General-purpose Relays

Similar documents
General-purpose Relays

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Model Number Structure

Model Number Structure

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

SPST-NO SPDT DPST-NO DPDT

CQM1-SF200/CS1W-SF200

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

SPST-NO SPDT DPST-NO DPDT

General-purpose Relay

Surface Mounting Relay

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

48 SERIES Relay interface modules 10 A

Type Terminal Coil Contact form Model

Solid-State Timer H3G

RY2 miniature industrial relays

Surface Mounting Relay

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

AZ420 MINIATURE GENERAL PURPOSE RELAY

60 Series - General purpose relays 6-10 A. Features

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Standard with LED indicator

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

How To Read A Pipe From A Sensor

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Model Number Legend. Application Examples. Surface Mounting Relay

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

49 Series - Relay interface modules A. Features

38 Series - Relay interface modules A

38 Series - Relay interface modules A

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

2 POLES - 5A LOW PROFILE TYPE

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Solid State Relays for Heaters

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

SKR - industry relay

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

40 Series - Miniature PCB/Plug-in relays A. Features

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

Smile 11 AS-i Emergency stop with safe AS-i input node

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Tina 2A/B Adaptor unit

NX safety stand-alone

Original instructions Tina 3A/Aps Adaptor unit

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Safety Manual BT50(T) Safety relay / Expansion relay

Multifunction Digital Timer

RM4TG20 three-phase network control relay RM4-T - range V

1a/1c 5A/10A small power relays

1 POLE - 5A SLIM POWER RELAY

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

1 POLE - 8A Medium Load Control

FP2 Relay. The Best Relaytion

Solid State Relays with Built-in Current Transformer

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Pluggable interface relays CR-P Pcb relays

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Thermal-Magnetic Circuit Breaker M1-..

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Liquid Leakage Sensor Amplifier

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Phase-sequence Phase-loss Relay

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

Aluminum Electrolytic Capacitors Power Economic Printed Wiring

Cross-beam scanning system to detect slim objects. 100 mm in

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Proximity Sensor with All-stainless Housing

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

User s Manual Before using the inverter, you need to read and save the safety instructions.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

3 Port Solenoid Valve

Goodsky Technical Data. Contact Details

WE70. FA Wireless LAN Unit. Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE a/b/g

Elesta Elektrotechnik AG industry relays and accessories

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Transcription:

General-purpose Relays MK-S New Model General-purpose Relays Featuring Mechanical Indicator and Lockable Test Button Built-in operation indicator (mechanical and LED), and new models with lockable test button. Nameplate provided on models with lockable test button. RoHS Compliant. UL approval for most models. (UL approval pending for models with built-in LED indicators.) Features Two-way Action Test Button Relay in Normal Operation For Momentary Operation For Lock Operation Yellow button Pull down the test button to the first position, then press the yellow button with an insulated tool to operate the contact. Pull down the test button to the second position. (The contact is now in the locked position.) Model Number Structure Model Number Legend MKS@@@@@-@-@ 1 1. Contact Form : DPDT : PDT. Terminals P: Plug-in. Mechanical Indicator/Test Button Blank: Mechanical indicator I: Mechanical indicator and lockable test button. LED Indicator Blank: Standard N: LED indicator. Coil Polarity Blank: Standard 1: Reverse polarity (DC coil only). Surge Absorption Blank: Standard D: Surge absorber diode (DC coil only) V: Surge absorber varistor (AC coil only). Internal Connections Blank: Standard or : Non-standard connections (Refer to Terminal Arrangement/Internal Connection.). Rated Voltage (Refer to Coil Ratings.) General-purpose Relays MK-S New Model 1

