 (when correctly installed) Degree of contamination 2 to EN 60730 Environmental compatibility he environmental product declaration contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) 2002/95/EC (RoHS) Dimensions refer to Dimensions Weight Unit (net) RVD120: 0.74 kg RVD140: 0.84 kg Colors Controller insert light grey RAL 7035 erminal base pigeon blue RAL 5014 Environmental conditions Operation EN 60721-3-3 ransport EN 60721-3-2 Storage EN 60721-3-1 Climatic conditions class 3K5 class 2K3 class 1K3 emperature 0 +50 C 25 +70 C 20 +65 C Humidity <95 % r.f. (non-condensing) <95 % r.f. <95 % r.f. (non-condensing) echanical conditions class 32 class 22 class 12 Use above sea level max. 3000 m above sea level 12/14 Building echnologies 09.11.2009

Connection diagrams Low voltage side RVD120 L odbus RU RS485 (EIA-485) * AC 230 V A+ B- N RVD140 L odbus RU RS485 (EIA-485) A6 B9 B1 B71 B6 2 H5 * AC 230 V N A+ B- B6 2 U2 * erminating resistor 150 Ω (0.5 W) for the first and last device on the bus. See odbus specification for details H5 N2 ains voltage side RVD120 (lant types no. 1, 2, 3) 1 actuator and 2 pumps or 1 actuator, 1 pump and 1 changeover valve Q3/Y7 N1 1 3 Y7 RVD140 (lant type no. 5) 3 actuators and 1 pump Q3/Y7 Q7/Y8 Y1 Y5 1 RVD140 (lant types no. 1, 2, 3, 4, 6, 7, 8) 2 actuators and 3 pumps or 2 actuators, 2 pumps and 1 changeover valve Q3/Y7 Q7/Y8 Y1 Y5 1 3 Y7 7 A6 Room unit / sensor 1 Heating circuit pump B1 Flow sensor 3 D.h.w. charging pump D.h.w. sensor / storage tank sensor 1 7 Circulating pump 2 Storage tank sensor 2 odbus RU Data bus B6 Collector sensor N1 Controller RVD120 B7 rimary return sensor N2 Controller RVD140 B71 Universal sensor Secondary pressure sensor B9 Outside sensor U2 rimary pressure sensor H5 Flow switch Y1 Actuator of two-port valve in the K6 and K7 ultifunctional outputs for refill primary return function / electric immersion heater / Y5 Actuator of two-port valve / mixing valve collector pump Y7 Actuator of changeover valve / mixing valve Building echnologies 09.11.2009 13/14

Dimensions max. 3 +1 max. 8 max. 5 +0.8 IEC 61554-144 96 Dimensions in mm 14/14 2009 Siemens Switzerland Ltd Subject to alteration Building echnologies 09.11.2009