Ordering Information List of Models Type Standard Models LED Indicator (See note.) Diode (See note.) LED Indicator and Diode Varistor LED Indicator and Varistor Terminals Contact form Internal connections (See note.) List of Models (Order Separately) With mechanical indicator With mechanical indicator and lockable test button Coil ratings Plug-in DPDT Standard MKSP MKSPI AC/DC Non-standard MKSP- MKSPI- PDT Standard MKSP MKSPI Non-Standard MKSP- MKSPI- MKSP- MKSPI- DPDT Standard MKSPN(1) MKSPIN(1) AC/DC Non-standard MKSPN(1)- MKSPIN(1)- PDT Standard MKSPN(1) MKSPIN(1) Non-Standard MKSPN(1)- MKSPIN(1)- MKSPN(1)- MKSPIN(1)- DPDT Standard MKSP(1)-D MKSPI(1)-D DC Non-standard MKSP(1)-D- MKSPI(1)-D- PDT Standard MKSP(1)-D MKSPI(1)-D Non-Standard MKSP(1)-D- MKSPI(1)-D- MKSP(1)-D- MKSPI(1)-D- DPDT Standard MKSPN-D MKSPIN-D DC Non-standard MKSPN-D- MKSPIN-D- PDT Standard MKSPN-D MKSPIN-D Non-Standard MKSPN-D- MKSPIN-D- MKSPN-D- MKSPIN-D- DPDT Standard MKSP-V MKSPI-V AC Non-standard MKSP-V- MKSPI-V- PDT Standard MKSP-V MKSPI-V Non-Standard MKSP-V- MKSPI-V- MKSP-V- MKSPI-V- DPDT Standard MKSPN-V MKSPIN-V AC Non-standard MKSPN-V- MKSPIN-V- PDT Standard MKSPN-V MKSPIN-V Non-Standard MKSPN-V- MKSPIN-V- MKSPN-V- MKSPIN-V- Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKSP VDC Rated voltage. The DC coil comes in two types: standard coil polarity and reverse coil polarity. Refer to Terminal Arrangement and Internal Connections. Example: MKSPIN1- VDC Reverse coil polarity. Refer to Terminal Arrangement and Internal Connections for non-standard internal connections. Item Type Model Track-mounted Socket -pin PF0A-E 11-pin PF11A-E -pin PF0A-D 11-pin PF11A-D Hold-down Clip (For PF0A-E and PF11A-E) PFC-A1 General-purpose Relays MK-S New Model

Specifications Ratings Coil Ratings Rated voltage Rated current Coil resistance Must operate Must release 0 Hz 0 Hz voltage voltage AC V ma ma.1 Ω 0% max. of rated 0% min. of rated 1 V 1 ma 1 ma 1. Ω voltage voltage at 0 Hz V 110 ma. ma. Ω % min. of rated voltage at 0 Hz 100 V. ma.1 ma 0 Ω 110 V. ma 1.0 ma Ω 00 V 1. ma 11. ma,10 Ω 0 V 1.1 ma 10. ma,0 Ω 0 V 10.0 ma 11. ma,0 Ω 0 V 11.0 ma. ma,0 Ω DC V ma. Ω 1% min. of rated 1 V 11 ma 10 Ω voltage V. ma 0 Ω V.1 ma 1,10 Ω 100 V 1. ma,0 Ω 110 V 1. ma,0 Ω Note: 1. The rated current and coil resistance are measured at a coil temperature of C with tolerances of +1%/ 0% for AC rated current and ±1% for DC coil resistance.. Performance characteristic data are measured at a coil temperature of C.. The maximum voltage is one that is applicable instantaneously to the Relay coil at C and not continuously.. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. ma to the rated current. Contact Ratings Max. voltage 110% of rated voltage Power consumption Approx.. VA at 0 Hz Approx.. VA at 0 Hz Approx. 1. W Load Resistive load (cosφ = 1) Contact mechanism Single Contact material AgSnIn Rated load NO 10 A, 0 VAC 10A, 0 VDC NC A, 0 VAC A, 0 VDC Rated carry current 10 A Max. switching voltage 0 VAC, 0 VDC Max. switching current 10 A Max. switching power NO,00 VA/00 W NC 1,0 VA/10 W Inductive load (cosφ = 0.) A, 0 VAC General-purpose Relays MK-S New Model

Characteristics Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric strength Insulation method Impulse withstand voltage Note: 1. The values given above are initial values.. P level: λ0 = 0.1 10 - /operation. Ambient temperature of models with LED indicator is to 0 C. Approved Standards UL0 (File No. E11) CSA Standard: CSA Certification by : CSA C. No. 1 Note: Applications have been submitted for UL and CSA certification for models with built-in LED indicators. Engineering Data Reference Data 100 mω max. AC: 0 ms max. DC: 0 ms max. 0 ms max.(0 ms max. for built-in Diode Relays) Mechanical: 1,000 operations/h Electrical: 1,00 operations/h (under rated load) 100 MΩ min. (at 00 VDC),00 VAC 0/0 Hz for 1 min between coil and contacts 1,000 VAC 0/0 Hz for 1 min between contacts of same polarity and terminals of the same polarity,00 VAC 0/0 Hz for 1 min between current-carrying parts, non-current-carrying parts, and opposite polarity Basic insulation. kv between coil and contacts (with 1. 0 µs impulse wave).0 kv between contacts of different polarity (with 1. 0 µs impulse wave) Pollution degree Rated insulation voltage 0 V Vibration resistance Destruction: 10 to to 10 Hz, 0.-mm single amplitude (1.-mm double amplitude) Malfunction: 10 to to 10 Hz, 0.-mm single amplitude (1.0-mm double amplitude) Shock resistance Destruction: 1,000 m/s (approx. 100 G) Malfunction: 100 m/s (approx. 10 G) Endurance Mechanical:,000,000 operations min. (at 1,000 operations/h under rated load) Electrical: 100,000 operations h. (at 1,00 operations/h under rated load) Failure rate P level (reference value) 10 ma at 1 VDC Ambient temperature Operating: 0 to 0 C (with no icing or condensation) Ambient humidity Operating: % to % Weight Approx. 0 g Coil ratings Contact ratings Operations to 110 VDC N.O. 10 A, 0 V AC 0/0 Hz (Resistive),000 to 0 VAC contact 10 A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) N.C. A, 0 V AC 0/0 Hz (Resistive),000 contact A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) Maximum Switching Power IEC Standard/TUV Certification: IEC110-1 (Certification No. R010) Coil ratings Contact ratings Operations, 1,,, 100, 110 VDC, 1,, 100, 110, 00, 0, 0 VAC N.O. 10 A, 0 V AC 0/0 Hz (Resistive) 100,000 contact 10 A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) N.C. A, 0 V AC 0/0 Hz (Resistive) 100,000 contact A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) Note: When Relays are mounted on the PF0A-E or PF11A-E, the maximum carrying current is A. Rated Carry Current vs. Ambient Rated Temperature Switching current (A) 100 0 0 DC resistive load with NO contact AC resistive load with NO contact Rated carry current (A) 10 UL derating curve 10 DC resistive load with NC contact AC resistive load with NC contact AC inductive load (cosφ = 0.) 1 10 0 0 100 00 00 1.000 Switching voltage (V) 0 0 0 0 0 0 0 0 Ambient temperature ( C) Note: The lower limit of the ambient operating temperature for models with built-in operation indicators is C. General-purpose Relays MK-S New Model

Dimensions Note: All units are in millimeters unless otherwise indicated. out Test Button Lockable Test Button. max.. max.. max. 0.. max.. max. 0.. max. Sockets See below for Socket dimensions. Socket Surface-mounting Socket (for track or screw mounting) Finger-protection models --- Maximum carry current 10 A A poles PF0A-E PF0A-D PF0A poles PF11A-E PF11A-E-D PF11A Note: Use the Surface-mounting Sockets (i.e., finger-protection models) with "-E" at the end of the model number. When using the PF0A and PF11A, be sure not to exceed the Socket's maximum carry current of A. Using at a current exceeding A may lead to burning. Round terminals cannot be used for finger-protection models. Use Y-shaped terminals. PF0A-E (Conforming to EN 00) Terminal Arrangement Eight, M. sems PF11A-E (Conforming to EN 00) Eleven, M. sems Terminal Arrangement max.. max.. 1 max.. 1 max. Mounting Holes Two, M or two.-dia. holes. max.. 1 max. Mounting Holes Two, M or two.-dia. holes ±0. ±0. General-purpose Relays MK-S New Model

PF0A-D PF11A-D. Terminal Arrangement 1 1. Terminal Arrangement 1 1 Eight, M screws A 1 1 11 A1 Eight, M screws 10 A 11 1 A1 1 Mounting Holes Two, M or two.-dia. hole Mounting Holes Two, M or two.-dia. hole 0 0 Hold-down Clips PFC-A1 ( pieces per set). 0.. Mounting Tracks PFP-100N, PFP-0N (Conforming to EN 00) PFP-100N (Conforming to EN 00)..±0.1 ±0. ±0.1. ±0. 1. 1 * 10 10 1000 (00)* 1 1 1 10 10 1000± 1 1. * This dimension applies to the PFP-0N Mounting Track. * A total of twelve. elliptic holes is provided with six holes cut from each track end at a pitch of 10 mm. Mounting Height with Sockets Surface-mounting Sockets. (See note.) Two poles.. (See note.) Three poles. PF0A(-E) PF11A(-E) Note: PF0A(-E) and PF11A(-E) allow either track or screw mounting. General-purpose Relays MK-S New Model

Terminal Arrangement/Internal Connection (Bottom View) Standard Models (AC/DC Coil) MKSP(I) MKSP(I)- MKSP(I) MKSP(I)- MKSP(I)- 1 1 LED Indicator (AC Coil) MKSP(I)N MKSP(I)N- MKSP(I)N MKSP(I)N- MKSP(I)N- 1 1 Diode (DC Coil: Standard Polarity) MKSP(I)N MKSP(I)N- MKSP(I)N MKSP(I)N- MKSP(I)N- 1 1 LED Indicator and DIode (DC Coil: Reverse Polarity) MKSP(I)N1 MKSP(I)N1- MKSP(I)N1 MKSP(I)N1- MKSP(I)N1-1 1 Standard Models (DC Coil: Standard Polarity) MKSP(I)-D MKSP(I)-D- MKSP(I)-D MKSP(I)-D- MKSP(I)-D- 1 1 Diode (DC Coil: Reverse Polarity) MKSP(I)1-D MKSP(I)1-D- MKSP(I)1-D MKSP(I)1-D- MKSP(I)1-D- 1 1 LED indicator (DC Coil) MKSP(I)N-D MKSP(I)N-D- MKSP(I)N-D MKSP(I)N-D- MKSP(I)N-D- 1 1 General-purpose Relays MK-S New Model

Varistor (AC Coil) MKSP(I)-V MKSP(I)-V- MKSP(I)-V MKSP(I)-V- MKSP(I)-V- 1 1 LED indicator and Varistor (AC Coil) MKSP(I)N-V MKSP(I)N-V- MKSP(I)N-V MKSP(I)N-V- MKSP(I)N-V- 1 1 Safety Precautions Safety Precautions for Correct Use Installation Mount the MK-S with the marking at the bottom. Handling Check the coil polarity of models with built-in diodes and wire them correctly (DC operation coil). Test Button Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. Check that the test button is released before turning ON relay circuits. If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. Use an insulated tool when you operate the test button. test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled. General-purpose Relays MK-S New Model

General-purpose Relays MK-S New Model

10 General-purpose Relays MK-S New Model

General-purpose Relays MK-S New Model 11

Warranty and Application Considerations Read and Understand this Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.0. To convert grams into ounces, multiply by 0.0. Cat. No. J1-E1-01 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Control Devices Division H.Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 00-0 Japan Tel: (1)--10/Fax: (1)--1 Printed in Japan????-?M (????) (?)